CREAT BY ART
High efficiency, low VF
High current capability
High reliability
High surge current capability
Low power loss
SFA100XG = Specific Device Code
G = Green Compound
Y = Year
WW = Work Week
Maximum Ratings and Electrical Characteristics
Rating at 25 ℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
VRRM 50 100 150 200 300 400 500 600 V
VRMS 35 70 105 140 210 280 350 420 V
VDC 50 100 150 200 300 400 500 600 V
Trr nS
Cj pF
RθjC OC/W
TJOC
TSTG OC
Note 3: Measured at 1 MHz and Applied Reverse Voltage of 4.0V D.C.
Case: TO-220AC Molded plastic
Epoxy: UL 94V-0 rate flame retardant
SFA
1008G
Green compound with suffix "G" on packing
code & prefix "G" on datecode
Marking Diagram
SFA
1005G SFA
1006G SFA
1007G
A
Type Number Symbol SFA
1001G SFA
1002G SFA
1003G SFA
1004G
10
Peak Forward Surge Current, 8.3 ms Single Half Sine-
wave Superimposed on Rated Load (JEDEC method)
Unit
Weight: 1.9 grams
Typical Thermal Resistance
uA
IFSM
IF(AV)
125
A
SFA1001G - SFA1008G
10.0AMPS Glass Passivated Super Fast Rectifier
TO-220AC
Dimensions in inches and (millimeters)
Features
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
Maximum Repetitive Peak Reverse Voltage
Polarity: As marked
High temperature soldering:
260℃/10 seconds/.16",(4.06mm) from case
Terminals: Pure tin plated, lead free, solderable
per MIL-STD-202, Method 208 guaranteed
For use in low voltage, high frequency inventor,
Free wheeling, and polarity protection application
Mechanical Data
Version:G11
- 65 to + 150
Typical Junction Capacitance (Note 3)
Note 2: Reverse Recovery Test Conditions: I F=0.5A, IR=1.0A, IRR=0.25A
Note 1: Pulse Test with PW=300 usec, 1% Duty Cycle
Operating Temperature Range
Storage Temperature Range - 65 to + 150
3.5
70 50
Maximum Reverse Current @ Rated VR TA=25 ℃
T A=125 ℃IR
10
400
Maximum Reverse Recovery Time (Note 2) 35
1.7 V
Maximum Instantaneous Forward Voltage (Note 1)
@ 10 A VF0.975 1.3
Pb
RoHS
COMPLIANCE
RoHS
COMPLIANCE