SP-480 480W Single Output with PFC Function series Features : Universal AC input / Full range Built in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan High power density 5.18w/in Low profile:43mm thickness Built-in remote ON-OFF control Built-in remote sense function Active AC surge current limiting 3 years warranty 3 Bauar t gepruft Sicherheit egel ma ge o s od g be wac SPECIFICATION www. tuv.com ID 2000000000 MODEL SP-480-3.3 SP-480-5 SP-480-12 SP-480-15 SP-480-24 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 85A 85A 40A 32A 20A 10A CURRENT RANGE 0 ~ 85A 0 ~ 85A 0 ~ 43A 0 ~ 35A 0 ~ 22A 0 ~ 11A RATED POWER 280.5W 425W 480W 480W 480W 480W Note.5 280.5W 425W 516W 525W 528W 528W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 150mVp-p 150mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 2.0% 10.8 ~ 13.2V 1.5% 13.5 ~ 18V 1.5% 22 ~ 27.6V 1.0% 41~ 56V 1.0% PEAK LOAD(10min.) OUTPUT LINE REGULATION 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 80ms/230VAC 88% 89% HOLD UP TIME (Typ.) VOLTAGE RANGE 18ms/230VAC Note.6 85 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 6.5A/115VAC 3.5A/230VAC 20A/115VAC <2mA / 240VAC 40A/230VAC OVERLOAD FUNCTION OVER VOLTAGE 85% 85% 87 ~ 103A 87 ~ 103A 45.15 ~ 58.05A 36.75 ~ 47.25A 23.1 ~ 29.7A Protection type : Constant current limiting, recovers automatically after conditions is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V 28.8 ~ 33.6V Protection type : Shut down o/p voltage, re-power on to recover 11.55 ~ 14.85A 57.6 ~ 67.2V 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 7) EMC EMISSION NOTE PF>0.98/115VAC at full load 79% OVER TEMPERATURE Note.4 Shut down o/p voltage, recovers automatically after temperature goes down REMOTE CONTROL RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off -20 ~ +60 (Refer to "Derating Curve") WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY OTHERS 18ms/115VAC at full load 120 ~ 370VDC FREQUENCY RANGE LEAKAGE CURRENT PROTECTION 2500ms, 80ms/115VAC at full load ND INPUT NR 2.9 ~ 3.6V VOLTAGE TOLERANCE Note.3 2.0% SP-480-48 I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:Short EMC IMMUNITY MTBF I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), light industry level, criteria A 120.5K hrs min. MIL-HDBK-217F (25) DIMENSION PACKING 278*127*43mm (L*W*H) 1.7Kg; 6pcs/11.3Kg/0.67CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. TSW1: Detect on heatsink of power transistor. TSW2: Detect on heatsink of output diode. 5. 33% Duty cycle maximum within every 30 minute. Average output power should not exceed the rated power. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:SP-480-SPEC 2018-01-04 SP-480 480W Single Output with PFC Function Mechanical Specification Case No. 929A 216 series Unit:mm 31 21 36 33.5 19 CN51 2 5 14 ADJ. 4-M4 9 Air flow direction 8 89 127 6 5 60 11 7 9.25 4 3 2 11.5 1 1.5 25.4 43 18 max. 216 278 Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4~6 7~9 NR Terminal Pin No. Assignment : 31 8.8 8-M4 L=6(Both Sides) Connector Pin No. Assignment (CN51) : HRS DF11-6DP-2DS or equivalent Assignment -V +V Pin No. 1 2 3 Assignment GND RC-S Pin No. 4 5 6 Assignment N.C. RC+ +S Mating Housing Terminal HRS DF11-6DS or equivalent HRS DF11-**SC or equivalent ND Block Diagram fosc : 100KHz FAN ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & P.F.C. +S RECTIFIERS & FILTER POWER SWITCHING +V -V (GND) -S FG O.L.P. O.T.P. DETECTION CIRCUIT PFC/PWM CONTROL O.V.P. RC+ RC- Derating Curve Static Characteristics 100 100 90 1 80 80 2 1 Others 70 2 3.3,5V Only LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 (HORIZONTAL) 60 50 40 85 90 115 120 140 165 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:SP-480-SPEC 2018-01-04 SP-480 480W Single Output with PFC Function series Control Terminal Instruction Manual Remote Sensing Remote Control Power on : V is 0 ~ 0.8V +S -S V 36 25 14 +V + LOAD - -V RC+ Power off : V is 4 ~ 10V 36 25 14 RC- 9 8 9 8 + 7 LOAD 6 - 5 7 6 5 4 4 3 3 2 2 1 1 ND NR File Name:SP-480-SPEC 2018-01-04