CAP
-30°C
0°C
25°C
50°C
72°C
0.01 0.1 1
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
mA
Ah ACITY VS. CURRENT VOLTAGE VS. TEMPERATURE
3 mA
0.5 mA
100 µA
10 µA
2 mA
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
-50 -30 -10 10 30 50 70
ºC
Volts
DISCHARGE CHARACTERISTICS @ +25ºC
1.1 K
~3 mA
(0.7 Ah)
6.8 K
~0.5 mA
(0.98 Ah)
3.6 K
~1 mA
(1.0 Ah)
36 K
~0.1 mA
(0.9 Ah)
100 K
~36 µA
(0.82 Ah)
360 K
~10 µA
(0.72 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
LITHIUM XTRA
AVAILABLE TERMINATIONS
SUFFIX- /S STANDARD 15-5102-51020
SUFFIX- /T SOLDER TABS 15-5102-31500
SUFFIX- /P AXIAL PINS 15-5102-41500
SUFFIX- /PT2 RADIAL PINS 15-5102-36500
SUFFIX- /TP POLARIZED TABS 15-5102-52500
SUFFIX- /PT POLARIZED TABS 15-5102-53500
Nominal capacity @ 1 mA, to 2V 1.0 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 50 mA
Maximum pulse current capability 100 mA
Weight 9.2g (0.324 oz)
Volume 4.3 cc
Operating temperature range -55ºC to +85ºC
U.L. Component Recognition, MH 12193
MODEL TL-2150
International size reference: 1/2AA, ER14252
TECHNICAL DATA
(Typical values @+25ºC for batteries stored for one year or less)
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance. Rev. C 07/03