Molded case circuit breakers Index M cir old cu ed it br cas ea e ke rs 17 - Molded case circuit breakers Formula MCCBs.......................................................17.1 - 17.10 Tmax UL489B Photovoltaic circuit breakers.........17.67 - 17.70 General information Introduction.......................................................................................................................17.1 Circuit breakers for power distribution...............................................................................17.2 Catalog number explanation..............................................................................................17.3 General information Introduction.....................................................................................................................17.67 Catalog number explanation............................................................................................17.68 Ordering details A1, 100A...........................................................................................................................17.4 A2, 250A, 600Y/347V, 480V ..........................................................................................17.5 Ordering details Tmax UL489B MCCBs and switches..............................................................................17.69 Jumper kit accessories...................................................................................................17.70 Accessories......................................................................................................................17.6 -17.9 Accessories, T1 - T7...............................................17.71 - 17.83 Tmax MCCBs..........................................................17.11 - 17.10 Approximate dimensions, T1 - T7........................17.84 - 17.101 General information Introduction.....................................................................................................................17.11 Ordering details guide.........................................................................................17.12 - 17.13 Catalog number explanation............................................................................................17.14 Ordering details T1, 100A, 600Y/347V, 480V ............................................................................17.15 - 17.16 T2, 100A, 480V ...............................................................................................17.17 - 17.19 T3, 225A, 600Y/347V, 480V ............................................................................17.20 - 17.22 Ts3, 150A, 600V , 225A, 480V ......................................................................17.23 - 17.26 T4, 250A, 600V ...............................................................................................17.27 - 17.32 T5, 400/600A, 600V ........................................................................................17.33 - 17.37 T6, 600A, 800A, 600V .....................................................................................17.38 - 17.40 T7 (Toggle), 1000A, 1200A, 600V ................................................................................17.41 T7, 1000A, 1200A, 600V .................................................................................17.42 - 17.44 T7M (Stored energy)............................................................................................17.45 - 17.55 T8, 1600/2000/2500/3000A, 600VAC .............................................................17.56 - 17.66 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.A 1SXU000023C0202 Rev. A se ca kers ed ea old t br M ui c cir Notes 17 17.B 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Molded case circuit breakers FORMULA Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage FORMULA Molded case circuit breakers FO R M MU CC L Bs A Introduction ABB's FORMULA molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available. The A1 breaker frame size ranges in amperes from 15 through 100 and the A2 breaker frame size ranges from 125 through 250 amperes. All UL FORMULA circuit breakers offer protection trip units that have fixed thermal and magnetic threshold values and are standard as a fixed version with front terminals. Standards UL 489 & IEC 60947-2 Dimensions (W x D x H): 1 pole: 1.00 x 2.36 x 5.12 2 pole: 2.00 x 2.36 x 5.12 3 pole: 3.00 x 2.36 x 5.12 Weight: 1 pole: 0.54 lbs 2 pole: 1.04 lbs 3 pole: 1.54 lbs 17 Available accessories: Shunt opening release (2p & 3p) Undervoltage release (2p & 3p) Auxiliary contacts (2p & 3p) Termination kits (1p, 2p & 3p) Padlocks (1p, 2p & 3p) Direct and extended rotary handles (3p) 17.1 1SXU000023C0202 Rev. A A UL M R Bs FO CC M Circuit breakers for power distribution Technical data A1 Frame size Rated current, In Poles [Nr] Rated service voltage, Ue (AC) 50-60 Hz (DC) Versions Performance Level Poles Rated ultimate short circuit breaking capacity, Icu Interrupting rating @ 240 V 50-60 Hz (AC) Interrupting rating @ 125 V (DC) 1 pole (in 2012) Interrupting rating @ 250 V (DC) 2 poles in series (2p, 3p) (in 2012) Reference Standard Isolation behavior Fixing onto DIN rail Dimensions (Width x Depth x Height) 1 pole 2 poles 3 poles Weight 1 pole 2 poles 3 poles Trip Unit - Thermomagnetic TMF A A Nr V V A2 Nr 100 15...100 1, 2, 3 240 (1p, 2p, 3p) 125 (1p), 250 (2p,3p) Fixed A N 1 2, 3 1 2, 3 250 125...250 1, 2, 3 240 (1p, 2p, 3p) 125 (1p), 250 (2p,3p) Fixed A N 1 2, 3 1 2, 3 kA kA kA 10 5 - 10 5 - 10 18 10 5 UL 489 Yes DIN EN 50022 25 10 10 14 10 10 UL 489 Yes DIN EN 50022 in in in 1.00 x 2.36 x 5.12 2.00 x 2.36 x 5.12 3.00 x 2.36 x 5.12 1.38 x 2.36 x 5.91 2.76 x 2.36 x 5.91 4.13 x 2.36 x 5.91 lbs lbs lbs 0.54 1.04 1.54 Yes 0.82 1.61 2.43 Yes 25 25 17 17.2 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Circuit breakers for power distribution Catalog number explanation A W FO R M MU CC L Bs A Number of Poles -1= 1 pole (UL&IEC) -2= 2 pole (UL&IEC) None= 3 pole (UL&IEC) -4= 4 pole (IEC) Type Connectors W=none Trip Unit Function T=thermalmagnetic (UL&IEC) A=ELT - LI (IEC) Current Rating 015=15A (UL&IEC); 016=16A (IEC) 020=20A (UL&IEC); 025=25A (UL&IEC) 030=30A (UL&IEC); 032=32A (IEC) 040=40A (UL&IEC); 050=50A (UL&IEC) 060=60A (UL&IEC); 063=63A (IEC) 070=70A (UL&IEC); 080=80A (UL&IEC) 090=90A (UL&IEC); 100=100A (UL&IEC) 125=125A (UL&IEC); 150=150A (UL&IEC) 160=160A (UL&IEC); 175=175A (UL&IEC) 200=200A (UL&IEC); 225=225A (UL&IEC) 250=250A (UL&IEC); 320=320A (IEC) 400=400A (IEC); 500=500A (IEC); 630=630A (IEC) Interrupting Rating Class A=adequate(UL&IEC); B=basic(IEC); C=common(IEC) N=normal(UL&IEC); S=standard(IEC) Frame Size: 1=100A, UL; 2=250A, UL A=125A, IEC; B=250A, IEC; C=400A, IEC; D=630A, IEC 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.3 1SXU000023C0202 Rev. A A UL M R Bs FO CC M A1 100A 1 Pole 2 Pole 3 Pole A1 - 100A Frame TMF, thermal magnetic fixed - fixed mount (F), front terminals (F) Breaker A1A A1N IC at 240VAC 10kA 1 pole 18kA 2-3 pole 25kA Rating (A) Magnetic trip 1 pole catalog number 2 pole catalog number 3 pole catalog number 15 400 A1A015TW-1 A1A015TW-2 A1A015TW 20 400 A1A020TW-1 A1A020TW-2 A1A020TW 25 400 A1A025TW-1 A1A025TW-2 A1A025TW 30 400 A1A030TW-1 A1A030TW-2 A1A030TW 40 400 A1A040TW-1 A1A040TW-2 A1A040TW 50 500 A1A050TW-1 A1A050TW-2 A1A050TW 60 600 A1A060TW-1 A1A060TW-2 A1A060TW 70 700 A1A070TW-1 A1A070TW-2 A1A070TW 80 800 A1A080TW-1 A1A080TW-2 A1A080TW 90 900 A1A090TW-1 A1A090TW-2 A1A090TW 100 1000 A1A100TW-1 A1A100TW-2 A1A100TW 15 400 A1N015TW-1 A1N015TW-2 A1A015TW 20 400 A1N020TW-1 A1N020TW-2 A1A020TW 25 400 A1N025TW-1 A1N025TW-2 A1A025TW 30 400 A1N030TW-1 A1N030TW-2 A1A030TW 40 400 A1N040TW-1 A1N040TW-2 A1A040TW 50 500 A1N050TW-1 A1N050TW-2 A1A050TW 60 600 A1N060TW-1 A1N060TW-2 A1A060TW 70 700 A1N070TW-1 A1N070TW-2 A1A070TW 80 800 A1N080TW-1 A1N080TW-2 A1A080TW 90 900 A1N090TW-1 A1N090TW-2 A1A090TW 100 1000 A1N100TW-1 A1N100TW-2 A1A100TW 17 17.4 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage FO R M MU CC L Bs A A2 250A, 600Y/347V, 480V Thermal-magnetic 1 Pole 2 Pole 3 Pole A2 - 250A Frame TMF, thermal magnetic fixed - fixed mount (F), front terminals (F) Breaker IC at 240VAC A2A A1N 10kA 1 pole 18kA 2-3 pole 25kA Rating (A) Magnetic trip 1 pole catalog number 2 pole catalog number 3 pole catalog number 125 1250 A2A125TW-1 A2A125TW-2 A2A125TW 150 1500 A2A150TW-1 A2A150TW-2 A2A150TW 175 1750 A2A175TW-1 A2A175TW-2 A2A175TW 200 2000 A2A200TW-1 A2A200TW-2 A2A200TW 225 2250 A2A225TW-1 A2A225TW-2 A2A225TW 250 2500 A2A250TW-1 A2A250TW-2 A2A250TW 125 1250 A2N125TW-1 A2N125TW-2 A2N125TW 150 1500 A2N150TW-1 A2N150TW-2 A2N150TW 175 1750 A2N175TW-1 A2N175TW-2 A2N175TW 200 2000 A2N200TW-1 A2N200TW-2 A2N200TW 225 2250 A2N225TW-1 A2N225TW-2 A2N225TW 250 2500 A2N250TW-1 A2N250TW-2 A2N250TW 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.5 1SXU000023C0202 Rev. A A UL M R Bs FO CC M Accessories Electrical A1 - A2 Shunt opening release (SOR) Frame size Voltage Catalog number 12VDC 24-30VAC/DC 48-60VAC/DC A1 - A2 110-127VAC 220-240VAC The shunt opening release allows for opening of the circuit breaker by means of a non-permanent electrical control. Operation of the release is guaranteed for a voltage between 70% and 110% of the power supply rated voltage value. KA2S9 KA2S8 KA2S7 KA2S4 KA2S2 Cabled service release SOR-C and UVR-C Undervoltage release (UVR) Frame size Voltage Catalog number 24-30VAC/DC KA2U8 48VAC/DC KA2U7 60VAC/DC KA2U5 A1 - A2 110-127VAC KA2U4 220-240VAC KA2U2 The undervoltage release ensures opening of the circuit breaker for lack/lowering of the release power supply voltage. Operation of the release is guaranteed for a voltage between 70% and 35% of the power supply rated voltage value. After tripping, the circuit breaker can be closed again starting from a voltage higher than 85% of the power supply rated voltage value. Auxiliary contacts (AUX) & early auxiliary contacts (AUE) Frame size Description 2 Pole Catalog number 3 Pole Catalog number AUX-C 1Q+1SY 250 VAC/DC KA2AS-2 KA2AS AUX-C 2Q+1SY 250 VAC/DC KA2AS2-2 KA2AS2 AUX-C 1Q+1SY 24 VDC KA2ASAU-2 KA2ASAU A1 - A2 AUX-C 2Q+1SY 24 VDC KA2AS2AU-2 KA2AS2AU AUX-C 250V 1 CONT. SPARE PART* KA2ASSP KA2ASSP AUE 2 CONTACTS x RHx - KA2RH-EM The auxiliary contacts allow information about the state of the circuit breaker to be available through an electronic signal to another apparatus. The early auxiliary contacts are normally open contacts which allow the undervoltage release to be supplied in advance prior to the closing of the main contacts in direct and extended rotary handle operating mechanisms. 17 1 Electrical/mechanical accessories cannot be installed on single pole breakers. 2 Rated 480Y/277 VAC for 15A. 3 When protected by a OCPD with appropriate ratings. 17.6 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage FO R M MU CC L Bs A Accessories Mechanical A1 - A2 Terminal FCCuAl Terminal FCCuAl with cable Front terminals for copper aluminum cables - FCCuAL Description 1 piece catalog number 2 piece catalog number 3 piece catalog number 4 piece catalog number 6 piece catalog number KIT FC CuAl A1 80A KIT FC CuAl A1 100A KIT FC CuAl A2 225A* KIT FC CuAl A2 250A KA1080-1 KA1100-1 KA2225-1 KA2250-1 KA1080-2 KA1100-2 KA2225-2 KA2250-2 KA1080-3 KA1100-3 KA2225-3 KA2250-3 KA1080-4 KA1100-4 KA2225-4 KA2250-4 KA1080-6 KA1100-6 KA2225-6 KA2250-6 Frame size A1 A2 * 250A Cu cables and 225A Al cables Terminal F Terminal F with cable lug Terminal F with busbar Front terminals - F Frame size Description 1 piece catalog number 2 piece catalog number 3 piece catalog number 4 piece catalog number 6 piece catalog number A1 A2 KIT F A1 KIT F A2 KA1F-1 KA2F-1 KA1F-2 KA2F-2 KA1F-3 KA2F-3 KA1F-4 KA2F-4 KA1F-6 KA2F-6 Front terminals are supplied as standard with all FORMULA circuit breakers. 17 Terminal EF Terminal EF with busbar Front extended terminals - EF (IEC only) Frame size Description 1 piece catalog number 2 piece catalog number 3 piece catalog number 4 piece catalog number 6 piece catalog number A1 A2 KIT EF A1 KIT EF A2 KA1EF-1 KA2EF-1 KA1EF-2 KA2EF-2 KA1EF-3 KA2EF-3 KA1EF-4 KA2EF-4 KA1EF-6 KA2EF-6 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.7 1SXU000023C0202 Rev. A A UL M R Bs FO CC M Accessories Mechanical A1 - A2 Terminal ES Terminal ES with cable lug Terminal ES with busbar Front extended spread terminals - ES (IEC only) Frame size Description 1 piece catalog number 2 piece catalog number 3 piece catalog number 4 piece catalog number 6 piece catalog number A1 A2 KIT ES A1 KIT ES A2 - - KA1ES-2 KA2ES-2 KA1ES-3 KA2ES-3 KA1ES-4 KA2ES-4 KA1ES-6 KA2ES-6 Terminal covers - low profile (LTC) and high profile (HTC) Frame size A1 A2 High terminal cover (HTC) A1 - A2 Catalog number Description KA1LTC-3 KA1HTC-3 KA2LTC-3 LTC 3p - 2pcs HTC 3p - 2pcs LTC 3p - 2pcs HTC 3p - 2pcs Sealable screws for terminal covers* Sealable screws for front* KA2HTC-3 KA2SSW-T KA2SSW-F * IEC rated only Low terminal cover (LTC) Phase barriers - low profile and high profile 17 Frame size Description A1 A2 A1 - A2 PB 50mm PB 80mm PB 100mm 2-Piece catalog number 4-Piece catalog number KA1PBL-2 KA2PBL-2 KA1PBL-3 KA2PBL-3 KA2PBH-2 KA2PBH-3 Phase barriers Direct mount rotary handle (RHD) Frame size Description Catalog number A1 - A2 RHD A1-A2 STANDARD DIRECT RHD A1-A2 EMERGENCY DIRECT KA2RHD KA2RHDEM Direct handle (RHD) 17.8 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage FO R M MU CC L Bs A Accessories Mechanical A1 - A2 Extended mount rotary handle (RHE) Frame size Description A1 - A2 RHE KIT A1-A2 STANDARD EXTENDED RHE KIT A1-A2 EMERGENCY EXTENDED RHE A1-A2 BASE RHE A1-A2 SHAFT RHE A1-A2 STANDARD HANDLE RHE A1-A2 EMERGENCY HANDLE Extended handle (RHE) Catalog number KA2RHE KA2RHEEM KA2RHE-B KA2RHE-S KA2RHE-H KA2RHE-HEM Padlocks for lever operating mechanism (PLL) Frame size A1 - A2 Description PLL - removable in open position (1p, 2p, 3p) PLL - fixed in open position (3p) PLL - fixed in open and closed position (3p) Catalog number KA2LDOR KA2LDOR KA2LD Fixed padlock in open position (PLL) Fixed padlock in open and closed position (PLL) Removable padlock in open position (PLL) Key lock on handle and front lever operating mechanism (RHL) (IEC only) Frame size Description A1 - A2 RHL-D open position, different keys RHL-S open position, type A key RHL-S open position, type B key RHL-S open position, type C key RHL-S open position, type D key RHL-D open and closed position, different keys Key lock for direct handle 17 Catalog number KA2RHLO KA2RHLO-A KA2RHLO-B KA2RHLO-C KA2RHLO-D KA2RHL Bracket for fixing on DIN rail (IEC only) Frame size Description A1 - A2 Bracket for 1p, 2p, 3p Catalog number KA2DIN Bracket for DIN rail Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.9 1SXU000023C0202 Rev. A A UL M R Bs FO CC M Notes 17 17.10 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Molded case circuit breakers Tmax Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high performance, versatility and standardization in a range of molded case circuit breakers. The ABB Tmax line of circuit breakers, with a range up to 3000A, has several key features that go along with its very small size: *Double insulation - this construction characteristic allows for the UL Listed field installation of internal accessories without exposure to energized parts. *Complete range of electrical and mechanical accessories *Positive operation - breakers from ABB ensure that the toggle indicates the precise position of the moving contacts. This guarantees safe and reliable signaling by the device. *Installation - Tmax molded case circuit breakers can be installed in panels and switchboards in either the horizontal or vertical planes while being fed from either end without any derating of their performance characteristics. *Interrupting ratings at 480VAC up to 150kAIC. *Compact size *All Tmax molded case circuit breakers are UL Listed and IEC rated for global application and acceptance. *All versions of the Tmax family are suitable for reverse feed applications. The ABB Tmax product line has the performance and accessories to satisfy all industry requirements in the 600VAC to 600VDC ranges. Frame sizes -- Nine basic sizes The ABB Tmax series includes nine basic frame sizes as well as the T1 single pole with the range rated from 15A to 3000A at 480VAC. The various versions carry the following interrupting capacities: * B Basic breaking capacity * N Normal breaking capacity * S Standard breaking capacity * H High breaking capacity * L Extra high breaking capacity * V Very high breaking capacity Derived versions * * * * * Thermal magnetic Electronic Molded case switches Motor circuit protectors (MCPs) Direct current (DC) rated 17 ABB Tmax versions * Fixed: all models * Drawout or plug-in: T2, T3, Ts3, T4, T5, T6, T7 & T7M * UL File #E93565 (breakers and MCPs) #E116596 (Accessories) #E116595 (Molded case switches) 17.11 1SXU000023C0202 Rev. A ax Tm CBs C M Selection Guide Circuit breakers for power distribution T1 - Ts3 T1 1P T1 Type T3 Ts3 Tmax T1 1p Tmax T1 Tmax T2 Tmax T3 Tmax Ts3 [A] 100 100 100 225 150 225 [Nr] 1 3-4 3-4 3-4 2-3-4 2-3-4 AC (50-60Hz) [V] 347 600Y/347 480 600Y/347 600 480 DC [V] 500 600 Frame size Number of poles Rated voltage T2 Interrupting ratings 500 B Tmax Ts3 500 N S H N S N H L N H L 50 2 65 150 50 65 65 100 150 65 100 150 35 65 25 50 85 5 25 50 65 14 14 25 20 35 50 240V AC [kA rms] 277V AC [kA rms] 18 1 347V AC [kA rms] 14 1 480V AC [kA rms] 22 2 25 35 600Y/347V AC [kA rms] 10 10 10 600V AC [kA rms] 250V DC (2 poles in series) [kA rms] 25 25 35 25 25 35 500V DC (3 poles in series) [kA rms] 500V DC (2 poles in series) [kA rms] 35 50 65 600V DC (3 poles in series) [kA rms] 20 35 50 Trip units TMF TMD/TMA Dimensions ELT MA Electronic H [in/mm] 5.12/130 5.12/130 5.12/130 5.9/150 6.7/170 6.7/170 W 3p [in/mm] 1/25.4 3/76 3.54/90 4.13/105 4.13/105 4.13/105 [in/mm] 2.76/70 2.76/70 2.76/70 2.76/70 4.07/103.5 4.07/103.5 25000 25000 25000 25000 25000 25000 D Mechanical life [No. operations] 17 1 2 3 4 5 In15A = 10kA@277VAC 10kA@347VAC In15A = 35kA@240VAC 14kA@480Y/277 VAC T5 600 with electronic trip units only and in three pole version 2p breakers: available only in N interrupting rating In from 15A up to 30A=65kA@480V AC 17.12 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Selection Guide Circuit breakers for power distribution T4 - T8 T4 T5 T6 Type Frame size Number of poles Rated voltage T7 T8 Tmax T4 Tmax T5 Tmax T6 Tmax T7/T7M Tmax T8 [A] 250 400-600 3 800 1000-1200 1600, 2000, 2500 & 3000 [Nr] 2-3-4 4 2-3-4 4 3-4 3-4 3-4 AC (50-60Hz) [V] 600 600 600 600 600 DC [V] Interrupting ratings 600 N S 600 H L V N S 600 H L V N S H L 240V AC [kA rms] 65 100 150 200 200 65 100 150 200 200 65 100 200 200 277V AC [kA rms] 347V AC [kA rms] 480V AC [kA rms] 25 600Y/347V AC [kA rms] 600V AC [kA rms] 18 250V DC (2 poles in series) [kA rms] 500V DC (3 poles in series) [kA rms] H L V 100 150 125 35 65 100 150 25 35 65 100 150 35 50 65 100 50 65 100 125 25 35 25 35 25 35 25 50 65 100 65 100 18 65 100 20 42 500V DC (2 poles in series) [kA rms] 25 35 50 65 100 25 35 50 65 100 35 35 50 65 600V DC (3 poles in series) [kA rms] 16 25 35 50 25 35 50 20 35 50 Trip units S 65 TMF TMD/TMA 65 16 65 20 ELT MA Electronic Dimensions H [in/mm] 8.07/205 8.07/205 10.55/268 10.55/268 15 / 382 W 3p [in/mm] 4.13/105 5.51/140 8.26/210 8.26/210 16.8 / 427 D [in/mm] 4.07/103.5 4.07/103.5 4.07/103.5 6.06/154 (toggle) 7/178 (motor) 11.2 / 282 20,000 20,000 20,000 10,000 15,000 Mechanical life [No. operations] 17 1 2 3 4 5 6 In15A = 10kA@277 VAC 10kA@347 VAC In15A = 35kA@240 VAC 14kA@480Y/277 VAC T5 600 with electronic trip units only and in three pole version2p T4N250 and T5N400 available only in N interrupting capacity. In from 15A up to 30A=65kA@480 VAC Applies to MCS only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.13 1SXU000023C0202 Rev. A ax Tm CBs C M General information Catalog number explanation T3 S 080 T W - 4 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch S_ = Shunt trip with voltage code U_ = Undervoltage release with voltage code Number of poles -1 =1 pole (T1 only) -2 = 2 pole -4 = 4 pole None = 3 pole Type connectors W = None L = Lugs included Trip unit function B = LS/I (AC only) D = Molded Case Switch (MCS) T = Thermal-magnetic M=Magnetic only (MCP) E5 = Electronic MCP (AC only) C = LSI (AC only) E = LSIG (AC only) CZ = LSI/PD 2 EZ = LSIG/PD 2 P = LI - LCD Display 3 R = LSI - LCD Display 3 S = LSIG - LCD Display 3 Current rating 015 = 15A 080 = 80A 100 = 100A 225 = 225A 250 = 250A 400 = 400A 600 = 600A 800 = 800A 1200 = 1200A Interrupting rating class B = Basic N = Normal S = Standard H = High L = Extra High V = Very high Q = 100% Rated 17 Frame size T1 T2 T3 Ts3 T4 T5 T6 T7 = 100A = 100A = 225A = 225A = 250A = 400A, 600A = 600A, 800A = 1000A, 1200A (toggle) 1 Consult ABB for factory installed accessories. 2 Trip unit with communication module. 3 Available on T7 toggle version only. 17.14 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T1 100A, 600Y/347V, 480V Thermal-magnetic Dimensions 3P Fixed Version 5.12H x 3.00W x 2.76D Weight 2.34 (Ibs) T1 General The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Standards The UL489/CSA 22.2 version of T1 also carries an IEC-60947-2 rating. Versions UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating B (1 pole) N 240VAC 15 - 100A -- 347VAC 15A 20 - 100A 10 14 -- -- 50 1 -- -- 14 22 -- -- -- 10 25 25 480VAC 600Y/347VAC 250VDC 2 pole series 500VDC 3 pole series 15A 2 20 - 100A 15 - 100A 15 - 100A 15 - 100A The T1 frame is available in two versions: T = Thermal-magnetic, fixed D = Molded case switch Performance levels The T1 breaker has two performance levels available: B = Basic single pole N = Normal three pole Number of poles The T1 molded case circuit breaker is available in single, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. IEC 60947-2 Interrupting capacity (kA RMS) Voltage Continuous rating B (1 pole) N 230VAC 15 - 100A 50 415VAC 690VAC 500VDC 3 pole series 15 - 100A 15 - 100A 15 - 100A 25 3 -- -- -- 36 6 36 Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 17 1 In 15A 35kA @ 240VAC. 2 15A available in 480Y/277 VAC only. 3 Interrupting capacity for 16-20A is 16kA Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.15 1SXU000023C0202 Rev. A ax Tm CBs C M T1 100A, 600Y/347V, 480V Thermal-magnetic/Molded Case Switch T1B TMF -- Single pole thermal magnetic fixed 1 Breaker T1B IC at 277VAC Rating (A) Magnetic trip (A) 1 pole, 277VAC catalog number 10kA 15 20 25 30 40 50 60 70 80 90 100 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 T1B015TL-1 T1B020TL-1 T1B025TL-1 T1B030TL-1 T1B040TL-1 T1B050TL-1 T1B060TL-1 T1B070TL-1 T1B080TL-1 T1B090TL-1 T1B100TL-1 18kA T1N TMF -- 3 pole thermal magnetic fixed Breaker T1N IC at 480VAC Rating (A) Magnetic trip (A) 14kA 15 20 25 30 40 50 60 70 80 90 100 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 22kA 3 pole, 600Y/347VAC/500VDC catalog number T1N015TL 2 T1N020TL T1N025TL T1N030TL T1N040TL T1N050TL T1N060TL T1N070TL T1N080TL T1N090TL T1N100TL T1N TMF -- 100% Rated thermal-magnetic Breaker IC at 480VAC 14kA 17 T1N 22kA Rating (A) 15 1 20 25 30 40 50 60 70 80 90 100 Magnetic trip (A) 100 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 3 pole, 600Y/347VAC/500VDC catalog number T1NQ015TL T1NQ020TL T1NQ025TL T1NQ030TL T1NQ040TL T1NQ050TL T1NQ060TL T1NQ070TL T1NQ080TL T1NQ090TL T1NQ100TL T1N-D -- Molded case switch Breaker T1-D Interrupting capacity 3 240V, 50kA Rating (A) 100 Magnetic trip (A) 480VAC/500VDC catalog number 1000 T1N100DL 1 Electrical/mechanical accessories cannot be installed on single pole breakers. 2 Rated 480Y/277 VAC for 15A. 3 When protected by a OCPD with appropriate ratings. 17.16 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T2 100A, 480V Thermal-magnetic/electronic/current limiting Dimensions 3P Fixed Version 5.12H x 3.54W x 2.76D Weight 2.84 (Ibs) T2 General The T2 breaker family ranges from 15 through 100 amperes. The T2 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection as well as a version with microprocessor-based electronic trip unit. Thermal overload protection is provided by heat sensitive bimetals. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Standards The UL489/CSA 22.2 version of T2 also carries an IEC-60947-2 rating. Versions The T2 frame is available in four versions: T = Thermal-magnetic, fixed B = Adjustable LS/I electronic M = Magnetic only (MCP) E5 = Electronic instantaneous only (MCP) UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating S H 240VAC 15 - 100A 65 150 480VAC 15 - 100A 35 65 IEC 60947-2 Interrupting capacity (kA RMS) Voltage Continuous rating S H 230VAC 415VAC 690VAC 15 - 100A 15 - 100A 15 - 100A 85 50 7 100 70 8 500VDC 3 pole series 15 - 100A 50 70 Trip functions These tripping functions are available: L = Long time S = Short time I - Instantaneous Performance levels The T2 breaker has two performance levels available: S = Standard H = High - UL Current Limiting Number of poles 17 The T2 is available in three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.17 1SXU000023C0202 Rev. A ax Tm CBs C M T2 100A, 480V Thermal-magnetic/current limiting T2 -- 100A TMF thermal magnetic fixed Breaker T2S T2H UL current limiting IC at 480VAC 35kA 65kA T2 - 100A TMF, 100% rated thermal magnetic fixed Rating (A) Magnetic trip (A) 3 pole, 480VAC Catalog number 15 20 25 30 40 50 60 70 80 90 100 15 20 25 30 40 50 60 70 80 90 100 500 500 500 500 500 500 600 700 800 900 1000 500 500 500 500 500 500 600 700 800 900 1000 T2S015TW T2S020TW T2S025TW T2S030TW T2S040TW T2S050TW T2S060TW T2S070TW T2S080TW T2S090TW T2S100TW T2H015TW T2H020TW T2H025TW T2H030TW T2H040TW T2H050TW T2H060TW T2H070TW T2H080TW T2H090TW T2H100TW Breaker T2S T2H UL current limiting IC at 480VAC 35kA 65kA Rating (A) Magnetic trip (A) 15 20 25 30 40 50 60 70 80 90 100 15 20 25 30 40 50 60 70 80 90 100 500 500 500 500 500 500 600 700 800 900 1000 500 500 500 500 500 500 600 700 800 900 1000 3 pole, 480VAC Catalog number T2SQ015TW T2SQ020TW T2SQ025TW T2SQ030TW T2SQ040TW T2SQ050TW T2SQ060TW T2SQ070TW T2SQ080TW T2SQ090TW T2SQ100TW T2HQ015TW T2HQ020TW T2HQ025TW T2HQ030TW T2HQ040TW T2HQ050TW T2HQ060TW T2HQ070TW T2HQ080TW T2HQ090TW T2HQ100TW 17 17.18 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T2 100A, 480V , 100% rated Electronic/Current limiting/MCP T2 -- 100A Frame, electronic trip unit (AC only) Breaker IC at 480VAC Trip unit type T2S 35kA PR221DS-LS/I T2H UL Current Limiting 65kA PR221DS-LS/I CT rating 3 pole, 480VAC catalog number 25A 60A 100A 25A 60A 100A T2S025BW T2S060BW T2S100BW T2H025BW T2H060BW T2H100BW T2 - 100A Frame 100% rated, electronic trip unit (AC only) Breaker IC at 480VAC Trip unit type T2S 35kA PR221DS-LS/I T2H UL Current Limiting 65kA PR221DS-LS/I CT rating 3 pole, 480VAC catalog number 25A 60A 100A 25A 60A 100A T2SQ025BW T2SQ060BW T2SQ100BW T2HQ025BW T2HQ060BW T2HQ100BW Rating Adjustment range 3 pole, 480VAC Catalog number 20A 50A 100A 20A 50A 100A 120 - 240 300 - 600 600 - 1200 120 - 240 300 - 600 600 - 1200 T2S020MW T2S050MW T2S100MW T2H020MW T2H050MW T2H100MW T2 -- 100A Frame, instantaneous only (MCP) Breaker IC at 480VAC Trip unit type T2S 35kA Mag only T2H 65kA Mag only T2 -- 100A Frame, instantaneous only, electronic (MCP - AC only) Breaker IC at 480VAC Trip unit type T2S 35kA Instantaneous only T2H 65kA Instantaneous only Rating Adjustment range 3 pole, 480VAC Catalog number 25A 60A 100A 25A 60A 100A 25 - 250 60 - 600 100 - 1000 25 - 250 60 - 600 100 - 1000 T2S025E5W T2S060E5W T2S100E5W T2H025E5W T2H060E5W T2H100E5W 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.19 1SXU000023C0202 Rev. A ax Tm CBs C M T3 225A, 600Y/347V, 480V Thermal-magnetic Dimensions 3P Fixed Version 5.9H x 4.13W x 2.76D Weight 5.45 (Ibs) T3 General The T3 breaker family ranges from 60 through 225 amperes. The T3 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection begins at 10 times the thermal rating of the breaker using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits. Standards The UL489/CSA 22.2 version of T3 also carries an IEC-60947-2 rating. Versions The T3 frame is available in three versions: T = Thermal-magnetic, fixed M = Magnetic only (MCP) D = Molded case switch Performance levels The T3 breaker has two performance levels available: N = Normal S = Standard UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage Continuous rating N S 240VAC 60 - 225A 50 65 480VAC 60 - 225A 25 35 600Y/347VAC 60 - 225A 10 10 250VDC 2 pole series 60 - 225A 25 35 500VDC 3 pole series 60 - 225A 25 35 IEC 60947-2 Interrupting capacity (kA RMS) Voltage Continuous rating N S 230VAC 60 - 225A 50 85 50 415VAC 60 - 225A 36 690VAC 60 - 225A 5 8 750VDC 3 pole series 60 - 225A 36 50 Number of poles The T3 molded case circuit breaker is available in three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 17 17.20 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T3 225A, 600Y/347V, 480V Thermal-magnetic T3 - 225A Frame TMF, 100% rated thermal magnetic fixed T3 -- 225A Frame TMF, thermal magnetic fixed Breaker IC at 480VAC T3N 25kA T3S 35kA Rating (A) Magnetic trip (A) 3 pole, 480VAC/500VDC Catalog number 60 70 80 90 100 125 150 175 200 225 60 70 80 90 100 125 150 175 200 225 600 700 800 900 1000 1250 1500 1750 2000 2250 600 700 800 900 1000 1250 1500 1750 2000 2250 T3N060TW T3N070TW T3N080TW T3N090TW T3N100TW T3N125TW T3N150TW T3N175TW T3N200TW T3N225TW T3S060TW T3S070TW T3S080TW T3S090TW T3S100TW T3S125TW T3S150TW T3S175TW T3S200TW T3S225TW Breaker IC at 480VAC T3N 25kA T3S 35kA Rating (A) Magnetic trip (A) 3 pole, 600/347V VAC/500VDC Catalog number 60 70 80 90 100 125 150 175 200 225 60 70 80 90 100 125 150 175 200 225 600 700 800 900 1000 1250 1500 1750 2000 2250 600 700 800 900 1000 1250 1500 1750 2000 2250 T3NQ060TW T3NQ070TW T3NQ080TW T3NQ090TW T3NQ100TW T3NQ125TW T3NQ150TW T3NQ175TW T3NQ200TW T3NQ225TW T3SQ060TW T3SQ070TW T3SQ080TW T3SQ090TW T3SQ100TW T3SQ125TW T3SQ150TW T3SQ175TW T3SQ200TW T3SQ225TW 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.21 1SXU000023C0202 Rev. A ax Tm CBs C M T3 225A, 600Y/347V, 480V MCP/Molded case switch T3 -- 225A Frame instantaneous only, (MCP) Breaker IC at 488-VAC Trip unit type T3S 35kA Mag only Rating Adjustment range 3 pole, 480VAC Catalog number 100A 125A 150A 200A 600 - 1200 750 - 1500 900 - 1800 1200 - 2400 T3S100MW T3S125MW T3S150MW T3S200MW T3S-D -- Molded case switch Breaker Interrupting capacity 1 Rating (A) Magnetic trip (A) 3 pole, 480VAC/500VDC Catalog number T3S-D 240V, 65kA 480V, 35kA 150 225 1500 2250 T3S150DW T3S225DW 17 1 When protected by a OCPD with appropriate ratings. 17.22 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Ts3 150A, 600V , 225A, 480V Thermal magnetic Dimensions 3P Fixed Version 6.7H x 4.13W x 4.07D Weight 6.75 (Ibs) Ts3 General The Ts3 breaker family ranges from 15 through 225 amperes. The Ts3 trip mechanisms are non-interchangeable and use sensitive electromagnetic relays for overcurrent trip protection. Heat sensitive bimetals are used for thermal overcurrent protection. Short circuit current protection begins at 10 times the thermal rating of the breaker and uses a magnetic coil principle. Standards The UL489/CSA 22.2 version of Ts3 also carries an IEC-60947-2 rating. Versions To meet all application needs, the Ts3 is available in various versions: T =Thermal-magnetic D = Molded case switch M = Magnetic only (MCP) Performance level Each version is also available in different maximum fault interrupting levels N = Normal H = High L = Extra high Number of poles The Ts3 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. UL/CSA Interrupting capacity (kA RMS) UL489 / CSA C22.2 Voltage 150AF, 15A-150A 240 VAC 480 VAC 600 VAC 500 VDC 600 VDC 225AF, 175A-225A 240 VAC 480 VAC 600 VAC 500 VDC 600 VDC N H L 65 25 14 35 20 100 50 14 50 35 85 25 65 50 65 25 - 20 - 100 50 - 35 - 150 65 - 50 - 100 65 18 35 170 85 20 50 150 1 IEC-60947-2 Interrupting capacity (kA RMS) 230 VAC 415 VAC 690 VAC 750 VDC 2 65 35 14 20 Molded case switches UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection. 17 1 15-30A are 65kA at 480VAC Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.23 1SXU000023C0202 Rev. A ax Tm CBs C M Ts3 150A, 600V , 225A, 480V Thermal magnetic Ts3 150A 600VAC/225A 480VAC Thermal Magnetic Trip Units Breaker Ts3N Breaker Ts3H Breaker IC at 480VAC kA 25 IC at 480VAC kA 50 IC at 480VAC 17 65 Ts3L 85 kA Rating Magnetic trip 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A Rating Magnetic trip 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A Rating Magnetic trip 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 2 pole, 600VAC/500VDC catalog number Ts3N015TW-2 Ts3N020TW-2 Ts3N025TW-2 Ts3N030TW-2 Ts3N035TW-2 Ts3N040TW-2 Ts3N050TW-2 Ts3N060TW-2 Ts3N070TW-2 Ts3N080TW-2 Ts3N090TW-2 Ts3N100TW-2 Ts3N125TW-2 Ts3N150TW-2 2 pole, 600VAC/500VDC catalog number Ts3H015TW-2 Ts3H020TW-2 Ts3H025TW-2 Ts3H030TW-2 Ts3H035TW-2 Ts3H040TW-2 Ts3H050TW-2 Ts3H060TW-2 Ts3H070TW-2 Ts3H080TW-2 Ts3H090TW-2 Ts3H100TW-2 Ts3H125TW-2 Ts3H150TW-2 2 pole, 600VAC/500VDC catalog number Ts3L015TW-2 Ts3L020TW-2 Ts3L025TW-2 Ts3L030TW-2 Ts3L035TW-2 Ts3L040TW-2 Ts3L050TW-2 Ts3L060TW-2 Ts3L070TW-2 Ts3L080TW-2 Ts3L090TW-2 Ts3L100TW-2 Ts3L125TW-2 Ts3L150TW-2 3 pole, 600VAC/DC catalog number Ts3N015TW Ts3N020TW Ts3N025TW Ts3N030TW Ts3N035TW Ts3N040TW Ts3N050TW Ts3N060TW Ts3N070TW Ts3N080TW Ts3N090TW Ts3N100TW Ts3N125TW Ts3N150TW 3 pole, 600VAC/DC catalog number Ts3H015TW Ts3H020TW Ts3H025TW Ts3H030TW Ts3H035TW Ts3H040TW Ts3H050TW Ts3H060TW Ts3H070TW Ts3H080TW Ts3H090TW Ts3H100TW Ts3H125TW Ts3H150TW 3 pole, 600VAC/DC catalog number Ts3L015TW Ts3L020TW Ts3L025TW Ts3L030TW Ts3L035TW Ts3L040TW Ts3L050TW Ts3L060TW Ts3L070TW Ts3L080TW Ts3L090TW Ts3L100TW Ts3L125TW Ts3L150TW NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. 17.24 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Ts3 150A, 600V , 225A, 480V , 100% rated Thermal magnetic Ts3 150A 600VAC/225A 480VAC Thermal Magnetic Trip Units 100% Rated Breaker Ts3NQ IC at 480VAC Rating Magnetic trip 3 pole 600VAC/DC catalog number 25 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A Ts3NQ015TW Ts3NQ020TW Ts3NQ025TW Ts3NQ030TW Ts3NQ035TW Ts3NQ040TW Ts3NQ050TW Ts3NQ060TW Ts3NQ070TW Ts3NQ080TW Ts3NQ090TW Ts3NQ100TW Ts3NQ125TW Ts3NQ150TW Breaker IC at 480VAC 65kA Ts3LQ 85kA Rating 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A Magnetic trip 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 3 pole catalog number Ts3LQ015TW Ts3LQ020TW Ts3LQ025TW Ts3LQ030TW Ts3LQ035TW Ts3LQ040TW Ts3LQ050TW Ts3LQ060TW Ts3LQ070TW Ts3LQ080TW Ts3LQ090TW Ts3LQ100TW Ts3LQ125TW Ts3LQ150TW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. Breaker Ts3HQ IC at 480VAC Rating 50kA 15A 20A 25A 30A 35A 40A 50A 60A 70A 80A 90A 100A 125A 150A Magnetic trip 500A 500A 500A 500A 500A 500A 500A 600A 700A 800A 900A 1000A 1250A 1500A 3 pole catalog number Ts3HQ015TW Ts3HQ020TW Ts3HQ025TW Ts3HQ030TW Ts3HQ035TW Ts3HQ040TW Ts3HQ050TW Ts3HQ060TW Ts3HQ070TW Ts3HQ080TW Ts3HQ090TW Ts3HQ100TW Ts3HQ125TW Ts3HQ150TW 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.25 1SXU000023C0202 Rev. A ax Tm CBs C M Ts3 150/225A 600VAC MCP/Molded case switch Magnetic only (MCP) Breaker Ts3L Ts3L Adjustment range 3 pole 600VAC Catalog number 175 1 12-36 20-60 40-120 100-300 200-600 400-1200 500-1500 600-1500 700-2100 Ts3L003MW Ts3L005MW Ts3L010MW Ts3L025MW Ts3L050MW Ts3L100MW Ts3L125MW Ts3L150MW Ts3L175MW 200 1 800-2400 Ts3L200MW IC at 480VAC Trip unit type Rating 25 25 25 25 85 85 85 85 65 Magnetic only Magnetic only Magnetic only Magnetic only Magnetic only Magnetic only Magnetic only Magnetic only Magnetic only 3 5 10 25 50 100 125 150 65 Magnetic only Molded case switch 2 Type IC at 480V (2) Magnetic trip Ts3H 50 50 1500 2250 Amps 3 pole 600V catalog number 150 225 1 Ts3H150DW Ts3H225DW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 When protected by a OCPD with appropriate ratings. 2 480 VAC maximum 17.26 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T4 250A, 600V Electronic and thermal magnetic Dimensions 3P Fixed Version 8.07H x 4.13W x 4.07D Weight 6.18 (Ibs) T4 General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. Standards The UL489/CSA 22.2 version of T4 also carries an IEC-60947-2 rating. Versions To meet all application requirements, the T4 is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage 240VAC 480VAC 600VAC 500VDC 1 600VDC 2 N 65 25 18 25 16 S 100 35 25 35 25 H 150 65 35 50 35 L 200 100 65 65 50 V 200 150 100 100 65 IEC 60947-2 Interrupting capacity (kA RMS) Voltage 230VAC 415VAC 690VAC 750VDC 2 N 70 36 20 16 S 85 50 25 25 H 100 70 40 36 L 200 120 70 50 V 200 200 80 70 Performance levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High - UL Current Limiting L = Extra high V = Very high - UL Current Limiting Number of poles 3 17 The T4 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 1 2 poles in series. 2 3 poles in series. 3 2 pole breakers available in N version only. 4 pole breakers available in N and H version only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.27 1SXU000023C0202 Rev. A ax Tm CBs C M T4 250A, 600V Adjustable thermal magnetic 20A - 250A Frame Breaker IC at 480VAC T4N 25 T4S T4H UL Current Limiting T4L T4V UL Current Limiting 35 65 100 150 Rating Magnetic trip 2 pole, 600VAC/600VDC catalog number 3 pole, 600VAC/600VDC catalog number 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 T4N125TW-2 T4N150TW-2 T4N200TW-2 T4N250TW-2 T4N125TW T4N150TW T4N200TW T4N250TW T4S125TW T4S150TW T4S200TW T4S250TW T4H125TW T4H150TW T4H200TW T4H250TW T4L125TW T4L150TW T4L200TW T4L250TW T4V125TW T4V150TW T4V200TW T4V250TW - - - - - - - - - - - - - - - - NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 17.28 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T4 250A, 600V 100% rated Adjustable thermal magnetic T M max CC Bs 30A - 250A Frame 100% rated Breaker IC at 480 VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 Magnetic trip Rating 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 125A 150A 200A 250A 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 625-1250 750-1500 1000-2000 1250-2500 3 pole, 600VAC/600VDC Catalog number T4NQ125TW T4NQ150TW T4NQ200TW T4NQ250TW T4SQ125TW T4SQ150TW T4SQ200TW T4SQ250TW T4HQ125TW T4HQ150TW T4HQ200TW T4HQ250TW T4LQ125TW T4LQ150TW T4LQ200TW T4LQ250TW T4VQ125TW T4VQ150TW T4VQ200TW T4VQ250TW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.29 1SXU000023C0202 Rev. A ax Tm CBs C M T4 250A, 600V Electronic (AC only) 100A Frame, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 Trip Unit 2 pole, 600V catalog number 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N100BW-2 T4N100CW-2 T4N100EW-2 - T4N100BW T4N100CW T4N100EW T4S100BW T4S100CW T4S100EW T4H100BW T4H100CW T4H100EW T4L100BW T4L100CW T4L100EW T4V100BW T4V100CW T4V100EW Trip Unit 2 pole, 600V catalog number 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N150BW-2 T4N150CW-2 T4N150EW-2 - T4N150BW T4N150CW T4N150EW T4S150BW T4S150CW T4S150EW T4H150BW T4H150CW T4H150EW T4L150BW T4L150CW T4L150EW T4V150BW T4V150CW T4V150EW Trip Unit 2 pole, 600V catalog number 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4N250BW-2 T4N250CW-2 T4N250EW-2 - T4N250BW T4N250CW T4N250EW T4S250BW T4S250CW T4S250EW T4H250BW T4H250CW T4H250EW T4L250BW T4L250CW T4L250EW T4V250BW T4V250CW T4V250EW 150A Frame, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 250A Frame, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 17 NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17.30 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T4 250A, 600V , 100% Rated Electronic (AC only) 100A Frame - 100% rated, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 Trip Unit 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ100BW T4NQ100CW T4NQ100EW T4SQ100BW T4SQ100CW T4SQ100EW T4HQ100BW T4HQ100CW T4HQ100EW T4LQ100BW T4LQ100CW T4LQ100EW T4VQ100BW T4VQ100CW T4VQ100EW 250A Frame - 100% rated, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 Trip Unit 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ250BW T4NQ250CW T4NQ250EW T4SQ250BW T4SQ250CW T4SQ250EW T4HQ250BW T4HQ250CW T4HQ250EW T4LQ250BW T4LQ250CW T4LQ250EW T4VQ250BW T4VQ250CW T4VQ250EW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 150A Frame - 100% rated, electronic trip unit (AC only) Breaker IC at 480VAC kA T4N 25 T4S 35 T4H UL Current Limiting 65 T4L 100 T4V UL Current Limiting 150 Trip Unit 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T4NQ150BW T4NQ150CW T4NQ150EW T4SQ150BW T4SQ150CW T4SQ150EW T4HQ150BW T4HQ150CW T4HQ150EW T4LQ150BW T4LQ150CW T4LQ150EW T4VQ150BW T4VQ150CW T4VQ150EW 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.31 1SXU000023C0202 Rev. A ax Tm CBs C M T4 250A, 600V Instantaneous only, MCP/Molded case switch Instantaneous only MCPs T4 - 250A Frame magnetic only (MCP - AC only) Breaker IC at 480VAC Trip unit type T4N 25kA Instantaneous only T4S 35kA Instantaneous only T4H 65kA Instantaneous only T4L 100kA Instantaneous only Rating Adjustment range 3 pole, 600VAC Catalog number 100A 150A 250A 100A 150A 250A 100A 150A 250A 100A 150A 250A 100-1000 150-1500 250-2500 100-1000 150-1500 250-2500 100-1000 150-1500 250-2500 100-1000 150-1500 250-2500 T4N100E5W T4N150E5W T4N250E5W T4S100E5W T4S150E5W T4S250E5W T4H100E5W T4H150E5W T4H250E5W T4L100E5W T4L150E5W T4L250E5W Molded case switch 1 Type IC at 480VAC Amps Magnetic trip 3 pole 600V catalog number T4N-D T4S-D T4H-D T4L-D T4V-D 25kA 35kA 65kA 100kA 150kA 250 250 250 250 250 3000 3000 3000 3000 3000 T4N250DW T4S250DW T4H250DW T4L250DW T4V250DW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 When protected by a OCPD with appropriate ratings. 17.32 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T5 400/600A, 600V Electronic and thermal magnetic Dimensions 3P Fixed Version 8.07H x 5.51W x 4.07D Weight 8.55 (Ibs) T5 General The T5 breaker is a 400/600 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. 3 Standards The UL489/CSA 22.2 version of T5 also carries an IEC-60947-2 rating. Versions To meet all application requirements, the T5 is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage N S H L V 240VAC 65 100 150 200 200 480VAC 25 35 65 100 150 600VAC 18 25 35 65 100 500VDC 1 25 35 50 65 100 600VDC 2 16 25 35 50 65 IEC 60947-2 Interrupting capacity (kA RMS) Voltage N S H L V 230VAC 70 85 100 200 200 415VAC 36 50 70 120 200 690VAC 20 25 40 70 80 750VDC 2 16 25 36 50 70 Performance levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High - UL Current Limiting L = Extra high V = Very high - UL Current Limiting Number of poles 4 17 The T5 is available in two, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 1 2 poles in series. 2 3 poles in series. 3 T5 600A not available with thermal magnetic trip unit. 4 2 pole available in N version only. 4 pole available in N and H version only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.33 1SXU000023C0202 Rev. A ax Tm CBs C M T5 400/600A, 600V Thermal magnetic 1 300A - 400A Frames - thermal-magnetic trip units Breaker IC at 480VAC kA T5N 25 T5S 35 T5H UL Current Limiting 65 T5L 100 T5V UL Current Limiting 150 Rating Magnetic trip 2 pole, 600VAC/500VDC catalog number 3 pole, 600VAC/600VDC catalog number 300A 400A 300A 400A 300A 400A 300A 400A 300A 400A 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 T5N300TW-2 T5N400TW-2 T5N300TW T5N400TW T5S300TW T5S400TW T5H300TW T5H400TW T5L300TW T5L400TW T5V300TW T5V400TW - - - - 300A - 400A Frames - 100% rated, thermal-magnetic Breaker IC at 480VAC T5N 25 T5S 35 T5H UL Current Limiting 65 T5L 100 T5V UL Current Limiting 150 Rating Magnetic trip 3 pole, 600VAC/600VDC Catalog number 300A 400A 300A 400A 300A 400A 300A 400A 300A 400A 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 1500-3000 2000-4000 T5NQ300TW T5NQ400TW T5SQ300TW T5SQ400TW T5HQ300TW T5HQ400TW T5LQ300TW T5LQ400TW T5VQ300TW T5VQ400TW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 T5 600A not available with Thermal Magnetic trip unit. 17.34 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T5 400/600A, 600V Electronic (AC only) 300A Frame, electronic trip unit (AC only) Breaker IC at 480VAC kA T5N 25 T5S 35 T5H UL Current Limiting 65 T5L 100 T5V UL Current Limiting 150 Trip Unit 2 pole, 600V catalog number 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N300BW-2 T5N300CW-2 T5N300EW-2 - T5N300BW T5N300CW T5N300EW T5S300BW T5S300CW T5S300EW T5H300BW T5H300CW T5H300EW T5L300BW T5L300CW T5L300EW T5V300BW T5V300CW T5V300EW Trip Unit 2 pole, 600V catalog number 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N400BW-2 T5N400CW-2 T5N400EW-2 - T5N400BW T5N400CW T5N400EW T5S400BW T5S400CW T5S400EW T5H400BW T5H400CW T5H400EW T5L400BW T5L400CW T5L400EW T5V400BW T5V400CW T5V400EW 400A Frame, electronic trip unit (AC only) Breaker IC at 480VAC kA T5N 25 T5S 35 T5H UL Current Limiting 65 T5L 100 T5V UL Current Limiting 150 600A Frame, electronic trip unit (AC only) 1 Breaker IC at 480VAC kA T5N 25 T5S 35 T5H 65 T5L 100 T5V 150 Trip Unit 3 pole, 600V catalog number PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG T5N600BW T5N600CW T5N600EW T5S600BW T5S600CW T5S600EW T5H600BW T5H600CW T5H600EW T5L600BW T5L600CW T5L600EW T5V600BW T5V600CW T5V600EW 17 NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 1 T5 600A not available in 2 pole version. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.35 1SXU000023C0202 Rev. A ax Tm CBs C M T5 400/600A, 600V , 100% Rated 1 Electronic (AC only) 300A Frame - 100% rated, electronic trip units (AC only) Breaker IC at 480VAC kA T5N 25 T5S 35 T5H UL Current 65 T5L 100 T5V UL Current 150 limiting limiting Trip Unit PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG 3 pole, 600V catalog number T5NQ300BW T5NQ300CW T5NQ300EW T5SQ300BW T5SQ300CW T5SQ300EW T5HQ300BW T5HQ300CW T5HQ300EW T5LQ300BW T5LQ300CW T5LQ300EW T5VQ300BW T5VQ300CW T5VQ300EW 400A Frame - 100% rated, electronic trip units (AC only) Breaker IC at 480VAC kA T5N 25 T5S 35 T5H UL Current 65 T5L 100 T5V UL Current 150 limiting limiting Trip Unit PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG PR221 LS/I PR222 LSI PR222 LSIG 3 pole, 600V catalog number T5NQ400BW T5NQ400CW T5NQ400EW T5SQ400BW T5SQ400CW T5SQ400EW T5HQ400BW T5HQ400CW T5HQ400EW T5LQ400BW T5LQ400CW T5LQ400EW T5VQ400BW T5VQ400CW T5VQ400EW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 T5 600A not available in 100% rated frame. 17.36 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T5 400/600A, 600V Instantaneous only, MCP/Molded case switch T M max CC Bs T5 - 400A Frame, magnetic only (MCP - AC only) Breaker IC at 480VAC Trip unit type Rating Adjustment range 3 pole, 600VAC Catalog number T5N 25kA Instantaneous only T5S 35kA Instantaneous only T5H 65kA Instantaneous only T5L 100kA Instantaneous only 300A 400A 300A 400A 300A 400A 300A 400A 300-3000 400-4000 300-3000 400-4000 300-3000 400-4000 300-3000 400-4000 T5N300E5W T5N400E5W T5S300E5W T5S400E5W T5H300E5W T5H400E5W T5L300E5W T5L400E5W Rating Adjustment range 3 pole, 600VAC Catalog number 600A 600-6000 T5N600E5W 600A 600-6000 T5S600E5W 600A 600-6000 T5H600E5W 600A 600-6000 T5L600E5W T5 - 600A Frame, magnetic only (MCP - AC only) Breaker IC at 480VAC T5N 25kA T5S 35kA T5H 65kA T5L 100kA Trip unit type Instantaneous only Instantaneous only Instantaneous only Instantaneous only Molded case switch 1 Type IC at 480VAC Amps Magnetic trip 3 pole 600V catalog number T5N-D T5S-D T5H-D T5L-D T5V-D T5N-D T5S-D T5H-D T5L-D T5V-D 25kA 35kA 65kA 100kA 150kA 25kA 35kA 65kA 100kA 150kA 400 400 400 400 400 600 600 600 600 600 5000 5000 5000 5000 5000 6000 6000 6000 6000 6000 T5N400DW T5S400DW T5H400DW T5L400DW T5V400DW T5N600DW T5S600DW T5H600DW T5L600DW T5V600DW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 1 When protected by a OCPD with appropriate ratings. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.37 1SXU000023C0202 Rev. A ax Tm CBs C M T6 600A, 800A, 600V Thermal magnetic and electronic Dimensions 3P Fixed Version 10.55H x 8.26W x 4.07D Weight 20.9 (Ibs) T6 General The T6 breaker is an 800 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. The T6 is available as a 600 or 800A frame. Standards The UL489/CSA 22.2 version of T6 also carries an IEC-60947-2 rating. Versions To meet all application requirements, the T6 is available in the following versions: T = Thermal-magnetic, fixed B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) Trip functions UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage N S H L 240VAC 480VAC 600VAC 500VDC 1 65 35 20 35 100 50 25 35 200 65 35 50 200 100 42 65 600VDC 2 20 20 35 50 IEC 60947-2 Interrupting capacity (kA RMS) Voltage N S H L 230VAC 415VAC 690VAC 70 36 20 16 85 50 22 20 100 70 25 36 200 100 30 50 750VDC 2 These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High L = Extra high 17 Number of poles 3 The T6 is available as a three and four pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 1 2 poles in series. 2 3 poles in series. 3 4 pole available N and H version only. 17.38 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T6 600A, 800A, 600V Thermal magnetic and electronic T6 600A, 800A, 600V Thermal Magnetic Trip Units Breaker IC at 480 VAC kA T6N 35 T6S 50 T6H 65 T6L 100 T6 600A, 600V Electronic Trip Units Rating Magnetic trip 3 pole, 600VAC/600VDC catalog number Breaker IC at 480VAC 600A 800A 600A 800A 600A 800A 600A 800A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A T6N600TW T6N800TW T6S600TW T6S800TW T6H600TW T6H800TW T6L600TW T6L800TW T6N 35 T6S 50 T6H 65 T6L 100 T6 600A, 800A, 600V Thermal Magnetic Trip Units 100% rated Breaker IC at 480 VAC kA T6N 35 T6S 50 T6H 65 T6L 100 Rating Magnetic trip 600A 800A 600A 800A 600A 800A 600A 800A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3000 - 6000A 4000 - 8000A 3 pole, 600VAC/600VDC catalog number T6NQ600TW T6NQ800TW T6SQ600TW T6SQ800TW T6HQ600TW T6HQ800TW T6LQ600TW T6LQ800TW Trip type Adjustment PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG T6 800A, 600V Electronic Trip Units Breaker IC at 480VAC T6N 35 T6S 50 T6H 65 T6L 100 Trip type Adjustment PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG 3 pole, 600VAC catalog number T6N600BW T6N600CW T6N600EW T6S600BW T6S600CW T6S600EW T6H600BW T6H600CW T6H600EW T6L600BW T6L600CW T6L600EW 3 pole, 600VAC catalog number T6N800BW T6N800CW T6N800EW T6S800BW T6S800CW T6S800EW T6H800BW T6H800CW T6H800EW T6L800BW T6L800CW T6L800EW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.39 1SXU000023C0202 Rev. A ax Tm CBs C M T6 600A, 800A, 600V Thermal magnetic and electronic T6 600A, 600V Electronic Trip Units 100% Rated Breaker IC at 480VAC T6N 35 T6S 50 T6H 65 T6L 100 Trip type PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 Adjustment LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG T6 800A, 600V Electronic Trip Units 100% Rated Breaker IC at 480VAC T6N 35 T6S 50 T6H 65 T6L 100 Trip type PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 PR221 PR222 PR222 Adjustment LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG LS/I LSI LSIG 3 pole, 600VAC catalog number T6NQ600BW T6NQ600CW T6NQ600EW T6SQ600BW T6SQ600CW T6SQ600EW T6HQ600BW T6HQ600CW T6HQ600EW T6LQ600BW T6LQ600CW T6LQ600EW 3 pole, 600VAC catalog number T6NQ800BW T6NQ800CW T6NQ800EW T6SQ800BW T6SQ800CW T6SQ800EW T6HQ800BW T6HQ800CW T6HQ800EW T6LQ800BW T6LQ800CW T6LQ800EW T6 600A, 600V Electronic Trip Units Instantaneous Only Breaker T6N T6S T6H T6L IC at 480VAC kA 35 50 65 100 Trip type PR221 PR221 PR221 PR221 Adjustment Range 600-6000 600-6000 600-6000 600-6000 T6 800A, 600V Electronic Trip Units Instantaneous Only Breaker T6N T6S T6H T6L IC at 480VAC kA 35 50 65 100 3 pole, 600VAC catalog number T6N600E5W T6S600E5W T6H600E5W T6L600E5W PR221 PR221 PR221 PR221 Adjustment Range 800-8000 800-8000 800-8000 800-8000 3 pole, 600VAC catalog number T6N800E5W T6S800E5W T6H800E5W T6L800E5W Trip type T6 800A, 600V Molded Case Switch Breaker IC at 480VAC 1 Amp Magnetic Trip 3 pole, 600VAC catalog number T6H 65 800 10,000 T6H800DW 17 1 When protected by a OCPD with appropriate ratings. 17.40 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T7 (Toggle) 1000A, 1200A, 600V Electronic Dimensions 3P Fixed Version 10.55H x 8.26W x 6.06D Weight 21.4 (Ibs) T7 General The T7 breaker is a 1200 amp frame with a microprocessor based over current protective trip system. Standards The UL489/CSA 22.2 version of T7 also carries an IEC-60947-2 rating. UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage S H L 240VAC 480VAC 600VAC 65 50 25 100 65 50 150 100 65 Versions To meet all application requirements, the T7 is available in the following versions: B = Selectable & adjustable LI or LS -- Dip switch settings C = Adjustable LSI -- Dip switch settings E = Adjustable LSIG -- Dip switch settings D = Molded Case Switch P = LI -- LCD display R = LSI -- LCD display S = LSIG -- LCD display IEC 60947-2 Interrupting capacity (kA RMS) Voltage S H L 230VAC 415VAC 690VAC 85 50 30 100 70 42 200 120 50 Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance levels Each version is also available in different maximum fault interrupting levels: S = Standard H = High L = Extra high Number of poles 1 The T7 is available as a 3 and 4 pole breaker. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details. 17 1 4 Pole available S, H and L version. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.41 1SXU000023C0202 Rev. A ax Tm CBs C M T7 1000A, 1200A, 600V Electronic T7S, 1000A, 600V Electronic Breaker T7S IC at 480VAC kA 50 Trip type Adjustment 3 pole, 600VAC catalog number PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG T7S1000BW T7S1000CW T7S1000EW T7S1000PW T7S1000RW T7S1000SW T7S, 1200A, 600V Electronic Breaker T7S IC at 480VAC kA Trip type Adjustment 50 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG T7H IC at 480VAC kA Trip type Adjustment 65 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG T7H, 1200A, 600V Electronic Breaker T7H Breaker T7L IC at 480VAC kA Trip type Adjustment PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG IC at 480VAC kA Trip type Adjustment 100 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P 100 T7L1000BW T7L1000CW T7L1000EW T7L1000PW T7L1000RW T7L1000SW T7L, 1200A, 600V Electronic Breaker T7L LS/I LSI LSIG LI LSI LSIG 3 pole, 600VAC catalog number 3 pole, 600VAC catalog number T7L1200BW T7L1200CW T7L1200EW T7L1200PW T7L1200RW T7L1200SW NOTE: See pages 17.71-17.83 for electrical/mechanical accessories. T7H, 1000A, 600V Electronic Breaker 3 pole, 600VAC catalog number T7S1200BW T7S1200CW T7S1200EW T7S1200PW T7S1200RW T7S1200SW T7L, 1000A, 600V Electronic IC at 480VAC kA Trip type 65 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3 pole, 600VAC catalog number T7H1000BW T7H1000CW T7H1000EW T7H1000PW T7H1000RW T7H1000SW 3 pole, 600VAC catalog number T7H1200BW T7H1200CW T7H1200EW T7H1200PW T7H1200RW T7H1200SW 17 17.42 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T7 1000A, 1200A, 600V Electronic, 100% rated T7S, 1000A, 600V Electronic, 100% rated Breaker T7S IC at 480VAC kA Trip type Adjustment 50 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG T7S, 1200A, 600V Electronic, 100% rated Breaker T7S IC at 480VAC kA Trip type Adjustment 50 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG 3 pole, 600VAC Catalog number T7SQ1000BW T7SQ1000CW T7SQ1000EW T7SQ1000PW T7SQ1000RW T7SQ1000SW 3 pole, 600VAC Catalog number T7SQ1200BW T7SQ1200CW T7SQ1200EW T7SQ1200PW T7SQ1200RW T7SQ1200SW T7L, 1000A, 600V Electronic, 100% rated Breaker T7L IC at 480VAC kA Trip type 100 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P LS/I LSI LSIG LI LSI LSIG IC at 480VAC kA Trip type Adjustment 100 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment T7L, 1200A, 600V Electronic, 100% rated Breaker T7L LS/I LSI LSIG LI LSI LSIG 3 pole, 600VAC Catalog number T7LQ1000BW T7LQ1000CW T7LQ1000EW T7LQ1000PW T7LQ1000RW T7LQ1000SW 3 pole, 600VAC Catalog number T7LQ1200BW T7LQ1200CW T7LQ1200EW T7LQ1200PW T7LQ1200RW T7LQ1200SW NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. T7H, 1000A, 600V Electronic, 100% rated Breaker T7H IC at 480VAC kA Trip type 65 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG T7H, 1200A, 600V Electronic, 100% rated Breaker T7H IC at 480VAC kA Trip type 65 PR231/P PR232/P PR331/P PR332/P PR332/P PR332/P Adjustment LS/I LSI LSIG LI LSI LSIG 3 pole, 600VAC Catalog number T7HQ1000BW T7HQ1000CW T7HQ1000EW T7HQ1000PW T7HQ1000RW T7HQ1000SW 3 pole, 600VAC Catalog number T7HQ1200BW T7HQ1200CW T7HQ1200EW T7HQ1200PW T7HQ1200RW T7HQ1200SW 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.43 1SXU000023C0202 Rev. A ax Tm CBs C M T7 1200A, 600V Electronic/Molded case switch T7 1200A, 600V Molded case switch Breaker T7H IC at 480VAC kA 1 - Amp 1200 Magnetic trip 20,000 3 pole, 600VAC Catalog number T7H1200DW NOTE: See pages 17.67 - 17.79 for electrical/mechanical accessories. T7 1000 - 1200A, 600V Motor circuit protection Electronic trip, instantaneous only Breaker IC at 480VAC kA 1 Amp T7S 50 1000 Catalog number T7S1000E5W T7H 65 1000 T7H1000E5W T7L 100 1000 T7L1000E5W T7S 50 1200 T7S1200E5W T7H 65 1200 T7H1200E5W T7L 100 1200 T7L1200E5W NOTE: See pages 17.71 - 17.83 for electrical/mechanical accessories. 17 1 When protected by a OCPD with appropriate ratings. 17.44 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T7M (Stored energy) 1000A, 1200A, 600V Electronic Dimensions 3P Fixed Version 10.55H x 8.26W x 7D Weight 24.25 (Ibs) T7M General The T7M breaker is a stored energy 1200A frame with a microprocessor based overcurrent protective trip system. Standards The UL489/CSA 22.2 version of T7M also carries an IEC-60947-2 rating. UL489 / CSA C22.2 Interrupting capacity (kA RMS) Voltage S H L 240VAC 480VAC 600VAC 65 50 25 100 65 50 150 100 65 Versions To meet all application requirements, the T7M is available in the following versions: B = Selectable & adjustable LI or LS -- Dip switch setting C = Adjustable LSI -- Dip switch setting E = Adjustable LSIG -- Dip switch setting D = Molded Case Switch P = LI -- LCD display R = LSI -- LCD display S = LSIG -- LCD display IEC 60947-2 Interrupting capacity (kA RMS) Voltage S H L 230VAC 415VAC 690VAC 85 50 30 100 70 42 200 120 50 Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance levels Each version is also available in different maximum fault interrupting levels: S = Standard H = High L = Extra high Number of poles The T7M is available as a three and four pole breaker. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17 17.45 1SXU000023C0202 Rev. A ax Tm CBs C M T 7 M T7M 1000A, 1200A, 600V Electronic Locking provisions: X = None A = Keylock; B = Button guard C = Padlock provision (open) F = A+B Accessories: X = None A = Mechanical counter B = Trip signal C = Trip signal and reset 24-30 VAC/DC D = Trip signal and reset 110-130 VAC/DC E = Trip signal and reset 200-240 VAC/DC F = A+C; G=A+D; H=A+E Undervoltage: 0 = None; A = 24 VAC/DC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110...120 VAC/DC F = 120...127 VAC/DC; G = 220...240 VAC/DC; H = 240...250 VAC/DC; J = 380...400 VAC; K = 415...440 VAC Shunt trip: 0 = None; A = 24 VAC/DC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110...120 VAC/DC F = 120...127 VAC/DC; G = 220...240 VAC/DC; H = 240...250 VAC/DC J = 380...400 VAC; K = 415...440 VAC Spring Charging Motor: 0 = None; A = 24...30 VAC/DC; B = 48...60 VAC/DC; C = 100...130 VAC/DC; D = 220...250 VAC/DC E = 380...415 VAC; F = Springs charged 24 VDC; G = Springs charged 250 VAC/DC; H=A+F; J=B+F; K=C+F; L=D+F; M=E+F; N=A+G; P=B+G; Q=C+G; R=D+G; S=E+G Auxilary Contacts: 0 = None A = 2 Form C (400 VAC); B = 2 Form C (24 VDC); C=Ready to close 24 VDC; D = Ready to close 250 VAC/DC Closing Coil: 0 = None; A = 24 VAC/DC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110...120 VAC/DC; F = 120...127 VAC/DC; G = 220...240 VAC/DC; H = 240...250 VAC/DC; J = 380...400 VAC; K = 415...440 VAC 17 Trip Unit Accessories: 0 = None; A = PR330V; B = PR330/D-M; C = A + B (PR332/P only) Trip Unit: A = PR231/P-I (MCP); B = PR231/P-LS/I; C = PR232/P-LSI; D = Non-Automatic (MCS); E = PR331/P-LSIG; P = PR332/P-LI; R = PR332/P-LSI; S = PR332P-/LSIG Rating Plug: 0 = None; Non -Automatic (MCS) A = 400A; B = 600/630A; C = 800A; D = 1000A; E = 1200/1250A F = 1600A (IEC only) Frame Ampere rating: A3 = 800 A (3P) IEC only; P3 = 1000 A (3P); B3 = 1200/1250 A (3P); C3 1600 A (3P IEC only) A4 = 800 A (4P) IEC only; P4 = 1000 A (4P); B4 = 1200/1250 A (4P); C4 1600 A (4P IEC only) Version: 0 = Fixed non-automatic (MCS); B = UL fixed; Q = UL fixed 100% rated; F = IEC fixed Breaking Capacity: S, H, L, V = IEC, T7 800, 1000, 1250A only); D = MCS (IEC) Call factory for IEC breaker pricing 17.46 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T7M 1000A, 1200A, 600V - Three Pole Electronic T7M-S, 1000A, 600V Electronic Breaker T7M-S IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H, 1000A, 600V Electronic Breaker T7M-H IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L, 1000A, 600V Electronic Breaker T7M-L IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 3 pole, 600V Catalog number T7MSBP3DB000000XX T7MSBP3DC000000XX T7MSBP3DE000000XX T7MSBP3DP000000XX T7MSBP3DR000000XX T7MSBP3DS000000XX 3 pole, 600V Catalog number T7MHBP3DB000000XX T7MHBP3DC000000XX T7MHBP3DE000000XX T7MHBP3DP000000XX T7MHBP3DR000000XX T7MHBP3DS000000XX 3 pole, 600V Catalog number T7MLBP3DB000000XX T7MLBP3DC000000XX T7MLBP3DE000000XX T7MLBP3DP000000XX T7MLBP3DR000000XX T7MLBP3DS000000XX T7M-S, 1200A, 600V Electronic Breaker T7M-S IC at 480VAC kA Trip unit 3 pole, 600V Catalog number 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7MSBB3EB000000XX T7MSBB3EC000000XX T7MSBB3EE000000XX T7MSBB3EP000000XX T7MSBB3ER000000XX T7MSBB3ES000000XX IC at 480VAC kA Trip unit 3 pole, 600V Catalog number 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7MHBB3EB000000XX T7MHBB3EC000000XX T7MHBB3EE000000XX T7MHBB3EP000000XX T7MHBB3ER000000XX T7MHBB3ES000000XX T7M-H, 1200A, 600V Electronic Breaker T7M-H T7M-L, 1200A, 600V Electronic Breaker T7M-L IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 3 pole, 600V Catalog number T7MLBB3EB000000XX T7MLBB3EC000000XX T7MLBB3EE000000XX T7MLBB3EP000000XX T7MLBB3ER000000XX T7MLBB3ES000000XX 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.47 1SXU000023C0202 Rev. A ax Tm CBs C M T7M 1000A, 1200A, 600V - Three Pole Electronic 100% Rated T7M-S, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-S T7M-H, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H T7M-L, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L 3 pole, 600V Catalog number T7MSQP3DB000000XX T7MSQP3DC000000XX T7MSQP3DE000000XX T7MSQP3DP000000XX T7MSQP3DR000000XX T7MSQP3DS000000XX 3 pole, 600V Catalog number T7MHQP3DB000000XX T7MHQP3DC000000XX T7MHQP3DE000000XX T7MHQP3DP000000XX T7MHQP3DR000000XX T7MHQP3DS000000XX 3 pole, 600V Catalog number T7MLQP3DB000000XX T7MLQP3DC000000XX T7MLQP3DE000000XX T7MLQP3DP000000XX T7MLQP3DR000000XX T7MLQP3DS000000XX T7M-S, 1200A, 600V Electronic Breaker T7M-S IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H, 1200A, 600V Electronic Breaker T7M-H IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L, 1200A, 600V Electronic Breaker T7M-L IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 3 pole, 600V Catalog number T7MSQB3EB000000XX T7MSQB3EC000000XX T7MSQB3EE000000XX T7MSQB3EP000000XX T7MSQB3ER000000XX T7MSQB3ES000000XX 3 pole, 600V Catalog number T7MHQB3EB000000XX T7MHQB3EC000000XX T7MHQB3EE000000XX T7MHQB3EP000000XX T7MHQB3ER000000XX T7MHQB3ES000000XX 3 pole, 600V Catalog number T7MLQB3EB000000XX T7MLQB3EC000000XX T7MLQB3EE000000XX T7MLQB3EP000000XX T7MLQB3ER000000XX T7MLQB3ES000000XX 17 17.48 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T7M 1000A, 1200A, 600V - Four Pole Electronic T7M-S, 1000A, 600V Electronic Breaker T7M-S IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 4 pole, 600V Catalog number T7MSBP4DB000000XX T7MSBP4DC000000XX T7MSBP4DE000000XX T7MSBP4DP000000XX T7MSBP4DR000000XX T7MSBP4DS000000XX T7M-H, 1000A, 600V Electronic Breaker T7M-H T7M-L Breaker T7M-S IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H, 1200A, 600V Electronic IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 4 pole, 600V Catalog number T7MHBP4DB000000XX T7MHBP4DC000000XX T7MHBP4DE000000XX T7MHBP4DP000000XX T7MHBP4DR000000XX T7MHBP4DS000000XX Breaker T7M-H IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L, 1200A, 600V Electronic T7M-L, 1000A, 600V Electronic Breaker T7M-S, 1200A, 600V Electronic IC at 480VAC kA Trip unit 4 pole, 600V Catalog number 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7MLBP4DB000000XX T7MLBP4DC000000XX T7MLBP4DE000000XX T7MLBP4DP000000XX T7MLBP4DR000000XX T7MLBP4DS000000XX Breaker T7M-L IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 4 pole, 600V Catalog number T7MSBB4EB000000XX T7MSBB4EC000000XX T7MSBB4EE000000XX T7MSBB4EP000000XX T7MSBB4ER000000XX T7MSBB4ES000000XX 4 pole, 600V Catalog number T7MHBB4EB000000XX T7MHBB4EC000000XX T7MHBB4EE000000XX T7MHBB4EP000000XX T7MHBB4ER000000XX T7MHBB4ES000000XX 4 pole, 600V Catalog number T7MLBB4EB000000XX T7MLBB4EC000000XX T7MLBB4EE000000XX T7MLBB4EP000000XX T7MLBB4ER000000XX T7MLBB4ES000000XX 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.49 1SXU000023C0202 Rev. A ax Tm CBs C M T7M 1000A, 1200A, 600V - Four Pole Electronic 100% Rated T7M-S, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-S T7M-H, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H T7M-L, 1000A, 600V Electronic Breaker IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L 4 pole, 600V Catalog number T7MSQP4DB000000XX T7MSQP4DC000000XX T7MSQP4DE000000XX T7MSQP4DP000000XX T7MSQP4DR000000XX T7MSQP4DS000000XX 4 pole, 600V Catalog number T7MHQP4DB000000XX T7MHQP4DC000000XX T7MHQP4DE000000XX T7MHQP4DP000000XX T7MHQP4DR000000XX T7MHQP4DS000000XX 4 pole, 600V Catalog number T7MLQP4DB000000XX T7MLQP4DC000000XX T7MLQP4DE000000XX T7MLQP4DP000000XX T7MLQP4DR000000XX T7MLQP4DS000000XX T7M-S, 1200A, 600V Electronic Breaker T7M-S IC at 480VAC kA Trip unit 50 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-H, 1200A, 600V Electronic Breaker T7M-H IC at 480VAC kA Trip unit 65 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG T7M-L, 1200A, 600V Electronic Breaker T7M-L IC at 480VAC kA Trip unit 100 PR231/P-LS/I PR232/P-LSI PR331/P-LSIG PR332/P-LI PR332/P-LSI PR332/P-LSIG 4 pole, 600V Catalog number T7MSQB4EB000000XX T7MSQB4EC000000XX T7MSQB4EE000000XX T7MSQB4EP000000XX T7MSQB4ER000000XX T7MSQB4ES000000XX 4 pole, 600V Catalog number T7MHQB4EB000000XX T7MHQB4EC000000XX T7MHQB4EE000000XX T7MHQB4EP000000XX T7MHQB4ER000000XX T7MHQB4ES000000XX 4 pole, 600V Catalog number T7MLQB4EB000000XX T7MLQB4EC000000XX T7MLQB4EE000000XX T7MLQB4EP000000XX T7MLQB4ER000000XX T7MLQB4ES000000XX 17 17.50 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T7M 1200A, 600V - Molded Case Swich T M max CC Bs T7M 1200A, 600V Molded case switch Breaker T7M-H IC at 480VAC kA - Amp 1200 Magnetic override 20,000 3 pole, 600VAC Catalog number T7MH0B30D000000XX T7M 1000 - 1200A, 600V Motor circuit protection Electronic trip, instantaneous only Breaker IC at 480VAC kA Amp Catalog number T7M-S T7M-H T7M-L 50 65 100 1000 1000 1000 T7MSBP3DA000000XX T7MHBP3DA000000XX T7MLBP3DA000000XX T7M-S 50 1200 T7MSBB3EA000000XX T7M-H 65 1200 T7MHBB3EA000000XX T7M-L 100 1200 T7MLBB3EA000000XX 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.51 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Electrical T7M Field installation Catalog number Closing coils 1 415...440 VAC 380...400 VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/VDC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VAC/DC T7M KT7MXC1 KT7MXC1 KT7MXC2 KT7MXC3 KT7MXC4 KT7MXC5 KT7MXC6 KT7MXC7 KT7MXC8 KT7MXC9 KT7MXC0 Field installation Catalog number Auxiliary contacts 2 Form C 400 VAC 2 Form C 24 VDC T7/T7M Field installation Catalog number Ready to close auxiliaries (IEC) 24 VDC 250 VAC/DC T7M KT7XAS2 KT7XAS2-AU KT7MX-RTC24V KT7MX-RTC250V Signals the circuit breaker is ready to accept a close signal if the following five conditions are met: * Circuit breaker is open * Any opening coil de-energized * Opening solenoid armed * Closing springs are charged * Any undervoltage coil energized Field/factory installation Catalog number Trip signal T7M Contact for signalling electronic trip unit tripped 1 Field installation Catalog number Spring charging motor 1 380...415 VAC 220...250 VAC/DC 100...130 VAC/DC 48...60 VAC/DC 24...30 VAC/DC T7M KT7MXM* Contact signalling springs charged 24 VDC Contact signalling springs charged 250 VAC/DC 415...440 VAC 380...400 VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VAC/DC 17 415...440 VAC 380...400 VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VAC/DC T7/T7M KT7XS1 KT7XS2 KT7XS3 KT7XS4 KT7XS5 KT7XS6 KT7XS7 KT7XS8 KT7XS9 KT7XS0 Field installation Catalog number Undervoltage Trip reset (IEC) T7M KT7MX-SC24V KT7MX-SC250V Field installation Catalog number Shunt trip T7/T7M KT7XU* KT7MXM2 KT7MXM3 KT7MXM5 KT7MXM7 KT7MXM9 Field installation Catalog number Spring charged contacts (IEC) T7M KT7MTS Trip reset command 24-30 VAC/DC Trip reset command 110-130 VAC/DC Trip reset command 200-240 VAC/DC KT7XU1 KT7XU2 KT7XU3 KT7XU4 KT7XU5 KT7XU6 KT7XU7 KT7XU8 KT7XU9 KT7XU0 Field installation Catalog number KT7MX-TR9 KT7MX-TR5 KT7MX-TR4 Allows remote circuit breaker resetting following a trip of the overcurrent release 1 Not Suitable for T7 toggle version. 2 Always supplied with PR332/P trip units 17.52 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Mechanical T7M Terminal lugs Frame Size Wire Size Catalog number (3 pieces) Catalog number (4 pieces) T7/T7M 1 (4) 4/0-500 kxmil KT7X1200-3 1 KT7X1200-4 1 Terminal covers - Low profile - kit includes two pieces-fixed breakers Frame Size Catalog number (3 pole) Catalog number (4 pole) T7/T7M 2 KT7XLTC-3 KT7XLTC-4 Terminal covers - High profile - kit includes two pieces Frame Size Catalog number (3 pole) Catalog number (4 pole) T7/T7M KT7XHTC-3 KT7XHTC-4 Frame Size Catalog number 4 pcs (3 pole) Catalog number 6 pcs (4 pole) T7/T7M KT7PBL-3 2 KT7PBL-4 Frame Catalog number 4 pcs (3 pole) Catalog number 6 pcs (4 pole) T7/T7M KT7PBH-3 KT7PBH-4 Phase barriers - Low profile 100mm - 3.93 in Phase barriers - High profile 200mm - 7.87 in Mechanical operation counter 3 Field/factory installation Catalog number Frame T7M KT7MXMC Mechanical counter 3 Transparent protection for buttons 3 Field/factory installation Catalog number Frame T7M KT7MXMC Button Guard 3 Padlock provision 3 KT7MXPG Field/factory installation Catalog number Frame T7M Padlock-open 3 KT7MXLDO Frame Sizer Key lock open position Field/factory installation Catalog number T7M Key lock on breaker open position key lock # 20005 3 Key lock on breaker open position different keys 3 KT7XPG Key locks KT7MKL2 17 KT7MKL1 Mechanical interlock Catalog part number Frame KT7MKL* T7M/T7M Cable T7 Mechanical interlock plate - drawout Mechanical interlock plate - fixed IP54 door protection 3 Field Installation Catalog number Frame T7M KT7XMLC KT7XMLPW KT7XMLPF Protective cover 3 KT7MXDC 1 Comes standard with high profile terminal covers. 2 Fixed breakers only 3 Not Suitable for T7 toggle version Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.53 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Mechanical T7M Draw-out kits Frame Adaptor moving part T7M 3 Pole with horizontal/vertical terminals KT7XWMK Sliding contact blocks T7M - Drawout Sliding Contacts Left Block Spring charging motor Spring charged contact Ready to close contact Early auxiliary contact Contact for trip coil trip release Trip reset Center Block PR331 PR332 Right Block Auxiliary contacts Shunt trip Closing coil Undervoltage release Fixed Part KT7WFHR Moving part breaker Fixed part cradle KT7XSCMP-L KT7XSCFP-L KT7XSCMP-C KT7XSCFP-C KT7XSCMP-R KT7XSCFP-R If at least one of the accessories in the table is installed on the breaker - respective pair of contact blocks must be installed on the fixed part (cradle) and the moving part (breaker) Position key lock Locks drawout breaker in racked-in/test-isoloated/racked-out Key #20005 Different keys Catalog number KT7XPL2 KT7XPL1 Position lock accessory Added to position lock allows breaker to be locked in racked out postion only Position lock accessory Catalog number KT7XPLA Rating plugs (UL) Catalog number 400A Rating plug 600A Rating plug 800A Rating plug 1000A Rating plug 1200A Rating plug T7/T7M Modules for T7M PR332 trip units T7/T7M 17 PR330/D-M PR330/VT7MX1 PR330/D-M Battery power supply unit 2 External Bluetooth communication module Includes diagnostic software for Modbus/Bluetooth networks Test configuration unit Allows tripping of all electronic trip units for Tmax (except PR33x) Current sensor for external neutral PR030/B Catalog number Accessory connector For wiring to internal accessories 17.54 1SXU000023C0202 Rev. A Catalog number Voltage module 1 Communication module (Modbus RTU) External units T7/T7M KT7X0400RP KT7X0600RP KT7X0800RP KT7X1000RP KT7X1200RP BT030 PR010/T K7TUT KT7NCT Catalog number KT7XAC Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Technical data T7/T7M Shunt tips, closing coil, Undervoltage & spring charging motor Undervoltage Standard shunt trip Inrush Power Consumption T7/T7M Inrush Power Consumption Voltage 24 VAC/DC 30 VAC/DC 48 VAC/DC 60 VAC/DC 110...120 VAC/DC 120...127 VAC/DC 220...240 VAC/DC 240...240 VAC/DC 380...400 VAC 415...440 VAC AC (VA) 300 300 300 300 300 300 300 300 300 300 DC (W) 300 300 300 300 300 300 300 300 -- -- Opening time (ms) 20 20 Closing coil Voltage 24 VAC/DC 30 VAC/DC 110...120 VAC/DC 120...127 VAC/DC 220...240 VAC 240...250 VAC/DC 380...400 VAC 415...440 VAC Opening time (ms) T7/T7M AC (VA) 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 25 DC (W) 3.5 3.5 3.5 3.5 3.5 3.5 -- -- 25 Spring charging motor Inrush Power Consumption Voltage 24 VAC/DC 30 VAC/DC 48 VAC/DC 60 VAC/DC 110...120 VAC/DC 120...127 VAC/DC 220...240 VAC/DC 240...240 VAC/DC 380...400 VAC 415...440 VAC Opening time (ms) T7M AC (VA) 300 300 300 300 300 300 300 300 300 300 20 Power Consumption DC (W) 300 300 300 300 300 300 300 300 -- -- 20 Voltage 24....30 VAC/DC 48...60 VAC/DC 100...130 VAC/DC 220...250 VAC/DC 380...415 VAC Opening voltage (% Un) Charging time (s) T7M AC (VA) 100 100 100 100 100 85-110 8-10 DC (W) 100 100 100 100 -- 85-110 8-10 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.55 1SXU000023C0202 Rev. A ax Tm CBs C M T8 1600/2000/2500/3000A, 600VAC Electronic trip Dimensions 3P Fixed Version 15.0H x 16.8W x 11.2D Weight 161 lbs (1600, 2000, 2500A) 236 lbs (3000A) T8 General The T8 is available in a 1600A, 2000A, 2500A, 3000A frame with a microprocessor over current protective trip system. Standards The UL489/CSA 22.2 version of the T8 also carries an IEC-60947-2 rating. Versions To meet all application requirements the T8 is available in the following versions: C = Adjustable LSI PR232/P-T8 Dip switch settings D = Molded Case Switch E = Adjustable LSIG PR331/P Dip switch settings P = Adjustable LI PR332/P LCD Display R = Adjustable LSI PR332/P LCD Display S = Adjustable LSIG PR332/P LCD Display Rc = Residual Current (IEC, 3 pole, under 3200A only) UL489/CSA C22.2 Interrupting capacity (kA RMS) Voltage V 240VAC 480VAC 600VAC DC 125 125 100 -- IEC 60947-2 Interrupting capacity (kA RMS) Voltage Trip functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault 230VAC 415VAC 440VAC 690VAC DC V 130 130 100 80 -- Performance levels Each version is also available at the following maximum fault interrupting level: V = Very high Number of poles The T8 is available in three and four pole versions. 17 17.56 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T8 Catalog number explanation T 8 V Locking provisions: X = None; A = Keylock B = Button guard; C = Padlock provision; D = A+B; E = A+C T = Heavy duty padlock; 9 = Extra heavy duty padlock Accessories X = None; A = Mechanical counter; B = Bell Alarm C = Bell Alarm w/remote reset, 24..30 VAC/DC D = Bell Alarm w/remote reset 110..130 VAC/DC E = Bell Alarm w/remote reset 220..240 VAC/DC F = A+B; G = A+C; H = A+D; J = A+E Undervoltage 0 = None A = 24 VDC; B = 30 VAC/DC C = 48 VAC/DC; D = 60 VAC/DC E = 110..120 VAC/DC; F = 125..127 VAC/DC G = 220..240 VAC/DC; H = 250 VAC/DC J = 380..400 VAC; K = 440 VAC Second shunt trip: L = 24 VDC; M = 30 VAC/DC N = 48 VAC/DC; P = 60 VAC/DC Q = 110..120 VAC/DC; R = 125..127 VAC/DC S = 220..240 VAC/DC; T = 250 VAC/DC U = 380..400 VAC; V = 440..480 VAC Shunt trip 0 = None A = 24 VDC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110..120 VAC/DC F = 120..127 VAC/DC; G = 220..240 VAC/DC; H = 240..250 VAC/DC; J = 380...400 VAC; K = 440 VAC Spring charging motor: 0 = None A = 24..30 VAC/DC; B = 48..60 VAC/DC; C = 100..130 VAC/DC; D = 220..250 VAC/DC Contacts: 0 = None A = 4 aux contacts; (supplied as standard for breakers with PR332 trip units) B = 4 aux contacts digital (24V) D = UV energ NO; E = UV energ NC; F = A+D; G = A+E; H = B+D; J = B+E Closing Coil: 0 = None A = 24 VDC; B = 30 VAC/DC; C = 48 VAC/DC; D = 60 VAC/DC; E = 110..120 VAC/DC; F = 120..127 VAC/DC; G = 220..240 AC/DC; H = 240..250 VAC/DC; J = 380..400 VAC; K = 440VAC 17 Trip Unit Accessories: PR332/P ONLY 0 = None B = Voltage measuring module; C = Modbus module Trip Unit: C = PR331/P-T8-LSI; D = Non-Automatic (MCS); E = PR331/P-LSIG; P = PR332/P-LI; R = PR332/P-LSI; S = PR332/P-LSIG; H = PR332/P-LSIRc (IEC) Rating Plug: D = 1000; E = 1200; F = 1600; G = 2000; H = 2500; J = 3000, 3200; 0 = Non-Automatic (MCS) Frame Amp Rating: C3 = 1600 (3P UL only); D3 = 2000 (3P); E3 = 2500 (3P); F3 = 3000 UL/3200 IEC (3P) C4 = 1600 (4P UL only); D4 = 2000 (4P); E4 = 2500 (4P); F4 = 3000 UL/3200 IEC (4P) Version: B = UL Fixed; Q = UL Fixed 100% Rated; F = IEC Fixed; 0 = Fixed Non-Automatic (MCS) Breaking capacity: V = Very High; L (IEC only. Call factory for IEC breaker pricing.) Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.57 1SXU000023C0202 Rev. A ax Tm CBs C M T8 1600/2000/2500/3000A 600V - Three Pole Electronic (AC Only) 1600A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VBC3FC000000XX T8VBC3FE000000XX T8VBC3FP00A000XX 1 T8V IC at 480VAC kA 125 Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VBE3HC000000XX T8VBE3HE000000XX T8VBE3HP00A000XX 1 PR332 LSI (LCD) T8VBC3FR00A000XX 1 PR332 LSI (LCD) T8VBE3HR00A000XX 1 PR332 LSIG (LCD) T8VBC3FS00A000XX 1 PR332 LSIG (LCD) T8VBE3HS00A000XX 1 2000A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker 2500A Frame, electronic trip unit (AC only) standard horizontal terminals Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VBD3GC000000XX T8VBD3GE000000XX T8VBD3GP00A000XX 1 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VBF3JC000000XX T8VBF3JE000000XX T8VBF3JP00A000XX 1 PR332 LSI (LCD) T8VBD3GR00A000XX 1 PR332 LSI (LCD) T8VBF3JR00A000XX 1 PR332 LSIG (LCD) T8VBD3GS00A000XX 1 PR332 LSIG (LCD) T8VBF3JS00A000XX 1 17 1 Includes 4 open/closed auxillary contacts as standard 17.58 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T8 1600/2000/2500/3000A 600V - Three Pole Electronic (AC Only) 100% Rated 1600A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VQC3FC000000XX T8VQC3FE000000XX T8VQC3FP00A000XX 1 T8V Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VQE3HC000000XX T8VQE3HE000000XX T8VQE3HP00A000XX 1 T8VQC3FR00A000XX 1 PR332 LSI (LCD) T8VQE3HR00A000XX 1 PR332 LSIG (LCD) T8VQC3FS00A000XX 1 PR332 LSIG (LCD) T8VQE3HS00A000XX 1 IC at 480VAC kA 125 2500A Frame, electronic trip unit (AC only) standard with vertical terminals - Required PR332 LSI (LCD) 2000A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T M max CC Bs Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VQD3GC000000XX T8VQD3GE000000XX T8VQD3GP00A000XX 1 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 3 pole, 600V Catalog number T8VQF3JC000000XX T8VQF3JE000000XX T8VQF3JP00A000XX 1 PR332 LSI (LCD) T8VQD3GP00A000XX 1 PR332 LSI (LCD) T8VQF3JR00A000XX 1 PR332 LSIG (LCD) T8VQD3GR00A000XX 1 PR332 LSIG (LCD) T8VQF3JS00A000XX 1 17 1 Includes 4 open/closed auxillary contacts as standard Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.59 1SXU000023C0202 Rev. A ax Tm CBs C M T8 1600/2000/2500/3000A 600V-- Four pole Electronic (AC Only) 1600A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VBC4FC000000XX T8VBC4FE000000XX T8VBC4FP00A000XX 1 T8V IC at 480VAC kA 125 Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VBE4HC000000XX T8VBE4HE000000XX T8VBE4HP00A000XX 1 PR332 LSI (LCD) T8VBC4FR00A000XX 1 PR332 LSI (LCD) T8VBE4HR00A000XX 1 PR332 LSIG (LCD) T8VBC4FS00A000XX 1 PR332 LSIG (LCD) T8VBE4HS00A000XX 1 2000A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker 2500A Frame, electronic trip unit (AC only) standard horizontal terminals Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VBD4GC000000XX T8VBD4GE000000XX T8VBD4GP00A000XX 1 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VBF4JC000000XX T8VBF4JE000000XX T8VBF4JP00A000XX 1 PR332 LSI (LCD) T8VBD4GR00A000XX 1 PR332 LSI (LCD) T8VBF4JR00A000XX 1 PR332 LSIG (LCD) T8VBD4GS00A000XX 1 PR332 LSIG (LCD) T8VBF4JS00A000XX 1 17 1 Includes 4 open/closed auxillary contacts as standard 17.60 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T8 1600/2000/2500/3000A 600V--Four pole Electronic (AC Only) 100% Rated 1600A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VQC4FC000000XX T8VQC4FE000000XX T8VQC4FP00A000XX 1 T8V Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VQE4HC000000XX T8VQE4HE000000XX T8VQE4HP00A000XX 1 T8VQC4FR00A000XX 1 PR332 LSI (LCD) T8VQE4HR00A000XX 1 PR332 LSIG (LCD) T8VQC4FS00A000XX 1 PR332 LSIG (LCD) T8VQE4HS00A000XX 1 IC at 480VAC kA 125 2500A Frame, electronic trip unit (AC only) standard vertical terminals - Required PR332 LSI (LCD) 2000A Frame, electronic trip unit (AC only) standard horizontal terminals Breaker T M max CC Bs Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VQD4GC000000XX T8VQD4GE000000XX T8VQD4GP00A000XX 1 3000A Frame, electronic trip unit (AC only) standard with vertical terminals - Required Breaker T8V IC at 480VAC kA 125 Trip Unit PR232 LSI (Dip Switch) PR331 LSIG (Dip Switch) PR332 LI (LCD) 4 pole, 600V Catalog number T8VQF4JC000000XX T8VQF4JE000000XX T8VQF4JP00A000XX 1 PR332 LSI (LCD) T8VQC4GR00A000XX 1 PR332 LSI (LCD) T8VQF4JR00A000XX 1 PR332 LSIG (LCD) T8VQD4GS00A000XX 1 PR332 LSIG (LCD) T8VQF4JS00A000XX 1 17 1 Includes 4 open/closed auxillary contacts as standard Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.61 1SXU000023C0202 Rev. A ax Tm CBs C M T8 2000/2500/3000A 600V Molded Case Switch T8V-D Rated Voltage AC DC Magnetic Overide 600VAC -- 40000 2000A Frame, standard horizontal terminals Breaker T8V-D 2500A Frame, standard horizontal terminals Breaker T8V-D 3 pole, 600V Catalog number T8V0D30D000000XX 3 pole, 600V Catalog number T8V0E30D000000XX 3000A Frame, standard with vertical terminals - Required Breaker T8V-D 3 pole, 600V Catalog number T8V0F30D000000XX 17 17.62 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T8 Accessories, electrical UL Rating plugs Catalog number 1000A Rating plug 1200A Rating plug 1600A Rating plug 2000A Rating plug 2500A Rating plug 3000A Rating plug T8 Field/factory installation Catalog number Accessories for trip units Communication module (Modbus (RTU) External wireless communication module Power supply unit T8 Voltage module, 3 pole 3 PR330/D-M 2 BT030 PR030/B PR330/V-T83 Voltage module, 4 pole 3 PR330/V-T84 Current sensor for external neutral T8 Current sensor for external neutral 1000A-3000A 440 VAC 380...400VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VDC T8 4 open/closed PR232-T8/PR331 4 open/closed PR332 1 4 open/closed 24V PR232-T8/PR331 4 open/closed 24V PR332 T8 KT8A4 Allows visual signaling (mechanical) and remote signaling (electrical) of circuit breaker opening by overcurrent release Bell alarm with remote reset command Remote setting of circuit breaker after opening by overcurrent release 220-240 VAC/DC Remote setting of circuit breaker after opening by overcurrent release 110-130 VAC/DC Remote setting of circuit breaker after opening by overcurrent release 24-30 VAC/DC Contact signaling undervoltage de-energized T8 NC UV signaling contact NO UV signaling contact KT8A4 KT8A4-PR332 KT8A4D KT8A4D-PR332 DE6TBA Field/factory installation Catalog number 17 DE6TBAR4 DE6TBAR5 DE6TBAR9 Field/factory installation Catalog number KE6UE01 KE6UE10 Field/factory installation Catalog number Spring charging motor T8 KE6C1 KE6C2 KE6C3 KE6C4 KE6C5 KE6C6 KE6C7 KE6C8 KE6C9 KE6C0 Field/factory installation Catalog number Bell alarm T8 KT8NCT Field/factory installation Catalog number Auxiliary contacts T8 Field installation Catalog number Field/factory installation Catalog number Closing coil KE6C* KT81000RP KT81200RP KT81600RP KT82000RP KT82500RP KT83000RP 24...30 VAC/DC 48...60 VAC/DC 100...130 VAC/DC 220...250 VAC/DC KE6M9 KE6M7 KE6M5 KE6M3 KE6M* 1 Included as standard on breakers ordered with PR332 trip unit 2 Discount schedule SAT (T0) 3 Factory install only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.63 1SXU000023C0202 Rev. A ax Tm CBs C M T8 Accessories, electrical Field/factory installation Catalog number Shunt trip T8 KE6S* 440 VAC 380...400 VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VDC Field/factory installation Catalog number Second shunt trip 1 T8 440 VAC 380...400 VAC 240...250 VAC/DC 220...240 VAC/DC 120...127 VAC/DC 110...120 VAC/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VDC KE6U* KE6S1-2 KE6S2-2 KE6S3-2 KE6S4-2 KE6S5-2 KE6S6-2 KE6S7-2 KE6S8-2 KE6S9-2 KE6S0-2 Field/factory installation Catalog number Undervoltage T8 KE6S1 KE6S2 KE6S3 KE6S4 KE6S5 KE6S6 KE6S7 KE6S8 KE6S9 KE6S0 440 VAC 380...400 VAC 240...250 VAC 220...240 VAC/DC 120...127 VAC/DC 110...120 VACV/DC 60 VAC/DC 48 VAC/DC 30 VAC/DC 24 VDC KE6U1 KE6U2 KE6U3 KE6U4 KE6U5 KE6U6 KE6U7 KE6U8 KE6U9 KE6U0 17 1 May be used in place undervoltage. 17.64 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs T8 Accessories, mechanical Field/factory installation Catalog number Key lock in open position T8 KT8KL2 KT8KL3 KT8KL4 KT8KL5 KT8KL1 Key lock n. 20005 1 Key lock n. 20006 Key lock n. 20007 Key lock n. 20008 Key lock different keys Field/factory installation Catalog number Padlocking button cover T8 3-4mm locks (padlocks not supplied) HD padlock device Extra HD padlock device KE6PD1 KE6PDHD1 KE6PDHD2 Field/factory installation Catalog number Button guard T8 Protective cover for opening and closing pushbuttons KE6PG KE6PG Field/factory installation Catalog number Mechanical operation counter T8 Indicates the number of mechanical operations Field installation Catalog number Phase barriers-top terminals only T8 Low 100mm 2 pcs (3P) Low 100mm 3 pcs (4P) High 200mm 2 pcs (3P) High 200mm 4 pcs (4P) KT8PBL-3 KT8PBL-4 KT8PBH-3 KT8PBH-4 Field installation Catalog number IP54 door protection T8 Protective cover KE6DC Field installation Catalog number Vertical terminals T8 Rear Vertical Terminals (2) Cable terminals T8 KE6MC Mechanical Lugs (set of 3) Set of six Set of eight KT82500VR-6 KT82500VR-8 Wire size Field installation Catalog number 1/0-750 kcmil (4) 1/0-750 kcmil (6) K8TL K8TM 17 1 Key lock number when factory installed is 20005. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.65 1SXU000023C0202 Rev. A ax Tm CBs C M T8 Technical data Absorbed power on inrush Spring charging motor Shunt trip, Second shunt trip, closing coil Shunt trip, Second shunt trip, closing coil Voltage AC DC 24 VDC 30 VAC/DC 48 VAC/DC 60 VAC/DC 110...120 VAC/DC 120...127 VAC/DC 220...240 VAC/DC 380...400 VAC 440 VAC Opening time shunt trip - Second shunt trip (ms) Closing time closing coil (ms) -- 200 200 200 200 200 200 200 200 60 80 200 200 200 200 200 200 200 -- -- 60 80 Rated Voltage Operating voltage (%Un) Power consumption on inrush Inrush time (s) Charging time (s) AC DC 24...30 48...60 100...130 220...250 85-110 500 VA 0.2 4-5 24...30 48...60 100...130 220...250 85...110 500 W 0.2 4-5 17 17.66 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage UL489B Photovoltaic circuit breakers Tmax Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Tmax UL489B Photovoltaic circuit breakers Introduction Weights Thanks to its experience with Tmax UL, ABB is proposing a complete range of products in accordance to UL489B, a new standard, whose requirements cover molded case circuit breakers and molded case switches rated up to 1000V DC, intended for use with photovoltaic systems. A complete range of MCCB and MCS is available up to 1000A for use at 1000V DC, complete with jumpers for connection of poles in series. Standards T1 - 3.2 lbs. T4 - 6.18 lbs. T5 - 8.55 lbs. T6 - 20.9 lbs. T7 - 24.25 lbs. Accessories UL489B Dimensions T M max CC Bs Standard Tmax accessories are able to work with all UL 489B units. Jumpers come standard with all breakers in either all poles in series or 2+1 or 2+2. Breakers without lug kits come with terminals to connect to Busbar poles in series for installation options. All PV breakers are the same size as their standard UL/IEC counterparts. 17 17.67 1SXU000023C0202 Rev. A ax Tm CBs C M General information Catalog number explanation Catalog number explanation P ___ ___ ___ ___ ___ T ___ ___ ___ Frame size Number of poles Blank = 3 pole Photovoltaic designation Connection L = With lugs W = Bus connection Jumpers A = Jumpers with all poles in series B = Jumpers with 2+2 or 2+1 configuration Amperage Device D = Molded case switch T = Thermal-mag circuit breaker 17 17.68 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Tmax UL489B Molded case circuit breakers and switches T4 - 200A Frame TMA, Thermal magnetic adjustable IC at 1000VDC Rating Lugs 3kA 40A Yes 3kA 50A Yes 3kA 80A Yes 3kA 100A Yes 3kA 125A Yes 3kA 150A Yes 3kA 200A Yes Catalog number Poles in Series 2+1 3 2+1 3 2+1 3 2+1 3 2+1 3 2+1 3 2+1 3 T4PB040TL T4PA040TL T4PB050TL T4PA050TL T4PB080TL T4PA080TL T4PB100TL T4PA100TL T4PB125TL T4PA125TL T4PB150TL T4PA150TL T4PB200TL T4PA200TL T5 - 400A Frame TMA, Thermal magnetic adjustable IC at 1000VDC Rating Lugs 5kA 400A Yes 5kA 400A No Catalog number Poles in Series 2+1 3 2+1 3 T5PB400TL T5PA400TL T5PB400TW T5PA400TW T1-D 100A Molded case switch Rating Lugs Poles in Series Catalog number 100A Yes 2+2 4 T1PB100DL-4 T1PA100DL-4 Catalog number T4-D 200A Molded case switch Rating Lugs Poles in Series 200A Yes 2+1 3 T4PB200DL T4PA200DL T5-D 400A Molded case switch Rating Lugs 400A Yes 400A No Poles in Series 2+1 3 2+1 3 Catalog number T5PB400DL T5PA400DL T5PB400DW T5PA400DW T6-D 800A Frame molded case switch Rating Lugs 600A Yes 800A No Poles in Series Catalog number 2+2 4 2+2 4 T6PB600DL-4 T6PA600DL-4 T6PB800DW-4 T6PA800DW-4 T6 - 800A Frame TMA, Thermal magnetic adjustable IC at 1000VDC Rating Lugs 10kA 600A Yes 10kA 800A No Poles in Series Catalog number 2+2 4 2+2 4 T6PB600TL-4 T6PA600TL-4 T6PB800TW-4 T6PA800TW-4 T7-D 1000A Molded case switch Rating Lugs Poles in Series Catalog number 1000A Yes 2+2 4 T7MPB1000DL-4 T7MPA1000DL-4 NOTE: All poles in series is for use in grounded systems. 2+1 or 2+2 configurations are for ungrounded systems. 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.69 1SXU000023C0202 Rev. A ax Tm CBs C M Tmax UL489B Jumper kit accessories T1-D Description JUMPER KIT T1PV 100A 4P 2+2PS LUG UL JUMPER KIT T1PV 100A 4P 4PS LUG UL Rating Poles in Series Catalog number 100A 2+2 4 KT1PB100-L KT1PA100-L Rating Poles in Series Catalog number 2+1 3 2+1 3 KT4PB100-L KT4PA100-L KT4PB200-L KT4PA200-L Rating Poles in Series Catalog number 400A 2+1 3 2+1 3 KT5PB400-L KT5PA400-L KT5PB400-W KT5PA400-W Rating Poles in Series Catalog number 2+2 4 2+2 4 KT6PB600-L KT6PA600-L KT6PB800-W KT6PA800-W Poles in Series Catalog number T4-D Description JUMPER KIT T4PV 100A 3P 2+1PS LUG UL JUMPER KIT T4PV 100A 3P 3PS LUG UL JUMPER KIT T4PV 200A 3P 2+1PS LUG UL JUMPER KIT T4PV 200A 3P 3PS LUG UL 100A 200A T5-D Description JUMPER KIT T5PV 400A 3P 2+1PS LUG UL JUMPER KIT T5PV 400A 3P 3PS LUG UL JUMPER KIT T5PV 400A 3P 2+1PS BUS UL JUMPER KIT T5PV 400A 3P 3PS BUS UL T6-D Description JUMPER KIT T6PV 600A 4P 2+2PS LUG UL JUMPER KIT T6PV 600A 4P 4PS LUG UL JUMPER KIT T6PV 800A 4P 2+2PS BUS UL JUMPER KIT T6PV 800A 4P 4PS BUS UL 600A 800A T7-D Description Rating JUMPER KIT T7PV 1000A 4P 2+2PS LUG UL 1000A JUMPER KIT T7PV 1000A 4P 4PS LUG UL NOTE: See pages 17.71-17.83 for additional electrical/mechanical accessories 2+2 4 KT7PB1000-L KT7PA1000-L 17 17.70 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Electrical T1 - T7 Shunt trips -(Standard) 1 For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. T1-T6 mounts in the left hand cavity cannot be used with UVR on 2-3P breakers Factory Installation 1 Field Installation Voltage Catalog number suffix Catalog number 480 - 500VAC 220-250VAC/DC 380 - 440VAC 110 - 125VAC/DC 48 - 60VAC/DC 24 - 30VAC/DC 12VDC 480VAC/250VDC 240 VAC 120VAC/125VDC 48VDC 24VAC/VDC 12VDC 480-500VAC 220/250VAC/DC 380-440VAC 110-125VAC/DC 48-60VAC/DC 24VAC/DC 12VDC 415-440VAC 380-400VAC 240-250VAC/DC 220-240VAC/DC 120-127VAC/DC 110-120VAC/DC 60VAC/DC 48VAC/DC 30VAC/DC 24VAC/DC S1 S2 S3 S4 S7 S8 S9 S1 S2 S4 S7 S8 S9 S1 S2 S3 S4 S7 S8 S9 S1 S2 S3 S4 S5 S6 S7 S8 S9 S0 KT3S1 KT3S2 KT3S3 KT3S4 KT3S7 KT3S8 KT3S9 KTS3S1 KTS3S2 KTS3S4 KTS3S7 KTS3S8 KTS3S9 KT5S1 KT5S2 KT5S3 KT5S4 KT5S7 KT5S8 KT5S9 KT7XS1 KT7XS2 KT7XS3 KT7XS4 KT7XS5 KT7XS6 KT7XS7 KT7XS8 KT7XS9 KT7XS0 Frame Size T1-T3 KT3S4 Ts3 T4, T5, T6 3 T1 with KT3S4 T7 Shunt trip connector (REQUIRED for Ts3) 2 T7 X1 Shunt trip - UVR Ts3 Field Kit Fixed Mount 2 Included when shunt trip factory installed KTS3C-SU Draw-out 2 Included when shunt trip factory installed KTS3C-SUP Shunt trips (Permanent Supply) 1 For remote opening of circuit breaker. Guaranteed operation for a voltage of between 75-110% of the rated power supply voltage. These shunt trips have much lower power consumption. Frame Size Ts3 T4, T5, T6 3 Factory Installation 1 Field Installation Voltage Catalog number suffix Catalog number 24VDC 120VAC 24-30VDC 110/120/VAC SA SB SA SB KTS3SA KTS3SB KT5SA KT5SB Shunt trip connector (REQUIRED for Ts3) 2 Ts3 Fixed Mount 2 Draw-out 2 17 Field Kit Included when shunt trip factory installed Included when shunt trip factory installed KTS3C-SU KTS3C-SUP 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. 2 Must be ordered separately for field installation. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.71 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Electrical T1 - T7 Undervoltage release - UVR Will trip circuit breaker when connected voltage drops to 35-70% of the undervoltage release voltage rating. Will allow circuit breaker to close when voltage is approximately 85% of the rated voltage. T1-T6 mounts in the left hand cavity cannot be used with shunt trip on 2-3P breakers Frame Size T1-T3 KT3U2 Ts3 T4, T5, T6 T7 X1 Shunt trip - UVR T7 Factory Installation 1 Field Installation Voltage Catalog number suffix Catalog number 480 - 500VAC 220-250VAC/DC 380 - 440VAC 110 - 125VAC/DC 60VAC/DC 48VAC/DC 24 - 30VAC/DC 480VAC 240VAC 24VAC 120VAC 250VDC 125VDC 48VDC 24VDC 480-500VAC 220/250VAC/DC 380-440VAC 110-125VAC/DC 60VAC/DC 48VAC/DC 24VAC/DC 415-440VAC 380-400VAC 240-250VAC/DC 220-240VAC/DC 120-127VAC/DC 110-120VAC/DC 60VAC/DC 48VAC/DC 30VAC/DC 24VAC/DC U1 U2 U3 U4 U5 U7 U8 U1 U2 U3 U4 U5 U6 U7 U8 U1 U2 U3 U4 U5 U7 U8 U1 U2 U3 U4 U5 U6 U7 U8 U9 U0 KT3U1 KT3U2 KT3U3 KT3U4 KT3U5 KT3U7 KT3U8 KTS3U1 KTS3U2 KTS3U3 KTS3U4 KTS3U5 KTS3U6 KTS3U7 KTS3U8 KT5U1 KT5U2 KT5U3 KT5U4 KT5U5 KT5U7 KT5U8 KT7XU1 KT7XU2 KT7XU3 KT7XU4 KT7XU5 KT7XU6 KT7XU7 KT7XU8 KT7XU9 KT7XU0 Undervoltage trip connector (REQUIRED for Ts3) 2 Field Kit Included when Fixed Mount 2 Ts3 Plug-In/Draw-out 2 17 under voltage factory installed Included when under voltage factory installed KTS3C-SU KTS3C-SUP 1 For factory installation add suffix given to end of circuit breaker catalog number per accessory format. 2 Must be ordered separately for field installation. 17.72 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Electrical T1 - T7 Auxiliary contacts - AUX 1 Auxiliary contacts are for indication of the circuit breaker open-closed. Bell alarm contacts (BA) can be used to indicate circuit breaker tripped. Frame Size T1-T3 2 T2 Ts3 T4, T5, T6 4 T1 with K3TAS T7 1 Form C + 1BA 3 Form C + 1BA 3 Form C + 1BA 24VDC T2 PR221DS 1 Form C + 1BA 2 Form C 1 Form C+ 1 BA 1 Form C + 1BA 250VAC/VDC 2 Form C 400VAC/250VDC 3 Form C + 1BA 250VAC/VDC 3 Form C + 1BA 24VDC 1 Form C + 1BA 400VAC/250VDC 2 Form C 400VAC/250VDC 1 Form C + 1BA 24VDC 2 Form C 24VDC 3 Form C + 1BA 400VAC/250VDC 3 Form C + 1BA 24VDC Factory Installation 1 Catalog number A A3 A3AU A A BA A A2 A3 A3AU A A2 AAU A2AU A3 A3AU KT3AS KT3AS3 KT3AS3-AU KT2AS-E KTS3AS KTS3BA KT5AS KT5AS2-B KT5AS3 KT5AS3-AU KT7AS KT7XAS2 KT7AS-AU KT7XAS2-AU KT7AS3 KT7AS3-AU Auxiliary contact connector (REQUIRED for Ts3) 3 Ts3 Field Installation Catalog number suffix Field Kit Fixed Mount 3 Included KTS3C-AB Plug-In /Drawout 3 Included KTS3C-ABP KTS3AS 17 1 For factory installation add suffix to end of breaker part number per accessory format . 2 Not compatible for T2 with PR221DS trip unit. 3 Must be ordered separately for field installation. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.73 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Motor operators T1 - T7 Electrical operators Allows remote opening and closing of circuit breaker Frame size Voltage Catalog number Solenoid operator T1-T3 48 - 60VDC 110 - 250VAC/DC KT3M1 KT3M2 240VAC/250VDC 120VAC/125VDC 48VDC 24VDC KTS3M2 KTS3M4 KTS3M7 KTS3M8 Direct action motor operator Ts3 KT3M1 Motor operator connector (REQUIRED for Ts3) 1 Ts3 Fixed Mount 1 Plug-In / Draw-out 1 KTS3C-M KTS3C-MP Stored energy motor operator T4, T5 220-250VAC/DC 110--125-VAC/DC 48-60VDC 24VDC KT5M2 KT5M4 KT5M7 KT5M8 Contact for remote/manual operation (stored energy operator) T4, T5, T6 - KT5MA 220-250VAC/DC 110--125-VAC/DC 48-60VDC 24VDC 380VAC KT6M2 KT6M4 KT6M7 KT6M8 KT6M3 Stored energy motor operator T6 KT5M2 17 KTS3M2 1 Must be ordered separately for field installation. 17.74 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Trip units T4 - T7 Frame Size Rating plug Catalog number 400A Rating plug 600A Rating plug 800 Rating plug 1000A Rating plug 1200 Rating plug KT7X0400RP KT7X0600RP KT7X0800RP KT7X1000RP KT7X1200RP Rating plugs (UL) T7 Modules for T7 PR332 trip units Voltage module 2 Communication module (Modbus RTU) T7 PR330/VT7 PR330/D-M External units Test and configuration unit 3 Trip coil test-all Tmax electronic trip unit except PR33* External Bluetooth communication module 1 Includes diagnostic software for Modbus / Bluetooth networks Battery power supply unit 1 Not suitable for UL applications. T7 - Allows remote opening when used with PR330/D-M and shunt trip T7M - Allows remote opening and closing when used with PR330//D-M. shunt trip and closing coil PR010/T K7TUT BT030 PR030/B Actuator module (IEC) T7 Actuator module 2 PR330/R-T7 Neutral current transformers (required for 4 wire ground fault systems) T4 T5 T6 100A 150A 250A 300A 400A 600A 800A KT4NCT-100 KT4NCT-150 KT4NCT-250 KT5NCT-300 KT5NCT-400 KT6NCT-600 KT6NCT-800 Current sensor for external neutral T7 400 - 1200A KT7NCT 17 1 Always supplied with PR332/P trip unit. 3 Factory installed only. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.75 1SXU000023C0202 Rev. A ax Tm CBs C M Technical data Shunt trips, Undervoltages T1 - T7 Standard shunt trip Voltage 12 VDC 24 VAC/DC 24...30 VAC/DC 30 VAC/DC 48 VAC/DC 48...60 VAC/DC 60 VAC/DC 100...120 VAC/DC 120...127 VAC/DC 110...127 VAC 110...125 VDC 220...240 VAC/DC 220...240 VAC 220...250 VDC 240...250 VAC/DC 380...400 VAC 380...440 VAC 415...440 VAC 480 VAC 480...525 VAC Opening Time (ms) T1,T2,T3 AC (VA) DC (W) 50 60 50 50 55 55 15 50 50 60 50 50 15 Inrush Power Consumption Ts3 T4,T5,T6 AC (VA) DC (W) AC (VA) DC (W) 100 - 120 100 or 4 1 120 100 or 4 1 120 100 120 100 15 15 150 150 150 150 150 150 15 150 150 150 150 150 15 T7 AC (VA) DC (W) 300 300 300 300 300 300 300 300 300 300 20 300 300 300 300 300 300 300 300 20 Permanent supply shunt trip Voltage 24 VAC/DC 100...120 VAC T4,T5,T6 AC (VA) DC (W) 4 4 4 - Undervoltage Voltage 17 24 VAC/DC 24...30 VAC/DC 30 VAC/DC 48 VAC/DC 60 VAV/DC 110...120 VAC/DC 120...127 VAC/DC 110...127 VAC 110...125 VDC 220...240 VAC/DC 220...240 VAC 220...250 VDC 220...250 VAC 240...250 VAC/DC 380...400 VAC 380...440 VAC 415 - 440 VAC 480...525 VAC 480 VAC Opening Time (ms) T1,T2,T3 AC (VA) DC (W) 1.5 1 1 2 2.5 3 4 15 1.5 1 1 2 2.5 15 Power consumption during permanent operation Ts3 T4, T5, T6 AC (VA) DC (W) AC (VA) DC (W) 6 6 6 6 6 18 3 3 3 18 6 6 6 6 6 6 6 25 3 3 3 3 3 25 T7 AC (VA) DC (W) 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 25 3.5 3.5 3.5 3.5 3.5 3.5 25 1 Shunt trip permanent supply 17.76 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Technical data Electrical operators T1 - T6 Electrical operator, T1-T3 Rated Voltage AC DC 48...60 110...250 110...250 85...110% Un 1800 (VA) 1000 (W) < 100 (mW) < 0.1 < 0.1 Operating Voltage Inrush power absorption during operation Power on stand by opening (s) Time closing (s) Minimum control impulse time on >100 opening and closing (ms) This unit is permanently supplied on stand by, a control is applied by means of external contact in a low power circuit. Contact characteristics: Voltage AC/DC=24V Current 50 mA Operating Voltage Inrush power absorption Service power absorption Time constant (ms) opening (s) Duration closing (s) Minimum duration of the opening and closing command impulse (ms) Voltage Operating Voltage Inrush power consumption In service power consumption opening (s) Duration closing (s) resetting (s) Minimum duration of the opening and closing command impulse (ms) AC DC 24 48...60 110...125 110...125 220-250 220-250 380 85...110% 300VA 300W 150VA 150W 1.5 < 0.1 3 100 Electrical operator, T6 Electrical operator, Ts3 Rated Voltage Electrical operator, T4-T5 AC DC 24 48...60 120 125 240 250 440 85...110 % Un 500 (VA) 500 (W) 350 (VA) 350 (W) 18 0.1 0.1 150 Voltage Operating Voltage Inrush power consumption In service power consumption opening (s) Duration closing (s) resetting (s) Minimum duration of the opening and closing command impulse (ms) AC DC 24 48...60 110-125 110-125 220-250 220-250 380 85...110% 400VA 400W 150VA 150W 3 < 0.1 5 100 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.77 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Mechanical T1 - T7 Standard cable terminal Frame T1 T2 Catalog number (set of 4) 14 AWG-1/0 14 AWG-1/0 14 AWG - 1/0 4 AWG - 300 kcmil 14-2 14-1/0 2-4/0 4-300 kcmil 14 AWG-1/0 6 AWG-350 kcmil 250 kcmil-500 kcmil Integral KT2100-3 KT3100-3 KT3225-3 K3TA K4TB K4TC K4TD KT4100-3 KT4250-3 KT5300-3 Integral KT2100-4 KT3100-4 KT3225-4 K3TA-4 K4TB-4 K4TC-4 K4TD-4 KT4100-4 KT4250-4 KT5300-4 T5 13 (2) 3/0-250 kcmil KT5400-3 KT5400-4 T5 2 T6 T6 1 (2) 3/0-500 kcmil (2) 250-500 kcmil (3) 2/0-400 kcmil KT5600-3 K6TH K6TJ -- K6TH-4 K6TJ-4 T7 1 (4) 4/0-500 kcmil KT7X1200-3 KT7X1200-4 T3 Ts3 KT3100-3 Catalog number (set of 3) Wire Size T4 T5 3 Standard cable lug kits with power control taps Frame T3 Ts3 KT1HTC-3 T4 T5 3 Catalog number (set of 3) Wire Size Catalog number (set of 4) 14 AWG - 1/0 4 AWG - 300 kcmil 14 AWG-1/0 2 AWG-4/0 4 AWG-300 kcmil 14 AWG-1/0 6 AWG-350 kcmil 250 kcmil-500 kcmil KT3100-3C KT3225-3C K4TBC K4TCC K4TDC KT4100-3C KT4250-3C KT5300-3C KT3100-4C KT3225-4C K4TBC-4 K4TCC-4 K4TDC-4 KT4100-4C KT4250-4C KT5300-4C (2) 3/0-250 kcmil (2) 250-500 kcmil (3) 2/0-400 kcmil KT5400-3C K6THC K6TJC KT5400-4C K6THC-4 K6TJC-4 T5 13 T6 T6 1 Terminal covers for fixed breakers - Low profile-kit includes two pieces Frame T1 T2 T3 Ts3 T4 T5 T6 T7 17 KT4LTC-3 Catalog number (3 pole) Catalog number (4 pole) KT1LTC-3 KT2LTC-3 KT3LTC-3 KTS3LTC-3 KT4LTC-3 KT5LTC-3 KT6LTC-3 KT7XLTC-3 KT1LTC-4 KT2LTC-4 KT3LTC-4 KTS3LTC-4 KT4LTC-4 KT5LTC-4 KT6LTC-4 KT7XLTC-4 Terminal covers for fixed breakers - High profile-kit includes two pieces Frame T1 T2 T3 Ts3 T4 T5 T6 T7 Catalog number (3 pole ) Catalog number (4 pole) KT1HTC-3 KT2HTC-3 KT3HTC-3 KTS3HTC-3 KT4HTC-3 KT5HTC-3 KT6HTC-3 KT7XHTC-3 KT1HTC-4 KT2HTC-4 KT3HTC-4 KTS3HTC-4 KT4HTC-4 KT5HTC-4 KT6HTC-4 KT7XHTC-4 1 Comes standard with high profile terminal covers. 2 Uses front extended spreaded terminals... refer to technical catalog. 3 Not suitable for use on T5 600A. 17.78 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Mechanical T1 - T7 Phase barriers - Low profile 100mm-3.93 in Frame T1-T3 T4-T5 T6 T7 4 pcs (3p) KT3PBL-3 KT5PBL-3 KT6PBL-3 KT7PBL-3 6 pcs (4p) KT3PBL-4 KT5PBL-4 KT6PBL-4 KT7PBL-4 Phase barriers - High profile 200mm-7.87 in KT2EF-3 Frame 4 pcs (3p) 6 pcs (4p) T1-T3 T4-T5 T7 KT3PBH-3 KT5PBH-3 KT7PBH-3 KT3PBH-4 KT5PBH-4 KT7PBH-4 Saddle terminals for Copper Cables - IEC Frame Catalog number ( Set of 3 ) Catalog number (Set of 4) T2 T3 Ts3 T4 T5 KT2100S-3 KT3225S-3 K4TES KT4250S-3 KT5300S-3 KT2100S-4 KT3225S-4 K4TES-4 KT4250S-4 KT5300S-4 Extended front terminals KT4EF-_ Frame Catalog number (set of 3) Catalog number (set of 4) T1 T2 T3 Ts3 T4 T5 KT1EF-3 KT2EF-3 KT3EF-3 KTS3EF-3 KT4EF-3 KT5EF-3 KT1EF-4 KT2EF-4 KT3EF-4 KTS3EF-4 KT4EF-4 KT5EF-4 Frame Catalog number (set of 3) Catalog number (set of 4) T2 T3 T4 T5 T6 T7 KT2R-3 KT3R-3 KT4R-3 KT5R-3 KT6R-3 KT7R-3 KT2R-4 KT3R-4 KT4R-4 KT5R-4 KT6R-4 KT7R-4 Rear terminals 1 KT2R-3 Distribution cable lug kit 2 Frame T3 Ts3 T4 T5 Wire Size (6) #14-6 (6) #14-6 (6) #14-6 (6 )#14-1/0 Catalog number (set of 3) Catalog number (set of 4) KT3TN KTS3TN KT4TN KT5TGD KT3TN-4 KTS3TN-4 KT4TN-4 KT5TGD-4 17 1 Includes low profile terminal cover. 2 Includes high profile terminal cover. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.79 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories Mechanical T1 - T7 Padlock locking device Frame Style Locking Position T1,T2,T3 PLL OPEN/CLOSED OPEN Ts3 FLD OPEN T4-T5 FLD OPEN T6 FLD OPEN T7 PLL OPEN Breaker Mounting Fixed Fixed, Plug-In Draw-0ut Fixed, Plug-In Draw-out Fixed, Plug-In Draw-out Fixed, Drawout Catalog number KT3LD KT3LDO KTS3FLD KTS3FLDW KT5FLD KT5FLDW KT6FLD KT6FLDW KT7LDO Keylocks-rotary handle mechanism Frame T1,T2,T3 Ts3 T4-T5 T6 T7 Style Locking Position Keys Catalog number RHL KLF-D KLF-D KLF-D OPEN/CLOSED OPEN OPEN OPEN OPEN Different Different Different Different Different KT3RHL3 KTS3KLFD KT5KLFD KT6KLFD KT7KLFD Direct mount rotary operator handle Frame KT5RH T1, T2, T3 Ts3 Ts3 T4-T5 T4-T5 T6 T6 T7 Breaker Mounting Catalog number Fixed, Plug-In Fixed, Plug-In Draw-out Fixed, Plug-In Draw-0ut Fixed, Draw-out Draw-out Fixed, Draw-out KT3RH KTS3RH KTS3RHW KT5RH KT5RHW KT6RH KT6RHW KT7RH Variable depth handle operators Frame T1--T3 OHB65J6 Ts3 17 T4-T5 OHB125J10 T6 T7 NEMA rating Mechanism catalog number Shaft catalog number 1,3R,12 -- -- 4, 4X KT3VD-M 1 -- KT3VD-S (11.8") 1,3R,12 -- OXP10X148 (5.8") 1 4,4X KTS3VD-M OXP10X225 (8.9") -- 1 -- -- OXP10X500 (19.7") KTS3VD-S (20") 1,3R,12 -- OXP10X148 (5.8") 4,4X KT5VD-M OXP10X225 (8.9") -- -- 1 -- -- -- OXP10X500 (19.7") -- KT5VD-S (19.7") 1,3R,12 -- OXP10X148 (5.8") 4,4X -- 1 KT6VD-M -- -- OXP10X225 (8.9") OXP10X500 (19.7") KT5VD-S (19.7) 1,3R,12 -- OXP10X148 (5.8") 4, 4X -- 1 KT7VD-M -- -- OXP10X225 (8.9") OXP10X500 (19.7") KT7VD-S (19.7") OXP6X430 (16.9") 1 Handle catalog number OHB65J6 OHY65J6 OHB80L6 OHY80L6 KT3VD-H OHB95J10 OHY95J10 OHB95L10 OHY95L10 -- KTS3VD-H OHB95J10 OHY95J10 OHB95L10 OHY95L10 -- -- KT5VD-H OHB125J10 OHY125J10 OHB125L10 -- KT6VD-H OHB175J10 OHY175J10 OHB175L10 -- KT7VD-H 1 Discount schedule H6. 17.80 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories Mechanical T1 - T7 Plug-in kits 1 Frame Catalog number Adapter moving part Catalog number fixed part T2 - 3 pole with front terminals KT2PMK KT2PFF T3 - 3 pole with front terminals KT3PMK KT3PFF T2-T3 Fixed parts accept the same cable and rear terminal kits as the circuit breakers Ts3 3 pole with front terminals KTS3PFF KTS3PMK Ts3 3 pole with rear terminals KTS3PFR T4 3 pole with extended front terminal KT4PFEF T4 3 pole with rear horizontal terminals KT4PMK KT4PFHR T4 3 pole with rear vertical terminals KT4PFVR T5, 400A T5 400A 3 pole with extended front terminal T5 400A 3 pole with rear horizontal terminal T5 400A 3 pole with rear vertical terminal KT2PFF + KT2PMK (on back of breaker) + breaker T5, 600A T5 600A 3 pole with extended front terminal T5 600A 3 pole with rear horizontal terminal T5 600A 3 pole with rear vertical terminal KT5PMK KT5PFEF KT5PFHR KT5PFVR KT56PMK KT56PFEF KT56PFHR KT56PFVR Plug connectors, T1-T3 Required when adding accessories to plug-in breakers Plug Connector Shunt trip or UVR 1 form C plus 1 BA 3 form C plus 1 BA KT4PFVR Catalog number KT3PC-3 KT3PC-6 KT3PC-12 Adaptors, T4-T6 Required when adding accessories to plug-in or drawout breakers Adaptors KT4PMK (on back of breaker) 1 form C plus 1 BA Shunt trip/UVR Stored energy operator Stored energy operator plus shunt trip/UVR 3 form C plus 1BA Catalog number KT5ADP-6 KT5ADP-5 KT5ADP-10 KT5ADP-10 KT5ADP-12 Testing extension, T4 - T6 Extension 5 pin for blank tests w/service release 6 pin for blank tests w/aux contacts (1+1) service and residual current releases 10 pin for blank tests w/motor operator and early contacts 12 pin for blank tests w/aux contacts (3+1) Catalog number 17 KT5EXT-5 KE5EXT-6 KT5EXT-10 KT5EXT-12 1 Plug connectors (T2-T3), Adaptors (T4-T5), required when adding accessories to plug-in breakers. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.81 1SXU000023C0202 Rev. A ax Tm CBs C M Accessories T1 - T7 Draw-out kits 1 Catalog number Adaptor moving part Item Ts3 3 pole with front terminals KT5WFVR KT4WMK (on back of breaker) KTS3WMK Ts3 3 pole with rear terminals T4 3 pole with extended front terminal T4 3 pole with rear horizontal terminals T4 3 pole with rear vertical terminals T5 3 pole with extended front terminal T5 3 pole with rear horizontal terminal T5 3 pole with rear vertical terminal T5 3 pole with extended front terminal, 600A T5 3 pole with rear horizontal terminal, 600A T5 3 pole with rear vertical terminal, 600A T6 3 pole with extended front terminal KT4WMK KT5WMK KT56WMK Catalog Number Fixed part KTS3WFF 3 KTS3WFR 3 KT4WFEF KT4WFHR KT4WFVR KT5WFEF KT5WFHR KT5WFVR KT56WFEF KT56WFHR KT56WFVR KT6WFEF 3 T6 3 pole with rear horizontal terminal T6 3 pole with rear vertical terminal T7 3 pole with horizontal/vertical terminals KT6WMK KT6WFHR 3 KT6WFVR KT7XWMK KT7WFHR 2 Adaptors -- T4-T6 Required when adding accessories to plug-in or drawout breakers Catalog number Adaptors 1 form C plus 1 BA Shunt trip/UVR Stored energy operator Stored energy operator plus shunt trip/UVR 3 form C plus 1BA KT5ADP-6 KT5ADP-5 KT5ADP-10 KT5ADP-10 KT5ADP-12 Sliding contact blocks -- T7-Draw-out Item Left Block Spring charging motor Spring charged contact Ready to close contact Early auxiliary contact Contact for trip coil release trip Trip rest Center Block PR331 PR332 Right Block Auxiliary contacts Shunt trip Closing Coil Undervoltage release 17 Moving Part Breaker Fixed Part Cradle KT7XSCMP-L KT7SCFP-L KT7XSCMP-C KT7XSCFP-C KT7XSCMP-R KT7XSCFP-R If at least one of the accessories in table is installed on the breaker - respective pair of contact blocks must be installed on the fixed part (cradle) and the moving part. (breaker) Position key lock -- T7 - T7M-X1 Item Key #20005 Different key Catalog number KT7XPL2 KT7XPL1 Locks drawout breaker in racked-in / test isolation / racked-out position. Position key lock accessory -- T7 - T7M-X1 Item Key lock accessory Catalog number KT7XPLA Accessory added to position key lock allows breaker to be locked in racked-out position only. 1 Adaptors (T4-T6), Sliding contact blocks (T7) required when adding accessories to draw-out breakers. 2 Comes standard with horizontal terminals field convertible to vertical 3 IEC 17.82 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Accessories T1 - T7 DIN rail adapters Item Catalog Number T1/T2 (mounts on 35 mm DIN rail 15mm high) T3 (mounts on 35mm DIN rail 15mm high) Ts3 (mounts on 75 mm DIN rail) KT2DIN KT3DIN KTS3DIN Mechanical interlocks T1-T3 Sliding bar interlock-front mounted (2 Breakers) Sliding bar interlock-front mounted (3 Breakers) T3 Rear Interlock-horizontal Rear Interlock-vertical Catalog Number KT3MIF2 KT3MIF3 KT3MI-H KT3MI-V TS3 Horizontal Vertical KT3MIF2 KTS3MI-H KTS3MI-V T4-T5 1 Interlock frame Mechanical Interlock frame-horizontal Mechanical Interlock frame-vertical Plate type A T4 (F-P-W) T4 (F-P-W) B T4 (F-P-W) T5 400 (F-P-W) OR T5 600 (F) C T4 (F-P-W) T5 600 (P-W) D T5 (F-P-W) T5 400 (F-P-W) OR 630 (F) E T4 (F-P-W) T5 600 (P-W) F T4 (F-P-W) T5 600 (P-W) T6 Horizontal Vertical T7 2 Cable T7-X1 Mech. interlock plate-fixed Mech. interlock plate-draw-out KT5MIR-HB KT5MIR-VB KT5MIR-PA KT5MIR-PB KT5MIR-PC KT5MIR-PD KT5MIR-PE KT5MIR-PF KT6MI-H KT6MI-V KT7XMLC KT7XMLPF KT7XMLPW Flange cable mechanisms Item Catalog Number Handles T1 - T3 Ts3 - T5 NEMA 1, 3R, 12 NEMA 4, 4X NEMA 1, 3R, 12 NEMA 4, 4X OHF1C12T OHF1C4T OHF1C12 OHF1C4 Mechanisms T1 - T2 T3 T4 - Ts3 T5 17 MKCT2 MKCT3 MKCT4 MKCT5 Cables 36" 48" 60" 72" 84" 96" 108" OXC1L36 OXC1L48 OXC1L60 OXC1L72 OXC1L84 OXC1L96 OXC1L108 1 T4-T5 Complete assembly consists of one interlock frame and one plate. 2 To interlock two circuit breakers, you have to order a cable kit and two plates. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.83 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T1 & T2 T1 -- 3 pole T1 -- Single pole 83 78 90 30 70 30 9.38 Y 17 X X 45 130 65 53.25 76.2 106.5 T2 -- 2 & 3 pole 181 17 Y >3 17.84 1SXU000023C0202 Rev. A 103 <2 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T3 T M max CC Bs T3 -- 2 & 3 pole Door cut-out for Tmax without faceplate 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.85 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions Ts3 17 17.86 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage T M max CC Bs Approximate dimensions T4 Fixed circuit breaker Caption 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) Flange for compartment door Drilling templates of the compartment door 3-4 POLES 3-4 POLES With flange Without flange 17 Drilling templates for support sheet For front terminals 3 POLES Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage For rear terminals 4 POLES 17.87 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T5 Fixed circuit breaker Fixing on sheet Caption 1 Overall dimensions with cabled accessories mounted (SOR-C, UVR-C, RC221-222) 2 Overall dimensions with cabled auxiliary contacts mounted (only 3Q 1SY) Flange for compartment door Drilling templates of the compartment door With flange (3-4 POLES) Without flange (3-4 POLES) 17 Drilling templates for support sheet For front terminals 3 POLES For rear terminals 4 POLES 3 POLES 17.88 1SXU000023C0202 Rev. A 4 POLES Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T6 T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.89 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T7 17 17.90 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T7M Fixed, 3 Pole, front terminals T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.91 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T8, Fixed, 3 pole, front terminals 1600A, 2000A, 2500A 17 17.92 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T8, Fixed, Vertical rear terminals 80% rated 3000A; 100% rated 2500A, 3000A T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.93 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T8, Fixed, Optional vertical rear terminals (KT82500VR-x) 1600A/2000A/2500A 17 17.94 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T1 - T3 Variable depth mechanism with OHB handle T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.95 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions Ts3 Variable depth mechanism with OHB handle 17 17.96 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T4 - T5 Variable depth mechanism with OHB handle T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.97 1SXU000023C0202 Rev. A ax Tm CBs C M Approximate dimensions T6 Variable depth mechanism 17 17.98 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions T7 Variable depth mechanism T M max CC Bs 17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 17.99 1SXU000023C0202 Rev. A ax Tm CBs C M Notes 17 17.100 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage