kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with “IEC
68-2-6”, test Fc (acceleration 10 G; below cross-over
frequency 57 to 62 Hz; amplitude 0.75 mm; frequency
range 10 to 2000 Hz, duration 90 minutes). Such a
vibration will not cause an open switch (no magnetic
field present) to close, nor a switch kept closed by an
80 AT coil to open.
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua1 (load 10 N).
Operating and Storage Temperature
Operating ambient temperature; min: -55°C; max:
+125°C. Storage temperature; min: -55°C; max:
+125°C. Note: Temperature excursions up to 150°C
may be permissible. For more information contact your
nearest Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10°C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20” test Ta, method 3:
solder globule temperature 235°C; ageing 1b:
4 hours steam.
Welding
The leads can be welded
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
* The Contact Resistance is measured using the Kelvin Method next to the glass body.
Model Number
RI-01CAA RI-01CA
Parameters Test Conditions Units
Operating Characteristics
Operate Range AT 7-19 16-25
Release Range AT 3-16 4-18
Operate Time - including bounce (typ.) (energization) ms 0.30 (24 AT) 0.35 (31 AT)
Bounce Time (typ.) (energization) ms 0.10 (24 AT) 0.10 (31 AT)
Release Time (max) (energization)
µ
s50 (24 AT) 50 (31 AT)
Resonant Frequency (typ.) Hz 9000 9000
Electrical Characteristics
Switched Power (max) W 10 10
Switched Voltage DC (max) V 180 200
Switched Voltage AC, RMS value (max) V 130 140
Switched Current DC (max) mA 250 500
Switched Current AC, RMS value (max) mA 250 500
Carry Current DC (max) A 1 1
Breakdown Voltage (min) V 200 250
Contact Resistance* (initial max) (energization) m
Ω
100 (20 AT) 100 (25 AT)
Contact Resistance* (initial typ.) (energization) m
Ω
90 (20 AT) 90 (25 AT)
Contact Capacitance (max) without test coil pF 0.30 .25
Insulation Resistance (min) RH
≤
45% M
Ω
10
6
10
6