14 NEC TOKIN Sensors Vol.03
Zero-Phase Current Transformers ZCT
Outline
The ZCT Series of compact molded-type zero-phase
current transformers is ideal for improving the sensitiv-
ity, compactness and light weight of electric shock pre-
vention earth leakage breakers.
Applications
Electric shock prevention earth
leakage breakers.
Short circuit relays.
Shape and Dimensions
Features
•High sensitivity.
•Compact and light weight.
Laminated iron core type.
Specifications
Spare solder
<5>
H LD3
[5.0]
D1
D2
H(5) A
D1
D3
B
D2
Pin
MR-1,2,3,4 MR-1-P3,P5
Each part's dimensions (mm)
Product name D1 (±0.3) D2 (±0.3) D3 (±0.4) H L (±3.0) A (±0.3) B (±0.3)
MR-1 7.5 19.0 22.0 8.0±0.3 40.0
MR-2 9.2 21.5 24.3 8.0±0.3 80.0
MR-3 12.0 27.0 30.0 10.0±0.3 67.0
MR-4 17.0 31.3 33.7 10.5±0.3 67.0
MR-1-P3 7.7 19.0 21.0 8.5 max. 3.0 10.0
MR-1-P5 7.7 19.0 21.5 8.5 max. 5.0 10.5
Pin : 0.8
φ
solder-plated wire
MR-1 30
MR-2 30
MR-3 60 810±10 13 R=0.3 k
MR-4 125 Io=22.5 mA
MR-1-P3 30
MR-1-P5 30
Note:)We can accommodate other specifications as well, so please ask if required. R : Output load, Io = Io : Detection current
Overload Temperature Unbalance Measurement
Product name Rated current Output voltage characteristics characteristics characteristics conditions
(–20°C to 80°C) (rated load)
(A) (mV) min. (%) max. (%) max. (%) max.
NEC TOKIN Sensors Vol.03 15
Before Using Zero-Phase Current Transformers ZCT
Strong shocks such as from being dropped may change the characteristics. Take care to avoid any subjecting
the transformers to physical shocks.