R72G, R72R EXCELON(R)72 Pressure Regulator 1/4", 3/8" Port Sizes EXCELON design allows in-line installation or modular installation with other Excelon 72 products Full flow gauge ports Balanced valve design for optimum pressure control Push to lock adjusting knob with tamper resistant accessory R72R reverse flow option Technical Data Ordering Information Fluid: Compressed air Maximum pressure: 20 bar (290 psig) Operating temperature*: -20 to +65C (0 to +150F) See Ordering Information on the following pages. * Air supply must be dry enough to avoid ice formation at temperatures below 2C (35F). Approximate flow at 10 bar (145 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a droop of 1 bar (15 psig) from set: 33 dm3/s (70 scfm) Gauge ports: 1/8" PTF with PTF main ports 1/8" ISO Rc with ISO Rc main ports 1/8" ISO Rc with ISO G main ports Materials: Body: Zinc Bonnet: Acetal Valve: Brass Elastomers: Nitrile Bottom plug: Acetal 1/97 ISO Symbols R72G Relieving R72G Non Relieving R72R Relieving R72R Non Relieving Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. N/AL.8.160.200.01 R72G, R72R Typical Performance Characteristics bar g psig FLOW CHARACTERISTICS PORT SIZE: 1/4" INLET PRESSURE: 10 bar g (145 psig) RANGE: 0,3 to 10 bar 8 OUTLET PRESSURE 100 6 80 60 4 40 2 20 0 0 0 0 10 20 20 40 30 60 40 80 50 100 dm3/s 120 scfm AIR FLOW Ordering Information. Models listed include unidirectional flow, ISO G threads, knob adjustment, relieving diaphragm, 0,3 to 10 bar (5 to 145 psig) outlet pressure adjustment range* without gauge. Port Size G1/4 G3/8 Model R72G-2GK-RMN R72G-3GK-RMN Flow dm3/s (scfm) 33 (70) 33 (70) Weight kg (lb) 0,36 (0.79) 0,36 (0.79) Typical flow with 10 bar (145 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set. Alternative Models R 7 2 - - Flow Type Standard Reverse flow Substitute G R Gauge With Without Substitute G N Port Size 1/4" 3/8" Substitute 2 3 Outlet Pressure Adjustment Range* 0,3 to 2 bar (5 to 30 psig) 0,3 to 4 bar (5 to 60 psig) 0,3 to 10 bar (5 to 145 psig) Substitute C F M Threads PTF ISO Rc taper ISO G parallel Substitute A B G Diaphragm Relieving Non Relieving Substitute R N Adjustment Knob T-bar Substitute K T * Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. ** Units with 17 bar (250 psig) outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th digit and S at the 12th position. N/AL.8.160.200.02 Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. 1/97 R72G, R72R Accessories Wall Mounting Bracket 4224-50 Neck Mounting Bracket 74316-50 Includes plastic panel nut O 40 mm Pressure Gauge R1/8 Connection Plastic Panel Nut 4 bar (60 psig): 10 bar (150 psig): 25 bar (360 psig): 18-013-990 18-013-989 18-013-908 1/8 PTF Connection 18-013-211 18-013-212 4248-89 Tamper Resistant Cover and Seal wire 4255-51 Seal Wire: 2117-01 Dimensions mm (inches) Panel mounting hole diameter: 40 mm (1.57") Panel thickness: 0 to 4 mm (0" to 0.16") 50 (1.97) 1/97 33 (1.31) 102 (4.03) 35 (1.38) 26 (1.01) 73 (2.88) 33 (1.31) 26 (1.01) 35 (1.38) 48 (1.89) 48 (1.89) 63 (2.48) 50 (1.97) Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. N/AL.8.160.200.03 R72G, R72R Bracket Mounting Wall Bracket Use 4 mm (5/32") screws to mount bracket to wall. Quikclamp and Quikclamp Wall Bracket Use 5 mm (3/16") screws to mount bracket to wall. 42 (1.65) 20 (0.80) 38 (1.50) Port CL 59 (2.32) 74 (2.91) 60 (2.36) 38(1.50) Port C L 12 (0.47) 51 (2.00) 18.6 (0.73) Port C L 39 (1.54) 5 (0.20) 6 (0.24) 4 (0.16) 14 (0.55) Neck Mounting for B72, R72, V72, includes plastic panel nut Use 4 mm (5/32") screws to mount bracket to wall. 38 (1.50) 49 (1.93) Bracket Kit Reference Item Wall bracket Neck mounting wall bracket Quikclamp and Quikclamp wall bracket Part Number 4224-50 74316-50 4214-52 34 (1.34) Port CL 30 (1.18) 7 (0.28) 4,4 (0.17) Port CL Service Kits Item Service kit Type Relieving Non relieving Part Number 4381-500 4381-501 Service kit includes diaphragm assembly, valve assembly, valve spring and o-rings. N/AL.8.160.200.04 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under `Technical Data'. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Water vapor will pass through these units and will condense into liquid if air temperature drops in the downstream system. Install an air dryer if water condensation could have a detrimental effect on the application. Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. 1/97