1-62 ISO – Wide Temperature R ange
Model 82 UltraStable
316L SS Pressure Sensor
High Performance, 19 mm
0-100 mV Output
Absolute and Gage
Low Pressure
Hydraulic Controls
Process Control
Oceanography
Refrigeration/Compressors
Pressure Transmitters
Level Systems
FEATURES
O-Ring Flush Mount
–20°C to +85°C Compensated
Temperature Range
±0.1% Pressure Non-linearity
±1.0% Interchangeable Span
(provided by gain set resistor)
Solid State Reliability
Low Power
STANDARD RANGES
Range psig psia
0 to 5 Contact Factory
0 to 15 ●●
0 to 30
0 to 50 ●●
0 to 100
0 to 300 ●●
0 to 500
DESCRIPTION
The Model 82 is a 19 m m small profile, media compatible,
piezoresistive silicon pressure sensor packaged in a 316L
sta in l ess stee l h ou sing. Th e Mo d el 82 is d es ig n e d for O - ri n g
mounting. The sensing pack age utilizes silicone oil to transf er
pressur e fr om the 316L stainless steel di aphragm to the sensing
element.
The Model 82 i s designed for high performance, low
pressure applications. A ceramic substr ate is attached to the
packag e that contains la ser-trimmed resistors for temperature
compensation and offset correction. An additional laser-
trimmed resistor is included which can be used to adjust an
ex te rn a l d iff e ren t ia l ampli f ie r an d p rovide sp a n
inte rchangeability to within ±1%.
Sensors with threaded pressure fit tings, weldable flush
sen so rs and hi gh pres su re st a in l ess stee l sen s o rs are also
available. Please contact the factory for more information.
DIMENSIONS
316L SS Pressure Sensor Model 82 UltraStable
ISO Wide Temperature Range
June 2001
PERFORMANCE SPECIFICATIONS
All parameters specified at 1.5mA and at 25°C, after 10 second warm up, unless otherwise indicated. Unless specifically indicated, only those parameters
indicated as tested are verified on each part. Parameters are specifie d f or the compensated version only.
Notes
1. For amplified output circuits see application note TN-003.
2. Measured at vacuum for absolute (A), ambient for gage (G).
3. Best fit straight line.
4. Over the temperature range –20°C to +85°C with respect to +25°C.
5. 15 psi range sensors have an offset temperature error of ±0.75%
(Max) from –20°C to +85°C.
6. Guarantees output/input ratiometricity.
7. Load resistance to reduce measurement errors due to output loading.
8. Between case and sensing element.
9. Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
10. For gage units used at pressures below atmosphere, the span accuracy
is not guaranteed.
ORDERING INFORMATION
CONNECTIONS
APPLICATION SCHEMATIC
PARAMETERS MIN TYP MAX UNITS NOTES
Full Scale Output Span 75 100 150 mV 1
Zero Pressure Output (Offset) –1 0 1 mV 2
Pressure Non Linearity –0.10 0.10 ±% Span 3
Pressure Hysteresis –0.05 0.02 +0.05 ±% Span
Repeatability 0.02 ±% Span
Input Resistance 2000 3500 4500
Output Resistance 4000 25000
Temperature Error - Span (–20 to +85°C) 0.75 +0.75 % Span 4
Temperature Error - Offset (–20 to +85°C) –0.5 +0.5 % Span 4, 5
Thermal Hysteresis - Span 0.05 % Span 4
Thermal Hysteresis - Offset 0.05 % Span 4
Long Term Stability - Span 0.1 ±% Span/year
Long Term Stability - Offset 0.1 ±% Span/year
Supply Current 0.5 1.5 2.0 mA 6
Output Load Resistance 5 M7
Insulation Resistance (50 VDC) 50 M8
Pressure Overload 3X Rated
Compensated Temperature Range –20°C to +85°C 9
Operating Temperature Range –40°C to +125°C 9
Storage Temperature Range –50°C to +125°C 9
Media - Pressure Port Liquids and Gases compatible with 316L Stainless Steel
Media - Reference Port Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and
316L Stainless Steel
Weight 12 g
PAD/CONDUCTOR NO FUNCTION
1+OUT
2-EX
3+EX
4-OUT
5GAIN
6GAIN
LEADER Electronic Co., Ltd - 116, Jianghuali, Jianghua Road, Jiangmen City, GD, PRC
Tel: + 86 750 3101711, 3379183 Fax: + 86 750 3388669 Website: www.leadersensors.com - e-mail: leader@leadersensors.com