LT4H-W Timers DIN 48 SIZE DIGITAL TIMER UL File No.: E122222 CSA File No.: LR39291 8 Pin type 11 Pin type Screw terminal type Features 1. Wide time range The operation time range covers from 0.01 sec. to 999 hours. The individual setting can be performed on each of the timers. 99.99s 99min59s 99h59min 999.9s 999min 999.9h 9999s 9999h 2. Bright and Easy-to-Read Display A brand new bright 2-color back-lit LCD display. The screen is easy-to-read in any location, makes checking and setting procedures a cinch. 3. Simple Operation Seesaw buttons make setting and operation simple and easy. 4. Short Body of only 64.5 mm 2.54 inch (screw terminal type) or 70.1 mm 2.76 inch (pin type) With a short body, it is easy to install even in shallow control panels. 5. Conforms to IP66's Weather Resistant Standards The water-proof front panel keeps out water and dirt for reliable operation even in poor environments. 6. Screw terminal and Pin Type are Both Standard The two terminal types are standard to support either through-panel installation or embedded installation. 7. Changeable Panel Cover A black panel cover is also available to meet your design requirements. 8. Conforms With EMC and Low Voltage Directives Conforms with EMC directives (EN50081-2/EN50082-2) and low-voltage directives (VDE0435/Part 2021) for CE certification vital for use in Europe. 9. EE-PROM Power Failure Memory EE-PROM memory retains setting and time data. Eliminates the need for battery replacement. Product types Time range Operation mode Output Operation voltage Power down insurance 100-240 V AC Relay (1 c) 99.99s 999.9s 9999s 99min59s 999.9min 99h59min 999.9h 9999h Pulse input: * Delayed one shot * OFF-start flicker * ON-start flicker Integrating input: * Delayed one shot OFF-start flicker * ON-start flicker 24 V AC 12-24 V DC Available 100-240 V AC Transistor (1 a) 24 V AC 12-24 V DC Terminal Part No. 8 pin LT4HW8-AC240V 11 pin LT4HW-AC240V Screw LT4HW-AC240VS 8 pin LT4HW8-AC24V 11 pin LT4HW-AC24V Screw LT4HW-AC24VS 8 pin LT4HW8-DC24V 11 pin LT4HW-DC24V Screw LT4HW-DC24VS 8 pin LT4HWT8-AC240V 11 pin LT4HWT-AC240V Screw LT4HWT-AC240VS 8 pin LT4HWT8-AC24V 11 pin LT4HWT-AC24V Screw LT4HWT-AC24VS 8 pin LT4HWT8-DC24V 11 pin LT4HWT-DC24V Screw LT4HWT-DC24VS 23 Part names T1/T2 Operation display Controlled output indicator T1 OP. T2 LOCK 1 2 3 4 5 6 7 8 Set time display h m s Time units display UP RESET DIP switches Elapsed time display T1 T2 Lock indicator Reset switch (Subtraction elapsed time display) LT4H-W ON Display for change-over between T1/T2 settings TIMER Up keys SET/LOCK Set/Lock switch Down keys DOWN Fourth digit (Same for 8-pin and screw terminal type) First digit Specifications Item Operating voltage Frequency Power consumption Control capacity (resistive) Time range Time counting direction Rating Operation mode Signal, Reset, Stop input Lock input Input signal Time accuracy (max.) Contact Indication Power failure memory method Operating time fluctuation Temperature error Voltage error Setting error Contact arrangement Initial contact resistance Contact material Mechanical Life Electrical Operating voltage range Initial breakdown voltage Electrical Mechanical Operating conditions Initial insulation resistance (At 500 V DC) Operating voltage reset time Temperature rise Functional Vibration resistance Destructive Functional Shock resistance Destructive Ambient temperature Ambient humidity Air pressure Ripple rate Connection Protective construction 24 Ralay output type Transistor output type AC type DC type AC type DC type 12 to 24 V DC 100 to 240 V AC / 24 V AC 100 to 240V AC 12 to 24 V DC -- 50/60 Hz common 50/60 Hz common -- Max. 3 W Max. 10 V A Max. 10 V A Max. 3 W 5 A, 250 V AC 100 mA, 30 V DC 99.99s, 999.9s, 9999s, 99min59s, 999.9min, 99h59min, 999.9h, 9999h (selected by DIP switch) Addition (UP)/Subtraction (DOWN) (2 directions selectable by DIP switch) Pulse input: Delayed one shot, OFF-start flicker or ON-start flicker Integrating input: Delayed one shot, OFF-start flicker or ON-start flicker Min. input signal width: 1 ms, 20 ms (2 directions by selected by DIP switch) Min. input signal width: 20 ms Open collector input Input impedance: Max. 1 k; Residual voltage: Max. 2V Open impedance: 100 k or less, Max. energized voltage: 40 V DC 7-segment LCD, Elapsed value (backlight red LED), Setting value (backlight yellow LED) EE-PROM (Min. 105 overwriting) (0.005% + 50 ms) in case of power on start (0.005% + 20 ms) in case of reset or input signal start (at fixed power off time) Timed-out 1 Form C 100 m (at 1 A 6 V DC) Ag alloy/Au flash Timed-out 1 Form A (Open collector) -- -- 2.0 x 107 ope. (Except for switch operation parts) -- 1.0 x 10 ope. (At rated control voltage) 1.0 x 10 ope. (At rated control voltage) 5 7 85 to 110 % of rated operating voltage 2,000 Vrms for 1 min: Between live and dead metal parts 2,000 Vrms for 1 min: Between live and dead metal parts 2,000 Vrms for 1 min: Between input and output 2,000 Vrms for 1 min: Between input and output 1,000 Vrms for 1 min: Between contacts Between live and dead metal parts Min. 100 M: Between live and dead metal parts Min. 100 M: Between input and output Between input and output Between contacts Max. 0.5 s -- Max 65 C (under the flow of nominal operating current at nominal voltage) 10 to 55 Hz: 1 cycle/ min single amplitude of 0.35 mm .014 inch (10 min on 3 axes) 10 to 55 Hz: 1 cycle/ min single amplitude of 0.75 mm .030 inch (1 h on 3 axes) Min. 98 m 321.522 ft./s2 (4 times on 3 axes) Min. 294 m 964.567 ft./s2 (5 times on 3 axes) -10 C to 55 C +14 F to +131 F Max. 85 % RH 860 to 1,060 h Pa 20 % or less -- 20 % or less 8-pin/11-pin/screw terminal IP66 (front panel with rubber gasket) Dimensions (units: mm inch) * LT4H-W digital timer Pin type (through-panel or surface mount installation) Screw-down terminal type (through-panel installation) 64.5 2.539 5.5 .217 48 1.890 TIMER 5.5 .217 55.6 2.189 14.5 .571 LT4H-W T1 T2 T1 OP. T2 LOCK h m 44.5 1.752 s 44.5 1.752 UP RESET SET/LOCK DOWN 7.5 .295 7.5 .295 (Same for 8-pin type) * Dimensions for through-panel installation (with adapter installed) Screw-down terminal type Pin type installation panel installation panel Rubber gasket ATC18002 (supplied) TIMER Rubber gasket ATC18002 (supplied) installation frame ATA4811 (supplied) TIMER LT4H-W T1 8-pin type (8p cap AD8013 sold separately) 11-pin type (11p cap ATA4861 sold separately) LT4H-W T1 T2 T2 T1 48 1.890 installation frame ATA4811 (supplied) OP. T2 LOCK h m 50 1.969 s T1 44.5 1.752 66 2.598 48 1.890 T2 LOCK UP RESET 50 1.969 OP. h m s 66 2.598 UP RESET SET/LOCK SET/LOCK DOWN DOWN 63.5 2.500 1 48 1.890 1 48 1.890 * Dimensions for surface mount installations * Installation panel cut-out dimensions * For connected installations The standard panel cut-out dimensions are shown below. Use the installation frame (ATA4811) and rubber gasket (ATC18002). DIN rail terminal block (8-pin type ATC18003 sold separately) (11-pin type ATC18004 sold separately) 45 +0.6 0 1.772 Device installation rail ATA48011 (sold separately) 95.5 (90.0) 3.760 (3.543) +0.6 45 0 +.024 1.772 0 80min. 3.150min. +.024 0 A When n timers are continuously installed, the dimension (A) is calculated according to the following formula (n: the number of the timers to be installed): +0.6 +.024 A=(48 x n - 2.5) 0 A=(1.890 x n - .098) 0 +0.6 0 +.024 0 45 1.772 80min. 3.150min. ( 90 3.543 Note 1: The installation panel thickness should be between 1 and 5 mm .039 and .197 inch. Note 2: For connected installations, the waterproofing ability between the unit and installation panel is lost. ) dimension is for 8-pin type. Terminal layout and wiring * 8-Pin type Relay output type Transistor output type NC Signal Reset 3 2 4 5 1 8 3 2 6 7 Operation (-) voltage (+) Reset Signal Stop Lock 7 8 9 10 1 2 3 4 5 NO 1 8 Reset Signal Stop Lock 6 7 5 6 7 4 3 2 (-) 1 11 Transistor output type NC NO 8 9 10 Operation voltage (+) COM Reset Signal Stop Lock 5 6 7 8 4 9 3 2 10 1 11 (-) Operation voltage (+) Transistor output type COM 6 4 5 Operation (-) voltage (+) COM * Screw terminal type Relay output type Operation (+) voltage (-) Signal Reset NO * 11-Pin type Relay output type NC Reset Signal Stop Lock 6 7 8 9 10 1 2 3 4 5 Operation (+) voltage (-) 25 Setting the operation mode, timer range, and time Setting procedure 1) Setting the operation mode and timer range (Timer T1/Timer T2) Set the operation mode and timer range with the DIP switches on the side of the unit. DIP switches Table 1: Setting the timer range (Timer T1) Note: Set the DIP switches before installing the unit. Item DIP switch OFF ON 1 2 3 Operation mode Refer to table 1 4 Minimum input reset, signal, and stop signal width 20 ms DIP switch No. 1 2 3 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON 1 ms 5 Time delay direction Addition Subtraction 6 Timer range Refer to table 2 7 8 * The 8-pin type does not have the stop input, so that the dip switch can be changed over between reset and signal inputs. The signal range of the lock input is fixed (minimum 20 ms). DIP switch No. 6 7 8 ON ON ON OFF OFF OFF ON OFF OFF OFF ON OFF ON ON OFF OFF OFF ON ON OFF ON OFF ON ON 3 4 5 6 7 8 ON 2 0.01 s to 99.99 s 0.1 s to 999.9 s 1 s to 9999 s 0 min 01 s to 99 min 59 s 0.1 min to 999.9 min 0 h 01 min to 99 h 59 min 0.1 h to 999.9 h 1 h to 9999 h Table 2: Setting the timer range (Timer T2) DIP switches 1 Timer range Timer range 0.01 s to 99.99 s 0.1 s to 999.9 s 1 s to 9999 s 0 min 01 s to 99 min 59 s 0.1 min to 999.9 min 0 h 01 min to 99 h 59 min 0.1 h to 999.9 h 1 h to 9999 h Setting procedure 2) Setting the time Set the set time with the keys on the front of the unit. Front display section Q Elapsed time display W Set time display E T1/T2 operation indicator R T1/T2 setting value selectable indicator T Controlled output indicator Y Lock indicator U Time units display 3 TIMER LT4H-W 1 T1 T2 4 T1 OP. T2 LOCK 5 2 h m s 7 6 UP RESET 8 10 11 SET/LOCK 9 DOWN Fourth digit First digit 1) Setting or changing the operational mode 1. When the UP or DOWN key at the first digit is pressed with the set/lock switch pressed, the mode is changed over to the setting mode. I UP keys Changes the corresponding digit of the set time in the addition direction (upwards) O DOWN keys Changes the corresponding digit of the set time in the subtraction direction (downwards) P RESET switch Resets the elapsed time and the output { Set/lock switch Changes over the display between T1/T2 settings, sets the operational mode, checks the operational mode and locks the operation of each key (such as up, down or reset key). Ex: Setting mode display 2. The operational mode in the setting mode is changed over sequentially in the left or right direction by pressing the up or down key at the first digit, respectively. Pulse input OFF-start One operation Pulse input Pulse input OFF-start ON-start Repeating operation Repeating operation Integrating input OFF-start One operation Integrating input Integrating input OFF-start ON-start Repeating operation Repeating operation 3. The operational mode displayed at present is set by pressing the RESET key, and the display returns to the normal condition. 2) Checking the operational mode When the UP or DOWN key at the second digit is pressed with the set/lock switch pressed, the operational mode can be checked. The display returns to the normal condition after indicating the operational mode for about two seconds. (While the display indicates the operational mode for about two seconds, the other indicators continue to operate normally.) 3) Setting the lock When the UP or DOWN key at the fourth digit is pressed with the set/lock switch pressed, all keys on the unit are locked. The timer does not accept any of UP, DOWN and RESET keys. To release the lock setting, press the UP or DOWN key at the fourth digit again with the set/lock switch pressed. * Operational mode, adding and subtracting and minimum input signal range cannot be set at T1 and T2, respectively. 4) Changing over the T1/T2 setting display The T1/T2 setting display is changed over by pressing the SET/LOCK switch. (This operation gives no effect on the other operations. The set time and elapsed time (residual time) at T1 are linked with those at T2.) * Changing the set time 1. It is possible to change the set time with the up and down keys even during time delay with the timer. However, be aware of the following points. 1) If the set time is changed to less than the elapsed time with the time delay set to the addition direction, time delay will continue until the elapsed time reaches full scale, returns to zero, and then reaches the new set time. If the set time is changed to a time above the elapsed time, the time delay will continue until the elapsed time reaches the new set time. 2) If the time delay is set to the subtraction direction, time delay will continue until "0" regardless of the new set time. 2. When the set times at T1 and T2 are set to 0, the output becomes ON only while the signal input is carried out. However, while the reset input is carried out, the output becomes OFF. 26 PULSE : Pulse input INTEGRATION : Integrating input PULSE A OFF-start/1 operation t1