DESCRIPTION The TruStability Standard Accuracy Silicon Ceramic (SSC) Series is a piezoresistive silicon pressure sensor offering a digital output for reading pressure over the specified full scale pressure span and temperature range. The SSC Series is fully calibrated and temperature compensated for sensor offset, sensitivity, temperature effects, and non-linearity using an on-board Application Specific Integrated Circuit (ASIC). Calibrated output values for pressure are updated at approximately 2 kHz. The SSC Series is calibrated over the temperature range of -20 C to 85 C [-4 F to 185 F]. The sensor is characterized for operation from a single power supply of either 3.3 Vdc or 5.0 Vdc. FEATURES Industry-leading long-term stability Extremely tight accuracy of 0.25% FSS BFSL (Full Scale Span Best Fit Straight Line) Total error band of 2% full scale span maximum Modular and flexible design offers customers a variety of package styles and options, all with the same industryleading performance specifications Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package Low operating voltage Extremely low power consumption 2 I C- or SPI- compatible 14-bit digital output (min. 12-bit sensor resolution) These sensors measure absolute, differential, and gage pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Differential versions allow application of pressure to either side of the sensing diaphragm. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. (R) The TruStability pressure sensors are intended for use with non-corrosive, non-ionic gases, such as air and other dry gases. An available option extends the performance of these sensors to non-corrosive, non-ionic liquids. All products are designed and manufactured according to ISO 9001 standards. Precision ASIC conditioning and temperature compensated over -20 C to 85 C [-4 F to 185 F] temperature range RoHS compliant Virtually insensitive to mounting orientation Internal diagnostic functions increase system reliability Also available with analog output Absolute, differential, and gage types Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) Custom calibration available Various pressure port options Liquid media option POTENTIAL APPLICATIONS Medical: Airflow monitors Anesthesia machines Blood analysis machines Gas chromatography Gas flow instrumentation Kidney dialysis machines Oxygen concentrators Pneumatic controls Respiratory machines Sleep apnea equipment Ventilators Industrial: Barometry Flow calibrators Gas chromatography Gas flow instrumentation HVAC Life sciences Pneumatic controls 1 Table 1. Absolute Maximum Ratings Parameter Supply voltage (Vsupply) Voltage on any pin Digital interface clock frequency: 2 IC SPI ESD susceptibility (human body model) Storage temperature Soldering time and temperature: Lead solder (SIP, DIP) Peak reflow (SMT) Min. -0.3 -0.3 Max. 6.0 Vsupply + 0.3 Unit Vdc V 100 50 3 -40 [-40] 400 800 kHz 85 [185] kV C [ F] 4 s max. at 250 C [482 F] 15 s max. at 250 C [482 F] Table 2. Operating Specifications Parameter 2 Supply voltage (Vsupply) : 3.3 Vdc 5.0 Vdc Min. Typ. Max. Unit 3.0 4.75 3.3 3 5.0 3.6 5.25 Vdc 1.6 2 2.1 3 85 [185] 85 [185] 7.3 3 Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected. Supply current: 3.3 Vdc supply 5.0 Vdc supply 4 Compensated temperature range 5 Operating temperature range Startup time (power up to data ready) Response time 2 I C voltage level low 2 I C voltage level high Pull up on SDA and SCL 6 Accuracy 7 Total error band Output resolution 2 www.honeywell.com/sensing -20 [-4] -40 [-40] 0.8 1 12 2.8 0.46 - 0.2 0.25 2 mA C [ F] C [ F] ms ms Vsupply Vsupply kOhm %FSS BFSL 8 %FSS bits Table 3. Environmental Specifications Parameter Humidity: Dry gases only (See "Options N and D" in Figure 1.) Liquid media (See "Options T and V" in Figure 1.) Vibration Shock 9 Life Solder reflow Table 4. Wetted Materials Parameter Covers Substrate Adhesives Electronic components Characteristic 0% to 95% RH, non-condensing 100% condensing or direct liquid media on Port 1 MIL-STD-202F, Curve AK (20.7 g random) MIL-STD-202F, Method 213B, Condition F 1 million cycles minimum J-STD-020-C 10 Port 1 (Pressure Port) high temperature polyamide alumina ceramic epoxy, silicone ceramic, glass, solder, silicon Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, silicone silicon, glass, gold, solder Notes: 1. Absolute maximum ratings are the extreme limits the device will withstand without damage. 2. Ratiometricity of the sensor (the ability of the digital device to maintain performance parameters independent of supply voltage) is achieved within the specified operating voltage for each option. 3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits. 5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not remain within the specified performance limits. 6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. (See Figure 1 for ranges.) 9. Life may vary depending on specific application in which sensor is utilized. 10. Contact Honeywell Customer Service for detailed material information. CAUTION PRODUCT DAMAGE Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids. (R) Ensure liquid media contains no particulates. All TruStability sensors are dead-ended devices. Particulates can accumulate inside the sensor, causing damage or affecting sensor output. Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to enter and settle within the pressure sensor if it is in this position. Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a dead-ended sensor is difficult and has limited effectiveness for removing residue. Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and may lead to sensor failure. Failure to comply with these instructions may result in product damage. Honeywell Sensing and Control 3 Figure 1. Nomenclature and Order Guide SSC _ _ _ _ _ _ _ _ _ _ A _ Supply Voltage 3 = 3.3 Vdc 5 = 5.0 Vdc Series Package D = DIP (Dual Inline Pin) M = SMT (Surface Mount Technology) S = SIP (Single Inline Pin) Transfer Function11 A = 10% to 90% of Vsupply Pressure Port (* indicates not available) DIP SMT NN = No ports NN = No ports * * SIP NN = No ports AA = Dual axial barbed ports, opposite sides AN = Single axial barbed port AN = Single axial barbed port AN = Single axial barbed port LN = Single axial barbless port LN = Single axial barbless port LN = Single axial barbless port * * FF = Fastener mount, dual axial barbed ports, opposite sides * * FN = Fastener mount, single axial barbed port * GN = Ribbed fastener mount, single axial barbed port * * * NB = Fastener mount, dual axial ports, same side RN = Single radial barbed port RN = Single radial barbed port RN = Single radial barbed port RR = Dual radial barbed ports, same side RR = Dual radial barbed ports, same side RR = Dual radial barbed ports, same side DR = Dual radial barbed ports, opposite sides DR =Dual radial barbed ports, opposite sides DR = Dual radial barbed ports, opposite sides * * HH = Fastener mount, dual radial barbed ports, same side * * HN = Fastener mount, single radial barbed port * * MN = Manifold mount, outer diameter seal * * SN = Manifold mount, inner diameter seal Output Type12 S = SPI (not available in SIP package) 2 = I2C, Address 0x28 3 = I2C, Address 0x38 4 = I2C, Address 0x48 5 = I2C, Address 0x58 6 = I2C, Address 0x68 7 = I2C, Address 0x78 Pressure Range13, 14 1 psi to 150 psi Absolute 015PA = 0 psi to 15 psi 030PA = 0 psi to 30 psi 060PA = 0 psi to 60 psi 100PA = 0 psi to 100 psi 150PA = 0 psi to 150 psi Differential 001PD = 1 psi 005PD = 5 psi 015PD = 15 psi 030PD = 30 psi 060PD = 60 psi Gage 001PG = 0 psi to 1 psi 005PG = 0 psi to 5 psi 015PG = 0 psi to 15 psi 030PG = 0 psi to 30 psi 060PG = 0 psi to 60 psi 100PG = 0 psi to 100 psi 150PG = 0 psi to 150 psi 60 mbar to 10 bar Absolute 001BA = 0 bar to 1 bar 1.6BA = 0 bar to 1.6 bar 2.5BA = 0 bar to 2.5 bar 004BA = 0 bar to 4 bar 006BA = 0 bar to 6 bar 010BA = 0 bar to 10 bar Differential 060MD = 60 mbar 100MD = 100 mbar 160MD = 160 mbar 250MD = 250 mbar 400MD = 400 mbar 600MD = 600 mbar 001BD = 1 bar 1.6BD = 1.6 bar 2.5BD = 2.5 bar 004BD = 4 bar Gage 060MG = 0 mbar to 60 mbar 100MG = 0 mbar to 100 mbar 160MG = 0 mbar to 160 mbar 250MG = 0 mbar to 250 mbar 400MG = 0 bar to 400 mbar 600MG = 0 bar to 600 mbar 001BG = 0 bar to 1 bar 1.6BG = 0 bar to 1.6 bar 2.5BG = 0 bar to 2.5 bar 004BG = 0 bar to 4 bar 006BG = 0 bar to 6 bar 010BG = 0 bar to 10 bar Options15 N = Dry gases only, no special options D = Dry gases only, diagnostics on T = Liquid media on port 1, no diagnostics V = Liquid media on port 1, diagnostics on Notes: 11. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and Pmax., the complete transfer function of the sensor is defined. See Figure 2 for a graphical representation of the transfer function. Other transfer functions are available. Contact Honeywell Customer Service for more information. 12. Analog output is also available. Contact Honeywell Customer Service for more information. 13. Custom pressure ranges are available. Contact Honeywell Customer Service for more information. 14. See Table 5 for an explanation of sensor pressure types. 15. See CAUTION on previous page. 4 www.honeywell.com/sensing Figure 2. Transfer Function Limits Figure 3. Completed Catalog Listing Example SSCSANN100PGSA3 SIP package, AN pressure port, no diagnostics, 100 psi gage, SPI output, 10% to 90% calibration at 3.3 Vdc. Table 5. Pressure Types Pressure Type Absolute Differential Gage Description Output is proportional to the difference between applied pressure and a built-in reference to vacuum. Pmin. is set at absolute zero pressure (full vacuum). Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2) 50% point of transfer function set at Port 1 = Port 2. Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Pmin. is set at atmospheric pressure. Table 6. Sensor Output at Significant Percentages % Output Digital Counts (decimal) 0 0 10 1638 50 8192 90 14746 100 16383 Digital Counts (hex) 0x0000 0x0666 0x2000 0x399A 0x3FFF Table 7. Pressure Range Specifications for 1 psi to 150 psi Pressure Range Order Code Pmin. Pmax. 015PA 030PA 060PA 100PA 150PA 0 psi 0 psi 0 psi 0 psi 0 psi 15 psi 30 psi 60 psi 100 psi 150 psi 001PD 005PD 015PD 030PD 060PD -1 psi -5 psi -15 psi -30 psi -60 psi 1 psi 5 psi 15 psi 30 psi 60 psi 001PG 005PG 015PG 030PG 060PG 100PG 150PG 0 psi 0 psi 0 psi 0 psi 0 psi 0 psi 0 psi 1 psi 5 psi 15 psi 30 psi 60 psi 100 psi 150 psi Over16 pressure Absolute 30 psi 60 psi 120 psi 250 psi 250 psi Differential 10 psi 30 psi 30 psi 60 psi 120 psi Gage 10 psi 30 psi 30 psi 60 psi 120 psi 250 psi 250 psi Burst 17 Pressure Common Mode 18 Pressure Long-term Stability (1000 hr, 25 C [77 F]) 60 psi 120 psi 240 psi 250 psi 250 psi NA NA NA NA NA 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 10 psi 40 psi 60 psi 120 psi 240 psi 150 psi 150 psi 150 psi 150 psi 250 psi 0.35% FSS 0.35% FSS 0.25% FSS 0.25% FSS 0.25% FSS 10 psi 40 psi 60 psi 120 psi 240 psi 250 psi 250 psi 150 psi 150 psi 150 psi 150 psi 250 psi 250 psi 250 psi 0.35% FSS 0.35% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS Honeywell Sensing and Control 5 Table 8. Pressure Range Specifications for 60 mbar to 10 bar Pressure Range Order Code Pmin. Pmax. 001BA 1.6BA 2.5BA 004BA 006BA 010BA 0 bar 0 bar 0 bar 0 bar 0 bar 0 bar 1 bar 1.6 bar 2.5 bar 4 bar 6 bar 10 bar 060MD 100MD 160MD 250MD 400MD 600MD 001BD 1.6BD 2.5BD 004BD -60 mbar -100 mbar -160 mbar -250 mbar -400 mbar -600 mbar -1 bar -1.6 bar -2.5 bar -4 bar 60 mbar 100 mbar 160 mbar 250 mbar 400 mbar 600 mbar 1 bar 1.6 bar 2.5 bar 4 bar 060MG 100MG 160MG 250MG 400MG 600MG 001BG 1.6BG 2.5BG 004BG 006BG 010BG 0 mbar 0 mbar 0 mbar 0 mbar 0 mbar 0 mbar 0 bar 0 bar 0 bar 0 bar 0 bar 0 bar 60 mbar 100 mbar 160 mbar 250 mbar 400 mbar 600 mbar 1 bar 1.6 bar 2.5 bar 4 bar 6 bar 10 bar Over16 pressure Absolute 2 bar 4 bar 6 bar 8 bar 17 bar 17 bar Differential 500 mbar 500 mbar 500 mbar 1.4 bar 1.4 bar 2 bar 2 bar 4 bar 6 bar 8 bar Gage 500 mbar 500 mbar 500 mbar 1.4 bar 1.4 bar 2 bar 2 bar 4 bar 6 bar 8 bar 17 bar 17 bar Burst 17 Pressure Common Mode 18 Pressure Long-term Stability (1000 hr, 25 C [77 F]) 4 bar 8 bar 8 bar 16 bar 17 bar 17 bar NA NA NA NA NA NA 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 700 mbar 700 mbar 700 mbar 2.5 bar 2.5 bar 4 bar 4 bar 8 bar 8 bar 16 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 0.35% FSS 0.35% FSS 0.35% FSS 0.35% FSS 0.35% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 700 mbar 700 mbar 700 mbar 2.5 bar 2.5 bar 4 bar 4 bar 8 bar 8 bar 16 bar 17 bar 17 bar 3.5 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 16 bar 17 bar 17 bar 0.35% FSS 0.35% FSS 0.35% FSS 0.35% FSS 0.35% FSS 0.35% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS 0.25% FSS Notes: 16. Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. 17. Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. 18. Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified performance. Table 9. Pinout for SMT and DIP Packages Output Type 2 IC SPI Pin 1 GND GND Table 10. Pinout for SIP Package Output Type Pin 1 2 IC GND 6 www.honeywell.com/sensing Pin 2 Vsupply Vsupply Pin 3 SDA MISO Pin 4 SCL SCLK Pin 2 Vsupply Pin 5 NC SS Pin 6 NC NC Pin 3 SDA Pin 7 NC NC Pin 8 NC NC Pin 4 SCL Figure 4. DIP Pressure Port Dimensional Drawings (For reference only: mm [in]) DIP NN: No ports 8 7 6 DIP AN: Single axial barbed port 0,25 [0.010] 5,44 [0.214] 5 13,75 [0.541] 10,0 [0.39] 8 PORT 1 PORT 2 13,35 [0.525] 6,99 [0.275] 7 6 5 0,25 [0.010] 7,95 [0.313] 10,0 [0.39] 6,2 [0.24] 13,35 [0.525] 6,99 PORT 2 [0.275] 4,93 DIA. [0.194] PORT 1 1 2 3 1 4 2 9,24 [0.364] 10,85 [0.427] 2,54 TYP. [0.100] 3 4 9,24 [0.364] 11,21 [0.441] 2,54 TYP. [0.100] 8X 0,46 [0.018] 8X 0,46 [0.018] DIP LN: Single axial barbless port 5,80 [0.228] 8 7 6 DIP RN: Single radial barbed port 0,25 [0.010] 5 10,0 [0.39] 8 7 6 5 2,47 DIA. [0.097] PORT 2 13,35 [0.525] 6,99 [0.275] 0,25 [0.010] 5,80 [0.228] 10,0 [0.39] 4,2 [0.17] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 1 2 3 1,93 DIA. [0.076] 4 1 9,24 [0.364] 2,54 TYP. [0.100] 2 3 4 2,54 TYP. [0.100] 11,21 [0.441] 9,24 [0.364] 11,21 [0.441] 13,75 [0.541] 6,95 [0.274] 1,00 [0.039] 8X 0,46 [0.018] 8X 0,46 [0.018] DIP RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 5 PORT 1 PORT 1 PORT 2 ,25 [0.010] 6,16 [0.242] 13,35 [0.525] 6,99 PORT 2 [0.275] DIP DR: Dual radial barbed ports, opposite sides 15,76 [0.620] 10,0 [0.39] 2X 1,93 DIA. [0.076] 2 3 4 2,54 TYP. [0.100] 9,24 [0.364] 11,21 [0.441] 7 6 5 10,0 [0.39] 2X 1,93 DIA. [0.076] 6,99 PORT 2 [0.275] PORT 1 4,65 [0.183] 1 8 0,25 [0.010] 6,16 [0.242] 13,35 [0.525] PORT 1 PORT 2 1 2 3 9,24 [0.364] 4 2,54 TYP. [0.100] 3,78 [0.149] 11,21 [0.441] 3,78 [0.149] 8X 0,46 [0.018] 8X 0,46 [0.018] Honeywell Sensing and Control 7 Figure 5. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports 8 7 6 SMT AN: Single axial barbed port 10,0 [0.39] 5,44 [0.214] 5 13,75 [0.541] 8 6 5 10,0 [0.39] 7,95 [0.313] 13,4 [0.53] 6,99 PORT 2 [0.275] PORT 1 7 4,93 DIA. [0.194] PORT 2 13,4 [0.53] 6,99 [0.275] PORT 1 1 2 3 4 8X 0,46 [0.018] 4,80 [0.189] 6,41 [0.252] 2,54 TYP. [0.100] 1 5,80 [0.228] 7 6 3 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] SMT LN: Single axial barbless port 8 2 SMT RN: Single radial barbed port 10,0 [0.394] 5 8X 0,46 [0.018] 8 7 6 5,80 [0.228] 5 2,47 DIA. [0.097] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 10,0 [0.39] 4,2 [0.17] 13,3 [0.53] 6,99 PORT 2 [0.275] PORT 1 1,93 DIA. [0.076] PORT 1 1 2 3 1 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 8X 0,46 [0.018] 2 3 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 8X 0,46 [0.018] 13,75 [0.541] SMT RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 2X 1,93 DIA. [0.076] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 PORT 2 10,0 [0.39] 6,16 [0.242] 5 SMT DR: Dual radial barbed ports, opposite sides 2X 2,93 [0.115] 15,8 [0.62] 8 7 6 2X 1,93 DIA. [0.076] 4,6 [0.18] 1 2 3 4 2,54 TYP. [0.100] 13,4 [0.53] 6,99 [0.275] PORT 2 PORT 1 4,80 [0.189] 6,77 [0.266] 3,78 [0.149] 8 10,0 [0.39] 6,16 [0.242] 5 www.honeywell.com/sensing 8X 0,46 [0.018] 1 2 3 4 2,54 TYP. [0.100] 3,78 [0.149] 4,80 [0.189] 6,77 [0.266] 8X 0,46 [0.018] Figure 6. SIP Package Dimensional Drawings (For reference only: mm [in]) SIP NN: No ports SIP AA: Dual axial barbed ports, opposite sides 10,0 [0.39] 10,0 [0.39] 4,87 [0.192] 10,0 [0.39] PORT 1 22,06 [0.869] PORT 2 10,0 [0.39] PORT 2 PORT 1 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 15,2 [0.60] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2 3 2,54 TYP. [0.100] SIP AN: Single axial barbed port 10,0 [0.39] 0,25 [0.010] 10,0 [0.39] PORT 1 13,75 [0.541] 10,0 [0.39] PORT 2 2,47 DIA. [0.097] 15,2 [0.60] 15,2 [0.60] 2 3 4 4X 0,51 [0.020] PORT 2 PORT 1 4.93 DIA. [0.194] 1 2,54 TYP. [0.100] SIP LN: Single barbless port 13,75 [0.541] 10,0 [0.39] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2 3 4 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] 2,54 TYP. [0.100] SIP FF: Fastener mount, dual axial barbed ports, opposite sides 27,20 [1.071] 29,48 [1.161] 23,12 [0.910] 10,44 [0.411] 17,78 [0.700] PORT 2 PORT 1 2X 3.94 DIA. [0.155] 2X 4,78 DIA. [0.188] 20,16 [0.794] 1 0,25 [0.010] 4X 0,51 [.020] 2 3 4 2,54 TYP. [0.100] SIP FN: Fastener mount, single axial barbed port 29,48 [1.161] 16,38 [0.645] 23,12 [0.910] 17,78 [0.700] PORT 2 2X 3.94 DIA. [0.155] PORT 1 4.78 DIA. [0.188] 20,16 [0.794] 1 4X 0,51 [0.020] 0,25 [0.010] 2 3 4 2,54 TYP. [0.100] Honeywell Sensing and Control 9 Figure 6. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] 16,51 [0.650] 19,06 [0.750] PORT 2 PORT 1 2X 3,94 DIA. [0.155] 4.78 DIA. [0.188] 10,63 [0.418] 1 0,25 [0.010] 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 25,3 [0.996] 21,60 [0.850] 2X 4,80 DIA. [0.189] PORT 2 2X 3.50 DIA. [0.138] 22,87 [0.900] PORT 1 13 [0.52] 4 3 2 1 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] SIP RN: Single radial barbed port 10,0 [0.39] 5,80 [0.228] PORT 1 10,0 [0.39] PORT 2 1,92 DIA. [0.076] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 2,54 TYP. [0.100] SIP RR: Dual radial barbed ports, same side 10,0 [0.39] 6,16 [0.243] PORT 1 10,0 [0.39] PORT 2 2X 1,92 DIA. [0.076] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 10 www.honeywell.com/sensing 0,25 [0.010] 2,54 TYP. [0.100] Figure 6. SIP Package Dimensional Drawings (continued) SIP DR: Dual radial barbed ports, opposite side SIP HH: Fastener mount, dual radial barbed ports, same side 29,62 [1.166] 15,8 [0.62] 10,0 [0.39] 6,16 [0.243] 10,58 [0.416] 6,64 [0.261] 23,12 [0.910] PORT 2 10,0 [0.39] PORT 2 PORT 1 PORT 1 PORT 2 PORT 1 28,96 [1.140] 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 11,27 [0.444] 2,54 TYP. [0.100] 4X 0,51 [0.020] SIP HN: Fastener mount, single radial barbed port 23,12 [0.910] 0,25 [0.010] 2 3 4 2,54 TYP. [0.100] SIP MN: Manifold mount, outer diameter seal 7,97 [0.314] 4,78 DIA. [0.188] 1 5,36 [0.211] PORT 2 PORT 1 15,24 DIA. [0.600] PORT 1 28,96 [1.140] PORT 2 12,5 [0.49] 2X 3,94 DIA. [0.155] 11,27 [0.444] 1 4X 0,51 [0.020] 4X 0,51 [0.020] 2 3 4 0,25 [0.010] 0,25 [0.010] 1 2 3 4 2,54 TYP. [0.100] 2,54 TYP. [0.100] SIP SN: Manifold mount, inner diameter seal PORT 2 12,57 [0.495] 5,1 [0.20] PORT 1 13,11 [0.516] 15,6 [0.61] 1 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] Honeywell Sensing and Control 11 WARNING WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. DO NOT USE this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Asia Pacific Europe Latin America USA/Canada Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008213-2-EN IL50 GLO Printed in USA March 2011 (c) 2011 Honeywell International Inc. +65 6355-2828; +65 6445-3033 Fax +44 (0) 1698 481481; +44 (0) 1698 481676 Fax +1-305-805-8188; +1-305-883-8257 Fax +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax