5.7" (145mm) DC Bypass Blower Blower Data Unit of Measure 1200 WATT, 240 VOLT Part Number High Flow Standard Flow Ultra Flow 117416 M* 119152 M* 119154 M* 117415 E* 119151 E* 119153 E* 119155 E* 1 50 2 91 1 33 Stages Vacuum, Max. (Sealed Vacuum) in. H2O 3 135 Pressure, Max. (Sealed Pressure) mBar in. H O 335 144 124 54 226 97 82 39 Flow Rate, Max. (Open Flow) mBar CFM 357 82 134 190 241 156 97 307 Inlet/Outlet Diameter L/sec inches 39 1.25 90 1.75 74 1.75 145 2.75/2.50 (Dimension "D" above) Length (Dimension "I" above) mm inches 31.75 2.12 44.45 .47 44.45 1.53 69.85/63.50 .70 Length (Dimension "L" above) mm inches 53.85 6.87 11.94 5.11 38.86 6.35 17.78 5.47 mm 174.50 128.77 161.29 138.94 2 Typical Performance Points Air Flow Pressure 0 CFM 20 CFM in. H2O in. H2O 144.3 129.1 54.0 53.9 97.0 92.5 39.2 38.0 40 CFM 60 CFM in. H2O in. H2O 102.9 60.8 51.1 47.0 85.8 75.9 37.5 35.3 80 CFM 100 CFM in. H2O in. H2O 10.8 43.2 37.0 62.3 40.5 33.5 31.4 120 CFM 140 CFM in. H2O in. H2O 29.4 22.3 32.1 15.0 28.0 25.4 160 CFM 180 CFM in. H2O in. H2O 14.2 200 CFM 220 CFM in. H2O in. H2O 16.1 13.1 240 CFM 260 CFM in. H2O in. H2O 10.0 7.4 280 CFM 300 CFM in. H2O in. H2O 4.3 1.0 *These part numbers are available through AMETEK Rotron distributors. NOTES: * Nominal input voltage: 240 Volts AC RMS +/- 10%, 50/60Hz * Input current: 5 amps AC RMS maximum * Temperature: Working Air: 0C to 50C, Ambient Air: 0C to 50C, Storage Air: -40C to 85C * Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max. * Maximum Approximate Weight: 6 lbs. 40 21.5 18.5 5.7" (145mm) DC Bypass Blower 1200 WATT, 240 VOLT * Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (User Supplied), 0 to 10 Volts DC Nominal, 10mA Maximum, 3 to 15 volts DC Maximum. Access to sensitivity adjustment for 0-10 VDC speed control. (Ref. pin connection) M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access to speed adjustment. * Regulatory Agency Certification: T.U.V. Rheinland Bauart Certification* is qualified per EN60950 under License No. 9571008; Underwriters Laboratories, Inc. is qualified per UL507 under File E 94403; Canadian Standards Association is qualified per C22.2#113 under File LR 43448. * Miscellaneous: Intake & exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign particles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly. IEC 801 testing has been completed, and specific data can be provided upon request. Mating harness available upon request. Refer to (page 84) for specific part numbers. This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions, data is corrected to 0.075 lb./ft3 air density (29.92" Hg @ 70 F.). Actual performance will vary depending on the operating environment and application. AMETEK Rotron products are not designed for use with volatile, hazardous or corrosive gases. Blower housings are not sealed, slight air/gas leakage will occur. AMETEK Rotron products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications contact AMETEK Rotron Marketing and Sales. 41