Data sheet VSSC6 TRLDMOV120VAC/DC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Similar to illustration Overvoltage protection with individual components with varistors in terminal design The metal-oxide varistors can be used in terminal design. They are approved for a maximum sine-wave-form powerfrequency operating voltage, which is printed on the component. Any voltages greater than the permitted maximum are discharged safely within 25 ns. Varistors are used for medium to high power. General ordering data Version Order No. Type GTIN (EAN) Qty. Surge protection for instrumentation and control, 120 V, 170 V, 12 A, IEC 61643-21 1064840000 VSSC6 TRLDMOV120VAC/DC 4032248830091 5 pc(s). Creation date February 20, 2021 5:45:14 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 1 Data sheet VSSC6 TRLDMOV120VAC/DC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth Height Net weight Width (inches) 81 mm 88.5 mm 62.8 g 0.488 inch Depth (inches) Height (inches) Width 3.189 inch 3.484 inch 12.4 mm -40 C...80 C 5...96 % Operating temperature -40 C...70 C SIL Paper 3,085 Jahre SIL in compliance with IEC 61508 SFF 3 97.57 % Lead 7439-92-1 E311081 UL certificate UL Zertifikat IIB IIC 212 V 0 H Gas group D Input current, max. II Internal capacity, max. CI IIA 12 A 2 nF black Yes IP20 Design Optical function display Rail Testing option Version Terminal Yes TS 35 Functional screw with test plug receptacle, connections 1, 2, 4, 5 Surge protection for measurement and control Surge voltage category Temperatures Storage temperature Humidity Probability of failure SIL PAPER MTTF ges 37 PFH in 1*10-9 per hour 0.9 Environmental Product Compliance REACH SVHC Rated data UL Certificate No. (UL) CSA protection data Gas group C Gas groups A, B Input voltage, max. Ui Internal inductance, max. LI General data Colour Isolating function Protection degree Segment UL 94 flammability rating Measurement - Monitoring - Setting V-0 Insulation coordination acc. to EN 50178 Pollution severity 2 III Creation date February 20, 2021 5:45:14 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 2 Data sheet VSSC6 TRLDMOV120VAC/DC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Rated data IEC / EN Capacitance Discharge current In (8/20s) wire-PE Max. continuous voltage, Uc (AC) Number of poles Protection level UP (typ.) Rated voltage (AC) Requirements category acc. to IEC 61643-21 Surge current-carrying capacity C1 Voltage type Discharge current Imax (8/20s) wire-PE Discharge current, max. (8/20 s) Max. continuous voltage, Uc (DC) Overload - failure mode Rated current IN Rated voltage (DC) Standards Surge current-carrying capacity C2 Volume resistance GOST-Zertifikat Screw connection 0.8 Nm 4 mm Tightening torque, min. 0.5 Nm Clamping range, min. 0.5 mm Wire cross-section, solid, min. 0.5 mm Conductor cross-section, flexible, AEH (DIN 46228-1), min. 0.5 mm Connection cross-section, stranded, min. 0.5 mm ETIM 7.0 ECLASS 9.1 ECLASS 11.0 283 pF 1.5 kA 150 V 1 < 600 V 120 V C1, C2 0.5 kA 8/20 s 1 kV 1.2/50 s AC/DC 6 kA 12 kA 212 V Mode 1 12 A 170 V IEC 61643-21 1.5 kA 8/20 s <0.1 Further details of approvals GOST certificate Connection data Type of connection Tightening torque, max. Clamping range, max. Wire cross-section, solid, max. Conductor cross-section, flexible, AEH (DIN 46228-1), max. Connection cross-section, stranded, max. 6 mm 4 mm 4 mm Classifications ETIM 6.0 ECLASS 9.0 ECLASS 10.0 EC000943 27-13-08-07 27-13-08-07 EC000943 27-13-08-07 27-13-08-07 Creation date February 20, 2021 5:45:14 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 3 Data sheet VSSC6 TRLDMOV120VAC/DC Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Tender specification sheets Long specification Feed-through terminal, 6.2mm wide with varistors between the two signal lines and the mounting rail potential, TS 35 contact base.Each signal path can be opened using an isolator. A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked. Short specification Feed-through terminal with varistors (MOV) between two signal lines and mounting rail potential. Each signal path can be opened using an isolator. TS 35 contact base. Version: 120 V UC Approvals Approvals ROHS UL File Number Search Conform E311081 Downloads Approval/Certificate/Document of Conformity Brochure/Catalogue Engineering Data Engineering Data User Documentation SIL Paper CE PAPER Declaration of Conformity CAT 4.4 ELECTR 16/17 EN STEP EPLAN, WSCAD Instruction sheet VSSC Creation date February 20, 2021 5:45:14 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 4 Data sheet VSSC6 TRLDMOV120VAC/DC Drawings Similar to illustration Weidmuller Interface GmbH & Co. KG Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Circuit diagram Creation date February 20, 2021 5:45:14 PM CET Catalogue status 12.02.2021 / We reserve the right to make technical changes. 5