Product datasheet
Characteristics
ZMLPA1P2SW
Display & switch ZMLP - 24VDC - 4..20 mA - PNP
- window - M12
Main
Range of product OsiSense XM
Product or component type Electronic pressure sensors
Device short name ZMLP
Complementary
Display range -14.5...6000
[Us] rated supply voltage 24 V DC SELV, voltage limit: 17...33 V
Current consumption <= 50 mA
Electrical connection M12 female connector with 2 pins
M12 male connector with 4 pins
Type of output signal Analogue + discrete
Analogue output function 4...20 mA
Discrete output type PNP solid state - NO/NC programmable
Switching function Window
Maximum switching current 200 mA
Voltage drop <= 2 V
Adjustable range of switching point on
rising pressure
5...98 % of selected display range
Adjustable range of switching point on
falling pressure
2...95 % of selected display range
Minimum differential travel 3 % of selected display range
Marking CE
Front material Polyester
Housing material PBT Valox
Operating position Any position
Protection type Overload protection
Overvoltage protection
Reverse polarity
Short-circuit protection
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
May 3, 2019
1
Response time on output <= 3 ms for analog output
<= 3 ms for discrete output
Display type 4 digits 7 segments
Local signalling 1 LED yellow for light ON when switch is actuated
Response time 300 ms
Delay first up <= 100 ms
Accuracy <= - 0.1 % of the measuring range
Measurement accuracy <= 1 % of the measuring range
Display accuracy <= 1 % of the measuring range
Mechanical durability >= 10000000 cycles
Depth 42 mm
Height 77 mm
Width 41 mm
Product weight 0.103 kg
[Uimp] rated impulse withstand voltage 0.5 kV DC
Environment
Product certifications cULus
EAC
Standards EN/IEC 61000-6-2
EN/IEC 61000-6-4
UL 508
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -30...80 °C
IP degree of protection IP65 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
IP69K conforming to DIN 40050
Vibration resistance 5 gn at 10...2000 Hz conforming to EN/IEC 60068-2-6
Shock resistance 25 gn conforming to EN/IEC 60068-2-27
Electromagnetic compatibility Immunity to conducted RF disturbances at 10 V, 0.15...80 MHz conforming to EN/IEC 61000-4-6
Surge immunity test at 1 kV conforming to EN/IEC 61000-4-5
Electrical fast transient/burst immunity test at 2 kV conforming to EN/IEC 61000-4-4
Susceptibility to electromagnetic fields at 10 V/m, 80...2000 MHz conforming to EN/IEC 61000-4-3
Electrostatic discharge immunity test at 8 kV air, 4 kV contact conforming to EN/IEC 61000-4-2
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1406 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information
2