N
13-3
PAGE
Introduction ..............................................................................................................4
General.....................................................................................................................5
Finder guide...........................................................................................................6-8
N 50 Ξ©
Interface....................................................................................................................9
Characteristics...................................................................................................10-11
Straight plugs ....................................................................................................12-13
Right angle plugs...............................................................................................14-15
Straight jacks.....................................................................................................15-17
Flange mount, straight jacks..............................................................................17-19
Bulkhead mount, straight jacks........ ... ... .................... ................... .................... .19-21
Receptacles.......................................................................................................22-24
In series adapters...................................................................................................25
Caps.......................................................................................................................26
Accessories ............................................................................................................27
Cable assemblies..............................................................................................29-35
N 75 Ξ©
Interface..................................................................................................................36
Characteristics........................................................................................................37
Straight plugs .........................................................................................................38
Right-angle plugs....................................................................................................39
Straight jacks..........................................................................................................40
Flange mount, straight jacks...................................................................................41
Bulkhead mount, straight jacks........ ... ... .................... ................... .................... ... ...41
Receptacles & adapters ............... ................... ... .................... ................... .............42
Panel drilling...........................................................................................................43
Assembly instructions........................................................................................44-65
CONTENTS
13-4
N
Radiall offers a wide range with a standard plating finish : BBR (Bright
Bronze Radiall) = high performance non magnetic alloy.
β€’FULL CRIMP MODELS
A fast and reliable attachment system that can be easily achieved in a field
environment, with minimum easy-to-use tooling (including models for 2 and
2.6 mm dia cables). All our full crimp connectors are single piece body.
β€’LOW INTERMODULATION CONNECTORS
Radiall maintains extensive knowledge in this field and has developed N
series connectors that are specially designed for base stations of
applications where the elimination of intermodulation products is of the
utmost importance :
- optimized for 90 0 - 18 00 M Hz b an d s (a nd ab le to w or k up to 11 GH z like
the standard models),
-IMP
3 performance = -110 dBm (- 153 dBc),
- new models for corrugated and low loss flexible cables,
- high performance non magnetic materials and platings (silver and BBR),
- new 6 flats coupling nut (18 mm), allowing high coupling torque (170 Ncm)
thanks to torque wrench,
- non slotted outer contact.
β€’VERY LOW INTERMODULATION CABLE ASSEMBLIES
For severe intermodulation conditions, we propose a range of low
intermodulation cable assemblies IMP3-125 dBm.
β€’EZ FIT CONNECTORS
Radiall introduces its new EZ fit connectors. These two piece parts
connectors are designed for a quick and easy installation in field conditions.
Connectors are simply assembled b y screwing the cable attachment and the
body on the cable to create feeders or jumpers in only 3 steps without
anticipation of the length of the cable assembly. With a very low
intermodulation level, -112 dBm, these connectors feature as well a good
moisture level, IP68.
IMPORTANT: the 50 Ξ© and the 75 Ξ© conne ctor s are NOT INTERMATEABL E, resulting in the interf ace destruc tion .
For further details, please read our: - Intermodulation application gui de (D1 032 DE)
- BBR plating application guide (D1 030 DE)
≀
INTRODUCTION
N
13-5
GENERAL
β€’Standard coaxial connectors
β€’Screw-on coupling
β€’High durability and proven strength
β€’High power rating
β€’Excellent RF performance
β€’2 ranges : N 50 Ξ©
N 75 Ξ©
APPLICABLE STANDARDS
β€’MIL-C-39012 / MIL STD 348-304
β€’CEI 169-16
β€’CECC 22210
β€’NF-C-93566
APPLICATIONS
β€’Wireless communications
β€’Civil and military radio-telecommunication
equipment
β€’Countermeasure
β€’Navy equipment
β€’Industrial applications
50 Ξ©DC - 11 GHz
75 Ξ© DC - 1.5 GHz
GENERAL
13-6
N
CABLE CONNECTORS R161 = 50 Ξ© / R162 = 75 Ξ©
Model Straight plug Intermod
straight plug Right-angle plug Intermod right-
angle plug Straight jack
cable full crimp clamp/EZ FIT solder crimp or clamp/
EZ FIT crimp and full
crimp clamp solder crimp or clamp/
EZ FIT full crimp clamp solder
2.6/50/S
(RG 316) R161 072 000
(page 12) R161 004 000
(page 12)
2.6/50/D
(RD 316) R161 072 000
(page 12)
5/50/S
(RG 58) R161 082 000
(page 12) R161 006 000
R161 010 000
(page 12) R161 182 000
(page 14) R161 157 000
(page 14) R161 237 000
(page 15) R161 206 000
(page 16)
5/50/D
(RG 142) R161 083 000
(page 12) R161 006 000
R161 010 000
(page 12) R161 083 137
(page 12) R161 183 000
(page 14) R161 157 000
(page 14) R161 183 137
(page 14) R161 238 000
(page 15) R161 206 000
(page 16)
6/75/S
(RG 59) R162 084 000
(page 38) R162 012 000
(page 38) R162 184 000
(page 39) R162 162 000
(page 39) R162 239 000
(page 40) R162 212 000
(page 40)
8/75/D
(RG 6) R162 013 000
(page 38) R162 213 000
(page 40)
10/50/S
(RG 213) R161 075 000
(page 12) R161 020 000
R161 022 000
(page 12)
R161 185 000
R161 184 000
(page 14) R161 168 000
(page 14) R161 241 000
(page 15) R161 222 000
R161 220 000
(page 16)
10/75/S
(RG 11 ) R162 075 000
(page 38) R162 017 000
(page 38) R162 185 000
(page 39) R162 168 000
(page 39) R162 241 000
(page 40) R161 222 000
R162 217 000
(page 40)
10.3/50/S
(ETHERNET) R161 076 000
(page 12)
10.3/50/S
(LMR400) R161 075 060
(page 12) R161 184 036
(page 14)
11/50/D
(RG 214) R161 088 000
(page 12) R161 020 000
R161 022 000
(page 12) R161 088 137
(page 12) R161 186 000
R161 187 000
(page 14) R161 168 000
(page 14) R161 186 137
(page 14) R161 243 000
(page 15) R161 222 000
R161 220 000
(page 16)
11/75/D
(RG 216) R162 088 000
(page 38) R162 017 000
(page 38) R162 187 000
(page 39) R162 168 000
(page 39) R162 243 000
(page 40) R161 222 000
R162 217 000
(page 40)
.141"
(RG 402) R161 052 000
(page 13) R161 051 000
(page 13) R161 152 107
(page 15) R161 227 080
(page 17) R161 226 020
(page 17)
.250"
(RG 401) R161 053 000
(page 13) R161 054 000
(page 13)
1/4" super-
flexible
corrugated R161 036 007
(page 13) R161 177 007
(page 15) R161 232 007
(page 16)
3/8" super-
flexible
corrugated R161 036 207
(page 13) R161 177 207
(page 15) R161 232 207
(page 16)
1/2"flexible
corrugated R161 091 020W
(page 13) R161 230 3 20W
(page 16)
1/2" super-
flexible
corrugated R161 037 020
(page 13) R161 177 137
(page 15) R161 232 407
(page 16)
7/8"flexible
corrugated R161 033 020W
(page 13) R161 231
020W
(page 16)
FINDER GUIDE
N
13-7
CABLE CONNECTORS R161 = 50 Ξ© / R162 = 75 Ξ©
Model Intermod
straight jack Square flange straight jack Intermod
square flange
straight jack Bulkhead straight jack (panel sealed) Intermod
bulkhead
straight jack
cable clamp/EZ FIT full crimp clamp solder clamp/EZ FIT full crimp clamp solder clamp/EZ FIT
2.6/50/S
(RG 316) R161 252 000
(page 18) R161 311 x00
(page 19) R161 321 000
R161 322 000
(page 20)
2.6/50/D
(RG 316) R161 252 000
(page 18) R161 311 x00
(page 19) R161 321 000
R161 322 000
(page 20)
5/50/S
(RG 58) R161 256 000
(page 18) R161 329 000
(page 19) R161 325 000
(page 20)
5/50/D
(RG 142) R161 283 000
(page 17) R161 256 000
(page 18) R161 329 200
(page 19) R161 325 000
(page 20)
6/75/S
(RG 59) R162 262 000
(page 41) R162 335 000
(page 41) R162 328 000
(page 41)
10/50/S
(RG 213) R161 286 000
(page 17) R161 270 000
(page 18) R161 332 000
(page 20)
10/75/S
(RG 11) R162 267 000
(page 41) R162 336 000
(page 41) R162 332 000
(page 41)
11/50/D
(RG 214) R161 286 200
(page 17) R161 270 000
(page 18) R161 332 000
(page 20)
11/75/D
(RG 216) R162 267 000
(page 41) R162 339 000
(page 41) R162 332 000
(page 41)
.085"
(RG 405) R161 335 200
(page 21)
.141"
(RG 402) R161 277 000
(page 19) R161 277 300
(page 19) R161 323 0x0
(page 21)
R161 332 200
R161 323 200
R161 336 000
(page 21)
.250"
(RG 401) R161 278 000
(page 19) R161 337 200
(page 21)
1/4" super-
flexible
corrugated R161 232 007
(page 16) R161 279 007
(page 18) R161 341 007
(page 20)
3/8" super-
flexible
corrugated R161 232 207
(page 16) R161 279 207
(page 18) R161 341 207
(page 20)
1/2" super-
flexible
corrugated R161 232 407
(page 16) R161 279 407
(page 18) R161 341 407
(page 20)
FINDER GUIDE
13-8
N
PANEL RECEPTACLES R161 = 50 Ξ© / R162 = 75 Ξ©
IN-SERIES ADAPTERS R161 = 50 Ξ© / R162 = 75 Ξ©
CAPS
Model Straight female flange Right-angle
female flange Straight male
flange Straight female bulkhead
(panel sealed or hermetical)
12.7 mm 17.5 mm 25.4 mm 25.4 mm 25.4 mm
back square square 2 holes square square square front mount rear mount
Contact with
solder pot R161 410 000
(page 22)
R161 404 xxx
R161 412 020
R161 430 020
(page 23)
R162 403 000
(page 42)
R161 653 000
(page 24) R161 440 020
R161 441 000
(page 23)
R161 570 000
R161 625 000
(page 24)
R162 570 000
(page 42)
R161 606 000
(page 24)
Extended
dielectric
contact R161 410 520
(page 22) R161 416 130
(page 23) R161 441 400
(page 23)
Flat tab
contact R161 461 000
(page 22) R161 419 020
(page 23)
Slotted
contact R161 419 300
(page 23) R161 444 037
(page 23)
Removable
contact
(universal
receptacle)
R161 418 000
(page 22)
Model Straight Straight flange Straight
bulkhead Straight slide-on Right-angle Tee
M - M
R161 703 000
(page 25)
R162 703 000
(page 42)
F - F
R161 705 000
(page 25)
R162 705 000
(page 42)
R161 715 000
(page 25)
R161 730 000
R161 753 000
(page 25)
M - F R161 791 5x0
(page 25) R161 771 000
(page 25)
F - F / M R161 780 000
(page 25)
F - F / F R161 782 000
(page 25)
Model Cord Chain Chain short- circuit
MR161 804 000
R161 805 410
(page 26)
R161 853 000
(page 26) R161 862 000
(page 26)
FR161 844 000
(page 26) R161 841 000
(page 26)
FINDER GUIDE
ATTENTION ! This guide is intended as an information and does not include all N SERIES P/N
N
13-9
IMPORTANT: the 50 Ξ© and the 75 Ξ© co nnectors are NOT INTERMATEABLE, result ing in the interf ace dest ruction
LETTER mm inch LETTER mm inch
min. max. min. max. min. max. min. max.
A 0.13 1.03 .005 .13 A 9.05 9.19 .356 .362
B 2.80 3.56 .110 .140 B 4.75 5.25 .187 .207
C 5.33 5.83 .210 .229 C 1.20 1.95 .047 .077
D 1 2 .016 .066 D 4.4 5.1 .173 .201
E 4.54 5.39 .179 .212 E 6.8 9 .268 .354
F 4.05 4.20 .159 .165 F 10.9 11.2 .429 .441
G 10.23 10.43 .403 .411 G DIA 6.98 7.02 .275 .276
H DIA 8.27 8.37 .326 .329 H DIA 8.03 8.13 .316 .320
J DIA 16.1 16.2 .634 .638 J DIA 8.53 8.73 .336 .344
K DIA 20.9 21 .823 .827 K DIA 15.65 15.85 .616 .624
L DIA 3.01 3.05 .118 .120 L DIA 3.01 3.05 .118 .120
M DIA 1.63 1.67 .064 .066
PLUG JACK
INTERFACE
50 Ξ©
All dimensions are given in mm (inch)
13-10
N
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
TEST/CHARACTERISTICS STANDARD
REFERENCE VALUES/REMARKS
Impedance 50 Ξ©
Frequency range DC - 11 GHz
V.S.W.R. (typ.) Frequency
β€’ Straight models cable group .085”
.141”
.250”
5 S + 5 D
10 S + 11 D
β€’ Right angle models 5 S + D
10 S + 11 D
1 GHz
1.03
1.03
1.03
1.05
1.04
1.04
1.04
2.5 GHz
1.03
1.05
1.03
1.06
1.05
1.05
1.1
5 GHz
1.05
1.05
1.05
1.1
1.09
1.18
1.20
11 GHz
1.08
1.08
1.07
1.16
1.2
Intermodulation product (IMP3)
β€’ Standard connectors
β€’ Intermodulation connectors
β€’ Home made intermodulation cable assemblies
- 90 dBm typ. (- 133 dBc typ. / 20W)
- 110 dBm typ. (- 153 dBc typ / 20 W)
- 125 dBm typ. (- 165 dBc typ. / 20W)
Insertion loss straight connector
right-angle connector MIL < 0.15 dB max at 10 GHz ~ < 0.05 (GHz)
< 0.15 dB max at 10 GHz ~ < 0.1 (GHz)
RF Leakage MIL - 90 dB min from 2 to 3 GHz (interface)
Insulation resistance MIL 5000 MΞ© min
Contact resistance center contact
outer contact MIL Initial
1 mΞ©
0.2 mΞ©
After tests
1.5 mΞ©
-
Working voltage in VRMS at sea level
(at 70, 000 feet) CECC
Cable 5 / 50: 850 (250)
Cable .085” / .141”: 350 (250)
Cable 10+11/50: 1400 (400)
Cable LMR 400/600: 1400 (400)
Cable .250”: 1400 (400)
Dielectric withstanding voltage in VRMS
at sea level
(at 70, 000 feet) CECC
Cable 5 / 50: 1500 (350)
Cable .085” / .141”: 1000 (350)
Cable 10/50: 2500 (600)
Cable LMR400/600: 2500 (600)
Cable .250”: 2500 (600)
RF testing voltage sea level CECC 1500 VRMS (5 MHz sine wave)
Durability CECC 500 matings
Force to engage and disengage CECC 6.6 Ncm max (.58 Inch-pounds)
Recommended coupling nut torque 40 to 60 Ncm (manual)
130 Ncm (11.45 inch pounds) (with pliers R 282 202 000)
170 Ncm (14.96 inch pounds) (with torque wrench R 282 303 020)
Proof torque CECC 170 Ncm (14.96 inch pounds)
Coupling nut retention force CECC 450 N (101.25 Lbs)
Cable retention force
CECC
Cable 5/50/S: 150 N (33.75 Lbs)
Cable 5/50/D: 200 N (48 Lbs)
Cable 10/50: 300 N (67.5 Lbs)
Cable 11/50: 400 N (90 Lbs)
Cable .141”: 270 N (60.75 Lbs)
Center contact retention force axial MIL 27 N (6.08 Lbs) cables < Ø 8 mm
68 N (15.30 Lbs) cables > Ø 8 mm
F
F
50 Ξ©CHARACTERISTICS
Standard packaging = 50 pieces. For unit packaging add Β«WΒ» after the P/N
N
13-11
ENVIRONMENTAL CHARACTERISTICS
ENVIRONMENTAL CHARACTERISTICS
MATERIALS
PLATINGS
POWER RANGE
Some connectors may feature different performances depending on the application they have been designed for, or according to the applicable cable.
TEST/CHARACTERISTICS STANDARD
REFERENCE VALUES/REMARKS
Temperature range standard models
semi-rigid cables CECC - 55Β°C + 155Β°C
- 55Β°C + 105Β°C
Thermo cycling test CECC - 55Β°C / + 155Β°C / 21 j
Thermal shock CECC - 40Β°C / + 155Β°C or - 40Β°C / + 85Β°C – 5 cycles
Hight temperature test CECC 125Β°C / 1000 H
Corrosion salt spray CECC 48 H
Vibration CECC Sinus 10 g / 10 – 500 Hz
Shock CECC 1/2 Sinus 50g / 11 ms
Moisture resistance clamp type
crimp type IEC 529 IP 67
IP 65 (with heatshrink sleeve)
Hermetic test CECC 10-5 bar. cm3/s
Leakage CECC Differential pressure 100 to 110 KPa: 1 bar cm3 / H
Body / nut / center male contact / outer contact Brass
Center female contact Treated beryllium copper
Ferrule Brass
Insulator PTFE
Gasket Silicon elastomer
Standard Intermodulation models +
COAXI-KIT
Body crimp + clamp type
solder type BBR*
Gold Silver + BBR*
Silver
Coupling nut / Design BBR* / cross knurled BBR* / hex.
Center contacts Gold Silver
Outer contacts / Design BBR* / slotted Silver + BBR* / non slotted
CHARACTERISTICS
50 Ξ©
* BBR : Bright Bronze Radiall
13-12
N
STRAIGHT PLUGS, FULL CRIMP TYPE, FOR FLEXIBLE CABLES (single piece body)
STRAIGHT PLUGS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Fig. Dimensions (mm) Captured
center
contact Assembly
instructions Note
ABCD
2.6 / 50 / S+D R161 072 000 1 39.7 3.25 3.38 1.63 yes M09
5 / 50 / S R161 082 000 2 38.5 5.41 3.11 yes M12
5 / 50 / D R161 083 000 2 38.5 5.8 3.11 yes M12
5 / 50 / D R161 083 137 3 38.5 5.8 3.11 yes M11 For intermodulation application / tool
10 / 50 / S R161 075 000 2 40.2 11.05 7.46 yes M10
10.3 / 50 / S R161 075 060 2 40.2 11.05 7.46 yes M10 LMR 400 cable
10.3 / 50 / D R161 076 000 2 40.2 11.4 6.4 yes M10 ETHERNET cable
11 / 50 / D R161 088 000 240.2 11.4 7.46 yes M10
11 / 50 / D R161 088 137 3 M11 For intermodulation application / tool
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
ABC
2.6 / 50 / S + D R161 004 000 1 33.9 3.1 1.7 yes M01
5 / 50 / S + D R 161 006 000 1 34.4 5.6 no M02
5 / 50 / S + D R 161 010 000 134.95.6 yes M03
10 + 11 / 50 / S + D R161 020 000 2 38.1 11.2 no M04
10 + 11 / 50 / S + D R161 022 000 2 38.9 11.2 yes M05
Fig. 1
Fig. 3
Fig. 2
Fig. 1 Fig. 2
PLUGS
50 Ξ©
N
13-13
STRAIGHT PLUGS, EZ FIT TYPE, FOR CORRUGATED CABLES
STRAIGHT PLUGS, FOR SEMI-RIGID CABLES
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
ABC
1/4” superflexible corrugated R161 036 007 1 44.7 7.95 4.7 yes M18
3/8” superflexible corrugated R161 036 207 1 45.1 11 7.1 yes M18
1/2” flexible corrugated R161 091 020W 2yesM19
1/2” superflexible corrugated R161 037 020 1 45.1 14 8.8 yes M18
7/8” flexible corrugated R161 033 020W 3yesM20
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Note
ABC
.141” R161 051 000 3 24.4 3.65 no M07 Solder type
.141” R161 052 000 1 35 5.6 3.65 no M06 Clamp type
.250” R161 053 000 1 35.4 6.6 no M06 Clamp type
.250” R161 054 000 2 24.4 6.45 no M07 Solder type
Fig. 1 Fig. 2
Fig. 3
Fig. 1 Fig. 2 Fig. 3
50 Ξ©PLUGS
13-14
N
RIGHT ANGLE PLUGS, CRIMP TYPE, FOR FLEXIBLE CABLES
RIGHT ANGLE PLUGS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Note
ABCD
5 / 50 / S R161 182 000 1 34.5 28 5.41 3.1 yes M08
5 / 50 / D R161 183 000 1 34.5 28 5.8 3.1 yes M08
5 / 50 / D R161 183 137 4 35 28.3 5.8 3.1 yes M08 For intermodulation application / tool
10 / 50 / S R161 184 000 2 37.5 11.05 yes M08
10 / 50 / S R161 185 000 3 42.4 33.2 11.05 7.46 yes M11 Full crimp
10.3 / 50 / S R161 184 036 2 46.25 11.05 yes M08 LMR 400 cable
11 / 50 / D R161 186 000 2 37.6 11.4 yes M08
11 / 50 / D R161 187 000 3 42.4 33.2 11.4 7.46 yes M11 Full crimp
11 / 50 / D R161 186 137 5 yes M08 For intermodulation application / tool
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
ABC
5 / 50 / S + D R161 157 000 132325.6 yes M15
10 + 11 / 50 / S + D R161 168 000 2 34.85 49.4 11.2 yes M16
Fig. 1 Fig. 2 Fig. 3
Fig. 4 Fig. 5
Fig. 1 Fig. 2
PLUGS
50 Ξ©
N
13-15
RIGHT ANGLE PLUG, SOLDER TYPE, FOR SEMI-RIGID CABLES
RIGHT ANGLE PLUGS, EZ FIT TYPE, FOR CORRUGATED CABLES
STRAIGHT JACKS, FULL CRIMP TYPE, FOR FLEXIBLE CABLES (single piece body)
Cable group Part number Captured center contact Assembly instructions
.141β€œ R161 152 107 yes M17
Cable group Part number Dimensions (mm) Captured
center contact Assembly
instructions
AB
1/4” superflexible corrugated R161 177 007 41.8 7.95 yes M13
3/8” superflexible corrugated R161 177 207 42.25 11 yes M13
1/2” superflexible corrugated R161 177 137 41.75 14 yes M13
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
ABC
5 / 50 / S R161 237 000 1 39.3 5.41 3.11 yes M12
5 / 50 / D R161 238 000 139.35.83.11 yes M12
10 / 50 / S R161 241 000 2 40.6 11.05 7.46 yes M10
11 / 50 / D R161 243 000 2 40.6 11.4 7.46 yes M10
Fig. 2Fig. 1
50 Ξ©PLUGS AND JACKS
13-16
N
STRAIGHT JACKS, CLAMP TYPE, FOR FLEXIBLE CABLES
STRAIGHT JACKS, EZ FIT TYPE, FOR CORRUGATED CABLES
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
AB
5 / 50 / S + D R161 206 000 1 35.3 5.6 yes M03
10 + 11 / 50 / S + D R161 220 000 2 39.3 11.2 yes M05
10 + 11 / 50 + 75 / S + D R161 222 000 2 39.3 11.2 yes M05
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions
AB
1/4” superflexible corrugated R161 232 007 1 52.7 7.9 yes M18
3/8” superflexible corrugated R161 232 207 26611 yes M18
1/2” superflexible corrugated R161 232 407 26614 yes M18
1/2” flexible corrugated R161 230 320W 3yesM21
7/8” flexible corrugated R161 231 020W 4yesM22
Fig. 1 Fig. 2
Fig. 1 Fig. 2
Fig. 3 Fig. 4
AA
50 Ξ©JACKS
N
13-17
STRAIGHT JACKS, FOR SEMI RIGID CABLES
25.4 mm SQUARE FLANGE, STRAIGHT JACKS, FULL CRIMP TYPE, FOR FLEXIBLE CABLES
(single piece body) (25.4 mm = 1 inch)
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Note
ABC
.141” R161 227 000 1 35.5 5.6 3.65 no M06 Clamp type
.141” R161 226 020 2 32 3.65 no M14 Solder type
Cable group Part number Dimensions (mm) Captured
center contact Assembly
instructions Panel drilling
ABC
5 / 50 / D R161 283 000 39.3 5.8 3.11 yes M12 P01
10 / 50 / S R161 286 000 40.6 11.05 7.46 yes M10 P01
11 / 50 / D R161 286 200 40.6 11.4 7.46 yes M10 P01
Fig. 1 Fig. 2
50 Ξ©JACKS
13-18
N
25.4 mm SQUARE FLANGE, STRAIGHT JACKS, CLAMP TYPE FOR FLEXIBLE CABLES
(25.4 mm = 1 inch)
25.4 mm SQUARE FLANGE, STRAIGHT JACKS, EZ FIT TYPE, FOR CORRUGATED CABLES
(25.4 mm = 1 inch)
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel drilling
ABC
2.6 / 50 / S + D R161 252 000 1 34.3 3.1 1.7 yes M01 P01
5 / 50 / S + D R161 256 000 1 35.4 5.6 yes M03 P01
10 + 11 / 50 / S + D R161 270 000 2 39.3 11.2 yes M05 P01
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel drilling
AB
1/4” superflexible corrugated R161 279 007 1 52.7 7.9 yes M18 P01
3/8” superflexible corrugated R161 279 207 2 66 11 yes M18 P01
1/2” superflexible corrugated R161 279 407 2 66 14 yes M18 P01
Fig. 1
Fig. 2
Fig. 1
Fig. 2
A
A
50 Ξ©JACKS
N
13-19
25.4 mm SQUARE FLANGE, STRAIGHT JACKS, FOR SEMI RIGID CABLES (25.4 mm = 1 inch)
BULKHEAD STRAIGHT JACKS, FULL CRIMP TYPE, FOR FLEXIBLE CABLES (PANEL SEALED)
(single piece body)
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel
drilling Note
ABC
.141” R161 277 000 1 35.5 5.6 3.65 no M06 P01 Clamp type
.141” R161 277 300 2 32 3.65 no M14 P01 Solder type
.250” R161 278 000 1 35.9 6.6 no M06 P01 Clamp type
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel
drilling Note
ABC DE
2.6 / 50 / S + D R161 311 200 140.4 6.5 3.38 3.25 1.63 yes M09 P14 Front mount
2.6 / 50 / S + D R161 311 300 2 yes M09 P14 Rear mount
5 / 50 / S R161 329 000 3 39.8 6.5 3.11 5.41 yes M12 P14 Rear mount
5 / 50 / D R161 329 200 5.8 yes M12 P14 Rear mount
Fig. 1 & 2 Fig. 1 Fig. 2
Fig. 1 Fig. 2
Fig. 3
50 Ξ©JACKS
13-20
N
BULKHEAD STRAIGHT JACKS, CLAMP TYPE, FOR FLEXIBLE CABLES (PANEL SEALED)
BULKHEAD STRAIGHT JACKS, EZ FIT TYPE, FOR CORRUGATED CABLES
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel
drilling Note
ACD
2.6 / 50 / S + D R161 321 000 1 34.3 3.1 1.7 yes M01 P14 Front mount
2.6 / 50 / S + D R161 322 000 2 34.3 3.1 1.7 yes M01 P14 Rear mount
5 / 50 / S + D R161 325 000 2 35.4 5.6 yes M03 P14 Rear mount
10 + 11 / 50 / S + D R161 332 000 3 43 11.2 no M04 P14 Rear mount
Cable group Part number Fig. Dimensions (mm) Captured
center contact Assembly
instructions Panel drilling
ABC
1/4” superflexible corrugated R161 341 007 1 52.7 6.5 7.9 yes M18 P14
3/8” superflexible corrugated R161 341 207 2666.511 yes M18 P14
1/2” superflexible corrugated R161 341 407 2 66 6.5 14 yes M18 P14
Fig. 1 Fig. 2
Fig. 3
Fig. 2
Fig. 2Fig. 1
AA
50 Ξ©BULKHEAD JACKS
N
13-21
BULKHEAD STRAIGHT JACKS, FOR SEMI RIGID CABLES (PANEL SEALED)
Cable group Part number Fig. Dimensions (mm) Captured
center
contact Assembly
instructions Panel
drilling Note
AB C D
.085” R161 335 200 1 32 6.5 2.25 no M14 P14 Solder type / Rear mount
.141” R161 323 000 2 35.5 8 5.6 3.65 no M06 P14 Clamp type / Front mount
.141” R161 323 200 4 35.5 6.5 5.6 3.65 yes M06 P14 Clamp type / Rear mount
.141” R161 336 000 1 32 6.5 3.65 no M14 P14 Solder type / Rear mount
.141” R161 336 200 3 32 6.5 3.65 no M14 P14 Solder type / Front mount
.250” R161 337 200 1 32 6.5 6.6 no M14 P14 Solder type / Rear mount
Fig. 1 Fig. 2
Fig. 3 Fig. 4
50 Ξ©BULKHEAD JACKS
13-22
N
12.7 mm (SMA) FLANGE, STRAIGHT FEMALE RECEPTACLES (12.7 mm = 1/2 inch)
17.5 mm FLANGE, STRAIGHT FEMAL E RECEPTACLES (17.5 mm = 3/4 inch)
Part number Dimensions (mm) Captured
center contact Panel drilling Note
ABC
R161 410 520 17.9 15 2.9 yes P11 Extended dielectric
Part number Fig. Dimensions (mm) Captured
center contact Panel drilling Note
ABC
R161 410 000 1 + A 5.7 1.5 8.9 yes P03
R161 418 000 2 + A yes P03 Universal / see contacts page 27
R161 461 000 3 + B 6.2 3.9 0.6 yes P12 2 hole flange / Flat tab contact
Fig. 1 Fig. 2 Fig. 3
Fig. A Fig. B
50 Ξ©RECEPTACLES
N
13-23
25.4 mm FLANGE, STRAIGHT MALE AND FEMALE RECEPTACLES (25.4 mm = 1 inch)
Part number Fig. Dimensions (mm) Captured
center contact Panel
drilling Note
ABCD
R161 404 000 1 + A 9.3 0.8 14.6 yes P07 Solder pot
R161 404 117 1 + A 9.3 2.5 14.6 yes P07 Solder pot
R161 404 137 1 + A 9.3 0.8 14.6 yes P07 For intermodulation application/Center contact brass
R161 412 020 1 + A 9.3 3.5 12 yes P10 Solder po t
R161 416 130 4 + A 17.9 15 yes P09 Extended dielectric
R161 419 020 2 + A 2.5 yes P10 Flat tab contact
R161 419 300 3 + A 2 yes P01 Slotted contact
R161 430 020 1 + A 6.5 yes P10 Short back length
R161 440 020 5 + A 6 0 20.6 yes P08 Male / solder pot
R161 441 000 5 + A 8.7 0.8 14.6 20.6 yes P02 Male / solder pot
R161 441 400 6 + A 17.9 15 yes P06 Male / extended dielectric
R161 444 037 7 + A 2 yes P05 Male / slotted contact
Fig. 1 Fig. 2 Fig. 3 Fig. 4
Fig. A Fig. 5 Fig. 6 Fig. 7
50 Ξ©RECEPTACLES
13-24
N
25.4 mm FLANGE, RIGHT ANGLE FEMALE RECEPTACLE (25.4 mm = 1 inch)
BULKHEAD STRAIGHT RECEPTACLES (fully sealed or panel hermetic)
Part number Dimensions (mm) Captured
center contact Panel drilling Note
ABC
R161 653 000 36.9 34.4 2.5 yes P02 Solder pot
Part number Fig. Dimensions (mm) Captured
center contact Panel drilling Note
ABC
R161 570 000 1 28 4.5 2.4 yes P13 Front mount
R161 606 000 2 34.6 6.5 2.4 yes P14 Rear mount /Fully sealed
R161 625 000 3 34 6.5 2.5 yes P14 Front mount / Panel hermetic
Fig. 1 Fig. 2
Fig. 3
50 Ξ©RECEPTACLES
N
13-25
IN SERIES ADAPTERS
Part number Fig. Dimensions (mm) Panel drilling Note
AB
R161 703 000 1 36.7 M - M
R161 705 000 2 37.5 F - F
R161 715 000 3 37.5 P01 F - F / Flange
R161 730 000 4 37.5 6.5 P14 F - F / Bulkhead panel sealed
R161 753 000 5 38 6.5 P14 F - F / Hermetic / bulkhead
R161 771 000 6 34.4 34 M - F / Right–angle
R161 780 000 7 42 36.9 TEE F - F/M
R161 782 000 8 42 29.1 TEE F - F/F
R161 791 500 9 37.37 Push - on male / female screwing
R161 791 530 10 37.12 screwing male / Push - on female
R161 792 500β€’11 37.12 Push - on male / male screwing
Fig. 1 Fig. 2
Fig. 4
Fig. 3
Fig. 9
Fig. 5
Fig. 7 Fig. 8
Fig. 10 Fig. 11
Fig. 6
β€’ Upon request
50 Ξ©IN SERIES ADAPTERS
13-26
N
PROTECTIVE CAPS
Part number Fig. Dimensions (mm) Note
AB
R161 804 000 1 13.9 3.8 Male with cord
R161 805 410 2 13.9 2 Male with cord
R161 841 000 3 20.4 3.9 Female with chain
R161 844 000 4 20.4 3.8 Female with cord
R161 853 000 5 13.9 3.9 Male with chain
R161 862 000 6 20.1 3.9 Male short circuit with chain
Fig. 1 Fig. 2 Fig. 3
Fig. 4 Fig. 5 Fig. 6
50 Ξ©CAPS
N
13-27
FIELD-REPLACEABLE CONTACTS (For universal receptacle)
These accessories have been specifically designed for the adjustment at the rear of hermetically sealed universal
receptacles.
The choice of their dimensions depends on the PCB or on the thickness of the MIC box. Moreover these contacts and
insulators are al s o compat ibl e wi th SMA UN IVE RSAL RECE PTA CLES.
FIELD-REPLACEABLE INSULAT ORS
Part number Fig. A Packaging Note Associated insulator P/N
R280 460 000 11.77
10
Flat tab R280 467 0000
R280 461 000 1 3.37 Flat tab R280 468 0000
R280 462 000 2 1.77 Cylindrical tab R280 467 0000
R280 463 000 2 3.37 Cylindrical tab R280 468 0000
R280 464 000β€’3 Symetrical N/A
R280 465 000 4 Flat recessed tab N/A
Part number A Packaging
R280 467 000 1.57 10
R280 468 000 3.17 10
Fig. 3
Fig. 4
Fig. 1
Fig. 2
50 Ξ©ACCESSORIES
β€’ Upon request
13-28
N
What is INTERMODULATION ?
IM (abbreviation for InterModulation) is an undesired
modulation which leads to a distortion of the output High
Frequency carrier.
It is defined as the ratio of the 3rd order intermodulation
products against the incident signal power because, the
most troub lesome IM prod uc ts ar e th ose of 3rd order .
For more detailed information, ple ase ask for our application
guide where we present:
- our intermodulation measurement system,
- our product range.
BBR
(B
r
i
g
h
t
B
ronze
RADIALL)
p
l
at
i
ng
h
as
b
een spec
ifi
ca
ll
y
developed and employed by RADIALL for its excellence in
Intermodulation sensitive applications.
For more detailed information, an application guide about
the BBR high quality plating is available upon request.
50 Ξ©
D1C 032 DE
D1C 030 DE
N
13-29
R
a
di
a
ll
proposes you
3
t
ypes o
f
ca
bl
e assem
bli
es w
ith
N
t
ype
connectors.
This range includes standard and custom cable assemblies, offering
you standard, main and high level of intermodulation pe rfor man ce ( see
our intermodulation application guide: D1C 032 DE).
β€’Standard level: IMP3 = -90 dBm typical (see page 30-31)
The main characteristics of this range are:
- cross-knurled coupling nut
- coupling torque 130 Ncm (with pliers R282 202 000)
- slotted outer contact
- plating: BBR (Bright Bronze Radiall)
- connectors also available uncabled
- 3 types of cable mounting: full crimp, clamp or solder
β€’Main level: IMP3 = -110 dBm typical (see page 32-33)
The main characteristics of this range are:
- hexagonal coupling nut (170 Ncm)
- non-slotted outer contact
- plating: silver (finish: strike of BBR)
- connectors also available uncabled (except for SHF cable)
- 3 types of cable mounting: full crimp, clamp or solder
β€’High level: IMP3 = -125 dBm typical (see page 34-35)
The main characteristics of this range are:
- hexagonal coupling nut (170 Ncm)
- non-slotted outer contact
- plating: silver (finish: strike of BBR)
- connectors only available for cable assemblies made by Radiall
- only solder type models: the most rigid cable attachment
- Intermodulation curves available upon request
- moisture resistance: IP 68 overmolding
SERVICE + webtool: fast and reliable:
Your solution for RF & Microwave cable-assemblies on www.radiall.com
SIMPLE - FAST - EFFICIENT
50 Ξ©CABLE ASSEMBLIES
13-30
N
CABLE ASSEMBLIES WITH STANDARD CONNECTORS (-90 dBm typ.) (-133 dBc typ./20W)
HOW TO ORDER
Example: Straight plug N / Cable 5/50 D RG223 / Right angle plug / leng th 100 cm
L : Overall length + 2 %
R161 083 000 / C291 330 000 / R161 183 000 / 100
Connector 1 part number (see table 1)
Coax cable part number (see table 2)
Connector 2 part number (see table 1)
Overall length in cm
50 Ξ©-90 dBm CUSTOM CABLE ASSEMBLI ES
N
13-31
CABLE ASSEMBLIES WITH STANDARD CONNECTORS (-90 dBm typ.) (-133 dBc typ./20W)
Table 1 Connectors part number guide
Table 2 Radiall cable part number guide
MODEL SEMI-RIGID CABLES FLEXIBLE CABLES TIMES
.085” .141” .250” 2.6 /5 0 S 2.6 / 50 D 5 / 50 S 5 / 50 D 10 / 50S 11 / 50 D LMR 400
Straight
plug
Solder R161 051 000 R161 054 000
Clamp R161 052 000 R161 053 000 R161 004 000 R161 006 000
R161 010 000 R161 020 000
R161 022 000
Full crimp R161 072 000 R161 082 000 R161 083 000 R161 075 000 R161 088 000 R161 075 060
R/A
plug
Clamp R161 157 000 R161 168 000
Crimp R161 182 000 R161 183 000 R161 184 000 R161 186 000 R161 184 036
Full crimp R161 185 000 R161 187 00 0
Straight
jack
Solder R161 226 020
Clamp R161 206 000 R161 222 000
R161 220 000
Full crimp R161 237 000 R161 238 000 R161 241 000 R161 243 000
Straight
bulkhead
jack rear
mount
Solder R161 335 200 R161 336 000 R161 337 200
Clamp R161 323 200 R161 321 000
R161 322 000 R161 325 000 R161 332 000
Full crimp R161 311 300 R161 329 000 R161 329 200
Straight
bulkhead
jack front
mount
Solder
Clamp R161 323 000
R161 323 020β€’R161 321 000
Full crimp R161 311 20 0
Straight jack
flange
mount
Solder R161 277 300
Clamp R161 277 000 R161 278 000 R161 252 000 R161 256 000 R161 270 000
Full crimp R161 283 000 R161 286 000 R161 286 200
CABLE TYPE P / N
SEMI-RIGID
.085” RG 405 C291 850 001
.141” RG 402 C291 860 001
.250” RG 401 C291 870 001
FLEXIBLE
2 / 50 S RG 178 C291 145 007
2 / 50 D FILOTEX C291 146 087
2.6 / 50 S RG 174 C291 150 000
2.6 / 50 D OREBRO C291 185 067
5 / 50 S RG 58 C291 305 000
5 / 50 D RG 223 C291 330 000
10 / 50 S RG 213 C291 510 000
11 / 50 D RG 214 C291 600 000
TIMES
5 / 50 S LMR 200 C291 316 070
10.3 / 50 S LMR 400 C291 516 070
15.2 / 50 S LMR 600 C291 626 070
50 Ξ©-90 dBm CUSTOM CABLE ASSEMBLI ES
β€’ Manufactured upon request All our bulkhead mount jacks are panel sealed
13-32
N
CABLE ASSEMBLIES WITH LOW INTERMODULATION CONNECTORS
(-110 dBm typ.) (-153 dBc typ./20W)
HOW TO ORDER
Example: Straight plug N / Cable 11 / 50 D RG 214 / Right angle plug N / length 100 cm
L : Overall length + 2 %
R161 088 137 / C291 600 000 / R161 186 137 / 100
Connector 1 part number (see table 1)
Coax cable part number (see table 2)
Connector 2 part number (see table 1)
Overall length in cm
50 Ξ©-110 dBm CUSTOM CABLE ASSEMBLIES
N
13-33
CABLE ASSEMBLIES WITH LOW INTERMODULATION CONNECTORS
(-110 dBm typ.) (-153 dBc typ./20W)
Table 1 Connectors part number guide
All these connectors are also available unassembled, except models for SHF cables only sold on cable assemblies made
by RADIALL.
Table 2 Radiall cable part number guide
SERIES MODEL CABLES SUPER FLEXIBLE CABLES
5 / 50 D 11 / 50 D 1/4” 3/8” 1/2”
N
Straight plug Full crimp R161 083 137 R161 088 137
Clamp R161 036 007 R161 036 207 R161 037 020
R/A plug Crimp R161 183 137 R161 186 137
Clamp R161 177 007 R161 177 207 R161 177 137
Straight jack Clamp R161 232 007 R161 232 207 R161 232 407
Straight bulkhead jack Clamp R161 341 007 R161 341 207 R161 341 407
Straight flange mount jack Clamp R161 279 007 R161 279 207 R161 279 407
CABLE TYPE P / N
SEMI-RIGID .141” RG 405 C291 860 001
FLEXIBLE 5 / 50 D RG 223 C291 330 000
11 / 50 D RG 214 C291 600 000
(PTFE)
FLEXIBLE 5 / 50 D RG 400 C291 326 007
10 / 50 D RG 393 C291 511 007
CORRUGATED
1/4” superflexible corrugated High flexible CELLFLEX C291 993 170
HELIAX C291 993 070
3/8” superflexible corrugated High flexible CELLFLEX C291 996 170
HELIAX C291 996 070
1/2” superflexible corrugated High flexible CELLFLEX C291 994 170
HELIAX C291 994 070
SHF*5 TD RADIALL C291 999 902
5 LI C291 955 192
50 Ξ©-110 dBm CABLE ASSEMBLIES
Note: All our bulkhead mount jacks are panel sealedFor more details about SHF cables, see our catalog D1C 287 CE
13-34
N
VERY LOW INTERMODULATION CABLE ASSEMBLIES (-125 dBm typ.) (-165 dBc typ./20W)
HOW TO ORDER
Example: Straight plug N / Cable 1/4" high flexible Cellflex / right angle plug N / length 50 cm
L : Overall length + 2 %
865 48 030 / C291 993 170 / 865 48 040 / 50
Connector 1 part number (see table 1)
Coax cable part number (see table 2)
Connector 2 part number (see table 1)
Overall length in cm
-125 dBm CABLE ASSEMBLIES
50 Ξ©
N
13-35
VERY LOW INTERMODULATION CABLE ASSEMBLIES (-125 dBm typ.) (-165 dBc typ./20W)
Table 1 Connectors part number guide
These connectors are only available for cable assemblies made by Radiall.
Table 2 Cable assemblies with standard lengths
SERIES MODEL
Solder Type SUPERFLEXIBLE CORRUGATED SEMI-RIGID (PTFE) FLEXIBLE
1/4” 3/8” 1/2” .141” RG 400 RG 393
N
Straight plug 865 48 030 865 48 080 865 48 120 865 48 000
Please consult us
R/A plug 865 48 040 865 48 090 865 48 130 865 48 010
Straight jack 865 48 050 865 48 100 865 48 140
Straight panel sealed bulkhead jack 865 48 060 865 48 110 865 48 150 865 48 020
Straight flange mount jack 865 48 070 865 48 170 865 48 160
CONNECTOR 1 CABLE CONNECTOR 2 CABLE ASSEMBLY Fig
Series Model Type Length (m) Series Model P / N
N
Straight plug
3/8” superflexible corrugated
1.5 N
Straight plug R285 780 063 1
1/2” superflexible corrugated R285 780 083
3/8” superflexible corrugated R/A plug R285 783 063 2
R/A plug Straight bulkhead jack R285 786 063 3
Straight plug
3/8” superflexible corrugated
1.5 7/16
Straight plug R285 720 063 4
1/2” superflexible corrugated R285 720 083
3/8” superflexible corrugated
Straight flange jack
R285 725 063 5
1/2” superflexible corrugated R285 725 083
R/A plug 1/4” superflexible corrugated 1 R285 724 042 6
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
-125 dBm CABLE ASSEMBLIES
50 Ξ©
13-36
N
LETTER mm inch LETTER mm inch
min. max. min. max. min. max. min. max.
A 0.13 1.03 .005 .13 A 9.05 9.19 .356 .362
B 2.80 3.56 .110 .140 B 4.75 5.25 .187 .207
C 5.33 5.83 .210 .230 C 1.20 1.95 .047 .077
D 1 2 .016 .066 D 4.4 5.1 .173 .201
E 4.54 5.39 .179 .212 E 6.8 9 .268 .354
F 4.05 4.20 .159 .165 F 10.9 11.2 .429 .441
G 10.23 10.43 .403 .411 G DIA 6.98 7.02 .275 .276
H DIA 8.27 8.37 .326 .329 H DIA 8.03 8.13 .316 .320
J DIA 16.1 16.2 .634 .638 J DIA 8.53 8.73 .336 .344
K DIA 20.9 21 .823 .827 K DIA 15.65 15.85 .616 .624
L DIA 1.96 2 .077 .079 L DIA 1.96 2 .077 .079
M DIA 0.87 0.91 .034 .036
PLUG JACK
75 Ξ©INTERFACE
* statistics dimensions: .0539 .0055 (.0594 max)/(1.37 0.14)(1.51 max)
1) Coupling nut against on datum 1
2) Coupling nut against on datum 2
IMPORTANT: the 50 Ξ© and the 75 Ξ© connectors are NOT INTERMATEABLE, resulting in the interface des tru ct io n
N
13-37
ELECTRICAL CHARACTERISTICS
MECHANICAL CHARACTERISTICS
ENVIRONMENTAL CHARACTERISTICS
MATERIALS
PLATINGS
TEST/CHARACTERISTICS STANDARD
REFERENCE VALUES/REMARKS
Impedance 75 Ξ©
Frequency range DC - 1.5 GHz
V.S.W.R. (typical) Cable 6/75
Cable 10 +11/75 1.06
1.10
Insertion loss straight connect or
right-angle connector MIL < 0.15 dB
RF Leakage MIL - 90 dB min at 1 GHz
Insulation resistance MIL 5000 MΞ© min
Contact resistance center contact
outer contact MIL Initial
1 mΞ©
0.2 mΞ©
After tests
1.5 mΞ©
-
Working voltage in VRMS at sea level (at 70, 000 feet) CECC Cable 10 + 11/75: 1400 (400)
Cable 6/75: 850 (250)
Dielectric withstanding voltage in VRMS
at sea level (at 70, 000 feet) CECC Cable 10 + 11/75: 2500 (600)
Cable 6/75: 1500 (350)
RF testing voltage sea level CECC 1500 VRMS (5 MHz sine wave)
Durability CECC 500 matings
Force to engage and disengage CECC 6.6 Ncm max (.58 Inch-pounds)
Recommended coupling nut torque 40 to 60 Ncm (manual)
130 Ncm (11.45 inch pounds) (with pliers R282 202 000)
Proof torque CECC 170 Ncm (14.96 inch pounds)
Coupling nut retention force CECC 450 N (101.25 Lbs)
Cable retention force cable 6/75
cable 10 +11/75 CECC 200 N
300 N
Center contact retention force axial MIL 27 N (6.08 Lbs)
Temperature range CECC - 55Β°C + 155Β°C
Thermo cycling test CECC - 55Β°C / + 155Β°C / 21 j
Thermal shock CECC - 40Β°C / + 155Β°C or - 40Β°C / + 85Β°C – 5 cycles
Hight temperature test CECC 125Β°C / 1000 H
Corrosion s alt s pray CECC 48 H
Vibration CECC Sinus 10 g / 10 – 500 Hz
Shock CECC 1/2 Sinus 50g / 11 ms
Moisture resistance clamp type
crimp type IEC 529 IP 67
IP 65 (with h eatshrink sleeve)
Hermetic test CECC 10-5 bar. cm3/s
Leakage CECC Differential pressure 100 to 110 KPa: 1 bar cm3 / H
Body (nut) / center male contact / outer contact Brass
Center female contact Treated beryllium copper
Ferrule Brass
Insulator PTFE
Gasket Silicon elastomer
Body BBR
Coupling nut / Design BBR / cross knurled
Center contacts Gold
Outer contacts / Design BBR / slotted
75 Ξ©CHARACTERISTICS
All dimensions in mm
Standard packaging = 50 pieces. For unit packaging add Β«WΒ» after the P/N
13-38
N
STRAIGHT PLUGS, CRIMP TYPE, FOR FLEXIBLE CABLES
STRAIGHT PLUGS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Dimensions (mm) Captured center
contact Assembly instructions
AB C
6 / 75 / S R162 084 000 33.9 6.6 4 yes M12
10 / 75 / S R162 075 000 37.25 11.05 7.46 yes M12
11 / 75 / D R162 088 000 37.25 11.4 7.46 yes M12
Cable group Part number Fig. Captured center
contact Assembly instructions
6 / 75 + 93 R162 012 000 1no M02
8 / 75 / D R162 013 000 2no M16
10 + 11 / 75 R162 017 000 3no M04
Fig. 1 Fig. 2 Fig. 3
75 Ξ©PLUGS
N
13-39
RIGHT ANGLE PLUGS, CRIMP TYPE, FOR FLEXIBLE CABLES
RIGHT ANGLE PLUGS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Dimensions (mm) Captured center
contact Assembly
instructions
ABC
6 / 75 / S R162 184 000 38.25 6.6 4 yes M12
10 / 75 / S R162 185 000 42.25 11.05 7.46 yes M12
11 / 75 / D R162 187 000β€’42.25 11.4 7.46 yes M12
Cable group Part number Dimensions A (mm) Captured center
contact Assembly
instructions
6 / 75 + 93 R162 162 000 6.5 yes M16
10 + 11 / 75 R162 168 000 11.2 yes M16
75 Ξ©PLUGS
β€’ Upon request
13-40
N
STRAIGHT JACKS, CRIMP TYPE, FOR FLEXIBLE CABLES
STRAIGHT JACKS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Dimensions (mm) Captured center
contact Assembly
instructions
AB C
6 / 75 / S R162 239 000 36.6 6.6 4 yes M12
10 / 75 / S R162 241 000β€’40.6 11.05 7.46 yes M12
11 / 75 / D R162 243 000β€’40.6 11.4 7.46 yes M12
Cable group Part number Fig. Captured center
contact Assembly
instructions
6 / 75 + 93 / S R162 212 000β€’1no M02
8 / 75 / D R162 213 000β€’2no M16
10 + 11 / 75 R162 217 000 3no M04
Fig. 1 Fig. 2 Fig. 3
75 Ξ©JACKS
β€’ Upon request
N
13-41
SQUARE FLANGE STRAIGHT JACKS, CLAMP TYPE, FOR FLEXIBLE CABLES
STRAIGHT BULKHEAD JACKS, CRIMP TYPE, FOR FLEXIBLE CABLES
STRAIGHT BULKHEAD JACKS, CLAMP TYPE, FOR FLEXIBLE CABLES
Cable group Part number Dimensions (mm) Captured
center contact Assembly
instructions Panel drilling
AB C
6 / 75 + 93 / S R162 262 000 34.9 6.6 11 no M02 P01
10 + 11 / 75 R162 267 000 38.5 11.2 17.4 no M04 P01
Cable group Part number Dimensions (mm) Captured center
contact Assembly
instructions Panel drilling
AB
6 / 75 / S R162 335 000β€’6.6 4 yes M12 P14
10 / 75 / S R162 336 000 11.05 7.46 yes M12 P14
11 / 75 / D R162 339 000β€’11.4 7.46 yes M12 P14
Cable group Part number Fig. Captured center contact Assembly instructio ns Panel drilling
6 / 75 + 93 / S R162 328 000β€’1no M02 P14
10 + 11 / 75 R162 332 0 00β€’2no M04 P14
Fig. 1 Fig. 2
JACKS
75 Ξ©
β€’ Upon request
13-42
N
FEMALE RECEPTACLES
IN SERIES ADAPTERS
Part number Fig. Captured center contact Panel drilling
R162 403 000 1yes P07
R162 570 000 2yes P15
Part number Fig. Captured center contact
R162 703 000 1yes
R162 705 000 2yes
Fig. 1 Fig. 2
Fig. 1 Fig. 2
RECEPTACLE & ADAPTERS
75 Ξ©
N
13-43
P01 P02 P03
P04 P05 P06
P07 P08 P09
P10 P11 P12
P13 P14 P15
PANEL DRILLING
13-44
N
M 01
Part number Stripping length (mm)
abcde
R161 004 000
R161 252 000 R161 321 000
R161 322 000 42824
STRIPPING DIMENSIONS
42
- Slide clamp nut onto cable.
- Strip the cable.
- Cut the jacket (2 slots) appart if necessary.
1
- Solder the cable inner conductor into center
contact.
- S l i de th e ba ck nut over the clamp assembly.
3
- Slide the clamp braid sleeve between cable dielectric
and braid.
- Cut the braid flush with the clamp braid sleeve.
- Slide the insulator.
- Mount the gasket into the connector.
- Screw sub-assembly into the connector body.
(recommended coupling torque 13.27 in.lb -
150 Ncm).
ASSEMBLY INSTRUCTIONS
N
13-45
M 02
Part number Stripping length (mm)
abc
R161 006 000 7.5 41
R162 012 000 R162 262 000
R162 212 000 R162 328 000 82
STRIPPING DIMENSIONS
42
- Strip the cable.
1
- Solder the cable inner conductor into center
contact.
3
- Slide the clamp nut, the washer and the 'V' groove
gasket onto the ca bl e .
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Trim back dielectric as shown.
- Screw sub-assembly into the connector body.
(recommended coupling torque 39.82 in.lb -
450 Ncm).
ASSEMBLY INSTRUCTIONS
13-46
N
M 03
Part number Stripping length (mm)
abc
R161 010 000 47.52
R161 206 000
R161 256 000 R161 325 000 1
STRIPPING DIMENSIONS
42
- Strip the cable.
1
- Slide the washer and the insulator onto the
dielectric.
- Solder the cable inner conductor into center
contact.
3
- Slide the clamp nut, the washer and the 'V' groove
gasket onto the cable.
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Tri m ba ck di e l ect r i c as sho w n.
- Screw sub-assembly into the connector body.
(recommended coupling to rque 39.83 in.lb -
450 Ncm).
a
ASSEMBLY INSTRUCTIONS
N
13-47
M 04
Part number
R161 020 000 R162 017 000 R162 267 000
R161 332 000 R162 217 000 R162 332 000
STRIPPING DIMENSIONS
42
- Strip the cable.
1
- Solder the cable inner conductor into center
contact.
3
- Slide the clamp nut and the 'V' groove gasket onto the
cable.
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Trim back dielectric as shown.
- Screw sub-assembly into the connector body.
(recommended coupling to rque 70.87 in.lb -
800 Ncm).
ASSEMBLY INSTRUCTIONS
13-48
N
M 05
Part number
R161 022 000 R161 222 000
R161 220 000 R161 270 000
STRIPPING DIMENSIONS
42
- Strip the cable.
1
- Mount washer and rear insulator.
- Solder the cable inner conductor into center
contact.
3
- Slide the clamp nut, the washer and the 'V' groove
gasket onto the ca bl e .
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Trim back dielectric as shown.
- Mount front insulator.
- Screw sub-assembly into the connector body.
(recommended coupling torque 70.87 in.lb -
800 Ncm).
ASSEMBLY INSTRUCTIONS
N
13-49
M 06
Part number Stripping length
(mm) a Stripping tool Trimmer Solder barrel gauge Positioner
R161 052 000
4.5
R282 053 000 R282 066 010 R282 744 320 R282 744 261
R161 053 000 R282 054 000 R282 074 020 R282 744 330
R161 227 000
R161 277 000 R282 053 000 R282 066 010 R282 744 320
R282 744 260R161 278 000 R282 054 000 R282 074 020 R282 744 330
R161 323 000
R161 323 200 R282 053 000 R282 066 010 R282 744 320
STRIPPING DIMENSIONS
4
2
- Take the tool kit: R282 125 010 (or spare tools).
- Strip the dielectric of the cable with stripping tool.
- Trim cable center conductor with trimmer.
- Clean the cable.
1
- Once cooled, remove the solder barrel gauge.
- Cut the dielectric flush to clamp braid sleeve.
- Slide the insulator onto the cable inner conductor.
- Slide the center contact onto the cable inner
conductor against insulator.
- Fit the cable assembly onto the soldering jig
R282 740 030 and the posi tioner.
- Tighten cable and solder the center contact.
3
- Slide the clamp nut, the washer, the 'V' groove
gasket, the clamp braid sleeve and the solde r barrel
onto the cable.
- Position solder barrel flush against solder barrel
gauge and solder to the cable or alig n with outer the
conductor.
- Screw sub-assembly into the connector body.
(recommended coupling torque 22.12 in.lb -
250 Ncm).
ASSEMBLY INSTRUCTIONS
13-50
N
M 07
Part number S tripping length
(mm) a Stripping tool Trimmer Solder gauge
[thickness b] Positioner Dielectric insertion
tool + plunger Dielectric
recess tool
R161 051 000 4.5 R282 053 000 R282 066 010 R282 862 070
[0.35] R282 744 340 R282 730 161 R282 915 030
R161 054 000 R282 054 000 R282 074 020 R282 862 080
[0.45) R282 744 350 R282 730 160 R282 915 040
STRIPPING DIMENSIONS
4
2
- Take the tool kit : R282 125 010 (or spare tools).
- Strip the dielectric of the cable with stripping tool
cable.
- Trim the cable center conductor with trimmer
- Clean the cable.
1
- After cooling remove cable assembly from the jig.
- Screw positioner into the connector.
- Slide cable into the connector until it bottoms
against positioner.
- Tighten.
- Put 3 rings of solder around the cable and solder.
3
- Screw the positioner R282 744 261 onto the soldering
jig R282 740 030.
- Slide contact into positioner.
- Insert solder gauge between contact and cable
- Tig hten and solder the contact. - Aft er cool i n g re mo ve ca bl e assembly from the jig.
- Screw female dielectric insert tool onto connector
and cut the excess of dielectric with the dielectric
recess tool.
- Insert insulator with the dielectric plunger.
ASSEMBLY INSTRUCTIONS
N
13-51
M 08
Part number Stripping length(mm) Crimping tool
a b c d Dies included MIL standard R282 293 000
(M22520/5-01) + Dies
R161 182 000
R161 183 000
R161 183 137 3.5 7 18 14.5 R282 223 000
Hex : 5.41 R282 235 011 (M22520/5-11)
R161 184 000
2.5
10 22.5 20
R282 231 000
Hex : 10.54 R282 235 116
(Y116 Daniels)
R161 184 036 16.7 29.2 26.7
R161 186 000 10 22.5 20
R161 186 137 5 8 21 16
STRIPPING DIMENSIONS
42
- Slide onto the cable the ferrule.
- Strip the cable.
1
- Crimp the ferrule with crimping tool.
- Solder inner conductor.
3
- Fan the braid.
- Push connector body under the braid.
- Slide the ferrule on the braid (in direction F).
- Screw the nut into the body or press cap flush or
slightly bellow surface of body assembly.
ASSEMBLY INSTRUCTIONS
13-52
N
M 09
Part number Stripping length (mm) Crimping tool
a b c d Dies included MIL standard R282 293 000
(M22520/5-01) + Dies Center contact
R161 072 000
R161 311 200
R161 311 300 4.5 9.5 14 8 R282 223 000
Hex : 5.41 R282 235 011
(M22520/5-11) R282 223 000
Hex : 1.73
STRIPPING DIMENSIONS
42
- Slide the ferrule onto the cable.
- Strip the cable.
1
- Slide cable dielectric into the body while gently
ginding the braid over the knurl.
- Push until the dielectric clicks into position.
- Slide ferrule over the braid (in direction F).
3
- Fan the braid.
- Slide the braid clamp and insulator between the
dielectric and the braid.
- Slide on center contact until it bottoms against cable
dielectric.
- C rimp center contact with crimping to ol or so ld e r.
- Crimp the ferrule with crimping tool.
- Cut the excess of braid.
ASSEMBLY INSTRUCTIONS
N
13-53
M 10
Part number Stripping length (mm) Crimping tool
a b c d Dies included MIL standard R282 293 000
(M22520/5-01) + Dies
R161 075 000
R161 088 000
R161 241 000
R161 243 000
R161 286 000
R161 286 200 58149
R282 231 000
Hex: 2.54 - 10.54 R282 235 116
Y116 Daniels
R161 075 060 R161 076 000 91510
STRIPPING DIMENSIONS
42
- Slide the ferrule onto the cable.
- Strip the cable.
1
- Fan the braid.
- Slide cable dielectric into the body while gently
ginding the braid over the knurl.
- Push until the dielectric clicks into position.
- Slide ferrule over the braid (in direction F).
3
- Slide on center contact until it bottoms against cable
dielectric.
- Crimp center contact with crimping to ol .
- Crimp the ferrule with crimping tool.
- Cut the excess of braid.
ASSEMBLY INSTRUCTIONS
13-54
N
M 11
Part number Stripping length (mm) Hex. Crimping tool
a b c d Dies included MIL standard R282 293 000
(M22520/5-01) + Dies
R161 083 137 4.5
814 9.5 ferrule 5.41
center contact 1.73 R282 223 000 R282 235 011
(M22520/5-11)
R161 088 137 59
ferrule 10.54
center contact 2.54 R282 231 000 R282 235 116
(Y116 Daniels)
R161 185 000
R161 187 000 4.5 15 10.5
STRIPPING DIMENSIONS
42
- Slide onto the cable the ferrule.
- Strip the cable.
1
- Fan the braid.
- Slide cable dielectric into the body while gently
ginding the braid over the knurl.
- Push until the dielectric clicks into position.
- Slide ferrule over the braid (in direction F).
3
- Slide on the center contact until it bottoms against
cable dielectric.
- C rimp center contact with crimping to ol .
- Crimp the ferrule with crimping tool.
- Cut the excess of braid.
ASSEMBLY INSTRUCTIONS
N
13-55
M 12
Part number
Stripping length (mm)
Hex.
Center contact crimping tool Ferrule crimping tool
a b c d Dies included MIL standard
R282 293 000
(M22520/5-01) + dies Dies included MIL standard
R282 293 000
(M22520/5-01) + dies
R162 084 000
R162 184 000 4.5
8149.5
1.73-6.48
R282 223 000 R282 235 011
(M22520/5-11)
R282 223 000 R282 235 013
(M22520/5-13)R162 239 000 7.5 15.5 11
R162 335 000 816 11.5
R162 075 000 5149
1.73-10.54 R282 231 000 R282 235 116
(Y116 DANIELS)
R162 088 000
4.5
7.5 17 12.5
R162 185 000 8 15 10.5
R162 187 000
R162 241 000
R162 243 000 7.5 17 12.5
R162 336 000
R162 339 000
8
16 11.5
R161 082 000
R161 083 000
R161 237 000
R161 238 000
R161 283 000
R161 329 000
R161 329 200
14 9.5 1.73-5.41 R282 223 000 R282 235 011
(M22520/5-11)
STRIPPING DIMENSIONS
2
4
- S lide the ferrule onto the cable.
- S trip the cable.
1
- Fan the braid.
- Slide the cable into the body until it bottoms
against insulator.
- Slide the ferrule over the braid (in direction F).
- Slide center contact on until it bottoms against
cable dielectric.
- Crimp the center contact.
3
- Crimp the ferrule.
- Cut the excess of braid if necessary.
ASSEMBLY INSTRUCTIONS
13-56
N
M 13
Part number Stripping tool Stripping length (mm)
abcdef
R161 177 007 R282 010 030 7.5 10 22.5 15 16
R161 177 207 R282 010 040 9 12 29 20 21 20
R161 177 137 R282 010 050 10.5 14 33.5 23
STRIPPING DIMENSIONS
4
2
- Strip the cable.
- Strip the cable inner conductor with stripping tool.
1
- Screw the clamp nut into the connector body.
(recommended coupling torque 70.8 in.lb -
800 Ncm).
(The cable must not turn into the right angle body).
- Solder the cable inner conductor into cente r
contact.
3
- Slide the clamp nut and the gasket-1 onto the cable.
- Screw the clamp braid sleeve with the gasket-2 on to
the spiral braid of the cable.
- Tighten manualy. - Place the cap.
- Press fit the cap with a flat punch.
ASSEMBLY INSTRUCTIONS
N
13-57
M 14
Part number Stripping le ngth
(mm) a Stripping tool Trimmer Solder gauge
[thickness b] Positioner
R161 335 200 3.17 R282 051 000 R282 063 000
R282 862 090
[0.7]
R282 744 300
R161 226 020
R161 277 300
R161 336 000
R161 336 200 4.5 R282 053 000 R282 066 010 R282 744 310
R161 337 200 R282 054 000 R282 074 020 R282 862 080
[0.45] R282 744 330
STRIPPING DIMENSIONS
2
4
- Take the tool kit : R282 125 010.
- Strip the dielectric of the cable with stripping tool.
- Trim the cable center conductor with trimmer.
- Clean the cable.
- Screw the reducer on the cable.
1
- After cooling remove cable assembly from the jig.
- Put positioner on the soldering jig.
- Slide cable into the reducer until it bottoms against
positioner.
- Tighten.
- Put 3 rings of solder around the cable and solder.
- Screw the positioner R282 744 060 onto the soldering
jig R282 740 030.
- Slide contact into positioner.
- Insert solder gauge between contact and cable.
- Tig hten and solder the contact. - After cooling remove cable assembly from the jig.
- Slide insulator into the center contact.
- Screw sub-assembly into the connector body.
(recommended coupling torque 13.27 in.lb -
150 Ncm).
3
ASSEMBLY INSTRUCTIONS
13-58
N
M 15
Part number
R161 157 000
STRIPPING DIMENSIONS
4
2
- Strip the cable.
1
- Screw sub-assembly into the connector body.
(recommended coupling torq ue 13.27 in.lb -
150 Ncm).
- Solder center contact.
3
- Slide the clamp nut, the washer and the gasket onto
the cable.
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Tri m ba ck di e l ect r i c as sho w n.
- Screw clamp nut into the body.
ASSEMBLY INSTRUCTIONS
N
13-59
M 16
Part number Stripping length (mm) Center contact crimping tool
a b c Dies inclu ded MIL standard R282 293 000
(M22520/5-01) + dies
R161 168 000 10 42.5 R282 231 000
Hex. 2.54 R282 235 116
(Y116 DANIELS)
R162 013 000
R162 213 000 4.5 1.5
R162 162 000
R162 168 000 8.5 4 1
42
- Strip the cable.
1
- Solder the cable inner conductor into center
contact.
3
- Slide the clamp nut, the washer and the gasket onto
the cable.
- Slide clamp braid sleeve over braid.
- Fold back braid and trim off excess of braid.
- Trim back dielectric as shown.
- Screw sub-assembly into the connector body.
(recommended coupling torq ue 44.25 in.lb -
500 Ncm).
ASSEMBLY INSTRUCTIONS
13-60
N
M 17
Part number Stripping length (mm) Soldering Assembly
ab
R161 152 107 9 3 R282 740 030
STRIPPING DIMENSIONS
2
4
- Strip the dielectric of the cable .
- Clean the cable.
- Temperature stoking do not exceed 250Β° max.
1
- After cooling remove cable assembly from the jig.
- Slide body into positioner until it bottoms againts
the positioner.
- Slide cable assembly onto the jig.
- Tighten and solder the contact.
- After cooling remove cable assembly from the jig.
- Slide cable and connector onto the soldering jig.
- Slide cable into connector until it bottoms againts
the body and tighten.
- Solder the body onto the cable.
3
- Screw the cap until it bottoms againts the body
(direction F).
ASSEMBLY INSTRUCTIONS
We recommend a thermal preconditionning cable
N
13-61
M 18
Part number Stripping length (mm) Stripping tool Torque spanner
abc
R161 036 007
R161 232 007
R161 279 007
R161 341 007
5.5 5 11.5
R282 010 030
R282 303 220
(0.708 in 84.075 in lb)
R161 036 207
R161 232 207
R161 279 207
R161 341 207
R282 010 040
R161 037 020
R161 232 407
R161 279 407
R161 341 407
R282 010 050
STRIPPING DIMENSIONS
2 4
- Strip the cable.
- Do not damage the outer conductor.
- Deburr cable inner conductor.
1
- Screw the connector onto the assembly.
WARNING : Screw the connector on the braid
clamp nut turning left (left-hand thread) so that the
copper outer conductor is being squeezed.
- Slide the heatshrink sleeve onto the cable.
- Screw manually the braid clamp nut onto cable
outer conductor until stop.
3
ASSEMBLY INSTRUCTIONS
13-62
N
M 19
Part number Stripping length (mm) Stripping tool
abce
R161 091 020 W 5 16 23.7 2.7 R282 011 050
STRIPPING DIMENSIONS
c
ab
e
4
- Cut the cable end in a hollow ( between two rings)
with a hacksaw.
- Raise the handle and introduce the cable until it
stops in the stripping tool.
- Push down the handle by exerting a light pressure
on it, keep turning the tool until it tu rns freely.
- Hold the handle down, and turn the tool (of
approximately ΒΌ of tour) in the opposite direction,
while pulling gently on the cable in order to release
pieces of the cable cut.
- Raise the handle, slide the cable out and remove
loose pieces of cable.
- In case of cut parts jammed in the tool : raise the
handle, introduce again the stripped cable in the
tool, screw slightly the cable into the copper
previously cut and remove cable + loose parts.
- Push down again the handle.
1
- Introduce the cable in the tool as shown.
- Turn the tool to point the inner conductor of the
cable.
3
- Mount the clamp nut on the cable, until the
clipsage of the elastic contact on the first annelure.
- To push the part defers the tow press in stop on
the elastic contact.
- Mount the clamp nut with the cable in the body of
the connector.
- Couple of tightening recommended: 800 Ncm
- Introduce the cable in the opposite side of the tool.
- Turn the tool and exert a light pressure until stop.
- After cutting the dielectric cut will be extracted on
the other side of the tool.
25
ASSEMBLY INSTRUCTIONS
N
13-63
M 20
Part number Stripping length (mm) a Stripping tool for cable 7/8 corrugated
R161 033 020W 26 R282 011 060
STRIPPING DIMENSIONS
3
- Cut the front extremity of the cable on the summit
of a ring with a hacksaw ("a" dimension).
- Raise the handle and push the cable stops until it.
- Lowered the handle using a light pressure on it.
- Hold the handle down, and turn the tool (of
approximately ΒΌ of tour) in the opposite direction,
while pulling gently on the cable in order to release
pieces of the cable cut.
- Raise the handle, slide the cable out and remove
loose pieces of cable.
- Split the sheath with a cutter, perpendicular to the
previously sp lit.
- Remove the sheath.
1
- Slide the clamp device over the cable, until the
elastic part snap into the first groove of the outer
conductor.
- Push foward the nut of the clamp device until it
stops against the elastic part.
2
- Screw the connector on the nut of the clamp
device.
- Recommended mating torque: 2500 N cm
ASSEMBLY INSTRUCTIONS
13-64
N
M 21
Part number Stripping length (mm) Stripping tool
abce
R161 230 320W 5 16 23.7 2.7 R282 011 050
STRIPPING DIMENSIONS
c
aeb
4
- Cut the cable end in a hollow (between two rings)
with a hacksaw.
- Raise the handle and introduce the cable until it
stops in the stripping tool.
- Push down the handle by exerting a light pressure
on it, keep turning the tool until it turns freely.
- Hold the handle down, and turn the tool (of
approximatel y ΒΌ of tour) in the opp osite directi on,
while pulling gently on the cable in order to release
pieces of the cable cut.
- Raise the handle, slide the cable out and remove
loose pieces of cable.
- In case of cut pa rts jammed in th e to ol : raise the
handle, introduce again the stripped cabl e in the
tool, screw slightly the cable into the copper
previously cut and remove cable + loose parts.
- Push down again the handle.
1
- Introduce the cable in the tool as shown.
- Turn the tool to point the inner conductor of the
cable.
3
- Mount the clamp nut on the cable, until the
clipsage of the elastic contact on the first annelure.
- To push the part defers the tow press in stop on
the elastic contact.
- Mount the clamp nut with the cable in the body of
the connector.
- Couple of tightening recommended: 800 Ncm.
- Introduce the cable in the opposite side of the tool.
- Turn the tool and exert a light pressure until stop.
- After cutting the dielectric cut will be extracted on
the other side of the tool.
25
ASSEMBLY INSTRUCTIONS
N
13-65
M 22
Part number Stripping length (mm) a Stripping tool
R161 231 020W 26 R282 011 060
STRIPPING DIMENSIONS
- Cut the front extremity of the cable on the summit
of a ring with a hacksaw (a dimension).
- Raise the handle and push the cable stops until it.
- Lowered the handle using a light pressure on it.
- Hold the handle down, and turn the tool (of
approximately ΒΌ of tour) in the opposite direction,
while pulling gently on the cable in order to release
pieces of the cable cut.
- Raise the handle, slide the cable out and remove
loose pieces of cable.
- To split the sheath with a tool cutting
perpendiculary to the previously undertaken split.
- To remove the sheath cut.
1
- Slide the clamp device over the cable, until the
elastic part snap into the first groove of the outer
conductor.
- Push foward the nut of the clamp device until it
stops against the elastic part.
2
- Screw the connector on the nut of the clamp
device.
- Recommended mating torque: 2500 Ncm.
3
ASSEMBLY INSTRUCTIONS
NOTES