www.sylvania.com QUICKTRONIC(R) PROStart(R) T5HO Universal Voltage <10% THD Electronic T5HO Fluorescent Programmed Rapid Start Systems Normal Ballast Factor Professional Series Lamp / Ballast Guide 54W T5 - PENTRON HO 1-lamp QTP1x54T5HO/UNV 2-lamp QTP2x54T5HO/UNV Also operates: FT55DL, FT50DL, FPC55, L58T8 (R) T5HO PSN 39W T5 - PENTRON HO 1-lamp QTP1x39-24T5HO/UNV 2-lamp QTP2x39-24T5HO/UNV 24W T5 - PENTRON HO 1-lamp QTP1x39-24T5HO/UNV 2-lamp QTP2x39-24T5HO/UNV Also operates: FT36DL, FT24DL, CF24DF, CF36DF, FPC40, FPC22 80W T5 - PENTRON HO 1-lamp QTP1x80T5HO/UNV Also operates: FT80DL SYLVANIA QUICKTRONIC PHO operates PENTRON HO, PENTRON HO Circline, and DULUX(R) L T5 lamps with full lumen output and optimal system performance. SYSTEM PHO provides nearly twice the light output (188%) of T8 systems, with the same number of lamps, allowing many new design options. One lamp fixtures can now be used in place of two lamp models. SYSTEM PHO ballasts contain QUICKSENSE ballast technology, a patented circuitry designed to shut down the system reliably and safely when lamps reach end-of-life. Setting the standard for quality, SYSTEM PHO is also covered by our QUICK 60+(R) warranty, the first and most comprehensive system warranty in the industry. SYSTEM PHO is available in one and two lamp models to cover a wide range of applications. Two lamp models can be wired for one lamp operation. Key System Features * * * * * * * * * * * * Universal voltage (120-277V) Low-profile (0.86" High) 100% Ballast factor QUICKSENSE(R) ballast technology (end-of-lamp-life sensing) PROStart programmed rapid start UL type CC rated Min. Starting Temp: * 0F/-18C * -20F/-29C for QTP 2x54T5HO Models Operates at >40 Khz to reduce potential interference with infrared control systems High power factor Low harmonic distortion Lightweight UL, CSA, FCC Application Information SYLVANIA QUICKTRONIC PHO is ideally suited for: * Commercial & retail * Hospitality & institutional * New construction * Direct lighting * Indirect lighting * Surface mount 62 * Cove lighting System Information System PHO operates from 120V through 277V, 50 or 60Hz, eliminating "wrong voltage" wiring errors and reducing the number of models in inventory by half. PROStart ballasts provide optimum starting conditions to provide up to 100,000 switching cycles for use on occupancy sensors and building control systems. QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the glass wall, and uses dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICKSENSE ballast technology will auto reset when the end-of-life lamps are replaced with new ones. The two lamp unit can be wired for one lamp operation, allowing for an additional 50% reduction in inventory model numbers. Input Power (W) Initial System Lumens System Efficacy LPW F40T12 - E.S. Magnetic Ballast (4-lamp) F34T12 - E.S. Magnetic Ballast (4-lamp) 172 144 11590 9500 67 66 FO32T8/XP - QT4x32IS (4-lamp) FP54T5HO - QTP2x54T5HO/UNV PSN (2-lamp) 114 121 10800 10000 95 83 FO32T8/XP - QT2x32IS (2-lamp) FP54T5HO - QTP1x54T5HO/UNV PSN (1-lamp) 59 62 5400 5000 92 81 System Type SYSTEM PHO comes in a 22H x 30W mm profile, and PENTRON lamps are designed to provide peak performance at 35C fixture ambient, allowing for smaller and more innovative fixtures. A complete OSRAM SYLVANIA System Performance Guide showing performance characteristics of lamps and ballasts is available upon request. Normal Ballast Factor SPECIFICATION DATA Catalog # Date Project Prepared by Type T5HO PROStart (R) Professional Series Comments Performance Guide Universal Voltage (120-277V) Item Number 49101 UNV Input Current (AMPS) Description Lamp Type Rated1 Ballast1 Input1 System Lumens No. of Factor System1 Mean1 Power Efficacy (lm) Lamps (BF) Lumens Lumens (Watts) (lm/W) BEF2 QTP 1x39-24T5HO/UNV PSN 0.23/0.10 FP24T5HO 2000 1 1.00 2000 1860 29 70 3.45 QTP 2x39-24T5HO/UNV PSN 0.47/0.20 FP24T5HO 2000 2 1 1.00 1.00 4000 2000 3720 1860 55/54 29 73/74 70 1.85 3.45 QTP 1x39-24T5HO/UNV PSN 0.36/0.15 FP39T5HO 3500 1 1.00 3500 3255 42 83 2.38 QTP 2x39-24T5HO/UNV PSN 0.76/0.32 FP39T5HO 3500 2 1 1.00 1.00 7000 3500 6510 3255 85/83 42 82/84 83 1.20 2.38 QTP 1x54T5HO/UNV PSN 0.51/0.21 FP54T5HO 5000 1 1.00 5000 4650 62/60 81/83 1.67 QTP 2x54T5HO/UNV PSN 1.00/0.43 FP54T5HO 5000 2 1 1.00 1.00 10000 5000 9300 121/118 83/85 4650 61 82 0.85 1.64 (49150)* QTP 1x80T5HO/UNV PSN 0.74/0.32 FP80T5HO FT80T5DL 7000 6000 1 1 1.00 1.00 7000 6000 6510 5580 1.11 1.11 Data based upon SYLVANIA PENTRON(R) lamps shown. QUICKTRONIC(R) PHO ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. (49100)* 49111 (49110)* 49101 (49100)* 49111 (49110)* 49121 (49120)* 49131 (49130)* 78 67 1: At 35C lamp ambient temperature. 2: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). *(Item Number) = Item Number/NAED in parentheses are models with leads/wires. Ballast with leads/wires contains 10 pieces each. Ballast without leads contain 20 pieces each. Black White Black BALLAST BALLAST White Red LAMP Red Yellow LAMP Blue LAMP 1 LAMP Blue 2 LAMP Height QUICKTRONIC products are covered by our QUICK 60+(R) warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin. Mounting Length Length Width 49131 QTP 2 x 54 T5HO/UNV PSN 4 Operation below 50F (10C) may affect light output or lamp operation - see "Low Temp. Starting" definition. Remote red leads up to 18 feet. Keep blue leads <10 feet. System Life / Warranty Product Weight: 1L: 0.68 lbs each (approx) 2L: 0.88 lbs each (approx) Item Number UL Listed Class P, Type 1, Outdoor, Type CC CSA Certified 70C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet 3 3 Data based on PENTRON HO lamp types for primary ballast application. See the Sylvania QUICKTRONIC(R) Electronic Ballast Technology and Specification Guide (ECSELECTRONIC) for Pentron Circline, DULUX(R) L/F and other combinations. Dimensions: Model QTP1x39-24T5HO/UNV PSN, QTP2x39-24T5HO/UNV PSN, QTP1x54T5HO/UNV PSN and QTP1x80T5HO/UNV PSN enclosure size: Overall: 360mm L x 30mm W x 22mm H Mounting: 349mm Model QTP2x54 T5HO/UNV PSN enclosure size: Overall: 425mm L x 30mm W x 22mm H Mounting: 415mm Wiring: Push-in connectors Use 18AWG solid copper wire only Starting Method: Programmed Rapid Start Ballast Factor: 1.00 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp: 0F (-18C) minimum4 -20F (-29C) Starting for QTP2x54T5HO Models Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: 10% of 120-277V rated line (108-305V) T5HO PSN 90 90 Specifications3 Starting/Ballast Factor QUICKTRONIC PROFESSIONAL Line Voltage (120-277V) Number of Lamps (1, 2) Primary Lamp Wattage OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com 63 Specifications subject to change without notice.