4
G6RL PCB Power Relay
■Approved Standards
The approval ratings for overseas models are different from the performance values determined individually. Confirm the values before
use.
●UL/C-UL Recognized: (File No. E41643)UL508/CSA22.2 No.14
Note.CSA standards: Certified by C-UL.
●EN/IEC, VDE Certified: (EN61810-1) (Certificate No. C266)
●EN/IEC, VDE Certified: (EN 60947-5-1) (Certificate No. C266)
●EN/IEC, VDE Certified: (EN60947-4-1) (Certificate No. C266)
●EN/IEC, VDE Certified: (EN60730-1) (Certificate No. 40021033)
●EN/IEC
Note. Basic requirements of EMC directives (EMI standard No., EMS standard No., Certification Body, File No., Applicable time) … not applicable.
Models Contact from Coil ratings Contact ratings Number of test operations
G6RL-1A SPST-NO (1a)
3 to 48 VAC
10 A, 250 VAC (NO) (Resistive) 85°C
8 A, 250 VAC (Resistive) 85°C
5 A, 30 VDC (Resistive) 85°C
6,000
G6RL-1 SPDT (1c)
G6RL-1A(4)-ASI SPST-NO (1a)
G6RL-1(4)-ASI SPDT (1c)
Models Contact from Coil ratings Contact ratings Number of test operations
G6RL-1A-(ASI) SPST-NO (1a)
3, 5, 6, 12, 24, 48 VDC
10 A, 250 VAC (NO) 85°C 10,000
G6RL-1-(ASI) SPDT (1c) 8 A, 250 VAC 85°C 30,000
5 A , 30 VDC 85°C 50,000
G6RL-1A4-ASI SPST-NO (1a)
3, 5, 6, 12, 24, 48 VDC
10 A, 250 VAC (NO) 85°C
10,000
G6RL-14-ASI SPDT (1c) 8 A, 250 VAC 85°C
5 A, 30 VDC 85°C
Models Contact ratings Number of test operations
G6RL-1(A)(4)
AC15 (NO) AC240, 3 A, cos ϕ 0.3, Room temperaure
6,000
DC13 DC125, 0.22A, 165ms, Room temperaure
DC13 DC250, 0.1A, 150ms, Room temperaure
G6RL-1(A)-ASI
AC15 AC240, 3 A, cos ϕ 0.3, Room temperaure
DC13 DC125, 0.22A, 165ms, Room temperaure
DC13 DC250, 0.1A, 150ms, Room temperaure
G6RL-1(A)4-ASI AC15 AC240, 3 A, cos ϕ 0.3, Room temperaure
DC13 DC125, 0.22A, 165ms, Room temperaure
Models Contact ratings Number of test operations
G6RL-1(A)
G6RL-1(A)-ASI
AC1 AC250V
8 A 85°C
6,000
AC3 AC250V
2 A 85°C
DC1 DC24V
5 A 85°C
DC3 DC24V
2 A 85°C
Models Coil ratings Contact ratings Number of test operations
G6RL-1(A)
3, 5, 6, 12, 24, 48 VDC
2 (2) A AC250V 65°C
100,000
6 (4) A (NC) AC250V 65°C
8 (4) A (NO) AC250V 85°C
G6RL-1(A)-ASI
2 (2) A AC250V 65°C
6 (4) A (NC) AC250V 65°C
8 (4) A (NO) AC250V 85°C
Models CE Marking Applicable Safety Category Basic Requirements of Machinery Directive/Low-voltage Directive
Applicable Standard No. Application Standard No.
G6RL −1 EN61810-1 −
Creepage distance 10 mm
Clearance distance 10 mm
Insulation material group IIIa
Rated Insulation Voltage 250 V
Pollution degree 32
Rated voltage system 250 V 400 V
Overvoltage category III II
Tracking Index of relay base PTI 250 V min. (housing parts)
Flammability class according to UL94 V-0
Ball pressure test (IEC 60695-10-2) 170°C