Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 39126 Hook-up/Lead - PPO Hook-up Wire 600V, 105C AWM Style 11029 For more Information please call 1-800-Belden1 General Description: 26 AWG stranded (7x34) tinned copper conductor, PPO insulation. Rated 105C, 600V. Rated 2500V peak for electronic circuits, and internal wiring of electronic and electrical equipment Usage (Overall) Suitable Applications: Electrical panel builders, Electrical/electronic manufacturers, Appliance manufacturers, Furniture, Computer manufacturers, Automotive companies and their sub-suppliers Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 1 26 7x34 TC - Tinned Copper Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Wall Thickness (in.) PPO - Polyphenylene Oxide 0.012 Overall Insulation Overall Cable Overall Nominal Diameter: 0.043 in. Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +105C Dry Bulk Cable Weight: 1.400 lbs/1000 ft. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs UL Rating: 600 V, 105C UL Type: AWM 11028 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2011 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: VW-1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 37.300 Max. Operating Voltage - UL: Voltage Page 1 of 2 01-09-2015 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 39126 Hook-up/Lead - PPO Hook-up Wire 600V, 105C AWM Style 11029 600 Vac Max. Recommended Current: Description Current Single conductor in free air @ 30C ambient 6.5 amps Notes (Overall) Notes: Halogen-free. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 39126 001100 100 FT 0.200 LB BROWN C #26 STR PPO BRN 39126 0011000 1,000 FT 2.000 LB BROWN C #26 STR PPO BRN 39126 0015000 5,000 FT 10.000 LB BROWN CZ #26 STR PPO BRN 39126 002100 100 FT 0.200 LB RED C #26 STR PPO RED 39126 0021000 1,000 FT 2.000 LB RED C #26 STR PPO RED 39126 0025000 5,000 FT 10.000 LB RED CZ #26 STR PPO RED 39126 003100 100 FT 0.200 LB ORANGE C #26 STR PPO ORG 39126 0031000 1,000 FT 2.000 LB ORANGE C #26 STR PPO ORG 39126 0035000 5,000 FT 10.000 LB BLUE, LIGHT CZ #26 STR PPO ORG 39126 004100 100 FT 0.200 LB YELLOW C #26 STR PPO YEL 39126 0041000 1,000 FT 2.000 LB YELLOW C #26 STR PPO YEL 39126 0045000 5,000 FT 10.000 LB YELLOW CZ #26 STR PPO YEL 39126 005100 100 FT 0.200 LB GREEN, DARK C #26 STR PPO DGRN 39126 0051000 1,000 FT 2.000 LB GREEN, DARK C #26 STR PPO DGRN 39126 0055000 5,000 FT 10.000 LB GREEN, DARK CZ #26 STR PPO DGRN 39126 007100 100 FT 0.200 LB VIOLET C #26 STR PPO VIO 39126 0071000 1,000 FT 2.000 LB VIOLET C #26 STR PPO VIO 39126 0075000 5,000 FT 10.000 LB VIOLET CZ #26 STR PPO VIO 39126 008100 100 FT 0.200 LB GRAY C #26 STR PPO GRY 39126 0081000 1,000 FT 2.000 LB GRAY C #26 STR PPO GRY 39126 0085000 5,000 FT 10.000 LB GRAY CZ #26 STR PPO GRY 39126 009100 100 FT 0.200 LB WHITE C #26 STR PPO WHT 39126 0091000 1,000 FT 2.000 LB WHITE C #26 STR PPO WHT 39126 0095000 5,000 FT 10.000 LB WHITE CZ #26 STR PPO WHT 39126 010100 100 FT 0.200 LB BLACK C #26 STR PPO BLK 39126 0101000 1,000 FT 2.000 LB BLACK C #26 STR PPO BLK 39126 0105000 5,000 FT 10.000 LB BLACK CZ #26 STR PPO BLK 39126 013100 100 FT 0.200 LB BLUE, DARK C #26 STR PPO DBLU 39126 0131000 1,000 FT 2.000 LB BLUE, DARK C #26 STR PPO DBLU 39126 0135000 5,000 FT 10.000 LB BLUE, DARK CZ #26 STR PPO DBLU Notes: C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Revision Number: 0 Revision Date: 07-13-2012 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 2 of 2 01-09-2015