3
6. Operating temperature: -40 to +125 The part temperature (ambient temperature +
temperature rise) should not exceed the upper limit of the operating temperature under worst
case operating conditions. Circuit design, component placement, PWB trace size and
thickness, airflow and other cooling provisions all affect the part temperature. Part temperature
should be verified in the end application.
7. The Volt-time product is 34.2 V-usec typical.
°C°C.
ELECTRICAL SPECIFICATION @25 C:°
Turns Ratio(5-8):(1-4)
Polarity
DCR(5-8)
DCR(1-4)
SRF
PARAMETERS UNIT LIMITS
1 : 1 ± 1%
Per Schematic
1.39 Min
2250 Min
21.9 Max
Vdc
uH
uH
296.0 Min
1.5 Max
-
-
W
W
MHz
pF
Inductance, Ls(5-8)@100kHz, 0.1Vrms
LL(5-8), short 1+4@100kHz, 0.1Vrms
Hipot(5-8):(1-4)
Cww(5-8):(1-4)@100kHz, 1Vrms
SCHEMATIC
1
4
8
5
0.795 Max
0.655 Max
Pri Sec
E & E Magnetic Products Ltd.
DRAWING NO./MODEL
SCALE PAGE OF
834-00046
DO NOT SCALE 4
02
REV