Electrical rating (depending on version) 21 (8) A 250 V~ 25E3
16 (4) A 400 V~ 50E3
8 (8) A 250 V~ 50E3
21 A 125 VAC 1 HP
21 A 250 VAC 2 HP
Version DIN 41635 A
Actuating force series 1004 0,2 ... 1,8 N
series 1005 1,0 ... 4,2 N
series 1006 0,3 ... 4,2 N
Mechanical life endurance< 3 mm 10E6
"3 mm and lever versions 5E6
Electrical life endurance electrical rating-dependent
Contact resistance (new state) < 100 m#
Insulation resistance (new state) >100 M#(500 V DC between the
open contacts)
High voltage resistance (new state) < 3 mm 750 V (between the
"3 mm 1250 V open contacts)
3750 V (reinforced insulation)
Bounce time < 10 ms
Resistance to tracking PTI 250
Contact gap < 3 mm (µ) or "3 mm
Ambient temperature -40 °C ... +100 °C no condensation
Storage temperature -40 °C ... +80 °C
Flammability housing UL 94 V-0
actuator UL 94 V-0 / V-2
Heat and fire-resistance 850 °C (category D)
Material housing / actuator duroplast or PA
optional actuator chrome-nickel steel
optional actuator roller PA
Contacts Ag/Ag resp. gold-plated
Terminals silver-plated
Solderability of terminals duroplast-housing max. 350 °C, 5 sec.
thermoplast-housing max. 350 °C, 2-3 sec. (no pressure
on the terminals when
soldering by hand)
Approval marks r a
Suitable for appliances of protection class II. Required air and creepage distances
within the appliances have to be observed.