PHOENIX CONTACT Deutschland GmbH Page 1 / 5
http://www.phoenixcontact.de Feb 4, 2011
Extract from the online
catalog
FL IF 2FX SC-D
Order No.: 2832425
The illustration shows a version with front connection
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832425
FO media module for connecting 100Base-FX multimode glass fibers
(1300 nm), connection direction downwards
Commercial data
GTIN (EAN)
4 017918 929138
sales group K000
Pack 1 pcs.
Customs tariff 85176200
Catalog page information Page 189 (AX-2009)
Product notes
WEEE/RoHS-compliant since:
05/21/2008
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Interfaces
Interface Ethernet: 100Base-FX in acc. with IEEE 802.3
No. of ports 2
Type of connection SC connector
Transmission speed 100 MBit/s (connection direction downwards)
FL IF 2FX SC-D Order No.: 2832425
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832425
PHOENIX CONTACT Deutschland GmbH Page 2 / 5
http://www.phoenixcontact.de Feb 4, 2011
Transmission length 10000 m (maximum (depends on the fiber used))
Interface Ethernet: 100Base-FX in acc. with IEEE 802.3
No. of ports 2
Type of connection SC connector
Transmission speed 100 MBit/s
Transmission length 2800 m (glass fiber with F-G 50/125 1.6 dB/km F800)
6400 m (glass fiber with F-G 50/125 0.7 dB/km F1200)
3000 m (glass fiber with F-G 62.5/125 2.6 dB/km F600)
2800 m (glass fiber with F-G 50/125 1.6 dB/km F800)
Function
Basic functions Media module for modular managed switch
Supply voltage
Supply voltage (via head station)
Typical current consumption 200 mA
General data
Weight 80 g
Width 31 mm
Height 75.7 mm
Depth 72.5 mm
Degree of protection IP20
Ambient temperature (operation) 0 °C ... 55 °C (no condensation)
Ambient temperature (storage/transport) -20 °C ... 70 °C
Permissible humidity (operation) 10 % ... 95 % (no condensation)
Permissible humidity (storage/transport) 10 % ... 95 % (no condensation)
Housing material PA
Noise emission EN 61000-6-3/-4
Noise immunity EN 61000-6-2:2005
Mechanical tests
Type of test Shock test in acc. with IEC 60068-2-27
Test result Operation: 25 g, 11 ms duration, semi-sinusoidal shock impulse
Type of test Shock test in acc. with IEC 60068-2-27
Test result Storage/Transport: 50 g, 11 ms duration, semi-sinusoidal shock
impulse
Type of test Vibration resistance in acc. with IEC 60068-2-6
FL IF 2FX SC-D Order No.: 2832425
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832425
PHOENIX CONTACT Deutschland GmbH Page 3 / 5
http://www.phoenixcontact.de Feb 4, 2011
Test result Operation/Storage/Transport: 5 g, 150 Hz, Criterion 3
Inflammability class acc. to UL 94 V0
Conformity with EMC directives
Developed in acc. with standard IEC 61000-6.2
Test standard IEC 61000-4-2 (ESD)
Test result Criterion B
Test standard IEC 61000-4-3 (immunity to radiated interference)
Test result Criterion A
Test standard IEC 61000-4-4 (burst)
Test result Criterion A
Test standard IEC 61000-4-5 (surge)
Test result Criterion A
Test standard IEC 61000-4-6 (immunity to conducted interference)
Test result Criterion A
Test standard IEC 61000-4-8 (immunity to magnetic fields)
Test result Criterion A
Test standard EN 55022 (emitted interference)
Test result Criterion A
Certificates / Approvals
Certification ABS, BV, CUL, DNV, GL, LR, UL
Certification Ex: CUL-EX LIS, UL-EX LIS
FL IF 2FX SC-D Order No.: 2832425
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832425
PHOENIX CONTACT Deutschland GmbH Page 4 / 5
http://www.phoenixcontact.de Feb 4, 2011
Diagrams/Drawings
Dimensioned drawing
The illustration shows a version of the interface module with the
head station FL SWITCH MM HS
FL IF 2FX SC-D Order No.: 2832425
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2832425
PHOENIX CONTACT Deutschland GmbH Page 5 / 5
http://www.phoenixcontact.de Feb 4, 2011
Address
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
© 2011 Phoenix Contact
Technical modifications reserved;