Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: info@actcrystals.com
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without
notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
1 of 2
70 MHz Standard Filter for Base station application.
Part Number ACTF070020V/PK11
Horizontal: 1.2MHz/Div Horizontal: 1.2MHz/Div
Vertical: 10dB/Div Vertical: 5
0nsec/Div
Parameter Unit Minimum Typical Maximum
Centre Frequency MHz 69.90 70 70.10
Insertion Loss at F0 dB 22.8
1 dB Bandwidth MHz 1.7 1.80
3 dB Bandwidth MHz 2.0 2.06 2.1
40dB Bandwidth MHz 3.06 3.2
Passband Variation dB 0.9 1.0
Phase Linearity Deg
Group Delay Variation nsec 100 150
Absolute Delay usec 1.4
Ultimate Rejection dB 48 50 55
Substrate Material - LiTaO3
Ambient Temperature °C 25
Typical Performance
Typical Performance
Specifications
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: info@actcrystals.com
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without
notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
2 of 2
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1. Unless noted otherwise, all measurements are made with the filter installed in the specified test
fixture that is connected to a 50 Ω test system with VSWR 1.2:1. The test fixture L and C are
adjusted for minimum insertion loss at the filter centre frequency, fC
. Note that insertion loss,
bandwidth, and passband shape are dependent on the impedance matching component values and
quality.
2. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
3. The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
4. All equipment designs utilizing this product must be approved by the appropriate government
agency prior to manufacture or sale.
5. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for
applications, processes and circuits implemented within components or assemblies.
Package
Issue : 1 C1
Date : SEPT 04