DC/DC Converters TES 2M Series, 2 Watt CB Features Supplementary and reinforced insulation I/O isolation 4000 VACrms rated for Scheme IEC 60950-1 IEC 60601-1 UL 60950-1 ES 60601-1 300 Vrms working voltage Unregulated device 2 x MOOP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Industrial safety to UL/IEC/EN 60950-1 Ultracompact SMD-package Operating temp. range -25C to +80C Qualified for leadfree reflow solder process Available in tape & reel package 3-year product warranty The TES 2M series is range of compact 2W DC/DC-converters providing a high I/O-isolation voltage of 4000 VAC. With a reinforced I/O-isolation system this product is an economical solution for many applications in instrumentation, industrial controls, medical equipment and everywhere where supplementary- or reinforced insulation is required. These converters are qualified for high solder temperature profiles in leadfree solder processes. For automated SMD production lines the devices can be supplied in tape & reel package. Full SMD-design with exclusive use of ceramic capacitors ensure a very high reliability and a long product lifetime. Models Ordercode Input voltage range Output voltage Output current max. Efficiency typ. TES 2-0511M 5 VDC 400 mA 66 % TES 2-0512M 12 VDC 165 mA 66 % TES 2-0513M 5.0 VDC 10% (nominal 05 VDC) 15 VDC 133 mA 66 % 12 VDC 83 mA 72 % TES 2-0523M 15 VDC 66 mA 73 % TES 2-1211M 5 VDC 400 mA 66 % 12 VDC 165 mA 66 % 15 VDC 133 mA 66 % TES 2-0522M TES 2-1212M TES 2-1213M TES 2-1222M 12.0 VDC 10% (nominal 12 VDC) 12 VDC 83 mA 74 % TES 2-1223M 15 VDC 66 mA 75 % TES 2-2411M 5 VDC 400 mA 66 % 12 VDC 165 mA 66 % 15 VDC 133 mA 66 % 12 VDC 83 mA 74 % 15 VDC 66 mA 75 % TES 2-2412M TES 2-2413M TES 2-2422M TES 2-2423M www.tracopower.com 24 VDC 10% (nominal 24 VDC) Page 1 of 3 DC/DC Converters TES 2M Series 2 Watt Input Specifications Input current no load 5 Vin models: 60 mA typ. 12 Vin models: 30 mA typ. 24 Vin models: 15 mA typ. Reverse voltage protection 0.3 A max. Recommended input fuse (slow blow) 5 Vin models: 1.0 A 12 Vin models: 0.5 A 24 Vin models: 0.2 A Surge voltage (1 sec. max.) 5 Vin models: 9 V max. 12 Vin models: 18 V max. 24 Vin models: 30 V max. Input filter internal capacitors Output Specifications Voltage set accuracy 4 % Voltage balance (dual output models) 1 % max. Regulation - Input variation 1.2 % / 1 % change of Vin - Load variation 20 - 100 % 10 % max. 12 % max. for 5 Vout models. Ripple and noise (0-20 MHz Bandwidth) 150 mVp-p max. Temperature coefficient 0.02 %/K Short circuit protection 0.5 sec. max. (automatic recovery) Minimum load 2 % of rated max current. Capacitive load single output models: 330 F max. dual output models: 100 F max. (each output) General Specifications Temperature ranges - Operating -25C to +80C - Storage -55C to +125C - Case temperature +90C max. Derating 2.5 %/K above 60C Humidity (non condensing) 95 % rel. H max. Reliability, calculated MTBF (MIL-HDBK-217F at +25C, ground benign) >2.0 Mio h Isolation voltage (50Hz, 60sec.) - Input/Output 4000 VACrms (reinforced) Isolation test voltage (1 sec.) 6000 Vpk Leakage current (at 240VAC, 60Hz) 2 A max. Isolation capacitance - Input/Output 20 pF max. (at 100KHz, 1V) Isolation resistance - Input/Output >10 Gohm (at 500VDC) Safety approvals - Certification documents IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, ANSI/AAMI ES60601-1 and CAN/CSA-C22.2 No. 60601-1, Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance www.tracopower.com/overview/tes2m Switching frequency 50 - 100 kHz (PFM) Environmental compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS directive 2011/65/EU All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 3 DC/DC Converters TES 2M Series 2 Watt Physical Specifications Casing material plastic Pin material phosphor bronze Weight 3.8 g (0.13oz) Lead-free reflow solder process as per J-STD-020D.01 (to find at: www.jedec.org - free registration required) Moisture sensivity level (MSL) level 2 as per J-STD-033B.01 (to find at: www.jedec.org - free registration required) Supporting Documents: www.tracopower.com/overview/tes2m Outline Dimensions 9.0 (0.35) 0.25 (0.01) 24.0 (0.94) 0 - 4 1.0 (0.04) O1.5 (O 0.06) vent hole with membrane on bottom side 7 8 2.54 (0.10) Pin Single Dual 1 -Vin (GND) -Vin (GND) 7 No con. No con. 8 No con. Common 9 +Vout +Vout 10 -Vout -Vout 16 +Vin +Vin 1.4 (0.055) min. Dimensions in [mm], () = Inch Tolerances 0.25 (0.01) Pin pitch tolerances 0.05 (0.002) 2.8 3.11 (0.12) 15.24 (0.60) (0.11) 13.7 (0.54) 2.8 Solder Pad Dimension (0.11) 15.24 (0.60) 18.1 (0.71) top view 1 3.11 (0.12) Pin-Out 9 13.7 (0.54) 10 9.4 (0.37) 16 0.15 (to allow proper washing process) 10.6 (0.42) 2.54 (0.10) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. October 23, 2018 Page 3 of 3