cui.com
date 09/15/2016 │ page 2 of 6CUI Inc │ SERIES: SDI65-U │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 1.4 A
inrush current at 240 Vac, full load, 25°C, cold start 80 A
leakage current 3.5 mA
no load power consumption
at 230 Vac
LevelVI
CoC Tier 2
0.21
0.150
W
W
OUTPUT
parameter conditions/description min typ max units
regulation ±5 %
PROTECTIONS
parameter conditions/description min typ max units
overvoltageprotection output latch off 150 %
overcurrentprotection outputshutdown,autorecovery 180 %
short circuit protection outputshutdown,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolationvoltage input to output at 10 mA for 1 minute
input to frame ground at 10 ma for 1 minute
3,000
1,500
Vac
Vac
isolation resistance input to output at 500 Vdc
input to frame ground at 500 Vdc
10
10
MΩ
MΩ
safetyapprovals UL/cUL,GS,PSE,LPS
EMI/EMC FCCPart15BClassB,CE
MTBF asperTelcordiaSR-332,25°C 300,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 80 °C
operatinghumidity non-condensing 20 80 %
storagehumidity non-condensing 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Jacks