Electrical
• Input voltage: 48VDC (European class I & II,
SELV and US NEC class 2. Both
with isolated output)
• Maximum input voltage: 60V (not recommended,
contact TE)
• Output current: 350mA
500mA
700mA
1050mA
• Output current tolerance: ±5%
• Forward voltage (Vf): 36VDC typical
• Forward voltage (Vf) range: Min: 25VDC
Max: 38VDC with 48VDC ±10% input
40VDC with 48VDC ±5% input
41VDC with 48VDC ±1% input
• Dimming
(dimming versions only): Source: 0-10V
Sink: EN60929 annex E compatible
dimmers
Potentiometer: At 10VDC the
external resistor value is 100kΩ.
At 1VDC the external resistor value
is 3.6kΩ
• Dimming controller type: European class I & II or US NEC
class 1&2. Both with basic isolation
• Dim to o: No
• Minimum dim level: 3% of maximum output current
• Flicker percentage: 0% (<2% at minimum dim level)
• Flicker index: 0
• Dimming curve: Linear (see Figure 1)
• Eciency: Up to 94% at maximum output
(see Figure 2)
• Reverse polarity protected: Yes
• Under voltage lock out
protection: Yes: 42VDC - 37VDC
• Input safety: Fused. Product fails safe
when 230V applied
• Noise: 30dB average
• Open/short circuit
protection: Yes
• Soft startup: 8ms (on/o), 90ms (dimmable)
• Soft shutdown: 30ms (on/o), 31ms (dimmable)
• Sink current manifested: Between 100ųA - 300ųA
• Hot pluggable: Yes
Figure 1: Dimming curve Figure 2: Eciency
Thermal
• Maximum operating
temperature: 125˚C (measured at
equivalent Tc point)
• Max Tc point temperature: 110°C (must not be exceeded)
• Thermal protection mode: Yes: Output reduces to 20%
regardless of dimming level
• Over temperature reset
(dimmable versions): After power cycle
• Over temperature reset
(on/o versions): After cooling down
• Thermal interface material: Recommended: Use Laird PLC
AS004444-25
• Storage temperature: -20˚C to 60˚C
Optical
• Optics: Compatible with TE’s Z50
optic clip type 1 and type 2
(part numbers: 2213194-1 and
2213349-1)
• Allowable beam angle: 135˚
Other
• Diagnostic information: Yes: Dimmable version will
collect limited diagnostics.
Including, firmware version,
current output, initial temperature,
over temperature event count,
time to event and dimming level.
This information is only accessible
by TE
• EMC: IEC 61547, FCC title 47 (part 15
subpart B), CISPR15, EN55015
• Vibration: EIA 364-28, IEC 60512-6-4,
IEC 60512-6-5
• Mechanical shock: EIA 364-27 (test condition H),
IEC 60512-6-3
• Thermal shock: EIA-364-32 (test condition
VIII), IEC 60512-11-4
• Damp heat cycling: EIA-364-31 (method III),
IEC 60512-11-3, IEC 60512-11-12
• Contact normal force: 500 hours at 125 °C
INTELLIGENT BUILDINGS /// LUMAWISE DRIVE LED HOLDER TYPE Z50
LUMAWISE DRIVE LED HOLDER TYPE Z50