1
AXIAL COLOR CODE CAPACITOR
HOW TO ORDER
ACC F104 M500 P26
ABCDEFG
A
Product Type
Code
ACC
Type
Axial Color Code Capacitors
C
Nominal Capacitance
For example
104=100000pF
5R6=5.6PF
B
Temperature Characteristics
CG
CH
RH
UJ
SL
B
YF
0 30PPm/
0 60ppm/
-220 60PPm/
-750 120ppm/
+140~-1000PPm/
10%
15%
-55~+125
-25~+85
-25~+85
-25~+85
-25~+85
-25~+85
-55~+125
-25~+85
D
Tolerance
B
C
D
F
G
J
K
M
N
S
Z
P
B.C.D C 10PF
B.C.D for C 10PF
0.10pF
0.25pF
0.5pF
1.0%
2.0%
5.0%
10%
20%
30%
+50% -20%
+80% -20%
+100% -0%
E
Rated Voltage
250=25V
500=50V
101=100V
G
Lead Configuration
26
52
2
3
4
26mm
Tape width:
52mm
Tape width:
5.08mm
5.08mm pitch formed lead
7.5mm
7.5mm pitch formed lead
10mm
10mm pitch formed lead
Packaging Style
Tape
&Reel
P
T
Ammo
Reel
F
Bulk
F
First two digits are significant,
and the third is numberof
zeros.
%
+30
-80
For example
First two digits are significant,
and the third is numberof
zeros.
03
H
Nominal Body Size Code
H
03
2
Voltage VS Capacitance
Others can be manufactured by customers' requirement.
Temp. Char. Rated Voltage Available Capacitance Range Capacitance Tolerance
CG
B
CH
RH
UJ
SL
0R5~272
0R5~222
0R5~102
1R5~102
1R0~180
2R2~300
1R0~680
101~224
101~104
101~333
103~125
103~105
103~104
25
50
100
50
50
50
50
25
50
100
25
50
100
K 10%
M 20%
N 30%
C: 0.25pF
D: 0.5pF
J: 5%
K: 10%
M: 20%
M: 20%
N: 30%
Z:-20%~+80%
COLOR CODE MARKING CODE
150 : (1)+ (5)+ (0)
E.g. If nominal capacitance is 150, the color of brown+green+black should be marked.
The width of the first line should be wider than others.
Nominal capacitance(pF)
2 color zone
nd
2 digit
nd
3 color zone
rd
3 digit
rd
1 color zone
st
1 digit
st
Black
Brown
Red
Orange
Yellow
Green
Blue
Purple
Gray
White
Gold
Silver
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
X10 (1)
X 10 (10)
X 10 (100)
X 10 (1000)
X 10 (10000)
X 10 (100000)
0
1
2
3
4
5
X 10 (0.1)
X 10 (0.01)
-
-
1
2
1st color zone 2nd color zone 3rd color zone
AXIAL COLOR CODE CAPACITOR
F(Y)
03 03
0R5~102
0R5~102
1R5~102
1R0~180
2R2~300
1R0~680
101~104
101~104
103~224
103~224
25
50
50
50
50
50
25
50
25
50
3
EXTERNAL DIMENSIONS
DIMENSIONS OF BULK PRODUCTS
Type
(mm)
Dimensions (mm)
L
3.2 Max
DF0.6 d
2.2 Max 5.08 7.5 10
TAPING DIMENSIONS
:mm(UNIT)
Tape Style
26
Tape width:
52
Tape width:
L0 ZL-L
12
26 1.5 0.8Max
+2.0
-1.0
52
1.0Max
1.0Max
H
20 Min
0
1.2Max
1.9 Max
5.08 7.5 10 20 Min
3.0 Max
03 0.42 0.05
0.42 0.05
4
PACKAGING STYLE
TAPE AND REEL
BULK PACKAGING
PACKAGING QUANTITY
AMMO PACKAGING
Tape & Reel Ammo Bulk
5000Pcs 5000Pcs 1000Pcs
Packaging according to customer' s requirement
50PCS/
A
C
B
D
Tape
Type
52
26
Dimension ( 5mm)
ABC
72
72
263
263
D
Label
AXIAL COLOR CODE CAPACITOR
76
55
MLCC
Reliability and Test Methods for General Leaded MLCC
Feature
*, , ().
Miniature size,large capacitance,tape and reel packaging suitable for auto-placement
*,
Epoxy resin coating creates excellent performance in humidity resistance,mechanical strength
and heat resistance
*
Standard size,various lead configuration
Item
Capacitance
(C)
Dissipation
Factor
(DF)
Insulation
Resistance
Class
Class
Class
Class
Class
Technical Specification
Class
within the specified
tolerance.
within the specified tolerance.
C 50pF
R
DF 0.15%
C 50pF
R
DF 1.5 150 / C 7 X10
R
-4
B
Y(F)
DF 3.5%
7.5% C 0.1uF
R
10.0%
1uF C 0.1uF
R
15% C 1uF
R
C 10nF
IR 10000M
C 10nF
C 25nF
IR 4000 M
C25nF
Test Method and Remarks
Capacitance
1000pF
1000PF
Measuring
Frequency
1MHZ 10%
1KHZ 10%
Measuring
Voltage
1.0 0.2V
The capacitor should be pretreated before measured.
(only for class ).
Measuring
Frequency
1KHZ 10%
Capacitance
1000pF
1000pF
MeasuringVoltage
B
1.0 0.2V
Measuring
Frequency
1KHZ 10%
1MHZ 10%
0.3 0.2V
1.0 0.2V
:1KHZ 10%;
Measuring Frequency:
:1.0 0.2V
Measuring Voltage:
Measuring
Voltage
:1KHZ 10%
Measuring Frequency:1kHz 10%
:0.3 0.2V
Measuring Voltage:0.3 0.2V
:
Measuring Voltage:Rated Voltage
:60 5
Duration:60 5s
5
F(Y)
R.C 100 F
R.C 100 F
6
Item
Withstanding
Voltage
Solder
ability
Resistance
to
Soldering
Heat
Technical Specification
No breakdown or damage.
95%
Lead wire shall be at
least95% covered with
a new solder coating.
Item
Class
B
C/C
2.5%or
0.25pF
Whichever
is larger.
10%
20%
Appearance: No
significant abnormality
Test Method and Remarks
Between terminals:
Measuring Voltage:
:5 1
Duration:5 1s
:300%
Class :300% Rated voltage
:250%
Class :250% Rated voltage
/ 50mA
The charge/discharge current is less than 50mA.
Between terminals and body:
:2.5UR :1~5s
Voltage:2.5times rated voltage Duration:1~5s
Small metallic ball method
1mm , 2mm
. .
Smsll metallic balls with 1mm diameters shall be put in a vessel and the be submerged
except 2mm from the top of its component body and the terminals.The test voltage shall
be applied between the short-circuited terminals and the metallic balls.
25% , : 230 5
20.5, : 1.5~2mm,
The lead wire of capacitor is dipping into a25% rosin solution of ethanol and then
into molten solder of 230 5 for 2 0.5s. In both cases the depth of dipping is up
to about 1.5 ~2mm from the terminal body.
LEADED MLCC
: 1.6mm, 1.0 mm PC .
Immersed conditions : Inserted into the PC board(with=1.6mm,hole=1.0mm
diameter)
48 4 hours of recovery under the standard condition.
:,484.
Recovery (Class ): 48 4 hours of recovery under the standard condition after
test.
48 4 .
, :150 ,1 ,
+0
-10
Preconditioning(Class ):1 hour of preconditioning at 150 ,followed by
+0
-10
Y( F)
265 3 6(+1,0) s
Solder temperature: 265 3 Duration: 6(+1,0) s
I242
Recovery: For class I, 4 to 24 hours of recovery under the standard condition
after test.
Item
Terminal
Strength
Temperature
cycle
Technical Specification
Tensile
Strength
Bending
Strength
No abnormality
such as cut lead,or
looseness.
No significant abnormality in
appearance
Capacitance change:
Class :
5% or 0.5pF
Class :
B: 12.5%
Dissipation Factor:
2
Class : Not more than twice of
initial value.
Class :
5.0%B:
12.5% C 0.1uF
R
15.0%(1uF C 0.1uF)
R
17.5%(C 1uF)
R
1000M or 50M F
Insulation Resistance:
Whichever is smaller.
Test Method and Remarks
,2Kg,5s
For axial leaded type,apply a 2.0kg tensile force progressivelyin the
direction to draw terminal,this operation is done over aperiod of 5 sec.
, , 10N, 10 1 .
For radial leaded type, fix the capacitor body,apply the forcegradually to
each lead in the radial direction of the capacitoruntil reaching 10N and
then applied the force for 10 1 seconds.
0.25Kg , 90 , 5s, ,
.2.
Each lead wire shall be subjected to a force of 0.25Kg and then be bent
a angle of 90 degree then returned to initial position. This operation is
done over a period of 5 seconds. Then second bend in the opposite dire
ction shall be made, repeat 2 times.
48 4 .
followed by 48 4 hours of recovery under the standard condition.
:,484.
1.
Recovery: As for Class , 48 4 hours of recovery under the standard condition
after test. And for Class ,1 hour of recovery under the standard condition
after test.
:5
Number of cycle:
Conditions for 1 cycle:
, : 150 ,1 ,
+0
-10
Preconditioning:As for Class dielectric,1hour ofpreconditioning at 150 ,
+0
-10
Step
1
2
3
4
5
()
Temperature ( )
CG/N X7R Y5V
Room Temp.
55 25
Room Temp.
125 85
Room Temp.
()
Time
(min.)
2~3
30
2~3
30
2~3
0
-3
+3
0
7
F (Y) : 30%
YF
8
Itim
High
Temperature
Loading
Test
Solvent
Resistance
Tichnical Specification
No significant abnormality in appearance.
Capacitance Change:
Class :
3% or 0.3pF
Whichever is larger.
Class :
B: 12.5%
Dissipation Factor:
:
Class :Not more than twice of initial value.
Class :
B: 5.0%
12.5% C 0.1uF
R
15.0%(1uF C 0.1uF)
R
17.5%(C 1uF)
R
Insulation Resistance:
Whichever is smaller.
,.
No defects or abnormalities in appearance, and legible
marking.
Test Method and Remarks
Temperature
CG(N)/
125
Y5V
85 +3
0
+3
0
1.5
Applied voltage 1.5 times rated voltage
50mA
The charge/discharge current is less than 50mA.
Recovery Time:
:24 2 ,
Class Dielectric:24 2hours
:48 4
Class Dielectric:48 4hours
1000 +48
0
Duration 1000 hours
+48
0
:23 5
Solvent temperature:
1, 10
,3.
Put the sample intosolvent 1 Min,and then take it out and
brush sample's notation area10 times with pledgt, repeat
3times.
*:
:5~35 , :45~85%, :86~106kPa
*Note on standard condition: standard condition referred to herein should be defined as follows:5 to35 of
temperature,45 to 75% of relative humidity,and 86 to 106kPa of atmospheric pressure.
,:
:25 1 , :48%~52%, :86~106kPa
*When there are questions concerning measurement results: In order to provide correlation data,the test should be
conducted under a condition of 25 degrees plus/minus1 centigrade of temperature, 48% through52% of relative
humidity and 86 through 106kPa of atmospheric pressuure.
LEADED MLCC
F (Y) : 30%
X7R
F (Y):
500M or 25 .F