Sunpower (UK) Ltd, Orion House, Calleva Park, Aldermaston, Berkshire, RG7 8SN.
Tel: +44 (0)118 981 1001 Fax: +44 (0)118 981 2002 Email: sales@sunpower-uk.com
Home > Products >Enclosed > 60W Single Output Enclosed DC-DC Converter
SDS-060B Series - 60W Single Output Enclosed DC-DC Converter
24V DC Input
Input under voltage protection
Input polarity reverse protection
Soft start function, low inrush current
Over load, over voltage, short circuit protection
Output voltage ±10% adjustment
No minimum load requirement
100% 50°C burn-in test
Meets UL, cUL, TUV standards
High efficiency, high reliability
Light weight
Features Standards
Specification
Input Range 18VDC ~ 36V DC (Typically 24V)
Input Current <4.6A@18V DC 6.3A/250V
Input Protection Ceramic fuse 6.3A/205V
Over Voltage Protection Unit will shutdown if an over voltage conditions occurs. Auto recovery once fault is removed
Over Load Protection 105% ~ 180% of rated output. Auto recovery
Short Circuit Protection Unit will shutdown if a short circuit conditions occurs. Auto recovery once fault is removed
Input Voltage
Protection <15VDC ~ 17VDC Unit will shutdown
Rise Time <20ms
Cooling Natural cooling
Operation Temperature 0°C to +70°C, derating: 45°C~70°C:2%/°
Storage Temperature -10°C to +75°C
Operation Humidity 20% to 85% RH non condensing
Storage Humidity 10%~95% non condensing
MTBF >340,000 hours
Safety UL60950, CSA C22.2 No 60950, TUV EN 60 950, IEC 60950, EMKO-TSE (74-SEC)207/94
EMI FCC CFR 47 PART 15 Class B, EN 50081-1, CNS 13438 Class B, EN50082-1 (1997)
EMS EN 55024 : EN 6100-4-2,3,4,5,6,8.
Sunpower (UK) Ltd, Orion House, Calleva Park, Aldermaston, Berkshire, RG7 8SN.
Tel: +44 (0)118 981 1001 Fax: +44 (0)118 981 2002 Email: sales@sunpower-uk.com
SDS-060B Series
Items
SDS-060B3.3 3.3V 15A ±3% 50mV 68% 50W 3.8V ~ 4.6V
SDS-060B05 5V 12A ±2% 50mV 74% 60W 5.8V ~ 7.0V
SDS-060B12 12V 5A ±1% 100mV 76% 60W 13.8V ~ 17.5V
SDS-060B15 15V 4A ±1% 120mV 76% 60W 17.3V ~ 21.0V
SDS-060B24 24V 2.5A ±1% 150mV 76% 60W 27.6V ~ 33.6V
SDS-060B48 48V 1.3A ±1% 240mV 76% 60W 55.2V ~ 67.2V
Part No Voltage Max Load Regulation Ripple Noise (MAX) Efficiency (TYP) Max Power Over Voltage Protection