FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
H
Multi-function and mono-function timer range
80.01 - Multi-function & multi-voltage
80.11 - On-delay, multi-voltage
17.5mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35mm rail (EN60715) mount
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
New multi-voltage versions with “PWM clever”
technology
80.01 / 80.11
Screw terminal
80.01 80.11
Multi-voltage
Multi-function
Multi-voltage
Mono-function
AI: On-delay
DI: Interval
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
AI: On-delay
Wiring diagram
(without control signal)
Wiring diagram
(with control signal)
Wiring diagram
(without control signal)
For UL ratings see:
General technical informationpage V
For outline drawing see page 9
Contact specification
Contact configuration 1 CO (SPDT) 1 CO (SPDT)
Rated current/Maximum peak current A 16/30 16/30
Rated voltage/
Maximum switching voltage VAC 250/400 250/400
Rated load AC1 VA 4000 4000
Rated load AC15 (230VAC) VA 750 750
Single phase motor rating (230VAC) kW 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 16/0.3/0.12
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi
Supply specification
Nominal voltage (UN) VAC (50/60Hz) 12…240 24…240
VDC 12…240 24…240
Rated power AC/DC VA (50Hz)/W <1.8/<1 <1.8/<1
Operating range VAC 10.8…265 16.8…265
VDC 10.8…265 16.8…265
Technical data
Specified time range (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
Repeatability % ±1 ±1
Recovery time ms 100 100
Minimum control impulse ms 50
Setting accuracy-full range % ±5 ±5
Electrical life at rated load in AC1 cycles 50·10350·103
Ambient temperature range °C –10…+50 –10…+50
Protection category IP 20 IP 20
Approvals (according to type)
3
V-2019, www.findernet.com
80
SERIES
80 SERIES
Modular timers 16A
H
Mono-function timer range
80.21 - Interval, multi-voltage
80.41 - Off-delay with control signal, multi-voltage
80.91 - Asymmetrical flasher, multi-voltage
17.5mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35mm rail (EN60715) mount
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
New multi-voltage versions with “PWM clever”
technology
80.21 / 80.41 / 80.91
Screw terminal
80.21 80.41 80.91
Multi-voltage
Mono-function
Multi-voltage
Mono-function
Multi-voltage
Mono-function
DI: Interval BE: Off-delay with control signal LI: Asymmetrical flasher
(starting pulse on)
LE: Asymmetrical flasher (starting
pulse on) with control signal
Wiring diagram
(without control signal)
Wiring diagram
(with control signal)
Wiring diagram
(without control
signal)
Wiring diagram
(with control
signal)
For UL ratings see:
General technical informationpage V
For outline drawing see page 9
Contact specification
Contact configuration 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT)
Rated current/Maximum peak current A 16/30 16/30 16/30
Rated voltage/
Maximum switching voltage V
AC 250/400 250/400 250/400
Rated load AC1 VA 4000 4000 4000
Rated load AC15 (230VAC) VA 750 750 750
Single phase motor rating (230VAC) kW 0.55 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 16/0.3/0.12 16/0.3/0.12
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi AgNi
Supply specification
Nominal voltage (UN) VAC (50/60Hz) 24…240 24…240 12…240
VDC 24…240 24…240 12…240
Rated power AC/DC VA (50Hz)/W <1.8/<1 <1.8/<1 <1.8/<1
Operating range VAC 16.8…265 16.8…265 10.8…265
VDC 16.8…265 16.8…265 10.8…265
Technical data
Specified time range (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
Repeatability % ±1 ±1 ±1
Recovery time ms 100 100 100
Minimum control impulse ms 50 50
Setting accuracy-full range % ±5 ±5 ±5
Electrical life at rated load in AC1 cycles 50·10350·10350·103
Ambient temperature range °C –10…+50 –10…+50 –10…+50
Protection category IP 20 IP 20 IP 20
Approvals (according to type)
4
V-2019, www.findernet.com
80 SERIES
Modular timers 16A
80
SERIES
H
Multi-function and multi-voltage solid-state
output timer
17.5mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35mm rail (EN60715) mount
Multi-voltage output (24…240 VAC/DC),
independent from the input voltage
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
Multi-voltage input with “PWM clever”
technology
80.71
Screw terminal
80.71
Multi-voltage
Multi-function
AI: On-delay
DI: Interval
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
Wiring diagram
(without control signal)
Wiring diagram
(with control signal)
For outline drawing see page 9
Output circuit
Contact configuration 1 NO (SPST-NO)
Rated current A 1
Rated voltage VAC/DC 24…240
Switching voltage range VAC/DC 19…265
Rated load AC15 A 1
Rated load DC1 A 1
Minimum switching current mA 0.5
Max. “OFF-state leakage current mA 0.05
Max. “ON-state voltage drop V 2.8
Input circuit
Nominal voltage (UN) VAC (50/60Hz) 24…240
VDC 24…240
Rated power VA (50Hz)/W 1.3/1.3
Operating range VAC 19…265
VDC 19…265
Technical data
Specified time range (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
Repeatability % ±1
Recovery time ms 100
Minimum control impulse ms 50
Setting accuracy-full range % ±5
Electrical life cycles 100·106
Ambient temperature range °C –20…+50
Protection category IP 20
Approvals (according to type)
5
V-2019, www.findernet.com
80
SERIES
80 SERIES
Modular Solid State timer (SST) 1A
H
Mono-function timer range
80.61 - Power off-delay (True off-delay),
multi-voltage
80.82 - Star-delta, multi-voltage
17.5 mm wide
Rotary range selector, and timing trimmer
Four time scales from 0.05s to 180 s (type 80.61)
Six time scales from 0.1s to 20min (type 80.82)
High input/output isolation
35mm rail (EN60715) mount
80.61 / 80.82
Screw terminal
80.61 80.82
Multi-voltage
Mono-function
Multi-voltage
Mono-function
Transfer time can be regulated (0.05…1)s
BI: Power off-delay (True off-delay) SD: Star-delta
Wiring diagram
(without control signal)
Wiring diagram
(without control signal)
For UL ratings see:
General technical informationpage V
For outline drawing see page 9
Contact specification
Contact configuration 1 CO (SPDT) 2 NO (DPST-NO)
Rated current/Maximum peak current A 8/15 6/10
Rated voltage/
Maximum switching voltage V
AC 250/400 250/400
Rated load AC1 VA 2000 1500
Rated load AC15 (230VAC) VA 400 300
Single phase motor rating (230VAC) kW 0.3
Breaking capacity DC1: 30/110/220 V A 8/0.3/0.12 6/0.2/0.12
Minimum switching load mW (V/mA) 300 (5/5) 500 (12/10)
Standard contact material AgNi AgNi
Supply specification
Nominal voltage (UN) VAC (50/60Hz) 24…240 24…240
VDC 24…220 24…240
Rated power AC/DC VA (50Hz)/W <0.6/<0.6 <1.3/<0.8
Operating range VAC 16.8…265 16.8…265
VDC 16.8…242 16.8…265
Technical data
Specified time range (0.05…2)s, (1…16)s, (8…70)s, (50…180)s (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min
Repeatability % ±1 ±1
Recovery time ms 100
Minimum control impulse ms 500 (A1-A2)
Setting accuracy-full range % ±5 ±5
Electrical life at rated load in AC1 cycles 100·10360·103
Ambient temperature range °C –10…+50 –10…+50
Protection category IP 20 IP 20
Approvals (according to type)
6
V-2019, www.findernet.com
80 SERIES
Modular timers 6- 8A
80
SERIES
H
7
V-2019, www.findernet.com
80
SERIES
80 SERIES
Modular timers 8 A
Multi-function and multi-voltage
17.5mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35mm rail (EN60715) mount
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
New multi-voltage versions with “PWM clever”
technology
80.51.0.240.0000
Screw terminal
80.51.0.240.P000
Push-in terminal
80.51
Multi-voltage (24…240)VAC/DC
Multi-function
AI: On-delay
DI: Interval
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
Wiring diagram
(without control signal)
Wiring diagram
(with control signal)
For UL ratings see:
General technical informationpage V
For outline drawing see page 9
Contact specification
Contact configuration 1 CO (SPDT)
Rated current/Maximum peak current A 8/16
Rated voltage/
Maximum switching voltage VAC 250/400
Rated load AC1 VA 2000
Rated load AC15 (230VAC) VA 400
Single phase motor rating (230VAC) kW 0.3
Breaking capacity DC1: 30/110/220 V A 8/0.3/0.12
Minimum switching load mW (V/mA) 500 (10/5)
Standard contact material AgNi
Supply specification
Nominal voltage (UN) VAC (50/60Hz) 24…240
VDC 24…240
Rated power AC/DC VA (50Hz)/W <1.8/<1
Operating range VAC 17…265
VDC 17…265
Technical data
Specified time range (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
Repeatability % ±1
Recovery time ms ≤50
Minimum control impulse ms 50
Setting accuracy-full range % ±5
Electrical life at rated load in AC1 cycles 100·103
Ambient temperature range °C –10…+50
Protection category IP 20
Approvals (according to type)
H
Ordering information
Example: 80 series, modular timers, 1 CO (SPDT) - 16A, supply rated at (12…240)VAC/DC.
8 0 . 0 1 . 0 . 2 4 0 . 0 0 0 0
Series
Type
0 = Multi-function (AI, DI, SW, BE, CE, DE)
1 = On-delay (AI)
2 = Interval (DI)
4 = Off-delay with control signal (BE)
5 = Multi-function (AI, DI, SW, BE, CE, DE)
6 = Power off-delay (True off-delay) (BI)
7 = Multi-function with solid state output
(AI, DI, SW, BE, CE, DE)
8 = Star-delta (SD)
9 = Asymmetrical flasher (LI, LE)
Versions
0 = Standard
P = Push-in (only for 80.51)
Supply voltage
240 = (12…240)VAC/DC (80.01, 80.91)
240 = (24…240)VAC/DC
(80.11, 80.21, 80.41, 80.51, 80.71, 80.82)
240 = (24…240)VAC, (24…220)VDC (80.61)
Supply version
0 = AC (50/60Hz)/DC
No. of poles
1 = 1 CO (SPDT)
1 = 1 NO (SPST-NO), type 80.71 only
2 = 2 NO (DPST-NO), type 80.82 only
Technical data
Insulation
Dielectric strength 80.01/11/21/41/51/82/91 80.61 80.71
between input and output circuit VAC 4000 2500 2500
between open contacts VAC 1000 1000
Insulation (1.2/50µs) between input and output kV 6 4 4
EMC specifications
Type of test Reference standard 80.01/11/21/41/61/71/91 80.51/82
Electrostatic discharge contact discharge EN61000-4-2 4kV 4kV
air discharge EN61000-4-2 8kV 8kV
Radio-frequency electromagnetic field (80 ÷ 1000MHz) EN61000-4-3 10V/m 10V/m
Fast transients (burst) (5-50ns, 5kHz) on Supply terminals EN 61000-4-4 4kV 4kV
Surges (1.2/50µs) on Supply terminals common mode EN61000-4-5 4kV 4kV
differential mode EN61000-4-5 4kV 4kV
on start terminal (B1) common mode EN61000-4-5 4kV 4kV
differential mode EN61000-4-5 4kV 4kV
Radio-frequency common mode (0.15 ÷ 80MHz) on Supply terminals EN61000-4-6 10V 10V
Radiated and conducted emission EN55022 class B class A
Other data
Current absorption on signal control (B1) <1mA
Power lost to the environment without contact current W 1.4
with rated current W 3.2
Terminals Screw terminals Push-in terminals
Wire strip length mm 10 10
Screw torque Nm 0.8
Min. wire size solid cable solid cable
mm20.5 0.75
AWG 20 18
Max. wire size solid cable solid cable
mm21x6 / 2x4 1x1.5 / 2x1.5
AWG 1x10 / 2x12 1x16 / 2x16
Min. wire size stranded cable stranded cable
mm20.5 0.75
AWG 20 18
Max. wire size stranded cable stranded cable
mm21x4 / 2x2.5 1x2.5 / 2x2.5
AWG 1x12 / 2x14 1x14 / 2x14
8
V-2019, www.findernet.com
80 SERIES
Modular timers 1- 6- 8- 16A
80
SERIES
H
Outline drawings
Types 80.01/80.51
Screw terminal
Type 80.51
Push-in terminal
4.356.5
45
17.5
30.5 33.8
89.8
86
Types 80.11/80.21/80.61
Screw terminal
Type 80.41
Screw terminal
Type 80.91
Screw terminal
Type 80.71
Screw terminal
Type 80.82
Screw terminal
9
V-2019, www.findernet.com
80
SERIES
80 SERIES
Modular timers 1- 6- 8- 16A
H
Functions
U = Supply voltage
S = Signal switch
= Output contact
LED* Supply voltage NO output
contact
Contacts
Open Closed
OFF Open 15 - 18 15 - 16
ON Open 15 - 18 15 - 16
ON Open
(Timing in Progress) 15 - 18 15 - 16
ON Closed 15 - 16 15 - 18
* The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED
is not illuminated.
Wiring diagram
Without control signal = Start via contact in supply line (A1).
With control signal = Start via contact into control terminal (B1).
Without control signal
80.01
80.51
80.71
Type
80.01
80.51
80.71
(AI) On-delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI) Interval.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(SW) Symmetrical flasher (starting pulse on).
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on= time off).
With control signal
80.01
80.51
80.71
80.01
80.51
80.71
(BE) Off-delay with control signal.
Power is permanently applied to the timer. The output
contacts transfer immediately on closure of the Signal Switch
(S). Opening the Signal Switch initiates the preset delay, after
which time the output contacts reset.
(CE) On- and off-delay with control signal.
Power is permanently applied to the timer. Closing the Signal
Switch (S) initiates the preset delay, after which time the output
contacts transfer. Opening the Signal switch initiates the same
preset delay, after which time the output contacts reset.
(DE) Interval with control signal on.
Power is permanently applied to the timer.
On momentary or maintained closure of Signal Switch (S), the
output contacts transfer, and remain so for the duration of the
preset delay, after which they reset.
NOTE: The function must be set before energising the timer.
Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).
** A voltage other than the supply voltage can be applied to the command Start (B1), example:
A1 - A2 = 230VAC
B1 - A2 = 12VDC
10
V-2019, www.findernet.com
80 SERIES
Modular timers 1- 6- 8- 16A
80
SERIES
H
Functions
Wiring diagram
Without control signal
80.11/21/61
80.82
Type
80.11
(AI) On-delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
80.21 (DI) Interval.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
80.61 (BI) Power off-delay (True off-delay).
Apply power to timer (minimum 500ms). Output contacts
transfer immediately. Removal of power initiates the preset
delay, after which time the output contacts reset.
80.82 (SD) Star-delta.
Apply power to timer. The star contact ( ) closes immediately.
After preset delay has elapsed the star contact (
) resets.
After a further transfer time variable from (0.05…1)s the delta
contact ( ) closes and remains in that position, until reset on
power off.
With control signal
80.41
80.41 (BE) Off-delay with control signal.
Power is permanently applied to the timer.
The output contacts transfer immediately on closure of the
Signal Switch (S). Opening the Signal Switch initiates the preset
delay, after which time the output contacts reset.
Without control signal
80.91
With control signal
80.91
80.91 (LI) Asymmetrical flasher (starting pulse on).
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is applied.
The ON (T1) and OFF (T2) times are independently adjustable.
(LE) Asymmetrical flasher (starting pulse on) with control
signal
Power is permanently applied to the timer.
Closing Signal Switch (S) causes the output contacts to transfer
immediately and cycle between ON (T1) and OFF (T2), until
opened.
Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1.
* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).
** A voltage other than the supply voltage can be applied to the command Start (B1), example:
A1 - A2 = 230VAC
B1 - A2 = 12VDC
11
V-2019, www.findernet.com
80
SERIES
80 SERIES
Modular timers 6- 8- 16A
H
Times scales
Rotary switch position series 80
(0.1
2)s (1
20)s (0.1
2)min (1
20)min (0.1
2)h (1
24)h
Accessories
060.48
Sheet of marker tags (CEMBRE Thermal transfer printers) for relays types
80.01/11/21/41/51/61/71 (48 tags), 6x12mm 060.48
Please see general technical information
12
V-2019, www.findernet.com
80 SERIES
Modular timers 1- 6- 8- 16A