Characteristics
Note. The data given above are initial values.
* For testing conditions, consult your OMRON sales representative.
Pull-on lock function (D2D-2000 models)
When opening or closing the door, the power ON state of the
Switch can be checked with the door left open when applying
normal (momentar y) operations. By closing the door after
maintenance in spection, the Switch will resume the normal
momentary operation. (This feature is ideal for conducting the
electrical continuity test, inspection, repair, etc. on the Switch
after its assembly.)
Double Spring Mechanism
(D2D-1000/3000 models)
Two return springs are provided for the pin plunger. Thus , if
either of the sp rings is broken, th is f eature will pre v ent the Swi tch
from malfunctioning or short-circuiting.
Direct Contact Opening Mechanism
(D2D-1000 models )
Pushing the plunger will effectively break the circuit on the
NC side even if a contact weld occurs in the Switch.
Direct Contact Opening Mechanism is
not availa ble in NO connection.
Approved Safety Standard
UL (UL1054) /CSA (CSA C22.2 No.55)
VDE (EN61058-1)
Test conditions: 1E4 (10,000 operations) T85 (0°C to 85°C)
Note. The values in parentheses are the motor load ratings .
Mounting Holes (Unit: mm)
Item Model D2D-1000 models D2D-2000 models D2D-3000 models
Permissible operating speed 10 mm to 1 m/s
Permissible
operating
frequency
Mechanical 300 operations/ m in
Electrical 60 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (init i al value) 50 mΩ max.
Dielectric
strength
Between terminals of the same polarity 2,000 VAC 50/60 Hz 1min 1,000 VAC 50/60 Hz 1min 2,000 VAC 50/60 Hz 1min
Between current-carrying metal parts
and ground 2,000 VAC 50/60 Hz 1min 1,500 VAC 50/60 Hz 1min 2,000 VAC 50/60 Hz 1min
Between each terminal and
non-current-carryin g metal parts 2,500 VAC 50/60 Hz 1min 1,500 VAC 50/60 Hz 1min -
Between terminals and actuator 4,000 VAC 50/60 Hz 1min - 4,000 VAC 50/60 Hz 1min
Vibration
resistance Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock
resistance Durability 1,000 m/s2 {approx. 100G} max.
Malfunction 500 m/s2 {approx. 50G} max. 300 m/s2 {approx. 30G} max. 500 m/s2 {approx. 50G} max.
Durability * Mechanical 10,000,000 operations min. (60 operations/min)
Electrical 100,000 operat ions min. (30 operations/min)
Degree of protection IEC IP40
Degree of protection against electric shock Class II
Proof tracking index (PTI) 175
Ambient operating temperature -25 °C to +85 °C (at ambient humidity 60 % max.) (with no icing or condensation)
Ambient operating humidity 85% max. (for +5°C to +35°C)
Weight Approx. 14 g (for D2D-1000)
Example State Contact
NO-NO NC-NC
To turn ON the
power when the
door is closed ON OFF
To turn OFF the
power when the
door is open OFF ON
To turn ON the
power with the
door left open ON OFF