Response time on output <= 3 ms for analog output
<= 3 ms for discrete output
Display type 4 digits 7 segments
Local signalling 1 LED yellow for light ON when switch is actuated
Response time 300 ms
Delay first up <= 100 ms
Accuracy <= - 0.1 % of the measuring range
Measurement accuracy <= 1 % of the measuring range
Display accuracy <= 1 % of the measuring range
Mechanical durability >= 10000000 cycles
Depth 42 mm
Height 77 mm
Width 41 mm
Product weight 0.103 kg
[Uimp] rated impulse withstand voltage 0.5 kV DC
Environment
Product certifications cULus
EAC
Standards EN/IEC 61000-6-2
EN/IEC 61000-6-4
UL 508
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -30...80 °C
IP degree of protection IP65 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
IP69K conforming to DIN 40050
Vibration resistance 5 gn at 10...2000 Hz conforming to EN/IEC 60068-2-6
Shock resistance 25 gn conforming to EN/IEC 60068-2-27
Electromagnetic compatibility Immunity to conducted RF disturbances at 10 V, 0.15...80 MHz conforming to EN/IEC 61000-4-6
Surge immunity test at 1 kV conforming to EN/IEC 61000-4-5
Electrical fast transient/burst immunity test at 2 kV conforming to EN/IEC 61000-4-4
Susceptibility to electromagnetic fields at 10 V/m, 80...2000 MHz conforming to EN/IEC 61000-4-3
Electrostatic discharge immunity test at 8 kV air, 4 kV contact conforming to EN/IEC 61000-4-2
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1406 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information