DENSEI-LAMBDA
HWS15/A
SPECIFICATIONS
A224-01-01/A-B
MODEL
ITEMS
1
Nominal Output Voltage
2
Maximum Output Current
A
3
Maximum Output Power
W
4
Efficiency (Typ) (*1)
100VAC
%
200VAC
%
5
Input Voltage Range
(*2)
-
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 370VDC
6
Input Current (100/200VAC)(Typ) (*1)
A
0.4/0.2
7
Inrush Current(Typ)
(*3)
-
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
8
PFHC
-
Built to meet IEC61000-3-2
9
Output Voltage Range
10
Maximum Ripple & Noise
0<Ta<60°C
mV
(*4)
-10<Ta<0°C
mV
11
Maximum Line Regulation
(*5)
mV
12
Maximum Load Regulation
(*6)
mV
13
Temperature Coefficient
-
Less than 0.02% / °C
14
Over Current Protection
(*7)
A
15
Over Voltage Protection
(*8)
16
Hold-up Time (Typ)
(*9)
-
20ms
17
Leakage Current
(*10)
-
Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC
18
Remote Sensing
-
-
19
Parallel Operation
-
-
20
Series Operation
-
Possible
21
Operating Temperature
(*11)
-
-10 ~+60°C (-10 ~+40°C:100%,+50°C:60%,+60°C:20%)
22
Operating Humidity
-
30 ~ 90%RH (No dewdrop)
23
Storage Temperature
-
-30 ~ +85°C
24
Storage Humidity
-
10 ~ 95%RH (No dewdrop)
25
Cooling
-
Convection Cooling
26
Withstand Voltage
-
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
27
Isolation Resistance
-
More than 100M
at 25°C and 70%RH Output - FG : 500VDC
28
Vibration
-
At no operating, 10 ~ 55Hz (Sweep for 1min)
19.6m/s
2
Constant, X,Y,Z 1hour each.
29
Shock (In package)
-
Less than 196.1m/s
2
30
Safety
(*12)
-
Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178
Built to meet UL508, DENAN
31
Line DIP
-
Built to meet SEMI-F47 (200VAC Line only)
32
Conducted Emission
-
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
33
Radiated Emission
-
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
34
Immunity
-
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
35
Weight(Typ.)
-
210g
36
Size (W x H x D)
mm
31.5 x 82 x 80 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
to be described as 100 ~ 240VAC(50/60Hz).
*3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
*4. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz.
For start up at low ambient temperature and low input voltage, output ripple noise might not meet specification.
However, there is no overshoot at start up and output ripple noise specification can be met after one second.
*5. 85 ~ 265VAC , constant load.
*6. No load-Full load, constant input voltage.
*7. Foldback current limit with automatic recovery. Not operate at over load or dead short condition for more than 30seconds.
*8. OVP circuit will shutdown output, manual reset (Re power on).
*9. At 100/200VAC , Ta=25°C, nominal output voltage and maximum output current.
*10.
Measured by the each measuring method of UL,CSA,EN and DENAN(at 60Hz).
*11.
Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A224-01-02/A_).
*12.
As for DENAN, built to meet at 100VAC.
0.68 ~
30.0~34.8
0.34 ~
55.2~64.8
1.36 ~
15.0~17.4
1.05 ~
18.8~21.8
3.15 ~
4.13~4.95
3.15 ~
6.25~7.25
192
38.4~52.8
200
240
192
384
19.2~28.8
200
240
96
96
12.0~18.0
150
180
60
120
180
48
40
4.0~6.0
120
160
20
40
160
20
0.3/0.15
2.97~3.96
120
9.6~14.4
150
15.8
80
HWS15
-24/A
HWS15
-48/A
48
0.33
24
0.65
15.6
80
15
80
15.6
82
HWS15
-15/A
15
1
HWS15
-12/A
12
1.3
5
3
3.3
3
HWS15
-3/A
HWS15
-5/A
10
68
15
77
71
79
81
81
83
80
DENSEI-LAMBD
A
HWS15/A
OUTPUT DERATING
A224-01-02/A
LOAD
(
%
)
Ta
(
°C
)
-10 ~+40
50
60 20
MOUNTING A,B,C,
D
100
60
MOUNTING
B
MOUNTING
C
MOUNTING
D
DON'T USEMOUNTING
A
(
STANDARD MOUNTING
)
OUTPUT DERATING CURVE
0
20
40
60
80
100
120
-100 10203040506070
Ta(°C)
LOAD(%)
MOUNTING A,B,C,D