Timers
S1DXM-A/M
Product types
S1DXM-A multi-range timer
No MODE switch, Operation mode (fixed): Power ON-delay
Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details.
A socket line holding clip (ADX28005) is not included with the product. Please purchase separately.
MULTI-RANGE
ANALOG TIMER S1DXM-A/M
Operating voltage Time range Timed-out 2 Form C Timed-out 4 Form C
Part No. Part No.
12V DC
0.05 s to 10 min S1DXM-A2C10M-DC12V S1DXM-A4C10M-DC12V
0.2 s to 30 min S1DXM-A2C30M-DC12V S1DXM-A4C30M-DC12V
0.5 s to 60 min S1DXM-A2C60M-DC12V S1DXM-A4C60M-DC12V
0.05 min to 10 hr S1DXM-A2C10H-DC12V S1DXM-A4C10H-DC12V
24V DC
0.05 s to 10 min S1DXM-A2C10M-DC24V S1DXM-A4C10M-DC24V
0.2 s to 30 min S1DXM-A2C30M-DC24V S1DXM-A4C30M-DC24V
0.5 s to 60 min S1DXM-A2C60M-DC24V S1DXM-A4C60M-DC24V
0.05 min to 10 hr S1DXM-A2C10H-DC24V S1DXM-A4C10H-DC24V
24V AC *Note
0.05 s to 10 min S1DXM-A2C10M-AC24V S1DXM-A4C10M-AC24V
0.2 s to 30 min S1DXM-A2C30M-AC24V S1DXM-A4C30M-AC24V
0.5 s to 60 min S1DXM-A2C60M-AC24V S1DXM-A4C60M-AC24V
0.05 min to 10 hr S1DXM-A2C10H-AC24V S1DXM-A4C10H-AC24V
100 to 120V AC
0.05 s to 10 min S1DXM-A2C10M-AC120V S1DXM-A4C10M-AC120V
0.2 s to 30 min S1DXM-A2C30M-AC120V S1DXM-A4C30M-AC120V
0.5 s to 60 min S1DXM-A2C60M-AC120V S1DXM-A4C60M-AC120V
0.05 min to 10 hr S1DXM-A2C10H-AC120V S1DXM-A4C10H-AC120V
200 to 220V AC
0.05 s to 10 min S1DXM-A2C10M-AC220V S1DXM-A4C10M-AC220V
0.2 s to 30 min S1DXM-A2C30M-AC220V S1DXM-A4C30M-AC220V
0.5 s to 60 min S1DXM-A2C60M-AC220V S1DXM-A4C60M-AC220V
0.05 min to 10 hr S1DXM-A2C10H-AC220V S1DXM-A4C10H-AC220V
220 to 240V AC *Note
0.05 s to 10 min S1DXM-A2C10M-AC240V S1DXM-A4C10M-AC240V
0.2 s to 30 min S1DXM-A2C30M-AC240V S1DXM-A4C30M-AC240V
0.5 s to 60 min S1DXM-A2C60M-AC240V S1DXM-A4C60M-AC240V
0.05 min to 10 hr S1DXM-A2C10H-AC240V S1DXM-A4C10H-AC240V
Features
• Multiple functions built in
• Part No. consolidation
(The lineup consists of 64 easy-to-
choose models.)
• Cadmium-free contacts used
• Economically priced
• Operation mode and time range
switches are on front panel.
(Operation mode switch on S1DXM-M
series only.)
Time selectable Mode selectable IP40
RoHS compliance
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
S1DXM-A/M
S1DXM-M multi-range timer
With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker OFF start, Power Flicker ON start, Power One-shot
Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details.
A socket line holding clip (ADX28005) is not included with the product. Please purchase separately.
Operating voltage Time range Timed-out 2 Form C Timed-out 4 Form C
Part No. Part No.
12V DC
0.05 s to 10 min S1DXM-M2C10M-DC12V S1DXM-M4C10M-DC12V
0.2 s to 30 min S1DXM-M2C30M-DC12V S1DXM-M4C30M-DC12V
0.5 s to 60 min S1DXM-M2C60M-DC12V S1DXM-M4C60M-DC12V
0.05 min to 10 hr S1DXM-M2C10H-DC12V S1DXM-M4C10H-DC12V
24V DC
0.05 s to 10 min S1DXM-M2C10M-DC24V S1DXM-M4C10M-DC24V
0.2 s to 30 min S1DXM-M2C30M-DC24V S1DXM-M4C30M-DC24V
0.5 s to 60 min S1DXM-M2C60M-DC24V S1DXM-M4C60M-DC24V
0.05 min to 10 hr S1DXM-M2C10H-DC24V S1DXM-M4C10H-DC24V
24V AC *Note
0.05 s to 10 min S1DXM-M2C10M-AC24V S1DXM-M4C10M-AC24V
0.2 s to 30 min S1DXM-M2C30M-AC24V S1DXM-M4C30M-AC24V
0.5 s to 60 min S1DXM-M2C60M-AC24V S1DXM-M4C60M-AC24V
0.05 min to 10 hr S1DXM-M2C10H-AC24V S1DXM-M4C10H-AC24V
100 to 120V AC
0.05 s to 10 min S1DXM-M2C10M-AC120V S1DXM-M4C10M-AC120V
0.2 s to 30 min S1DXM-M2C30M-AC120V S1DXM-M4C30M-AC120V
0.5 s to 60 min S1DXM-M2C60M-AC120V S1DXM-M4C60M-AC120V
0.05 min to 10 hr S1DXM-M2C10H-AC120V S1DXM-M4C10H-AC120V
200 to 220V AC
0.05 s to 10 min S1DXM-M2C10M-AC220V S1DXM-M4C10M-AC220V
0.2 s to 30 min S1DXM-M2C30M-AC220V S1DXM-M4C30M-AC220V
0.5 s to 60 min S1DXM-M2C60M-AC220V S1DXM-M4C60M-AC220V
0.05 min to 10 hr S1DXM-M2C10H-AC220V S1DXM-M4C10H-AC220V
220 to 240V AC *Note
0.05 s to 10 min S1DXM-M2C10M-AC240V S1DXM-M4C10M-AC240V
0.2 s to 30 min S1DXM-M2C30M-AC240V S1DXM-M4C30M-AC240V
0.5 s to 60 min S1DXM-M2C60M-AC240V S1DXM-M4C60M-AC240V
0.05 min to 10 hr S1DXM-M2C10H-AC240V S1DXM-M4C10H-AC240V
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
S1DXM-A/M
Specifications
Notes: *1. Unspecified measuring conditions are rated operating voltage (in case of DC type , ripple rate of 5% or less), ambient temp. 20°C 68°F, and power off time 1 second.
*2. Power one-shot 1 s range: +2% and 10 ms
*3. When using with a transmission wa ve rectification, vibration resistance and shoc k resistance properties worsen compared to when using a stabilized power supply.
Time range setting
Note: The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h).
Example: When dial reads 1, time scale is X1 and time units is seconds, then it is 1 second.
Item Specifications
Rating
Rated operating voltage 24VAC 100 to 120VAC 200 to 220VAC 220 to 240VAC 12VDC 24VDC
Rated frequency 50/60Hz common
Rated power
consumption
Max. 3 VA
(at 24 VAC) Max. 3 VA
(at 100 VAC) Max. 3 VA
(at 200 VAC) Max. 3 VA
(at 220 VAC) Max. 2 W
(at 12 VDC) Max. 2 W
(at 24 VDC)
During time delay Approx. 3mA Approx. 3mA Approx. 3mA Approx. 3mA Approx. 5mA Approx. 3mA
After time delay Approx. 80mA Approx. 20mA Approx. 13mA Approx. 13mA Approx. 70mA Approx. 40mA
Rated control capacity Timed -out 2 Form C: 7A 250V AC (resistive load)
Timed -out 4 Form C: 5A 250V AC (resistive load)
Operation mode
S1DXM-A
Power on delay operation fixed
(Power display: ON/green; Operation display (when output is on): UP/orange)
S1DXM-M
4 switchable operations: Power ON-delay/Power Flicker OFF start/Power Flicker ON start/Power One-shot
(Power display: ON/green; Operation display (when output is on): UP/orange)
Time
accuracy*1
Operating time fluctuation &
Power off time change error Within ±1%, (power off time change at the range of 0.1 s to 1 h), 1 s range: Max. ±1% and 10 ms*2
Voltage error Within ±1% (at the operating voltage changes between –20 to +10%), 1 s range: Max. ±1% and 10 ms*2
Temperature error Within ±5% (at 20°C 68°F ambient temp. at the range of –10 to +50°C +14 to +122°F)
Setting error Within ±10%, 1 s range: Max. ±10% and 20 ms
Contact
Contact arrangement Timed-out 2 Form C, Timed-out 4 Form C
Contact resistance (Initial value) Max. 100m (at 1A, 6V DC)
Contact material Timed-out 2 Form C type: Silver alloy, Au plating
Timed-out 4 Form C type: Silver alloy, Au plating
Life Mechanical (constant) Min. 107
Electrical (constant) 2×105 (at rated control capacity)
Mechanical
Vibration
resistance Functional 10 to 55Hz: 1 cycle/min single amplitude of 0.25mm (10min on 3 axes)
Destructive 10 to 55Hz: 1 cycle/min single amplitude of 0.375mm (1h on 3 axes)
Shock
resistance Functional Min. 98m/s2 (4 times on 3 axes)
Destructive Min. 980m/s2 (5 times on 3 axes)
Electrical
Allowable operating voltage range 19.2 to 26.4 V DC 80 to 132 V AC 160 to 242 V AC 176 to 264 V AC 9.6 to 13.2 V DC 19.2 to 26.4 V DC
Reset time Max. 0.1s
Insulation resistance (Initial value) Between live and dead metal parts, between input and output, between contact sets, between contacts
Min. 100 M (at 500 V DC megger)
Breakdown voltage (Initial value)
Between live and dead metal parts: 2,000 Vrms for 1 min
Between input and output: 2,000 Vrms for 1 min
Between contact sets: 2,000 Vrms for 1 min
Between contacts: 1,000 Vrms for 1 min
Temperature rise Max. 70°C 158°F
Operating
conditions
Ambient temperature –10 to 50°C +14 to 122°F
Ambient humidity 30 to 85% RH (non-condensing)
Air pressure 860 to 1060 hPa
Ripple factor DC type only, transmission wave rectification (ripple factor: approx. 48%)*3
Mass (Weight) Approx. 45 g
Protective construction IEC standard: IP40 (IP50 when using ADX18008 protective cover)
Type Time scale Time unit Min. scale Max. scale Setting range
S1DXM-A
10M type
X1 X10
sm0.05 1 0.05 to 1s 0.5 to 10s 0.05 to 1m 0.5 to 10m
30M type s m 0.2 3 0.2 to 3s 2 to 30s 0.2 to 3m 2 to 30m
60M type s m 0.5 6 0.5 to 6s 5 to 60s 0.5 to 6m 5 to 60m
10H type m h 0.05 1 0.05 to 1m 0.5 to 10m 0.05 to 1h 0.5 to 10h
S1DXM-M
10M type
X1 X10
sm0.05 1 0.05 to 1s 0.5 to 10s 0.05 to 1m 0.5 to 10m
30M type s m 0.2 3 0.2 to 3s 2 to 30s 0.2 to 3m 2 to 30m
60M type s m 0.5 6 0.5 to 6s 5 to 60s 0.5 to 6m 5 to 60m
10H type m h 0.05 1 0.05 to 1m 0.5 to 10m 0.05 to 1h 0.5 to 10h
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
S1DXM-A/M
Operation mode and Time range setting
Operation mode
S1DXM-A multi-range timer
Power ON-delay operation
When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off.
S1DXM-M multi-range timer
* When the power is repeatedly turned on and off, the UP (Operation) LED may light up briefly when power is applied. This is not a malfunction.
Notes: 1. The product is factory shipped with all settings on the OFF side (left).
2. Do not operate the switches with a sharp-edged object such as a knife
blade.
3. The power must be turned off when setting the time range or operation
mode. Operating the switches with the po wer on is a cause of breakdo wn
and malfunction.
4. Use a force of under 5 N to operate the DIP switches when setting the time
range and operation mode.
Operation mode switchOperation mode
Power ON-delay
Power Flicker OFF start
Power Flicker ON start
Power One-shot
1ON
2
1ON
2
1ON
2
1ON
2
Time range switch
The time setting can be switched among 4
ranges each for 4 types for an interval between
0.05 seconds and 10 hours.
s
(m) m
(h)
X1 X10
T
T: Setting time
Power supply
Time chart
Timed-out contact (NO)
UP (operation) LED
ON (power) LED (orange)
OFF
(green)
ON
OFF
ON
Power ON-delay operation
[MODE] switch 1: OFF, switch 2: OFF
When power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.
Power Flicker OFF start operation
[MODE] switch 1: OFF, switch 2: ON
When the power is turned on, the output contacts repeatedly operate at
the set time. The output contact begins from the off state.
T
T: Setting time
Power supply
Time chart
Timed-out contact (NO)
UP (operation) LED
ON (power) LED (orange)
OFF
(green)
ON
OFF
ON
TTTTTTt
t < T
T: Setting time
Power supply
Time chart
Timed-out contact (NO)
ON (power) LED
UP (operation) LED (orange)
OFF
(green)
ON
OFF
ON
Power Flicker ON start operation
[MODE] switch 1: ON, switch 2: OFF
When power is turned on, the output contact operates repeatedly at the
set time. The output contact outputs at the same time power turns on.
Power One-shot operation
[MODE] switch 1: ON, switch 2: ON
When power is turned on, the output contact performs the on operation
at the same time power turns on, only for the set time.
TTTTTTt
t < T
T: Setting time
Power supply
Time chart
Timed-out contact (NO)
ON (power) LED
UP (operation) LED (orange)
OFF
(green)
ON
OFF
ON
T
T: Setting time
Power supply
Time chart
Timed-out contact (NO)
ON (power) LED
UP (operation) LED (orange)
OFF
(green)
ON
OFF
ON
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
S1DXM-A/M
Part names
Dimensions (mm inch)
Time range
switch Time range
switch
Setting dial
Operation LED
(orange)
Power LED
(green)
Setting
hand
Control time
scale
S1DXM-MS1DXM-A Operation
mode switch
• [RANGE] Time range switch
(4 different time ranges can be switched.)
• [MODE] Operation mode switch
(4 different operation modes can be switched.)
Power ON-delay
Power Flicker OFF start
Power Flicker ON start
Power One-shot
10M type:
30M type:
60M type:
10H type:
1 s/10 s/1 min/10 min
3 s/30 s/3 min/30 min
6 s/60 s/6 min/60 min
1 min/10 min/1 hr/10 hr
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
S1DXM-A
Terminal layouts and Wiring diagram
Timed-out 2 Form C type
Timed-out 4 Form C type
* For the DC operating type, terminal 14 is “+” and terminal 13 is “–”.
ON UP
sm
RANGE
X1
X10
0
S1DXM
Time range switch
ON (Power) LED (green)
Nameplate
For 4 Form C type
28.5
1.122 16.6
.654
Control time scale
UP (Operation) LED (orange)
22.1
.870
6.4
.252
57.9
2.280
52.7
2.075
1
5
9
13
4
8
12
14
Operating
voltage
13.35
.526
1
5
9
2
6
10
3
7
11
13
4
8
12
14
Operating
voltage
5.1
.201 4.1
.161
6.4
.252 6.4
.252
13.35
.526
.175
4.45
Note: Please also refer to “PRECAUTIONS IN USING S1DXM-A/M AND S1DX” on page 68.
S1DXM-M
ON UP
MODE ON
sm
RANGE
X1
X10
2
1
0
S1DXM
Time range switch
Operation mode switch
ON (Power) LED (green)
Nameplate
For 4 Form C type
Control time scale
UP (Operation) LED (orange)
22.1
.870
28.5
1.122
6.4
.252
57.9
2.280
52.7
2.075
16.6
.654
CAD Data Tolerance: ±0.5 ±.020
CAD Data
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Options
S1DXM-A/M/S1DX COMMON OPTIONS
Accessory (Unit: mm inch)
• Mounting frame (for panel mounting type)
Terminal socket
Socket leaf holding clip
S1DXM-A/M/S1DX COMMON OPTIONS
ADX18002 (Titanium-gray)
ADX18006 (Gray)
ADX18007 (Black)
Panel cutout dimensions
Board thickness 1 to 3 mm
Note: Make sure the holes area stays
as right angles.
27.1
33.5
3
30 31.5
25.1
1.067
1.319
.118
1.181 1.240
.988 +0.2
0 5
3
25.2+.008
0
.992
+0.2
0
31.6+.008
0
1.244 *Note
.197
.118
• Protective cover
ADX18008
• Cap block
ADX18011
• Cap for cap block
ADX18004
• Socket for cap block
ADX18003
28.2
34.6
10.5
1.110
1.362
.413
30.0
36 1.417
21.2
.835
1.181
29.4
18.85
21.2
7.65
2.079
1.157
.742
.835
.301
• HC2 slim DIN
terminal socket
HC2-SFD-S
• HC2 DIN high
terminal socket
HC2-SFD-K
• HC4 DIN high
terminal socket
HC4-SFD-K
• HC4 socket
HC4-SS-K
• HJ2 terminal
socket
HJ2-SFD/HJ2-SFD-S
• HJ4 terminal
socket
HJ4-SFD/HJ4-SFD-S
3.248
82.5
86.5
3.406
3.248
82.5
86.5
3.406
3.248
82.5
86.5
3.406
10
.394
58.1
2.287
86.0
3.386
88.0
3.465
86.0
3.386
88.0
3.465
Notes: The triangles indicate that removal will be slightly difficult when installed laterally in
succession.
*1. The socket line holding clip ADX18005 is enclosed in the S1DX timer.
: Available, –: Not available
*2. The socket line holding clip (ADX28005) is not included with the S1DXM-A/M
timer.
*3. For use where there is a lot of vibration and shock, please use a compliant
socket leaf holding clip or socket line holding clip.
Type Application
Terminal
socket ADX18001 ADX18012 AD68002 ADX28005 ADX18005
For
HC
relay
HC2-SFD-S*3––
HC2-SFD-K*3
HC4-SFD-K*3
HC2-SF-K 
HC4-HSF-K 
HC2-SS-K 
HC4-SS-K 
For
HJ
relay
HJ2-SFD*3–––
HJ2-SFD-S*3–––
HJ4-SFD*3–––
HJ4-SFD-S*3–––
*2
*1
(2 pieces per set)
63.8
2.512
4.5
.177
ADX18001 ADX18012
DimensionsAppearance DimensionsAppearance
(2 pieces per set) (2 pieces per set)
63.1
2.484
4.5
.177
61.6
2.425
4.5
.177
AD68002
DimensionsAppearance
ADX28005
52.6
2.071
7.5
.295
Socket line holding clip
for S1DXM-A/M
(Sold separately)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Options
S1DXM-A/M/S1DX COMMON OPTIONS
HC relay terminal sockets
Name/Model No.
• Terminal socket, HC
2-pin
HC2-SF-K
Available Not
available
Dimensions Terminal layout Mounting hole dimensions Applicable timers
S1DX(2c)
S1DXM(2c) S1DX(4c)
S1DXM(4c)
6.2
.244
30
1.181
Oval hole: 2-4.2×5
.165×.197
12
.472
15
.591
40
1.575
5
.197
17.5
.689
Terminal screw M3
4
1
81214
5913
• High terminal socket,
HC 1-, 2- and 4-pin
HC4-HSF-K
Available Available
For general rails
67
2.638
53.5
2.106
30
1.181
6.2
.244 9
.354
Oval hole: 2-4.2×9
.165×.354
22.5
.886
Screw
hole
size
27.8
1.094
16
.630
8
.315
28.6
1.126
Terminal screw M3
37
48
1
11
12
14
5913
6210
• Slim DIN terminal
socket, HC2
HC2-SFD-S
Available Not
available
Terminal screw M3
0.3
57
6.4±0.2
.252±.008 8±0.2
.315
±.008
22±0.6
.866±.024
4.2
±
20.15
±
.079 .006
±0.3
.165±.012
6.2±.012
.244±
4.1
±
6.3
±0.2
.161±.008
0.2
±
.248 .008
15
13.5
±0.6
.591±.024
±0.2
.531±.008
67±1
2.638
±.039
6
0.6
28.5±.024
1.122±
±0.3
.236±.012
35.4
±1
2.244±.039
0.6
20±
.024
.787±
±0.5
1.394±.020
8
12
14 13
9
5
14
2 .079
22
.866 22
.866
0.2
15±
.008
.591±
0.2
15±
.008
.591±
9 .354
67
2.638
0.5
57±
.020
2.244
±
Screw hole: 2-M3.5
(or 4.2±0.1 hole)
φ
(or .165±.004 hole)
φ
• DIN high terminal
socket, HC2
HC2-SFD-K
Available Not
available
30
6
.236 ±0.6
1.181±.024
4.1±0.2
.161±.008
6.4±0.2
.252±.008
6.3±0.2
.248±.008
2±0.15
.079±.006
13.35±0.2
.526±.008
26±0.6
1.024±.024
0.3
4.2±.012
.165±
67±1
2.638±.039
Terminal screw M3
21±0.6
.827±.024
41
14
12
8
13
9
5
4 .157
26
30
26
1.024 1.024
30
1.181 1.181
33.5
1.319
67
2.638
10 .394
Screw hole: 2-M3.5
(or 4.2±0.1 hole)
φ
(or .165±.004 hole)
φ
• DIN high terminal
socket, HC4
HC4-SFD-K
Available Available
For DIN rails
30±0.6
1.181±.024
6
.236
6.4±0.2
.252±.008 2±0.15
.079±.006
4.1±0.2
.161±.008
6.3±0.2
.248±.008
26
13.35
4.45
±0.6
1.024±.024
±0.2
.526±.008
±0.2
.175±.008
0.3
4.2±.012
.165±
67±1
2.638±.039
Terminal screw M3
21±0.6
.827±.024
12
14
8
11 10 9
13
765
4321
Drilling size of panel holes for installing
the terminal sockets parallel
Note)
Only socket line holding clips can be used.
(Socket leaf holding clip cannot be used.)
Note)
Only socket line holding clips can be used.
(Socket leaf holding clip cannot be used.)
.472 .472.906
12 1223
40
1.575
30 30
1.181 1.181
5
.197
2-M.138 screw hole
(or .165±.004 dia. hole)
2-M3.5 screw hole
(or 4.2±0.1 dia. hole)
Panel hole dimensions for
side-by-side mounting
22.5 22.5
.886 .886
53.5
2.106
2.638
67
30 30
1.181 1.181
5
.197
12.5 .492
2-M.138 screw hole
(or .165±.004 dia. hole)
2-M3.5 screw hole
(or 4.2±0.1 dia. hole)
Panel hole dimensions for
side-by-side mounting
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Options
S1DXM-A/M/S1DX COMMON OPTIONS
HJ relay terminal sockets
Name/Model No.
• HJ2 terminal socket
HJ2-SFD
Available Not
available
Dimensions Terminal layout Mounting hole dimensions Applicable timers
S1DX(2c)
S1DXM(2c) S1DX(4c)
S1DXM(4c)
1314
912
85
41
M3 .118
terminal screw
2-M4.2×5 .165×5
mounting holes
30
1.181
22
.866
59±1
2.323±.039
72±1
2.835±.039 35.4
1.394
4
.157
16.5
.650 3.4±0.3
.134±.012
6±0.3
.236±.012
41
85
912
1314
15±0.2
.591±.008
59±0.3
2.323±.012
2-M3 .118 or M4 .157
or 4.5 .177 dia. hole
• HJ2 terminal socket
(Finger protect type)
HJ2-SFD-S
Available Not
available
1314
912
85
41
M3 .118
terminal screw
2-M4.2×5 .165×5
mounting holes
59±1
2.323±.039
72±1
2.835±.039
30
1.181
16.5
.650 3.4±0.3
.134±.012
35.4
1.394
4
.157
6±0.3
.236±.012
22
.866
41
85
912
1314
• HJ4 terminal socket
HJ4-SFD
Available Available
87
3
9
1
56
2
1112
144
10
13 Lot No.
30
1.181
16.5
.650 3.4±0.3
.134±.012
35.4±0.5
1.394±.020
6±0.3
.236±.012
M3 .118
terminal screw
2-M4.2×5 .165×5
mounting holes
59±1
2.323±.039
72±1
2.835±.039
29
1.142
123
7658
12 11 10 9
13
144
2-M3 .118 or M4 .157
or 4.5 .177 dia. hole
59±0.3
2.323±.012
22±0.2
.866±.008
• HJ4 terminal socket
(Finger protect type)
HJ4-SFD-S
Available Available
87
3
9
1
56
2
1112
144
10
13 Lot No.
30
1.181
18
.709 3.4±0.3
.134±.012
35.4
1.394
4
.157
6±0.3
.236±.012
M3 .118
terminal screw
2-M4.2×5 .165×5
mounting holes
59±1
2.323±.039
72±1
2.835±.039
29
1.142
123
7658
12 11 10 9
13
144
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Options
S1DXM-A/M/S1DX COMMON OPTIONS
Sockets
• Sockets for PC board
HC2-Socket for PC board: HC2-PS-K
HC4-Socket for PC board: HC4-PS-K
29.4
1.157
910
13
1
52
6
1211
14
4
8
3
7
7.06
.278
16.55
.652
2.3
.091
7.65
.301
21.2
.835
25.5
1.004
4.06
.160
6.35
.250
.250
6.35
25.2
.992 1.27
.050
.175 .175
4.45 4.45
.175
4.45
Name/Model No.
• Socket, HC 2-pin
HC2-SS-K
Available Not
available
Dimensions Mounting hole dimensions Applicable timers
S1DX(2c)
S1DXM(2c) S1DX(4c)
S1DXM(4c)
• Socket, HC 4-pin
HC4-SS-K
Available Available
21.2
.835
29.4
1.157
5876
9
13
10 12
14
11
12 43
7.06
.278
4.06
.160
16.55
.652
6.35
.250
6.35
.250
2.3
.091
25.2
.992
7.65
.301
25.5
1.004
1.27
.050
.175
.175
4.45
.175
4.45 4.45
parallel installed.
25.8
1.016
21.6
.850 5.9
.232
The interval size between
the sockets which are
• The difference between the HC2 and HC4 sockets is
only the number of the pins. Their appearances and
sizes are the same.
General tolerance: ±0.5
Dimensional tolerance of machining: ±0.1 ±.004
±.020
• The thickness of applicable chassis plates ranges
from 1.0 to 2.0 mm .039 to .079 inch.
• To install the socket easily, insert the socket top
surface into the drilled holes and press the two points
on the fastening plate indicated by arrows as shown in
the fig. below.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
PRECAUTIONS IN USING S1DXM-A/M AND S1DX
Applicable standard
PRECAUTIONS IN USING S1DXM-A/M AND S1DX
Safety standard EN61812-1 Pollution Degree 2/Overvoltage Category II (2 Form C type)
Pollution Degree 1/Overvoltage Category II (4 Form C type)
EMC
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
RF electromagnetic field immunity
EFT/B immunity
Surge immunity
Conductivity noise immunity
Power frequency magnetic field immunity
Voltage dip/Instantaneous stop/Voltage fluctuation immunity
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2 4 kV contact
8 kV air
EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (895 MHz to 905 MHz)
EN61000-4-4 2 kV (power supply line)
1 kV (signal line)
EN61000-4-5 1 kV (power supply line)
EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz)
EN61000-4-8 30 A/m (50 Hz)
EN61000-4-11 10 ms, 30% (rated voltage)
100 ms, 60% (rated voltage)
1,000 ms, 60% (rated voltage)
5,000 ms, 95% (rated voltage)
Reset periods
After unscheduled operations have been
completed, or if the timer operation pow er
supply has been turned off at any time
during operation, a reset period of at
least 0.1 seconds should be allowed
before resuming operation.
External surge protection
External surge protection may be
required if the following values are
exceeded. Otherwise, the internal circuit
will be damaged. The typical surge
absorption elements include a varistor, a
capacitor, and a diode. If a surge
absorption element is used, use an
oscilloscope to see whether or not the
foreign surge exceeding the specified
value appears.
Single-pole, full-wave voltage for surge
waveform [±(1.2 × 50) µs]
Since the main body cover and knob are
made of polycarbonate resin, prevent
contact with organic solvents such as
methyl alcohol, benzine and thinner, or
strong alkali materials such as ammonia
and caustic soda.
Terminal wiring
Make sure that terminals are wired
carefully and correctly, referring to the
terminal layout and wiring diagrams.
Particularly, since the DC type has
polarity, do not operate it with reverse
polarity.
Assembly
1) When installing, use a terminal socket
or socket intended for HC/HJ relay. For
adjacent installations, be sure to first
verify the installation conditions of the
terminal sockets or sockets you will be
using.
2) Use the separately-sold dedicated
sock et leaf holding clip to secure terminal
sock ets and sock ets to the timer unit. The
conditions of use for dedicated socket
leaf holding clip will differ depending on
the terminal socket or socket you will be
using. Theref ore, please test under actual
conditions before putting into operation.
3) If terminals are to be soldered directly,
please hand solder with a 30 to 60 W
solder iron with a tip temperature of
300°C for no more than 3 seconds.
Automatic soldering should be avoided.
4) A flux-tight construction is not used
with this timer, so be careful that flux or
cleaning fluid does not get inside the
case.
5) To assure that characteristics are
maintained, do not remove the case.
Long Continuous Current Flow
Long continuous current flow through the
timer cause generation of heat internally,
which degrade the electronic parts. Use
the timer in combination with a relay and
avoid long continuous current flow
through the timer. (Refer to the circuit
diagram below when using a safety
circuit for continuous operation.)
Phase synchronization using AC
load
If the turning on of the timer output relay
is synchronized to the AC power supply
phase, there may be times when the
service life is shortened because of
electrical factors, or when a locking
phenomenon (defective relay return)
occurs because of contact point welding
or a shift in the contact relay. Check the
operation using the actual timer.
Acquisition of CE marking
Please abide by the conditions below
when using in applications that comply
with EN61812-1.
1) Overvoltage category II,
pollution degree 2 (2 Form C type)
Overvoltage category II,
pollution degree 1 (4 Form C type)
2) The load connected to the output
contact should have basic insulation.
This timer is protected with basic
insulation and can be double-insulated to
meet EN/IEC requirements by using
basic insulation on the load.
3) Please use a power supply that is
protected by an overcurrent protection
device which complies with the EN/IEC
standard (example: 250 V 1 A fuse, etc.).
4) You must use a terminal socket or
socket for the installation. Do not touch
the terminals or other parts of the timer
when it is powered. When installing or un-
installing, make sure that no voltage is
being applied to any of the terminals.
5) Do not use this timer as a safety
circuit. F or e xample when using a timer in
a heater circuit, etc., provide a protection
circuit on the machine side.
Operation voltage Surge voltage
100 to 120V AC, 200 to 220V AC 4,000V
12V DC, 24V DC 1,000V
100
90
50
30
00 1.2 50
Time (µs)
Peak
Surge voltage (%)
R
TR
T
R
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timers
PRECAUTIONS IN USING S1DXM-A/M AND S1DX
Others
1) When setting the time, the dial should
be kept within the range indicated on the
dial face. The “0” marking on the dial
indicates the minimum time during which
the control time can be varied (it does not
indicate 0 seconds).
2) Do not rotate the knob past the
stopper.
3) Turn off the power bef ore changing the
DIP switch settings. Changing the DIP
switch with the power on can cause
breakdown.
4) When connecting the operating power
supply, make sure that no leakage
current enters the timer. For example,
when perf orming contact protection, if set
up like that of fig. A, leaking current will
pass through C and R, enter the timer,
and cause incorrect operation. The fig. B
shows the correct setup.
When a contact switch having an
operation indicating lamp (lamp equipped
limit switch, etc.) is used to apply power
to the timer, a resistor having a value
equal to or greater than the value below
shall be connected in series with the
lamp.
100 to 120V AC operating type:
Min. 33k
200 to 220V AC operating type:
Min. 82k
T
T
CR
(Fig. A)
(Fig. B)
Operating power supply
Leakage current
R
C
Operating power supply
WRONG
CORRECT
T
Resistor Neon lamp
Limit switch
Example of limit switches
with lamp.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.