FEATURES
Adjustable resistor or voltage divider
High temperature silicon coating
Can be used to quickly obtain odd resistance
values
One or more adjustable lugs can be provided
for voltage divider applications
Can be used as multi-tap resistor
Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are RoHS-compliant and/or parts that are non-RoHS-compliant. For example, parts
with lead (Pb) terminations are not RoHS-compliant. Please see the information/tables in this datasheet for details.
Note
(1) Short time overload is rated without adjustable lug attached.
Available
Available
Available
Available
STANDARD ELECTRICAL SPECIFICATIONS
GLOBAL
MODEL HISTORICAL MODEL POWER RATING P25 °C
W
RESISTANCE RANGE
TOLERANCE
± %
WEIGHT (typical)
g
HLA012 HLA-12 12 1.0 to 10K 5 6.69
HLA020 HLA-20 20 1.0 to 18K 5 12.57
HLA025 HLA-25 25 1.0 to 23K 5 20.72
HLA026 HLA-26 26 1.0 to 31K 5 15.34
HLA050 HLA-50 50 1.0 to 57K 5 42.08
HLA051 HLA-51 51 1.0 to 95K 5 51.96
HLA060 HLA-60 60 1.0 to 74K 5 65.64
HLA065 HLA-65 65 1.0 to 130K 5 64.82
HLA080 HLA-80 80 1.0 to 111K 5 121.58
HLA100 HLA-100 100 1.0 to 132K 5 91.37
HLA120 HLA-120 120 1.0 to 180K 5 183.82
HLA130 HLA-130 130 1.0 to 192K 5 192.36
HLA160 HLA-160 160 1.0 to 249K 5 245.86
HLA175 HLA-175 175 1.0 to 398K 5 250.80
HLA225 HLA-225 225 1.0 to 337K 5 309.97
TECHNICAL SPECIFICATIONS
PARAMETER UNIT HLA RESISTOR CHARACTERISTICS
Temperature Coefficient ppm/°C ± 30 for 10 and above; ± 50 for 1 to 9.9 ; ± 90 for 0.1 to 0.99
Short Time Overload (1) - 10 x rated power for 5 s
Maximum Working Voltage V (P x R)1/2
Operating Temperature Range °C -55 to +350
GLOBAL PART NUMBER INFORMATION
Global Part Numbering example: HLA22507Z200R0JJ
GLOBAL
MODEL
TERMINAL
DESIGNATION
TERMINAL
FINISH VALUE TOLERANCE PACKAGING SPECIAL
HLA225
(see “Standard
Electrical
Specifications”
table above for
additional P/N’s
02
05
06
07
14
15
E = Lead (Pb-free) R = decimal
K = thousand
10R00 = 10.0
1K000 = 1 k
J = ± 5.0 %
K = ± 10.0 %
E = lead (Pb)-free skin pack (dash number)
(up to 2 digits)
from 1 to 99
as applicable
Z = tin / lead
N = nickel
J (2) = skin pack (J01)
Note
(2) Tin / lead for type “Z”, lead (Pb)-free for
type “N”
Historical Part Numbering example: HLA-225-07Z 200 5 % J01
HLA-225 07Z 200 5 % J01
HISTORICAL MODEL TERMINAL/FINISH RESISTANCE VALUE TOLERANCE PACKAGING
LA22507Z200R0JJH Z
HLA
www.vishay.com Vishay Dale
Product is End of Life Mar-2016 and Replaced by AST
Revision: 02-May-16 2Document Number: 30211
For technical questions, contact: ww2dresistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
DIMENSIONS
Note
(1) Brackets and sliders are available for mounting HLA series resistors - see Mounting Hardware.
ADJUSTABLE LUGS
The coating protects the resistance wire from shifting and
shorting to other turns during adjustment. However, the
following three steps should always be taken whenever
adjustments are made:
1. Turn off power to avoid possible operator injury and
damage to the unit.
2. Loosen adjustable lug until it will slide completely free,
without touching the exposed wire.
3. When adjustment point has been selected, retighten lug
only enough to assure a firm contact, do not tighten
beyond this point. Failure to follow these three steps in
order can result in damage to the resistor.
TERMINAL DIMENSIONS
TERMINAL FINISH
“E” Finish - 100 % Sn coated steel. “Z” Finish - 60/40 Sn/Pb
coated steel. “N” Finish - Nickel coated steel. Finish for
terminal style 14 and 15 is limited to nickel plated steel (N).
MOUNTING HARDWARE
Mounting Hardware is available for HLA resistors, see
“HL Brackets and Sliders” datasheet for more information:
www.vishay.com/doc?30279.
MATERIAL SPECIFICATIONS
Element: copper-nickel alloy or nickel-chrome alloy,
depending on resistance range
Core: ceramic, steatite
Coating: special high temperature silicone
Standard Terminals: model “E” terminals are tinned steel
Terminal Bands: steel
Part Marking: Dale, model, wattage, value, tolerance, date
code
DERATING
GLOBAL
MODEL
DIMENSIONS in inches [millimeters]
A
(MAX.)
CORE DIMENSIONS TERMINAL
SETBACK
± 0.031
[0.79]
DISTANCE
BETWEEN
TERMINALS
(REF.)
TERMINAL
DESIGNATION
SLIDER
MODEL
NUMBER
(1)
BRACKE
T
TYPE (1)
LENGTH
± 0.063
[1.59]
O.D.
I.D.
± 0.031
[0.79] STANDARD OPTIONAL
HLA012
0.406
[10.32]
1.750
[44.45]
0.313
[7.94]
0.188
[4.76]
0.094
[2.38] 1.187 05Z 14 N 70 101, 204,
301
HLA020
0.563
[14.29]
2.000
[50.80]
0.438
[11.11]
0.313
[7.94]
0.094
[2.38] 1.437 02Z 14 N 71 101, 203,
301
HLA025
0.688
[17.46]
2.000
[50.80]
0.563
[14.29]
0.313
[7.94]
0.094
[2.38] 1.312 06Z 15 N 72 101, 203,
301
HLA026
0.563
[14.29]
3.000
[76.20]
0.438
[11.11]
0.313
[7.94]
0.094
[2.38] 2.437 02Z 14 N 71 101, 203,
301
HLA050
0.688
[17.46]
4.000
[101.60]
0.563
[14.29]
0.313
[7.94]
0.094
[2.38] 3.312 06Z 15 N 72 101, 203,
301
HLA051
0.906
[23.02]
3.500
[88.90]
0.750
[19.05]
0.500
[12.70]
0.125
[2.38] 2.75 06Z 15 N 73 102, 206,
303
HLA060
0.906
[23.02]
4.000
[101.60]
0.750
[19.05]
0.500
[12.70]
0.125
[2.38] 3.250 06Z 15 N 73 102, 206,
303
HLA065
0.906
[23.02]
4.500
[114.30]
0.750
[19.05]
0.500
[12.70]
0.125
[2.38] 3.750 06Z 15 N 73 102, 206,
303
HLA080
1.313
[33.34]
4.000
[101.60]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 2.812 07Z 15 N 74 103, 205,
303
HLA100
0.906
[23.02]
6.500
[165.10]
0.750
[19.05]
0.500
[12.70]
0.125
[2.38] 5.750 06Z 15 N 73 102, 206,
303
HLA120
1.313
[33.34]
6.000
[152.40]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 4.812 07Z 15 N 74 103, 205,
303
HLA130
1.313
[33.34]
6.500
[165.10]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 5.312 07Z 15 N 74 103, 205,
303
HLA160
1.313
[33.34]
8.000
[203.20]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 6.812 07Z 15 N 74 103, 205,
303
HLA175
1.313
[33.34]
215.90
[8.500]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 7.312 07Z 15 N 74 103, 205,
303
HLA225
1.313
[33.34]
10.500
[266.70]
1.125
[28.58]
0.750
[19.05]
0.219
[5.56] 9.312 07Z 15 N 74 103, 205,
303
A
(Includes Coating
and
Terminal Band)
DIMENSION TERMINAL STYLE
02 05 06 07 14 15
A0.188
[4.76]
0.188
[4.76]
0.250
[6.35]
0.375
[9.53]
0.188
[4.76]
0.250
[6.35]
B0.406
[10.32]
0.438
[11.118]
0.563
[14.29]
0.625
[15.88]
0.563
[14.29]
0.594
[15.08]
C0.093
[2.36]
0.104
[2.64]
0.166
[4.22]
0.173
[4.39]
0.050
[1.27]
0.065
[1.65]
D0.020
[0.51]
0.020
[0.51]
0.020
[0.51]
0.020
[0.51]
0.020
[0.51]
0.031
[0.79]
Styles 14 and 15 B
D
A
C
B
D
C
A
Style 02
thru 07
AMBIENT TEMPERATURE IN °C
120
100
80
60
40
20
0
RATED POWER IN %
25
- 65 - 50 0 50 350250150
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 01-Jan-2021 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2021 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED