FUSETRONTM 250V Class RK5 FRN-R -- 250Vac/125Vdc, 110-60A, Dual Element, Time-Delay Fuses Dimensions - in 2" ( 0.31) 3" ( 0.31) 0.56" (0.008) 0.81" (0.008) 1/10 to 30A Description: Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings. Time-delay - 10 seconds (minimum) at 500% of rated current (8 seconds for 110-30A sizes). Catalog Symbol: FRN-R-(amp) (non-indicating) FRN-R-(amp)ID (indicating) Ratings: Volts -- 250Vac, 125Vdc Amps -- 110-60 Amps IR -- 200kA Vac RMS Sym. -- 20kA Vdc Agency Information: Fuse Amps 0-30 CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787 Catalog Numbers (amps) -- Non-indictaing fuses FRN-R-1810 FRN-R-2 FRN-R-214 FRN-R-212 FRN-R-2810 FRN-R-3 FRN-R-3210 FRN-R-312 FRN-R-4 FRN-R-412 FRN-R-5 FRN-R-5610 FRN-R-6 FRN-R-614 FRN-R-7 FRN-R-712 Features: * Provides motor overload, ground fault and short-circuit protection * Helps protect motors against burnout from overloads * Helps protect motors against burnout from single-phasing on three-phase systems * Simplifies and improves blackout prevention (selective coordination) * Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection * The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds. Recommended Fuse Blocks CE, UL Listed, Std. 248-12, Class RK-5, Guide JDDZ, File E4273 FRN-R-110 FRN-R-18 FRN-R-15100 FRN-R-210 FRN-R-14 FRN-R-310 FRN-R-410 FRN-R-12 FRN-R-610 FRN-R-810 FRN-R-1 FRN-R-118 FRN-R-114 FRN-R-1410 FRN-R-112 FRN-R-1610 35 to 60A 35-60 FRN-R-8* FRN-R-9* FRN-R-10* FRN-R-12* FRN-R-15* FRN-R-1712* FRN-R-20* FRN-R-25* FRN-R-30* FRN-R-35* FRN-R-40* FRN-R-45* FRN-R-50* FRN-R-60* 1-Pole H25030-1 R25030-1 H25060-1 R25060-1 2-Pole H25030-2 R25030-2 H25060-2 R25060-2 3-Pole H25030-3 R25030-3 H25060-3 R25060-3 For additional information on the 250 volt fuse blocks, see Data Sheets # 1110 (R250), # 1112 (H250). Fuse Reducers For Class R Fuses Equipment Fuse Clips 60A 100A 200A Desired Fuse (Case) Size Catalog Numbers (Pairs) 250V 30A 30A 60A 60A NO.263-R NO.213-R NO.216-R NO.226-R For additional information on Class R fuse reducers, see Data Sheet # 1118. * Open fuse indication available by inserting the sufix "ID." E.g., FRN-R-15ID. Carton Quantity and Weight Amp Rating 1 10-15 1712-30 35-60 0713 Carton Qty. 10 10 10 BU-SB13730 Page 1 of 3 Data Sheet # 1019 FUSETRONTM 250V Class RK5 FRN-R -- 250Vac/125Vdc, 110-60A, Dual Element, Time-Delay Fuses Time-Current Curves - Average Melt 10 to 614 Amps 1 TIME IN SECONDS AMP RATING CURRENT IN AMPS 0713 BU-SB13730 Page 2 of 3 Data Sheet # 1019 FUSETRONTM 250V Class RK5 FRN-R -- 250Vac/125Vdc, 110-60A, Dual Element, Time-Delay Fuses Time-Current Curves - Average Melt 8 to 60 Amps 810 15 Current-Limitation Curves AMP RATING 30 B 400000 60 300000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS AMP RATING 200000 100000 90000 80000 70000 60000 50000 40000 30000 20000 60A 10000 9000 8000 7000 6000 5000 30A 4000 3000 A TIME IN SECONDS 2000 200000 50000 60000 70000 80000 90000 100000 40000 20000 30000 4000 5000 6000 7000 8000 9000 10000 3000 2000 1000 1000 PROSPECTIVE SHORT-CIRCUIT CURRENT - SYMMETRICAL RMS AMPS CURRENT IN AMPS Current-Limiting Effects Prosp. Let-Through Current S.C.C. (Apparent RMS Symmetrical Vs. Fuse Rating) 30A 60A 5000 1000 2000 10,000 2000 3000 15,000 2000 3000 20,000 2000 4000 25,000 2000 4000 30,000 2000 4000 35,000 2000 4000 40,000 2000 5000 50,000 3000 5000 60,000 3000 5000 70,000 3000 6000 80,000 3000 6000 90,000 3000 6000 100,000 3000 6000 150,000 4000 7000 200,000 4000 8000 The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0713 BU-SB13730 Page 3 of 3 Data Sheet # 1019