2 3 2 2 3 3 1 1 4 1 SO 4 Anti-Parallel Parallel APT2X100S20J APT2X101S20J 27 2 T- 4 APT2X101S20J APT2X100S20J 200V 120A 200V 120A DUAL DIE ISOTOP(R) PACKAGE HIGH VOLTAGE SCHOTTKY DIODE PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS * Rectifiers in Switchmode Power * * * * * * * * * Ultrafast Recovery Times Soft Recovery Characteristics Popular SOT-227 Package Rugged Avalanche Energy Rated * Low Forward Voltage * High Blocking Voltage * Low Leakage Current Supplies (SMPS) * Free Wheeling Diode in Low Voltage Converters All Ratings: TC = 25C unless otherwise specified. MAXIMUM RATINGS Symbol VR Low Losses Low Noise Switching Cooler Operation Higher Reliability Systems Increased System Power Density Characteristic / Test Conditions APT2X101_100S20J UNIT 200 Volts Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward Current (TC = 105C, Duty Cycle = 0.5) 120 RMS Forward Current (Square wave, 50% duty) 213 IF(RMS) IFSM TJ,TSTG EAVL Amps 1000 Non-Repetitive Forward Surge Current (TJ = 45C, 8.3ms) Operating and StorageTemperature Range Avalanche Energy (2A, 50mH) -55 to 150 C 100 mJ STATIC ELECTRICAL CHARACTERISTICS Forward Voltage TYP MAX IF = 100A .89 .95 IF = 200A 1.06 IF = 100A, TJ = 125C IRM Maximum Reverse Leakage Current CT Junction Capacitance, VR = 200V Volts .76 VR = VR Rated 2 VR = VR Rated, TJ = 125C APT Website - http://www.advancedpower.com UNIT mA 10-2003 VF MIN pF 053-6023 Rev B Symbol 40 466 DYNAMIC CHARACTERISTICS APT2X101_100S20J Characteristic Symbol Test Conditions trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM MIN TYP - 68 ns - 234 nC - 6 - 112 ns - 686 nC - 11 - 96 ns - 1736 nC - 32 Amps MIN TYP IF = 100A, diF/dt = -200A/s VR = 133V, TC = 25C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr Reverse Recovery Charge IRRM IF = 100A, diF/dt = -200A/s VR = 133V, TC = 125C Maximum Reverse Recovery Current trr Reverse Recovery Charge Qrr Reverse Recovery Charge IRRM IF = 100A, diF/dt = -700A/s VR = 133V, TC = 125C Maximum Reverse Recovery Current MAX - - UNIT Amps Amps THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions MAX RJC Junction-to-Case Thermal Resistance .33 RJA Junction-to-Ambient Thermal Resistance 20 C/W WT 1.03 oz 29.2 g Package Weight Torque 10 lb*in 1.1 N*m Maximum Terminal & Mounting Torque APT Reserves the right to change, without notice, the specifications and information contained herein. 0.9 0.30 0.25 0.7 0.20 0.5 Note: 0.15 PDM Z JC, THERMAL IMPEDANCE (C/W) 0.35 0.3 0.10 0.1 0.05 10-5 Duty Factor D = t1/t2 SINGLE PULSE Peak TJ = PDM x ZJC + TC 10-4 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION RC MODEL Junction temp (C) 10-2003 t1 t2 0.05 0 053-6023 Rev B UNIT 0.0150 C/W 0.00280 J/C 0.0318 C/W 0.00132 J/C 0.109 C/W 0.00862 J/C 0.174 C/W 0.210 J/C Power (watts) Case temperature (C) FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL APT2X101_100S20J TYPICAL PERFORMANCE CURVES 120 IF, FORWARD CURRENT (A) 300 240 180 TJ = 25C 120 TJ = 125C 60 0 TJ = 150C trr, REVERSE RECOVERY TIME (ns) 360 80 60 40 20 TJ = 125C VR = 133V 0 0 0.5 1.0 1.5 VF, ANODE-TO-CATHODE VOLTAGE (V) Figure 2. Forward Current vs. Forward Voltage 0 200 400 600 800 -diF /dt, CURRENT RATE OF CHANGE(A/s) Figure 3. Reverse Recovery Time vs. Current Rate of Change 40 2000 130A 1500 100A 1000 50A 500 0 0 200 400 600 800 -diF /dt, CURRENT RATE OF CHANGE (A/s) Figure 4. Reverse Recovery Charge vs. Current Rate of Change IRRM, REVERSE RECOVERY CURRENT (A) TJ = 125C VR = 133V TJ = 125C VR = 133V 35 130A 30 25 20 100A 15 50A 10 5 0 0 200 400 600 800 -diF /dt, CURRENT RATE OF CHANGE (A/s) Figure 5. Reverse Recovery Current vs. Current Rate of Change 250 1.2 Duty cycle = 0.5 TJ = 150C trr 200 IRRM 0.8 Qrr 0.6 IF(AV) (A) Kf, DYNAMIC PARAMETERS (Normalized to 700A/s) Qrr trr 1.0 130A 50A 100 TJ = -55C 2500 Qrr, REVERSE RECOVERY CHARGE (nC) 100A 150 100 0.4 50 0.2 0.0 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) Figure 6. Dynamic Parameters vs. Junction Temperature 0 25 50 75 100 125 150 Case Temperature (C) Figure 7. Maximum Average Forward Current vs. CaseTemperature 9000 7000 6000 5000 10-2003 4000 3000 2000 1000 0 .1 1 10 100 200 VR, REVERSE VOLTAGE (V) Figure 8. Junction Capacitance vs. Reverse Voltage 053-6023 Rev B CJ, JUNCTION CAPACITANCE (pF) 8000 APT2X101_100S20J Vr diF /dt Adjust +18V APT20M20LLL 0V D.U.T. 30H trr/Qrr Waveform PEARSON 2878 CURRENT TRANSFORMER Figure 9. Diode Test Circuit 1 IF - Forward Conduction Current 2 diF /dt - Rate of Diode Current Change Through Zero Crossing. 3 IRRM - Maximum Reverse Recovery Current. 4 trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. 5 1 4 Zero 5 0.25 IRRM 3 2 Qrr - Area Under the Curve Defined by IRRM and trr. Figure 10, Diode Reverse Recovery Waveform and Definitions SOT-227 Package Outline 11.8 (.463) 12.2 (.480) 31.5 (1.240) 31.7 (1.248) 7.8 (.307) 8.2 (.322) 053-6023 Rev B 10-2003 r = 4.0 (.157) (2 places) 8.9 (.350) 9.6 (.378) Hex Nut M4 H100 (4 places) W=4.1 (.161) W=4.3 (.169) H=4.8 (.187) H=4.9 (.193) (4 places) 25.2 (0.992) 0.75 (.030) 12.6 (.496) 25.4 (1.000) 0.85 (.033) 12.8 (.504) 4.0 (.157) 4.2 (.165) (2 places) 3.3 (.129) 3.6 (.143) 14.9 (.587) 15.1 (.594) 30.1 (1.185) 30.3 (1.193) 1.95 (.077) 2.14 (.084) Anti-parallel Parallel APT2X100S20J APT2X101S20J Anode 2 Cathode 1 Cathode 1 Anode 1 Anode 1 Anode 2 38.0 (1.496) 38.2 (1.504) Dimensions in Millimeters and (Inches) Cathode 2 Cathode 2 ISOTOP(R) is a Registered Trademark of SGS Thomson. APT's products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved.