Actuator
Short push plunger
Cord outlet direction
Part No.
N.C. COM
AZ7400 AZ7401
Push plunger AZ7405 AZ7406
Hinge lever AZ7410 AZ7411
Roller lever AZ7415 AZ7416
One-way roller lever AZ7420 AZ7421
Hinge short lever AZ7425 AZ7426
Short roller lever AZ7430 AZ7431
One-way short roller lever AZ7435 AZ7436
Panel mount push plunger AZ7440 AZ7441
Panel mount roller plunger AZ7445 AZ7446
Panel mount cross roller plunger AZ7450 AZ7451
Flexible rod AZ7460 AZ7461
Actuator Part No.
Short push plunger
Push plunger
Hinge lever
Roller lever
One-way roller lever
Hinge short lever
Short roller lever
One-way short roller lever
Panel mount push plunger
Panel mount roller plunger
Panel mount cross roller plunger
Flexible rod
AZ7100
AZ7110
AZ7120
AZ7121
AZ7124
AZ7140
AZ7141
AZ7144
AZ7310
AZ7311
AZ7312
AZ7166
FEATURES
1. Long life
High efficiency coil spring switching
mechanism for long life: More than 107
mechanical operations.
2. Great mechanical strength while
being compact and lightweight
The attachment pitch is 25.4mm
(1.000inch), same as for the Z basic
model microswitch. Also, the outer cover
cap uses a strong plastic with excellent
mechanical characteristics. An M4 bolt
can be used for the attachment.
3. The overtravel (O.T.) is large with
great shock absorption
4. The switch itself is constructed to
be dust-proof and oil resistant
The switch itself is closed flush with the
diaphragm and the compressed rubber
ring, so that the terminal mold type
(epoxy-sealed terminal type) is perfectly
flush with the terminal parts.
TYPICAL APPLICATIONS
Used in sequence control of food pro-
cessing machines, automatic packaging
machines, conveyers, and processors.
Ideal for light industry machinery when
installation pace is limited and a protec-
tive construction is sought.
PRODUCT TYPE
1. Standard type
Terminal mold types (epoxy-sealed terminal type) also available.
Standard type
(Short roller lever)
Notes) 1. When ordering an overseas-specified product,refer to the foreign
standards overview.
2. Cadmium free contact types are available on a custom-made basis.
Please add an “F” to the end of the part number when ordering.
2. Terminal mold type (epoxy-sealed terminal type)
COMPACT SIZE
LIMIT SWITCHES ML (AZ7)
Limit Switches
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Compliance with RoHS Directive
Partly Order Discontinued as of August 31, 2012
FOREIGN STANDARDS
Standards
SPECIFICATIONS
1. Rating
DATA
1. Life curve
Load
Rated control voltage
2.Characteristics
Resistive load (cos
φ
]1) Inductive load (cos
φ
]0.4) Motor or lamp load
N.C. contact
125V AC 10A 6A 3A 1.5A
250V AC 10A 4A 1.5A 1A
115V DC 0.4A 0.05A
N.O. contact
UL
Applicable product
File No. : E122222
Ratings : 10A 250V AC
Product type : Standard type only
C-UL File No. : E122222
Ratings : 10A 250V AC
Product type : Standard type only
TÜV
Contact arrangement 1 Form C
Initial contact resistance, max.
Contact material
15m* (By voltage drop 6 to 8V DC at rated current)
AgCdO contact
Initial insulation resistance (At 500V DC)
Initial breakdown voltage
Shock resistance In the free position
In the full operating position
Vibration resistance
Expected life
(Min. operation)
Mechanical
Electrical
Ambient temperature/Ambient humidity
Max. operating speed
Min. 100 M
1,500 Vrms for 1 min Between non-consecutive terminals
2,000 Vrms for 1 min Between dead metal parts and each terminal
2,000 Vrms for 1 min Between ground and each terminal
Max. 98m/s2 {10G}
Max. 294m/s2 {30G}
55 Hz, double amplitude of 1.5 mm
107(at 50 cpm)
2 105(at 20 cpm)
–20 to +60°C –4 to +140°F/Max. 95% R.H. (at 20°C 68°F)
120 cpm
File No. : J9551204
Ratings : AC-15 2A/250V~
Product type : Standard type only
Order by standard part No.
Part No.
3.EN60947-5-1 performance
Item Rating
Rated insulation voltage (Ui) 250VAC
Rated impulse withstand voltage (Uimp) 2.5kV
Switching over voltage 2.5kV
Rated enclosed thermal current (Ithe) 10A
Conditional short-circuit current 100A
Short-circuit protection device 10A fuse
Protective construction IP64 (switch)
Pollution degree 3
4. Operating characteristics
Characteristics
Actuator
O.F. (N{gf})
max.
Short push plunger
R.F. (N{gf})
min.
Pretravel
(P.T.), max.
mm inch
Movement
Differential
(M.D.), max.
mm inch
Overtravel
(O.T.), min.
mm inch
5.88 {600} 0.98 {100} 2.0 .079 0.8 .031 0.8 .031
Operating Position
(O.P.) mm inch
30±0.8 1.181±.031
Push plunger 5.88 {600} 0.98 {100} 2.0 .079 0.8 .031 5.0 .197 44±1.2 1.732±.047
Hinge lever 1.47 {150} 0.39 {40} 13.5 .531 3.2 .126 4.0 .157 25±2.0 .984±.079
Roller lever 1.77 {180} 0.49 {50} 11.0 .433 2.4 .094 3.0 .118 40±1.9 1.575±.75
One-way roller lever 1.96 {200} 0.59 {60} 11.0 .433 2.4 .094 3.0 .118 50±2.0 1.969±.079
Hinge short lever 2.16 {200} 0.59 {60} 8.5 .335 2.0 .079 2.5 .098 25±1.3 .984±.051
Short roller lever 2.35 {240} 0.78 {80} 6.5 .256 1.5 .059 2.0 .079 40±1.6 1.575±.063
One-way short roller lever 2.75 {280} 0.98 {100} 6.5 .256 1.5 .059 2.0 .079 50±1.6 1.969±.063
Panel mount push plunger 5.88 {600} 0.98 {100} 2.0 .079 0.8 .031 6.0 .236 21.8±0.8 .858±.031
Panel mount roller plunger 5.88 {600} 0.98 {100} 2.0 .079 0.8 .031 6.0 .236 33.3±1.2 1.311±.047
Panel mount cross roller plunger
5.88 {600} 0.98 {100} 2.0 .079 0.8 .031 6.0 .236 33.3±1.2 1.311±.047
Flexible rod 1.18 {120} 25 .984 11 .433 36 1.417 (T.T.)
5. Protective characteristics
Protective construction Standard type Terminal mold type
(Epoxy-sealed terminal type)
IEC
IP60 
IP64
*The resistance of a copper wire is not included.
Note) For the operating characteristics, refer to the TECHNICAL INFORMATION.
10
A
C
5
V
10
Load current (A)
5
10
5
c
o
s
1
1
7
6
10
8
10
2
Operations (104)
φ
WIRING DIAGRAM
Standard type
N.O.
ML
COM
N.C.
Circuit
COM N.O. N.C.
Terminal
ML (AZ7)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2012
DIMENSIONS
• Short push plunger
(P.T.) 2 max.
16.5 max.
14.3
54±0.2
25.4±0.15 4.2±0.2 dia.
23.3±0.3
16 dia. (O.P.)
(25)
17±0.8
21.4
7 dia.
.650
2.126±.008
1 inch
.917±.012
.630
.563
30±0.8
(.984)1.181±.031
.669±.031
.079
12 dia.
.276
.472
.843
• Push plunger
14.3
54±0.2
25.4±0.15 4.2±0.2 dia.
16 dia.
(O.P.)
(25)
17±0.8
2.126±.008
1 inch
.630
.563
44±1.2
(.984)
.669±.031
.472
12 dia.
8 dia.
.843
21.4
(P.T.) 2 max.
.079
.917±.012
23.3±0.3
16.5 max.
.650
1.732±.047
.315
AZ7100 AZ7110
General tolerance: ±0.4 ±.016
mm inch
• Hinge lever
63.5±1.0
17±0.8
21.4
(O.P.)
(P.T.) 13.5 max.
8.5±0.1
16.5 max.
14.3
54±0.2
25.4±0.15
.650
2.126±.008
1 inch .563
4.2±0.2 dia.
2.500±.039 .531
.984±.079
.669±.031
25±2.0
.843
.335±.004
• Roller lever
48.35±1.0
12.5 dia.
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
(O.P.)
40±1.9
.843
21.4
8.0
.315
.492
(P.T.) 11.0 max.
.433
4.2±0.2 dia.
.669±.031
17±0.8
1.575±.075
1.904±.039
AZ7120 AZ7121
General tolerance: ±0.4 ±.016
• One-way roller lever
• Hinge short lever
39.2±1.0
16.5 max.
.650
4.2±0.2 dia.
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
8.5±0.1
.335±.004
(P.T.) 8.5 max.
.669±.031
17±0.8
(O.P.)
25±1.3
.984±.051
1.543±.039 .335
21.4
.843
AZ7124 AZ7140
General tolerance: ±0.4 ±.016
ML (AZ7)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2012
• Short roller lever
12.5 dia.
16.5 max.
.650
4.2±0.2 dia.
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.669±.031
17±0.8
(O.P.)
40±1.6
(P.T.)6.5 max.
30.2±1.0
1.189±.039 .256
1.575±.063
21.4
.843
8.0
.492
.315
• One-way short roller lever
AZ7141 AZ7144
General tolerance: ±0.4 ±.016
mm inch
• Panel mount push plunger • Panel mount roller planger
AZ7310 AZ7311
General tolerance: ±0.4 ±.016
• Panel mount cross roller planger
M12(P=1.0)
2-panel mounting nut
Thickness 3.2 .126
Length of opposite side 17 .669
Teethed washer
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.843
21.4
4.2±0.2 dia.
.669±.031
17±0.8
23.3±0.5
.917±.020
(25)
(.984)
(O.P.)
33.3±1.2
(P.T.) 2 max.
.079
1.311±.047
15.3
.602
12.5 dia.3.8
.492 dia..150
• Flexible rod
(.984)
(1.417)
107.5±1.5
23.3
24.5
(Range of
16 dia.
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.843
21.4
4.2±0.2 dia.
.669±.031
17±0.8
24
17.5
.630
.965
.689
.945
4.232±.059
Pretravel (25)
Total travel (36)
.917
operating
position)
AZ7312
AZ7166
General tolerance: ±0.4 ±.016
15.3
M12(P=1.0)12.5 dia.
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.843
21.4
4.2±0.2 dia.
.669±.031
17±0.8
23.3±0.5
.917±.020
(25)
(.984)
(O.P.)
33.3±1.2
3.8
.150
.492
(P.T.) 2 max.
.079
1.311±.047
.602
2-panel mounting nut
Thickness 3.2 .126
Length of opposite side 17 .669
Teethed washer
M12(P=1.0)(P.T.) 2 max.
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.843
21.4
4.2±0.2 dia.
.669±.031
17±0.8
17
8 dia.
23.3±0.5
.079
.917±.020
.669
.315
(25)
(.984)
(O.P.)
21.8±0.8
.858±.031
2-panel mounting nut
Thickness 3.2 .126
Length of opposite side 17 .669
Teethed washer
OPERATING DIRECTION
(O.P.)
10
(F.P.)
12.5 dia.
16.5 max.
.650
25.4±0.15
54±0.2
2.126±.008
1 inch .563
14.3
.843
21.4
8.0
.492
.315
.394
50±1.6
55±1.6
UNOPERATING
DIRECTION
S
w
i
v
e
l
4.2±0.2 dia.
.669±.031
17±0.8
2.165±.063
1.969±.063
30.2±1.0
1.189±.039
a
n
g
l
e
9
0°
m
a
x
ML (AZ7)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2012
Terminal Mold Type (Epoxy-Sealed Terminal Type)
The waterproof type (IP64) has its terminals sealed with epoxy resin.
1. Type of product
All the standard type have this epoxy-sealed
terminal types.
2. Appearance
The dimensions are the same as
those of the standard type.
The cord outlet is located either at
the N.C. or COM side.
The cord is 1 m 3.281ft. long.
1. Ambient conditions
1) When the switch is to be used in
places where oil or is abundant, bore a
drain hole in the bottom of the terminal
cover.
2) Avoid places where highly acid or
alkaline fluids are used or high tempera-
tures prevail.
3) This model uses silver terminals.
Therefore, if used at relatively low fre-
quencies for long periods of time, or if
used with very small loads, the oxidiza-
tion that forms on the contact surfaces
will not wear away and eventually cause
improper contact. For such applications,
use limit switches with gold/metal con-
tacts (e.g. VL limit switches) or ones
meant for small loads (e.g. HL limit
switches).
4) This switch is not designed for under-
water use. Do not use the unit under-
water.
5) To improve reliability during actual
use, it is recommended that the opera-
tion be checked under installation condi-
tions.
6) If OT is too big, the life of limit switch
will be shortened switching friction. Use it
with enough margin of OT. 70% of OT
standard value will be good for use.
7) Do not use the switch in a silicon
atmosphere. Case should be taken
where organic silicon rubber, adhesive,
sealing material, oil, grease or lead wire
generates silicon.
8) Avoid use in excessively dusty envi-
ronments where actuator operation
would be hindered.
9) When used outdoors (in places where
there is exposure to direct sunlight or
rain such as in multistory car parks) or in
environments where ozone is generated,
the influence of these environments may
cause deterioration of the rubber materi-
al. Please consult us if you intend to use
a switch in environments such as these.
10) Do not store in places where organic
gas might be generated or in places of
high dust content or high humidity.
2.Mounting and wiring
1) Remove the terminal cover with a v
driver. Insert the lead wire through the
knock-out of the terminal cover.
(The terminal cover of the epoxy-sealed
terminal type is filled with resin. It cannot
be removed.)
2) Connect the lead wire to the terminal.
When connecting the terminals with the
fasten lug, those with the insulation
sleeve are recommended.
Tightening torque: 1.18 to 1.47 N·m {12
to 15 kg·cm}
3) The terminal cover can be mounted in
both directions.
• In this case, fasten the terminal cover in
the opposite direction.
• Side mounting
To mount onto a side, use M4 screws
with washers and secure it firmly. The
tightening torque should be 1.18 to 1.47
N·m (12 to 15 kg·cm).
• Panel mounting
(panel mount plunger type)
When installing the panel mounting type
onto a panel, the tightening torque for
the hex. nut should be 7.84 N·m (80
kg·cm).
• For terminal mold types (epoxy-sealed
terminal types), there are two types by
the cord outlet direction; N.C. side and
COM side.
3. Flexible rod
1) Put the detective object to the tip of
plastic part.
2) Avoid pushing the tip of actuating
spring in the direction of axis. In the
places of oil or water splashes and much
dust area, use the limit switch with keep-
ing the actuating spring in the vertical
direction.
CAUTIONS
COM terminal
N.O. terminal
N.C. terminal
3-core vinyl cabtire cable
Epoxy resin filled up for reliable watertightness
and heat resistance.
Cord outlet direction: N.C. Cord outlet direction: COM
• Cord specifications
Type Vinyl cabtire cable (VCT)(3 ×1.25mm2)
Cord length
Lead colors
1m 3.281ft.
Black: COM
Red: N.C.
White: N.O.
Standard type
N.C. COM
ML (AZ7)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.