1 ___________________ Introduction 2 ___________________ System requirements SIMATIC Installing Energy Manager 3 ___________________ PRO Acquisition Connecting acquisition 4 ___________________ components to Server SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual 07/2018 A5E38952756-AB Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NURNBERG GERMANY A5E38952756-AB 07/2018 Subject to change Copyright (c) Siemens AG 2018. All rights reserved Table of contents 1 2 Introduction ................................................................................................................................................ 5 1.1 Security information ..................................................................................................................5 1.2 Use as intended ........................................................................................................................5 1.3 Functionality of the acquisition component ...............................................................................6 System requirements ................................................................................................................................. 9 2.1 General requirements ...............................................................................................................9 2.2 Requirements for Energy Manager PRO Acquisition .............................................................11 3 Installing Energy Manager PRO Acquisition ............................................................................................ 13 4 Connecting acquisition components to Server ......................................................................................... 15 4.1 Configuring acquisition components per wizard .....................................................................15 4.2 Configuring the acquisition component manually ...................................................................19 4.3 Managing the acquisition component .....................................................................................21 4.4 Areas in the Energy Manager PRO acquisition configuration ................................................23 Index ........................................................................................................................................................ 31 SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 3 Table of contents SIMATIC Energy Manager PRO V7.1 - Acquisition 4 System Manual, 07/2018, A5E38952756-AB 1 Introduction 1.1 Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial security concept. Siemens' products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens' guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit (http://www.siemens.com/industrialsecurity). Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer's exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (http://support.automation.siemens.com). 1.2 Use as intended WARNING Security note The software may be used only for the applications described in the catalog or the technical description, and only in combination with the software products, components and devices of other manufacturers where recommended or permitted by Siemens. Before you run any sample programs included with your product package, or user programs, make sure that harm to the health of human beings or damage to machinery is safely excluded during plant operation. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 5 Introduction 1.3 Functionality of the acquisition component 1.3 Functionality of the acquisition component Note Energy Manager Basic/PRO This manual is valid for both Energy Manager Basic and Energy Manager PRO. To make the manual easier to read, the term Energy Manager PRO is used instead of Energy Manager Basic/PRO. The Energy Manager PRO Acquisition or acquisition component is installed as a separate application and provides the requirements for acquiring data from the field and / or process level. In case of multiple locations, depending on the network configuration, one Energy Manager PRO acquisition component should be used for each location. In the Energy Manager PRO Acquisition component acquisition values are stored, compressed values are transferred via the Intranet / Internet to the Energy Manager PRO Server into the database. Compression functionality The acquisition component automatically compresses the acquisition values of a datapoint that are smaller than or equal to one day. Acquisition values that are larger than one day are stored without compression directly at the Energy Manager PRO Server into the database. The compression levels 1 minute, 15 minutes, 1 hour as well as 1 day are selected automatically when a datapoint is created, but can be deselected, if necessary, via the "Compression" button. Entry values are compressed to the selected compression levels and saved in the database. This means that incoming 1-minute values, for example, are compressed to 15-minute values, 1-hour values and 1-day values and the compressed values are saved in the database. Further compression levels can be selected additionally. Minimum, maximum, average, sum and power The acquisition component automatically calculates for each compressed value the minimum, the maximum, the average, the sum and the power and stores these values in addition to each compressed value into the database. Important for the correct calculation of the statistical values is a corresponding definition in the "Type" field at the datapoint (Power, Energy, Counter Value, Process Value). The statistical values are visible in the measured value editor. The time stamp is also specified for each statistical value. Details about this are available in the Operation Manual "SIMATIC Energy Manager PRO V7.1 - Operation" in section "Opening the measured value editor". SIMATIC Energy Manager PRO V7.1 - Acquisition 6 System Manual, 07/2018, A5E38952756-AB Introduction 1.3 Functionality of the acquisition component Storage and display of acquisition values The acquisition component creates an adf file per day and datapoint in which the acquisition values are stored. The files are stored locally on the acquisition and are available for 2 months (62 days). Afterwards the files, and thus also the acquisition values, are deleted. In order to ensure a rapid overview of the current values the acquisition values can be displayed in the Chart or Dashboard. A review of the acquisition values by means of the Chart or Dashboard is limited to the set storage period (62 days). Matrix and measured value editor currently do not have any functionality for displaying the acquisition values of the acquisition component. It is not possible to access the acquisition values, unless the compression level "Acquisition values" is selected at the "Compression" button in the datapoint. Then the acquisition values of the acquisition component are transferred too the database at the Energy Manager PRO Server. If compression levels are selected at the datapoint, the acquisition component compresses the acquisition values to the selected levels. The acquisition component synchronizes regularly with the Energy Manager PRO Server and in the process transfers the compressed values to the Server where the values are stored in the database. Plausibility check and message list The following plausibility checks are available for entry values directly on the acquisition component: High limit Upper limit warning Lower limit warning Low limit Gap If a plausibility check is to take place and messages are to be generated, these have to be activated at the "Plausibility" button in the datapoint. The acquisition component then checks the acquisition values for plausibility and sends a message per email or generates an entry in the message list, in as far as the message list is configured correctly. The following plausibility checks in the "Compare With" area Another Time Period Reference Object Upper Limit Lower Limit can only be checked if the entry values are available on the server. To this purpose the "Acquisition values" option has to be selected additionally in the "Compression" at the datapoint. More detailed information on the plausibility check is available in the Operation Manual "SIMATIC Energy Manager PRO V7.1 - Operation" in section "Configuring the plausibility". SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 7 Introduction 1.3 Functionality of the acquisition component Configuration of the datapoint The compression levels are selected for the datapoint in the Energy Manager PRO Client. Ensure that the correct "Type" is selected when creating the datapoint. This is necessary for the correct calculation of the statistical value. Details about compression and about the type of datapoint are available in the Operation Manual "SIMATIC Energy Manager PRO V7.1 - Operation" in section "Configuring compression". If you want to receive warning messages, activate the messages at the "Plausibility" button and configure a message list. SIMATIC Energy Manager PRO V7.1 - Acquisition 8 System Manual, 07/2018, A5E38952756-AB System requirements 2.1 2 General requirements PC is switched on and the operating system has started. One of the following operating systems is installed: - Windows 7 Professional / Ultimate SP1 32-bit / 64-bit (German / English) - Windows 8.1 Pro / Enterprise 64-bit (German / English) - Windows 10 Pro / Enterprise 64-bit (German / English) - Windows Server 2008 R2 SP1 64-bit (German / English) - Windows Server 2012 R2 64-bit (German / English) - Windows Server 2016 64-bit (German / English) The multiuser interface is installed in English or in German. Microsoft Internet Information Service (IIS) is installed and configured. - Take into account the IIS settings before the installation of Energy Manager Basic/PRO Web, in particular for the operating systems Windows 7 and Windows 8.1 as well as Windows Server. Note Installation of the Microsoft Internet Information Service (IIS) is necessary for the usage of Energy Manager Basic/PRO Web as well as for the connection (pairing) of the acquisition component with the Energy Manager Basic/PRO Server. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 9 System requirements 2.1 General requirements Microsoft .NET Framework 4.5 or higher is installed. Note Microsoft .NET Framework 3.5 and 4.5 must be installed for the Windows 8.1, Windows Server 2008 R2, Windows Server 2012 and Windows Server 10 operating systems. Adhere to the following sequence: 1. Install Microsoft Internet Information Service (IIS). 2. Install Microsoft .NET Framework. If you have installed .NET Framework before the IIS, repeat the installation of .NET Framework. Additional information is available in the FAQ in Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en/78464533). Additional information on .NET is available on the Internet (http://www.microsoft.com/en-US/download/details.aspx?id=30653). Note Microsoft SQL Server 2014 A license is necessary to use the Microsoft SQL Server database. This license is readily available in a licensed and proper installation of Energy Manager Basic/PRO. Use the licensed SQL Server installed with Energy Manager Basic/PRO only in connection with Energy Manager Basic/PRO. Its use for other purposes requires an additional license. These include, e.g.: * Use for internal databases * Use in third-party applications * Use of SQL access mechanisms that are not provided by Energy Manager Basic/PRO SIMATIC Energy Manager PRO V7.1 - Acquisition 10 System Manual, 07/2018, A5E38952756-AB System requirements 2.2 Requirements for Energy Manager PRO Acquisition 2.2 Requirements for Energy Manager PRO Acquisition The following requirements apply to the Energy Manager PROAcquisition: Type Requirement Comment Port number The port number "4444" is set as default. For communication with the Energy Manager PRO application server. You can choose any available port number. A Web browser is also required for the connection configuration. Software Hardware One of the approved Internet browsers is installed. * Internet Explorer 11 * Microsoft Edge * Chrome * Firefox 55 or higher * Safari with iOS 11 For the configuration of the connection (Pairing) of the acquisition component (Acquisition) with the Energy Manager PRO Server. Processor: Intel / AMD desktop processor, 2 GHz or higher - Work memory RAM: 2 GB - Hard drive: 80 GB - CD-ROM/DVD-ROM drive For software installation SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 11 System requirements 2.2 Requirements for Energy Manager PRO Acquisition SIMATIC Energy Manager PRO V7.1 - Acquisition 12 System Manual, 07/2018, A5E38952756-AB Installing Energy Manager PRO Acquisition 3 Introduction Energy Manager PRO Acquisition enables you to meet the PC requirements for acquiring data from the field and / or process level. The acquired data are forwarded to an Energy Manager PRO Server server via the Intranet / Internet. The installation of Energy Manager PRO supports the following installation methods: Package installation Installs the following components: - Portal service - Energy Manager PRO Acquisition component - Hotfolder Manager Service Custom installation Installs at least the Portal service. Requirement You have administrator rights in Microsoft Windows. The SIMATIC Energy Manager PRO Acquisition DVD has been inserted in the DVD drive. Procedure 1. Double-click the "Setup.exe" file on the SIMATIC Energy Manager PRO Acquisition DVD. If user account control is activated, you must allow the execution of the program. The language selection dialog opens. 2. Select the required language for the installation. The installation wizard opens. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 13 Installing Energy Manager PRO Acquisition 3. Read and agree to the following information if necessary: - General information - Licensing agreements and safety information - Version information Note A message is displayed if Energy Manager PRO is already installed. If you want to continue the setup, the components listed above are overwritten. Otherwise, setup is aborted. The "Installation type" dialog opens. 4. Select the desired installation type and the destination directory if needed. 5. If you have selected "Custom installation", select the desired components. A summary of the components to be installed is displayed. 6. Enter the Windows login data for the additional services and then click "Install". "Energy Manager PRO Acquisition" is installed. When installation is complete, you are requested to reboot the PC. 7. Restart the computer. Result "Energy Manager PRO Acquisition" is installed. If you have installed the Energy Manager PRO Acquisition component, connect it subsequently with the Energy Manager PRO Server (Pairing). Additional information is available in the section "Connecting acquisition components to Server (Page 15)". SIMATIC Energy Manager PRO V7.1 - Acquisition 14 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.1 4 Configuring acquisition components per wizard Overview In the Energy Manager PRO acquisition configuration you establish the logical connection between the acquisition component (Acquisition) and the Energy Manager PRO Server (Pairing). The Energy Manager PRO acquisition configuration is installed together with the "Energy Manager PRO Acquisition" software component. The acquisition component supports communication via a proxy server. You can configure the connection to the Energy Manager PRO Server either by using the wizard or manually. Configuring the connection manually You can configure the connection to the Energy Manager PRO Server with or without access to the Energy Manager PROServer. The connection is created when saving the configuration data. If the Energy Manager PRO Server cannot be reached, the configuration is saved locally. Upon restarting the Energy Manager PRO acquisition configuration, an attempt is made to establish the connection using the saved configuration. Setting up a connection using the wizard Configuration with the wizard requires a connection to the Energy Manager PRO Server. The wizard performs a step by step check of the connection data that have been entered. Configuring the connection using the wizard You need the following data to log the acquisition component in to the Energy Manager PRO Server: Address and port of the Energy Manager PRO Server Energy Manager PRO user name and password Name of the "Hardware" object in Energy Manager PRO SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 15 Connecting acquisition components to Server 4.1 Configuring acquisition components per wizard Requirement The "Energy Manager PRO Acquisition" software component is installed on the PC. Microsoft Internet Information Service (IIS) is installed on the PC. The PC is connected to the Energy Manager PRO Server. The "Hardware" object is set up on the Energy Manager PRO Server. A user with the "Configure acquisition" authorization is set up on the Energy Manager PRO Server. For communication via proxy: - A proxy server must be available in the network. - The URL and login data must be known. Procedure 1. Start the web browser on the acquisition component and enter the following address: http://[COMPUTERNAME]/EnMPROAcquisition/Login.aspx 2. Log on with the operating system user under which Energy Manager PRO was also installed. The "Status" page of the Energy Manager PRO acquisition configuration is displayed. If the acquisition component is not yet logged in to a Energy Manager PRO Server, the "Configure the acquisition" dialog is displayed. 3. Select the "Start connection wizard" option in the "Configure the acquisition" dialog. SIMATIC Energy Manager PRO V7.1 - Acquisition 16 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.1 Configuring acquisition components per wizard 4. Enter the following connection data: - Address and port of the Energy Manager PRO Server 5. As needed, select "Configure proxy settings", and enter the following connection data depending on the configuration of the proxy server: - Address and port of the proxy server - User name and password - Click on "Test connection". 6. Enter your Energy Manager PRO user name and password and click "Login". An acquisition ID is allocated and the name of the acquisition computer is displayed. 7. Save your entries. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 17 Connecting acquisition components to Server 4.1 Configuring acquisition components per wizard Result The "Acquisition ID" is generated and entered for the connection between the acquisition component and the Energy Manager PRO Server. The figure below shows a correctly configured connection to the Energy Manager PRO Server: SIMATIC Energy Manager PRO V7.1 - Acquisition 18 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.2 Configuring the acquisition component manually 4.2 Configuring the acquisition component manually Overview The connection to the Energy Manager PRO Server can be configured both with and without access to the Energy Manager PRO Server . The connection to the Energy Manager PRO Server is established when the configuration data are saved. If the Energy Manager PRO Server cannot be reached, the configuration is saved locally. Upon restarting the Energy Manager PRO acquisition configuration, an attempt is made to establish the connection using the saved configuration. Requirement The "Energy Manager PRO Acquisition" software component is installed on the PC. Microsoft Internet Information Service (IIS) is installed on the PC. The PC is connected to the Energy Manager PRO Server (optional). The "Hardware" object is set up on the Energy Manager PRO Server. A user with the "Configure acquisition" authorization is set up on the Energy Manager PRO Server. For communication via proxy: - A proxy server must be available in the network. - The URL and login data must be known. Procedure 1. Start the web browser on the acquisition component and enter the following address: http://[COMPUTERNAME]/EnMPROAcquisition/Login.aspx 2. Log on with the operating system user under which Energy Manager PRO was also installed. The "Status" page of the Energy Manager PRO acquisition configuration is displayed. If the acquisition component is not yet logged in to a Energy Manager PRO Server, select the "Manually configure connection" option in the "Configure the acquisition" dialog that is displayed. 3. Enter the following connection data in the "Settings" area: - Address and port of the Energy Manager PRO Server - Energy Manager PRO user name and password - Name of the "Hardware" object in Energy Manager PRO SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 19 Connecting acquisition components to Server 4.3 Managing the acquisition component 4. As needed, select "Configure proxy settings", and enter the following connection data depending on the configuration of the proxy server: - Address and port of the proxy server - User name and password 5. Save your entries. Connection setup to the Energy Manager PRO Server is started. If connection to the Energy Manager PRO Server is not possible, your configuration is saved locally. Upon the next restart of the acquisition component, a connection will be attempted using the saved configuration. You can start the acquisition component once more by using "Start / Restart". Result The acquisition ID is generated and entered as soon as the Energy Manager PRO Server can be reached. Connection setup is started again upon each restart of the acquisition component with the specified data. Provision of the acquisition configuration depends on the configured start delay time of the acquisition service. The figure below shows a correctly configured connection to the Energy Manager PRO Server: SIMATIC Energy Manager PRO V7.1 - Acquisition 20 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.3 Managing the acquisition component 4.3 Managing the acquisition component Overview You use the Energy Manager PRO acquisition component for the following tasks: Start or stop acquisition service Modify or reset the connection data Configuring a proxy server for the communication Execute the software update for the acquisition component Navigation area Display and configuration area. The content depends on the selection in the navigation area. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 21 Connecting acquisition components to Server 4.3 Managing the acquisition component Requirement The Energy Manager PRO acquisition configuration is displayed in the Web browser. The acquisition component is connected to the Energy Manager PRO Server. Start or stop acquisition service 1. Click "Status" in the navigation area. 2. Click the appropriate button. If the acquisition service is stopped, data is not acquired. Changing configuration settings 1. Click "Status" in the navigation area. 2. If you want to assign the acquisition component to another "Hardware" object, reset the acquisition service. 3. If you want to change the user data, stop the acquisition service. 4. Click on "Settings" or "Wizard" in the navigation area. 5. Enter the connection data. Reset configuration settings 1. Click "Status" in the navigation area. 2. Click the appropriate button. The configuration settings of the acquisition component are deleted after confirmation. The acquisition component is not acquiring data any longer. 3. Log the acquisition component in to a Energy Manager PRO Server again afterward. Configuring a proxy server for the communication 1. Click "Status" in the navigation area. 2. Click "Configure proxy settings" 3. Depending on the configuration of the proxy server, enter the following connection data: - Address and port of the proxy server - User name and password Updating acquisition software 1. Click "About" in the navigation area. 2. Enter the path and file name of the setup file under "Software update", for example, "C:\Installation\Setup.exe". 3. Click "Update". The acquisition service is stopped and the acquisition software is updated. The acquisition service is started once again when the installation is complete. SIMATIC Energy Manager PRO V7.1 - Acquisition 22 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration 4.4 Areas in the Energy Manager PRO acquisition configuration Structure of the Energy Manager PRO acquisition configuration The figure below shows the structure of the Energy Manager PRO acquisition configuration after login: Navigation area * Status: Indicates the connection status of the acquisition component. * Settings: Displays the current configuration settings. * Wizard: Starts the wizard for input of the configuration settings. * Help: Opens the documentation on the Energy Manager PRO acquisition component in PDF format. * About: Displays the installed software version. You can update the software version. * Logout: Displays the login window of the Energy Manager PRO acquisition configuration again. Display and configuration area. The content depends on the selection in the navigation area. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 23 Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration "Status" area The "Status" area of the Energy Manager PRO acquisition configuration consists of the following areas: Area Entry Description Server connection - - Server Address Displays the name of the Energy Manager PRO Server. Status Displays the status of the connection to the Energy Manager PRO Server. The following statuses are possible: Acquisition Service (Kernel) * Green/online: The acquisition component is connected to the Energy Manager PRO Server. * Gray/offline: The acquisition component is not connected to the Energy Manager PRO Server. - - Status Indicates the acquisition state. The following statuses are possible: * Started: The acquisition has started and is running. * Stopped: The acquisition is stopped. Acquisition Name Displays the name of the hardware object. Acquisition ID Displays the acquisition ID which uniquely identifies the connection between the Energy Manager PRO Server and the acquisition component. Current Date/Time OS Shows the current date and time of the PC on which the acquisition is running. SIMATIC Energy Manager PRO V7.1 - Acquisition 24 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration Area Entry Description Configuration Status - - Connection Configuration Shows whether the connection to the Energy Manager PRO Server has already been configured. Current Acquisition Configuration Displays the status of the current acquisition configuration. The following statuses are possible: * Received: The acquisition configuration has been successfully synchronized with the Energy Manager PRO Server. * Not Received: The acquisition configuration has not been successfully synchronized with the Energy Manager PRO Server. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 25 Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration "Settings" area The "Settings" area of the Energy Manager PRO acquisition configuration consists of the following areas: Area Server Entry Server Address Port Description Displays the name of the Energy Manager PRO Server. Displays the port of the Energy Manager PRO Server. Displays the status of the connection to the Energy Manager PRO Server. The following statuses are possible: * Green/online: The acquisition component is connected to the Energy Manager PRO Server. Gray/offline: The acquisition component is not connected to the Energy Manager PRO Server. Indicates whether a proxy server will be used for the communication. The following statuses are possible: * Proxy server User settings Acquisition entry Configure proxy settings Energy Manager PRO user name Password Acquisition Name Acquisition ID * Use system proxy settings: The proxy server that is configured in the operating system will be used. * Manual proxy configuration: Proxy server is manually configured: The server address and port are required. The type of authorization depends on the proxy server that is used. Energy Manager PRO user name Password of the Energy Manager PRO user name (encrypted) Name of the "Hardware" object Uniquely identifies the connection between the Energy Manager PRO Server and the acquisition component. SIMATIC Energy Manager PRO V7.1 - Acquisition 26 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration "Wizard" area The "Wizard" guides you through three steps for logging the acquisition component in to the Energy Manager PRO Server. To run the wizard, the acquisition component must be connected to the Energy Manager PRO Server. The area of the wizard in "Step 1" contains the following entries: Entry Description Server Address Energy Manager PRO Server Name Port Port number of the Energy Manager PRO Server Proxy server Activates configuration of a proxy server. Status Displays the status of the connection to the Energy Manager PRO Server. Test connection Checks the connection between the Energy Manager PRO Server and the acquisition component. The next step is only displayed when the check is successfully completed. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 27 Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration The area of the wizard in "Step 2" contains the following entries: Entry Description User Energy Manager PRO user name Password Password of the Energy Manager PRO user name (encrypted) Login Registers the user in Energy Manager PRO. The next step is only displayed when the login is successfully completed. The area of the wizard in "Step 3" contains the following entries: Entry Description Connecting new acquisition Shows only the "Hardware" type objects configured in Energy Manager PRO under "Select acquisition" that have not yet been connected to an acquisition component. Replace existing acquisition Shows all the "Hardware" type objects configured in Energy Manager PRO under "Select acquisition". Select acquisition Assigns the acquisition component to the "Hardware" type object configured in Energy Manager PRO. If you have enabled the "Replace existing acquisition" option, the existing assignment to this object is deleted. Save Generates the acquisition ID, which uniquely identifies the connection between the Energy Manager PRO Server and the acquisition component. SIMATIC Energy Manager PRO V7.1 - Acquisition 28 System Manual, 07/2018, A5E38952756-AB Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration "About" area The "About" area of the Energy Manager PRO acquisition configuration consists of the following entries: Entry Description System version Shows the software version installed on the acquisition component. Software update Path and file name of the Setup file for updating the software, for example, "\\UpdateServer\EnMPRO\Setup.exe". Execute Starts the software update. The acquisition component is restarted following the update. SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 29 Connecting acquisition components to Server 4.4 Areas in the Energy Manager PRO acquisition configuration SIMATIC Energy Manager PRO V7.1 - Acquisition 30 System Manual, 07/2018, A5E38952756-AB Index A W Acquisition software Updating, 22 Administrator rights, 13 Windows operating system Energy Manager PRO, 9 C Connecting acquisition components to server Configuring acquisition components per wizard, 16 Configuring the acquisition component manually, 19 Connection manual configuration, 19 E Energy Manager PRO System requirements, 9 Energy Manager PRO Acquisition Installing with the product DVD, 13 Energy Manager PRO acquisition configuration, 15, 19 M Managing the acquisition component Changing, resetting the acquisition component, 21 Starting, stopping acquisition component, 21 Updating the acquisition software, 21 manual configuration Connection, 19 P Proper usage, 5 R Requirements Energy Manager PRO Acquisition, 11 U Update Acquisition software, 22 SIMATIC Energy Manager PRO V7.1 - Acquisition System Manual, 07/2018, A5E38952756-AB 31 Index SIMATIC Energy Manager PRO V7.1 - Acquisition 32 System Manual, 07/2018, A5E38952756-AB