s SIMATIC Product Information 07/2008 For the programming manual from PROFIBUS DP to PROFINET IO, Edition 10/2006, A5E00298268-03 This product information contains important information on new and revised diagnostics data records. The Product Information is part of the supplied product and the statements made therein are binding in case of doubt. (A) . Copyright (c) Siemens AG 2008 Siemens Aktiengesellschaft A5E01648459-01 For chapter 5 "Data records for PROFINET IO" Overview of relevant data records for PROFINET IO The following information is an addendum to the manual, section 5.1.2 . Data records on the status of PROFINET interfaces Data record number Content and meaning Size in bytes W#16#802A The data record supplies the latest port settings. 0 - 4176 W#16#802B / The data record supplies the configured port settings. 0 - 4176 The data record supplies the configured settings for the 0 - 4176 W#16#802F W#16#802D synchronization. W#16#8060 The data record supplies the latest settings of the optical port. 0 - 4176 W#16#8061 / The data record supplies the configured settings of the optical port. 0 - 4176 The data record supplies the configured settings of the PROFINET 0 - 4176 W#16#8061 W#16#8070 interface. W#16#8080 The data record supplies the latest settings of the PROFINET 0 - 4176 interface. W#16#F831 The data record supplies the collective data record for the configured 0 - 4176 settings of the PROFINET interface and its ports (settings of the IRT parameters only). W#16#F841 The data record supplies the collective data record for latest settings 0 - 4176 of the PROFINET interface and its ports. W#16#F842 The data record supplies the collective data record for the configured 0 - 4176 settings of the PROFINET interface and its ports. 2 Product Information A5E01648459-01 Additional information Detailed information on data records are available in the PROFINET specification "Application Layer services for decentralized periphery and distributed automation" and "Application Layer protocol for decentralized periphery and distributed automation" in version V2.2 on the Internet pages of the PROFIBUS user organization under www.profinet.com. Blocks of diagnostics and configuration data records The following information is an addendum to the manual, section 5.5.9, table 5-23. Coding of ExtChannelErrorType for ChannelErrorType "Incorrect neighborhood" Value (hexadecimal) W#16#0000 W#16#0001 - W#16#7FFF Meaning Reserved Manufacturer-specific W#16#8000 Incorrect neighbor - device W#16#8001 Incorrect neighbor - port W#16#8002 Neighbor does not support RealTime Class 3 or is not configured W#16#8003 Error due to incorrect interface setting - full duplex and half duplex W#16#8004 Incorrect or missing media redundancy configuration W#16#8005 No neighbor present W#16#8006 Neighbor does not support smooth media redundancy W#16#8007 Error due to difference in determining cable length W#16#8008 Same Sync domain name used in several instances / several Sync masters exist W#16#8009 - W#16#8FFF Reserved W#16#9000 - W#16#9FFF Reserved for profiles W#16#A000 - W#16#FFFF Reserved Product Information A5E01648459-01 3 Coding of ExtChannelErrorType for ChannelErrorType "Synchronization error" and "Error time basis"; table 5-25 in manual Value (hexadecimal) W#16#0000 W#16#0001 - W#16#7FFF W#16#8000 W#16#8001/ W#16#8002 W#16#8003 4 Meaning Reserved Manufacturer-specific Sync slave no longer synchronized Reserved Synchronization error W#16#8004 - W#16#8FFF Reserved W#16#9000 - W#16#9FFF Reserved for profiles W#16#A000 - W#16#FFFF Reserved Product Information A5E01648459-01 User Structure Identifier The following information is an addendum to the manual, section 5.5.16, table 5-42 in the manual. Coding of USI (UserStructureIdentifier) Value (hexadecimal) Meaning Description W#16#0000 - W#16#7FFF Manufacturer-specific In connection with Alarm Type diagnostics incoming/going manufacturer-specific Diagnostics in AlarmNotification and Diagnosis Data. In connection with other Alarm Types, the use is manufacturerspecific. W#16#8000 ChannelDiagnosis Use in connection with ChannelDiagnosis in AlarmNotification and Diagnosis Data. W#16#8001 Multiple Only in connection with data that correspond to the structure of "(BlockHeader, Data*)*." BlockType still corresponds with the used AlarmType. W#16#8002 ExtChannelDiagnosisData Use only in connection with ChannelDiagnosisWithAddInfo in AlarmNotification and Diagnosis Data. W#16#8003 Qualified Graduated extended channel diagnostics W#16#8004 - W#16#80FF Reserved W#16#8100 Maintenance W#16#8101 - W#16#81FF Reserved W#16#8200 Reserved W#16#8201 iParameter - W#16#8202 - W#16#8FFF Reserved W#16#9000 - W#16#9FFF Reserved for profiles W#16#A000 - W#16#FFFF Reserved Maintenance Reserved for profiles Product Information A5E01648459-01 5 6 Product Information A5E01648459-01