Gas Discharge Tubes GTCX26-XXXM-R05 Series Raychem Circuit Protection 6mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that typically result from lightning strikes and equipment switching operations. Raychem Circuit Protection GDTs offer a high level of surge protection, low capacitance and a broad array of breakover voltage levels, making them suitable for applications such as MDF (Main Distribution Frame) modules, high data-rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. Raychem Circuit Protection GDTs, can help equipment meet the most stringent regulatory standards. Benefits: Features: * Compact, small form factor suitable for efficient assembly * 2Pole, 6mm devices * Broad voltage range from 75V-600V * Helps provide overvoltage fault protection against high energy surges * Various form factors: surface mount, axial leads, no leads * Suitable for high-frequency applications * Low capacitance and insertion loss * UL 497B recognized * RoHS compliant * Devices tested per ITU K.12 recommendations * Non-radioactive materials Applications: * Telecommunications * Industrial and consumer electronics, such as - MDF modules, xDSL equipment, RF system - Surge protectors protection, antenna, base station - Alarm system Gas Discharge Tubes (c) 2008 Tyco Electronics Corporation. All rights reserved. 1 Document: SCD 27329 Status: Released Rev: A Date: MARCH 10, 2007 Gas Discharge Tubes GTCX26-XXXM-R05 Series Device Voltage Ratings and Part Marking Part Number DC Holdover Voltage Impulse Sparkover DC Sparkover On-State Voltage Nominal (@ 1A) (V) @100V/s 20% Tolerance (V) @100 V/s (V) @1000 V/s (V) GTCX26-750M-R05 75 450 550 <52 20 GTCX26-900M-R05 90 450 550 <52 20 GTCX26-141M-R05 140 500 600 <80 20 GTCX26-151M-R05 150 500 600 <80 20 GTCX26-201M-R05 200 600 700 <135 20 GTCX26-231M-R05 230 600 700 <135 20 GTCX26-251M-R05 250 600 700 <135 20 GTCX26-261M-R05 260 700 800 <135 20 GTCX26-301M-R05 300 800 900 <150 20 GTCX26-351M-R05 350 900 1000 <150 20 GTCX26-401M-R05 400 900 1000 <150 20 GTCX26-421M-R05 420 900 1000 <150 20 GTCX26-471M-R05 470 1050 1150 <150 20 GTCX26-501M-R05 500 1100 1200 <150 20 GTCX26-551M-R05 550 1300 1400 <150 20 GTCX26-601M-R05 600 1300 1400 <150 20 Per ITU K.12 (<150ms) (V) Device Surge Rating, Capacitance, Insulation Resistance, UL Part Number Impulse Life AC Discharge Current (1sec duration; 10 hits) Capacitance Insulation Resistance UL Rating 8x20s 10 hits 10x1000s 300 hits @50 Hz @1Mhz @100V* UL497B #E179610 5kA 100A 5Arms <1pF 10,000 (M) All Devices Impulse Discharge Current GTCX26-XXXM-R05 Devices <=90V measured @ 50V Devices >=500V measured @ 250V Gas Discharge Tubes (c) 2008 Tyco Electronics Corporation. All rights reserved. 2 Document: SCD 27329 Status: Released Rev: A Date: MARCH 10, 2007 Gas Discharge Tubes GTCX26-XXXM-R05 Series Product Dimensions DIMENSIONS = MILLIMETERS [INCHES] Surface-mount (GTCS26-XXXM-R05) No Leads (GTCN26-XXXM-R05) Axial Leads (GTCA26-XXXM-R05) Pad Layout - Surface- mount Devices (GTCS26-XXXM-R05) mm: in*: X NOM 7.0 (0.276) Y NOM 3.7 (0.146) Z NOM 1.3 (0.051) Gas Discharge Tubes (c) 2008 Tyco Electronics Corporation. All rights reserved. 3 Document: SCD 27329 Status: Released Rev: A Date: MARCH 10, 2007 Gas Discharge Tubes GTCX26-XXXM-R05 Series General Characteristics No Radioactive Material Storage Temperature: -40C to +90C Operating Temperature: -40C to +90C Body: Nickel Plated Leads: Surface-mount, Axial Devices: Tin Plated Devices with No Leads: Nickel Plated Soldering Note: Devices with no leads are non-solderable; meant for insertion into magazine clips Packaging Information Part Description Tray / Reel Standard Package No Leads: GTCN26-XXXM-R05 Axial Leads: GTCA26-XXXM-R05 Surface-mount: GTCS26-XXXM-R05 Surface-mount (T&R): GTCS26-XXXM-R05-2 100pcs 100pcs 100pcs 750pcs 2,000pcs 1,000pcs 2,000pcs 6000pcs Part Numbering System Example Part Number: GTCX26-351M-R05 GT = C= X= 2= 6= 351 = M= R= 05 = Gas Tube Ceramic Lead Configuration: N= No leads; A= Axial Leads; S= Surface-mount 2 Electrode device 6mm Diameter DC Spark Over Voltage of 350V (at 100V/s) Tolerance of 20% on DC Spark Over Voltage Product Family Designator Surge rating: 8x20s 5kA 10 times Gas Discharge Tubes (c) 2008 Tyco Electronics Corporation. All rights reserved. 4 Document: SCD 27329 Status: Released Rev: A Date: MARCH 10, 2007 Gas Discharge Tubes GTCX26-XXXM-R05 Series Part Marking Reference Example Part Marking: = 35 = R05 = GN = 35 R05 GN Manufacture Mark Voltage Designator (35 = 350V) Product Family Designator + Surge Current 5kA (8x20s 10 hits) Year and Week of Manufacture 308 Constitution Drive, MS R21/2A Menlo Park, CA USA 94025-1164 Tel (800) 227-7040 (650) 361-6900 Fax (650) 361-2508 www.circuitprotection.com www.circuitprotection.com.hk (Chinese) www.circuitprotection.jp (Japanese) Raychem, TE Logo and Tyco Electronics are trademarks. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Tyco Electronics reserves the right to change or update, without notice, any information contained in this publication; to change, without notice, the design, construction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all information previously supplied. Without expressed or written consent by an officer of Tyco Electronics, Tyco Electronics does not authorize the use of any of its products as components in nuclear facility applications, aerospace, or in critical life support devices or systems. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics' only obligations are those in the Tyco Electronics Standard Terms and Conditions of Sale and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products. Gas Discharge Tubes (c) 2008 Tyco Electronics Corporation. All rights reserved. 5 Document: SCD 27329 Status: Released Rev: A Date: MARCH 10, 2007