Ti125, Ti110 IndustrialCommercial and the Ti100 General Use Thermal Imagers Technical Data The lightest, most rugged and easiest-to-use professional thermal imagers around. A Fluke thermal imager can save you time and money by finding potential problems before they become costly failures. With the innovative features and functionality in the Fluke Ti125, Ti110 and Ti100 imagers, you can perform infrared inspections faster and more efficiently and thoroughly document problem areas for additional follow-up. Ti100 Ti110 Ti125 Industrial, mechanical, electromechanical and general building maintenance. Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring problems or component failure, etc. Made in the U.S.A. of U.S. and non U.S. parts Key features * Exclusive IR-OptiFlexTM focus system--ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger (Ti110 and Ti125). * Always have references handy--IR-PhotoNotesTM annotation system--Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas (Ti110 and Ti125). * Find problems faster and easier--IR-Fusion(R) with AutoBlendTM mode (Ti125 only)--Accurately identify potential issues by combining digital and IR images with AutoBlend. It blends digital and partially transparent IR images into a single informationfilled image. * Multi-mode video recording--focus-free video in visible light and infrared with full IR-Fusion. (Ti110 and Ti125 only). * Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal). Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125, Ti110 IndustrialCommercial and Ti100 General Use Thermal Imagers. Patented Fluke IR-Fusion(R) Technology Enjoy the industry's only point-and-shoot IR-Fusion camera. Fluke patented technology provides the user with both a digital and an infrared image in one to precisely document problem areas. IR-OptiFlexTM focus system Scan for issues significantly faster than before with Fluke's revolutionary, ultra-rugged focus system. The IR-OptiFlex focus system gives you optimum focus by combining focus-free, ease-of-use with the flexibility of manual focus on the same camera. Detailed specifications Ti125 IR resolution (FPA size) Spectral band Capture or refresh rate NETD (Thermal sensitivity) FOV (Field of view) IFOV (Spatial resolution) Temperature measurement range (not calibrated below -10 C) Temperature measurement accuracy Focus mechanism IR-Fusion(R) technology Color alarms Standard palettes Ultra ContrastTM palettes Hot/cold markers User definable spot markers Centerbox (MIN/AVG/MAX) Level and span control Minimum span in auto mode Minimum span in manual mode Minimum IR focus distance Weight Size LCD display Visible camera Minimum automatic parallax correction IR-PhotoNotesTM annotation system Laser pointer Torch Electronic (cardinal) compass Emissivity correction Transmission correction Background (reflected) compensation Voice annotation (audio) Multi-mode video output Multi-mode video recording (standard avi w/ mpeg encoding) Multi-mode video recording (radiometric .Is3) Memory review Battery (field-replaceable, rechargeable) Battery life External battery charging base Charging power supply Drop test Ingress protection (IP) rating (IEC 60529) Recommended Calibration cycle Multifunction card reader Memory storage Direct download capability Operating temperature range Storage temperature range Operating humidity Vibration and shock Safety standards C Tick EMI, RFI, EMC User manuals Standard warranty period Extended warranty and service plans Ti110 Industrial-Commercial 160 x 120 FPA Uncooled Microbolometer 7.5 m to 14 m (long wave) 9 Hz or 30 Hz versions 0.10 C at 30 C target temp (100 mK) 22.5 H x 31 V 3.39 mRad -20 C to +350 C (-4 F to +662 F) 9 Hz -20 C to +250 C (-4 F to +482 F) 2 C or 2 % (at 25 C nominal, whichever is greater) Focus-free 1.2 m (4 ft) and beyond IR-OptiFlexTM focus system PIP, FULL IR, FULL VISIBLE, AutoBlend PIP, FULL IR, FULL VISIBLE No, full IR only High temperature, low temperature, High temperature -- isotherm Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Blue-Red, Ironbow, Grayscale, Amber, Inverted Amber Amber Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Blue-Red, Grayscale, Ironbow -- Ironbow, Amber, Inverted Amber Yes -- in SmartView(R) only Three on camera and in SmartView(R) Yes -- Manual and auto 5 C 2.5 C 15.25 cm (6 in) 1.2 m (4 ft) 0.726 kg (1.6 lb) 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) 3.5 inch diagonal (portrait format) 2 megapixel industrial-grade N/A ~18-22 inches N/A Yes (3 images) -- Yes Yes -- Yes -- Yes Yes -- Yes Yes (60 seconds) per image -- Streaming USB video output (infrared, -- visible and IR-Fusion modes) Yes (AVI with MPEG encoding, up to 5 minutes) -- Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene -- thumbnail review Two One 4+ hours (each)* Yes Optional (accessory) Yes 2 meter (6.5 feet) IP 54 Two-years Included -- 2 GB SD memory card mini USB download direct to PC -10 C to +50 C (14 F to 122 F) -20 C to +50 C (-4 F to 122 F) Operating and storage 10 % to 95 %, Non-condensing 2G, IEC 68-2-26 and 25G, IEC 68-2-29 CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 IEC/EN 61326-1 EN61326-1; FCC Part 5 Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian Two-years Yes *Assumes 50% brightness of LCD 2 Fluke Corporation Ti100 General use Ti125, Ti110 Industrial/Electrical and Ti100 General Use Thermal Imagers Ordering information FLK-Ti110 30HZ FLK-Ti110 9HZ FLK-Ti125 30HZ FLK-Ti125 9HZ FLK-Ti100 9HZ Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager Industrial-Commercial Thermal Imager General Use Thermal Imager Included with product Thermal imagers are shipped with ac power adapter, lithium ion smart battery (Ti125 includes 2 each--other models 1 each), USB cable, SD memory card, hard carrying case, soft transport bag, adjustable hand strap (left- or right-handed use), printed users manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD--total of 18, SmartView(R) software and warranty registration card. Ti125 model also include a two-bay charging base and a multi-format USB memory card reader. Optional: FLK-TI-VISOR2 FLK-TI-TRIPOD2 BOOK-ITP FLK-TI-SBC3 FLK-TI-SBP3 TI-CAR CHARGER Sun visor Tripod mounting accessory Introduction to Thermography Principles Book External charging base and power supply Extra lithium-ion rechargeable smart battery Thermal imager vehicle charger Fluke. Not just infrared. Infrared you can use.TM Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2011 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 12/2011 4026524B D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. 3 Fluke Corporation Ti125, Ti110 Industrial/Electrical and Ti100 General Use Thermal Imagers Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLK-Ti100 9HZ FLK-Ti110 30HZ FLK-Ti125 30HZ