VREF Reference Voltage
∆VOUT Line Regulation 1
∆IOUT
∆VOUT Load Regulation 1
∆IOUT
Thermal Regulation
Ripple Rejection
IADJ Adjust Pin Current
∆IADJ Adjust Pin Current
Change
IMIN Minimum Load
Current
ICL Current Limit
∆VOUT Temperature
∆TEMP Stability
∆VOUT Long Term Stability
∆TIME
enRMS Output Noise
(% of VOUT)
RθJC Thermal Resistance
Junction to Case
IOUT = 10mA
IOUT = 10mA to 3A
VIN – VOUT = 3V to 35V
P≤30W TJ= –55 to +150°C
VIN – VOUT = 3V to 35V
TJ= –55 to +150°C
IOUT = 10mA to 3A VOUT ≤5V
TJ= –55 to +150°C
IOUT = 10mA to 3A VOUT ≥5V
TJ= –55 to +150°C
tp= 20ms TA= 25°C
CADJ = 0
VOUT = 10V CADJ = 10µF
f = 120Hz TJ= –55 to +150°C
TJ= –55 to +150°C
IOUT = 10mA to 3A
VIN – VOUT = 3V to 35V
TJ= –55 to +150°C
VIN – VOUT = 35V
TJ= –55 to +150°C
VIN – VOUT ≤10V
TJ= –55 to +150°C
VIN – VOUT = 30V
TJ= –55 to +150°C
TA= 125°C t = 1000 Hrs
f = 10 Hz to 10 kHz
TA= 25°C
K Package (TO–3)
G Package (TO–257)
1.238 1.25 1.262
1.225 1.250 1.270
0.005 0.010
0.020 0.050
515
15 50
0.1 0.3
0.3 1
0.002 0.010
65
66 86
50 100
0.2 5
3.5 5
3 4.5
0.3 1
12
0.3 1
0.001
1.5
34
1.200 1.250 1.300
0.005 0.010
0.020 0.050
515
20 50
0.1 0.3
0.3 1
0.002 0.010
65
66 86
50 100
0.2 5
3.5 5
3 4.5
0.3 1
1
0.3 1
0.001
1.5
34
V
V
% / V
mV
%
%/W
dB
dB
µA
µA
mA
A
A
%
%
%
°C/W
IP150A SERIES
IP150ASERIES
IP350A SERIES
IP350ASERIES
LM150 SERIES
Document Number 6235
Issue 1
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package
for the TO–3 package and on the back of the heat tab for the TO–247AD, TO–220 and TO–257 packages.
2) Test Conditions unless othewise stated: VIN – VOUT = 5V , TJ= 25°C , IOUT = 1.5A.
Although power dissipation is internally limited, these specifications apply for dissipations of 30W for the TO–3, TO–247AD and
TO–257 packages, and 25W for the TO–220 package; IMAX = 3A.
LM150
IP150A IP150
Parameter Test Conditions Min. Typ. Max. Min. Typ. Max. Units
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.