General Purpose Relay G7L 305
General Purpose Relay
G7L
Ideally suited for high-inrush fluid pump controls: pool/spa, water
processing, emergency, chemical industry, etc.
High-capacity,
high-withstand
voltage relay with no contact chatter-
ing for momentary voltage drops up to 50% of rated voltage.
UL Class B construction standard.
Wide-range AC-activated coil that handles 100 to 120 VAC at either
50 or 60 Hz.
Miniature hinge for maximum switching capacity, particularly for in-
ductive loads.
Flame resistant materials (UL94V-0-qualifying) used for
all insulation material.
Quick-connect, screw, and PCB terminals available.
Standard models are UL, CSA, and TUV approved;
VDE/IEC 950 versions are now available. Meet pollution degree 3,
Material Group II & III.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.
2. For VDE approved versions, please consult OMRON.
Type Contact form Model
Quick-connect terminal Screw terminal PCB terminal
E bracket (see note 1) SPST-NO G7L-1A-T-CB G7L-1A-B-CB
DPST-NO G7L-2A-T-CB G7L-2A-B-CB
E bracket (see note 1)
(with test button)
SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB —
DPST-NO G7L-2A-TJ-CB G7L-2A-BJ-CB
Upper bracket SPST-NO G7L-1A-TUB-CB G7L-1A-BUB-CB
DPST-NO G7L-2A-TUB-CB G7L-2A-BUB-CB
Upper bracket
(with test button)
SPST-NO G7L-1A-TUBJ-CB G7L-1A-BUBJ-CB
DPST-NO G7L-2A-TUBJ-CB G7L-2A-BUBJ-CB
PCB mounting SPST-NO G7L-1A-P-CB
DPST-NO G7L-2A-P-CB
306 General Purpose Relay G7L
Model Number Legend
Accessories
Quick-connect Terminals
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.
Screw Terminals
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.
Specifications
Contact Data
Note: P level: λ60 = 0.1 x 10-6 operation.
Coil Internal Circuit
G7L- ❏❏-❏❏❏❏
12 3456
1. Contact form 3. Mounting construction 5. 80: VDE approved version
1A:SPST-NO No symbol:E bracket type (includes UL, CSA and TÜV)
2A:DPST-NO UB:Upper bracket type
6. CB: Class B insulation
2. Terminal shape 4. Special functions
T:Quick-connect terminals No symbol:Without test button 7. Rated coil voltage
P:PCB terminals J:With test button
B:Screw terminals
Description Model Model
Contact form
SPST-NO DPST-NO
E-brackets G7L-1A-T G7L-1A-TJ G7L-2A-T G7L-2A-TJ R99-07G5D
Track mounting adaptor P7LF-D
Front connecting socket P7LF-06
Description Model Model
Contact form
SPST-NO DPST-NO
E-brackets G7L-1A-B G7L-1A-BJ G7L-2A-B G7L-2A-BJ R99-07G5D
Track mounting adaptor P7LF-D
Terminal Cover P7LF-C
Load G7L-1A-T, G7L-1A-B G7L-2A-T, G7L-2A-B G7L-1A-P, G7L-2A-P
Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4) Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4) Resistive load
(cosφ = 1) Inductive load
(cosφ = 0.4)
Rated load 30 A, 220 VAC 25 A, 220 VAC 20 A, 220 VAC
Contact material AgSnIn
Carry current 30 A 25 A 20 A
Max. operating voltage 250 VAC
Max. operating current 30 A 25 A 20 A
Max. switching capacity 6,600 VA 5,500 VA 4,400 VA
Min. permissible load 100 mA, 5 VDC (please inquire for lower minimum rating)
DC operating coil AC operating coil
General Purpose Relay G7L 307
Coil Data
AC
DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated cur-
rent and ±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).
Characteristics
Note: Data shown are of initial value.
Rated voltage
(V) Rated current
(mA) Resistance
(Ω)Must operate Must release Max. voltage Power
consumption
% of rated voltage
6 283 18.90 75% max. 15% min. 110% max. Approx.1.70
to 2.50 VA
12 142 75
24 71 303
50 34 1,310
100/120 17.00/20.40 5,260 75 volts 18 volts 132 volts
200/240 8.50/10.20 21,000 150 volts 36 volts 264 volts
Rated voltage
(V) Rated current
(mA) Resistance
(Ω)Must operate Must release Max. voltage Power
consumption
% of rated voltage
6 317 18.90 75% max. 15% min. 110% max. Approx.1.90 W
12 158 75
24 79 303
48 40 1,220
100 19 5,260
Contact resistance 50 mΩ max.
Operate time 30 ms max.
Release time 30 ms max.
Max. operating
frequency Mechanical 1,800 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)
Impulse withstand voltage Between coil and contact: 10,000 V min./12,000 V typ. (impulse wave used: 1.20 x 50 μs)
Vibration Mechanical
durability 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Malfunction
durability 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Shock Mechanical
durability 1,000 m/s2 (approx. 100 G)
Malfunction
durability 1,000 m/s2 (approx.10 G)
Life expectancy Mechanical 1,000,000 operations min. (at 1,800 operations/hour)
Electrical 100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)
Ambient temperature -25° to 60°C (-13° to 140°F)
Humidity 35% to 85% RH
Weight Quick-connect terminal type: approx. 90 g (3.17 oz)
PCB terminal type: approx. 100 g (3.52 oz)
Screw terminal type: approx. 120 g (4.23 oz)
308 General Purpose Relay G7L
Characteristic Data
Dimensions
Unit: mm (inch)
Relays
G7L-1A-T
(E Bracket Attached)*
G7L-2A-T
(E Bracket Attached)*
* E bracket must be ordered separately.
Maximum switching capacity Electrical service life
Switching current (A)
Service life (x 103 operations)
Switching voltage (V)
Switching current (A)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
General Purpose Relay G7L 309
G7L-1A-TJ
(E Bracket Attached)*
G7L-2A-TJ
(E Bracket Attached)*
G7L-1A-TUB
G7L-2A-TUB
*E bracket must be ordered separately.
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
310 General Purpose Relay G7L
Unit: mm (inch)
G7L-1A-TUBJ
G7L-2A-TUBJ
G7L-1A-B
(E bracket Attached)*
G7L-2A-B
(E bracket Attached)*
* E bracket must be ordered separately.
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
General Purpose Relay G7L 311
G7L-1A-BJ
(E bracket Attached)*
G7L-2A-BJ
(E bracket Attached)*
G7L-1A-BUB
G7L-2A-BUB
* E bracket must be ordered separately.
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
312 General Purpose Relay G7L
Unit: mm (inch)
G7L-1A-BUBJ
G7L-2A-BUBJ
G7L-1A-P
G7L-2A-P
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
General Purpose Relay G7L 313
Accessories
E bracket
R99-07G5D
Adaptor
P7LF-D
Front connecting socket
P7LF-06
Note: 1. To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket.
2. The P7LF-06 is panel or track mountable.
Mounting holes
(Bottom view)
Mounting holes
(Bottom view)
Mounting holes
(Bottom view)
314 General Purpose Relay G7L
Unit: mm (inch)
Cover
P7LF-C
Note: P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals.
Mounting track
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.
2. L = Length
PFP-100N L = 1 m (39.00 in)
PFP-50N L = 50 cm (19.60 in)
PFP-100N2 L = 1 m (39.00 in)
End plate
PFP-M
Spacer
PFP-S
4.5
15 25 25 25 25
*
10 10
1000 (500)*
7.3±0.15
35±0.3 27±0.15
15 (5) 1
4.5
15 25 25 25 25 15
10 10
1000±4
35±0.3 27 24
16
29.2
1 1.5
* The figure in parenthesis is for PFP-50N.
PFP-100N, PFP-50N
(Conforming to EN 50022)
PFP-100N2
(Conforming to EN 50022)
General Purpose Relay G7L 315
Approvals
UL Recognized (File No. E41643) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C
Note: Contact Omron for actual ratings marked on G7L relays
TÜV (File No. R9251551)
VDE recognized type (Licence no. 1530 UG)
Note: 1. Please consult OMRON for details of VDE approvals.
2. The G7L relay conforms to the following standards: Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83
DIN VDE 0435 Teil 201 A1/05. 90
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81
DIN EN 60 950/VDE 0805/11. 93
EMC: prEN 50082-2, EN 55022
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
4. In the interest of product improvement, specifications are subject to change.
5. Suffix T130 rated at 130°C
6. Pollution degree 3, Material Group II & III.
Type Contact form Terminal type Contact ratings
G7L-1A-T-CB
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
SPST-NO Quick-connect 30 A, 277 VAC, General Use, 100,000 ops
1.5 kW, 120 VAC, Tungsten, 6,000 ops
1.5 HP, 120 VAC, 6,000 ops
3 HP, 277 VAC, 6,000 ops
20 FLA/120 LRA, 120 VAC, 30,000 ops
17 FLA/102 LRA, 265 VAC, 30,000 ops
TV-10, 120 VAC, 25,000 ops
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
Screw
G7L-1A-P-CB PCB
G7L-2A-T-CB
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
DPST-NO Quick-connect
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
Screw
G7L-2A-P-CB PCB
Type Contact form Coil ratings Terminal type Contact ratings
G7L-1A-T-CB
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
SPST-NO 6, 12, 24, 48,
100, 110, 200,
220 VDC
Quick-connect 25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
12, 24, 50,
100/120, 200/240
VAC
Screw 30 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
30 A, 240 VAC, (cosφ = 0.4)
G7L-1A-P-CB PCB 20 A, 240 VAC, (cosφ = 1)
20 A, 240 VAC, (cosφ = 0.4)
G7L-2A-T-CB
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
DPST-NO Quick-connect 25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
Screw 25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
G7L-2A-P-CB PCB 20 A, 240 VAC, (cosφ = 1)
20 A, 240 VAC, (cosφ = 0.4)
316 General Purpose Relay G7L
Precautions
Handling
To preserve initial performance, do not drop or otherwise subject
the power relay to shock.
The case is not designed to be removed during normal handling
and operation. Doing so may affect performance.
Use the power relay in a dry environment free from excessive dust,
SO2, H2S, or organic gas.
Do not allow a voltage greater than the maximum allowable coil
voltage to be applied continuously.
Do not use the power relay outside of specified voltages and cur-
rents.
Do not allow the ambient operating temperature to exceed the
specified limit.
Installation
Although there are not specific limits on the installation site, it
should be as dry and dust-free as possible.
PCB terminal-equipped relays weigh approximately 100 g. Be sure
that the PCB is strong enough to support them. We recommend
dual-side through-hole PCBs to reduce solder cracking from heat
stress.
Quick-connect terminals can be connected to fast on receptacle
#250 and positive-lock connectors.
Allow suitable slack on leads when wiring, and do not subject the
terminals to excessive force.
Cleaning PCB Terminals
PCB terminals have semi-sealed construction which prevents flux
from entering the relay base. It is recommended that the user
should apply a tape seal over the vent hole prior to wave soldering
or cleaning. The tape should then be removed after processing.
Operating Coil
As a rule, either a battery or a DC power supply with a maximum
5% ripple is used for the operating voltage for DC relays. Before
using a rectified AC supply, confirm that the ripple is not greater
than 5%. Ripple greater than this can lead to variations in the oper-
ating and reset voltages.
As excessive ripple can generate beats, the insertion of a
smoothing capacitor is recommended as shown below.
When driving a transistor, check the leakage current and connect a
bleeder resistor if necessary.
Momentary voltage drops on coil input voltage should not exceed
one second duration after contact mating with no shock or vibra-
tion.
Applications
Compressors for package air conditioners and heater switching
controllers
Switching controllers for power tools or motors
Power controllers for water heaters
Power controllers for dryers
Lamp control, motor drivers, and power supply switching in copy
machines, facsimiles, and other OA equipment
Lighting controllers
Power controllers for packers or food processing equipment
Magnetron control in microwaves
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
14
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.
JJ055-E3-04 06/09 Note: Specications are subject to change. © 2010 Omron Electronics LLC
OMRON CANADA, INC. • HEAD OFFICE


OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE

OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE

OMRON ARGENTINA • SALES OFFICE

OMRON CHILE • SALES OFFICE

OTHER OMRON LATIN AMERICA SALES

OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS
OMRON EUROpE B.V.
