Silicon Pressure Sensors
Compensat ed Pressure Sensing XCX, XCXL Series
Sensing and Control
FEATURES
Pressure Ranges from 4 in
H2O, 10 in H2O and 1 psi
through 240 psi
Calibrated offset
Listings Calibrated for Full
Scale span to ±1.0 % Over
Compensated Temperature
Range
High Grade Listings
Calibrated for Full Scale
span to ±0.5 % Over
Compensated Temperature
Range
Temperature Compensated
over 0 °C to 70 °C
[32 °F to 158 °F]
Gage, Differential, and
Absolute Pressure
Ratiometric mV Output
TYPICAL APPLICAT IONS
Medical Applications
Applications Requiring
Small Size
Applications Requiring
Vacuum, Positive Pressure
or Both
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could res ult in pers on al
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
GENERAL DESCRIPTION
The XCXL, XCX Series integrates silicon micromachined sensing
technology, temper ature co mpensation, and ca li bration in an im pr oved
performance industry standard package. A unique stress isolating design
protects against torque induced. Additional stability and long term accuracy
improvements are gained through simplified compensation techniques,
which eliminate temperature dependent thermal compensation.
This series is available in a commercial (XCX-DNC) performance level. This
performance level provides the calibration accuracy of offset thermal
compensation, and linearity providing added flexibility to meet critical
performance budgets. The XCA and XCR Series provide amplified output as
well as integrated compensation.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only.
Do not use this document as a product installation guide.
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Silicon Pressure Sensors
Compensat ed Pressure Sensing XCX, XCXL Series
2 Honeywell Sensi ng an d Contr ol
ELECTRICAL SPECIFICATIONS at 12 Vdc excitation at 25 °C1 [77 °F]
XCX and XCXL – C grade XCX and XCXL – H grade Units
Min. Typ. Max. Min. Typ. Max.
Excitation Voltage 3.0 12.0 16.0 3.0 12.0 16.0 Vdc
Null -- -- 1.0 -- ±0.5 ±1.0 mV
Temperature Error on Offset
0 °C to 50 °C [32 °F to 122 °F]2
(4 in H2O) -- -- 1.0 -- -- 0.5 mV
Temperature Error on Offset
0 °C to 70 °C [32 °F to 158 °F]2
(all except 4 in H2O) -- -- 1.0 -- -- 0.5 mV
Temperature Error on Span
0 °C to 50 °C [32 °F to 122 °F]2
(4 in H2O) -- -- 2.0 -- -- 1.0 % Span
Temperature Error on Span
0 °C to 70 °C [32 °F to 158 °F]2
(all except 4 in H2O) -- -- 2.0 -- -- 1.0 % Span
Linearity, Hysteresis Error3 -- 0.5 1.0 -- 0.3 0.5 % Span
Repeatability -- 0.1 -- -- 0.1 -- % Span
Input Resistance -- 15 -- 15 -- k
Output Resistance -- 3.0 -- -- 3.0 -- k
Compensated Temperature Range 0 [32] 25 [77] 70 [158] 0 [32] 25 [77] 70 [158] °C [°F]
Storage Temperature Range -40 [-40] -- 125 [257] -40 [-40] -- 125 [257] °C [°F]
Relative Humidity (non-condensing) 0 95 0 95 % RH
Common Mode Pressure -- -- 50 -- -- 50 psig
Shock (Duration 11 ms any axis) 10 10
g
Weight -- 2 -- -- 2 --
gram
Note 1: All parameters are m easured at 12 Vdc excitat i on, press ure specs obtained with press ure applied to the front of the sensor.
Note 2: Shift is relative to 25 °C [77 °F]
Note 3: Measured at ½ full scale rated pressure using BFSL
DIFFERENTIAL AND GAGE OUTPUT at 12 Vdc excitation at 25 °C [77 °F]
XCX C- Grade Output
Full Scale Span, (mV) XCX H Grade Output Full
Scale Span, (mV)
Full Scale Pressure Min. Typ. Max. Min. Typ. Max.
Max.
Overpressure
(psi)
4 in H2O 38 40 42 -- -- -- 5
10 in H2O 19 20 21 19.8 20.0 20.2 5
0.3 psi 19 20 21 19.8 20.0 20.2 5
1 psi 17 18 19 17.8 18.0 18.2 5
5 psi 57 60 63 59 60 61 15
15 psi 85 90 95 89 90 91 45
30 psi 85 90 95 89 90 91 90
60 psi 85 90 95 89 90 91 180
100 psi 95 100 105 99 100 101 200
150 psi 85 90 95 89 90 91 300
240 psi 95 100 105 99 100 101 300
Silicon Pressure Sensors
Compensat ed Pressure Sensing XCX, XCXL Series
Honeywell Sensing and Control 3
ABSOLUTE OUTPUT at 12 Vdc excitation at 25 °C [77 °F]
XCX Output Full Scale Span, (mV)
FS Pressure Min. Typ. Max. Max.
Overpressure (psi)
5 psi 57 60 63 15
15 psi 85 90 95 45
30 psi 85 90 95 90
60 psi 85 90 95 180
100 psi 95 100 105 200
PHYSICA L DIMENSIONS for reference only mm [In]
Equivalent Circuit Pinout
1. N/C
2. +V Excitation
3. –V Output Signal
4. –V Excitation
5. – Output Signal
6. N/C
Media Compatibility
Media Compatibility, Wetted Materials
(Apply clean, dry gases only)
P1 Port: Front side of silicon diaphragm, silicone gel
passivation, glass filled nylon alumina.
P2 Port: Silicon diaphragm, glass filled nylon, and
alumina ceramic. Port not used for absolute
devices
Silicon Pressure Sensors
Compensat ed Pressure Sensing XCX, XCXL Series
Sensing and Contr ol
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
008047-2-EN IL 50 GLO 1004 Printed in USA
Copyright 2004 Honeywell International Inc. All Rights Reserved.
CPC/CPCL/CPX/CPXL SERIES ORDER GUIDE
Note:1. Gage and Differential use “D” suffix. Product is the same. Not all combinations are available.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com