Circuit Protection Circuit Break ers CB4201-10 CB4202-10 Single Pole Double Pole Thermal Magnetic Type Ordering Data Type: Single Pole - CB4201-10 Internal Resistance per Pole (ohms) Current Ratings (amps) Part No.* TS 32 Part No.* TS 32 0.1 9104173200 9104173500 0.1 9120353200 9120353500 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 9104183200 9129813200 9124093200 9101003200 9124113200 9129563200 9101103200 9101203200 9104183500 9129813500 9124093500 9101003500 9124113500 9129563500 9101103500 9101203500 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1.0 9124243200 9124263200 9124273200 9129583200 9124283200 9124293200 9129593200 9129613200 9124243500 9124263500 9124273500 9129583500 9124283500 9124293500 9129593500 9129613500 1.22 0.61 0.55 0.38 0.24 0.19 1.2 1.5 1.8 2.0 2.5 3.0 9101303200 9101403200 9124143200 9101503200 9101603200 9101703200 9101303500 9101403500 9124143500 9101503500 9101603500 9101703500 1.2 1.5 1.8 2.0 2.5 3.0 9129623200 9129633200 9124333200 9129643200 9129653200 9129663200 9129623500 9129633500 9124333500 9129643500 9129653500 9129663500 0.16 0.09 0.09 0.061 3.5 4.0 4.5 5.0 9124163200 9104353200 9124163500 9104353500 9124173500 9101803500 3.5 4.0 4.5 5.0 9124343200 9129713200 9124343500 9129713500 9129673200 9129673500 0.07 0.041 0.04 0.034 5.5 6.0 6.5 7.0 9107833500 9103813500 9120043500 9104153500 5.5 6.0 6.5 7.0 9124363200 9124373200 9124383200 9124393200 0.02 0.02 <0.02 <0.02 8.0 9.0 10.0 11.0 9103003200 9104613200 9101903200 9103003500 9104613500 9101903500 9124183500 8.0 9.0 10.0 11.0 9104673200 9124423200 9129683200 9124433200 9104673500 9124423500 9129683500 <0.02 <0.02 <0.02 <0.02 12.0 13.0 14.0 15.0 9107843200 12.0 13.0 14.0 15.0 9124443200 9124453200 9124463200 9129693200 9124443500 9107853200 9102003200 9107843500 9124193500 9107853500 9102003500 9124463500 9129693500 <0.02 16.0 9124213200 9124213500 16.0 9124473200 9124473500 9101803200 9103813200 9104153200 * Ordering Options - Example To order CB4201-10 Single Pole Circuit Breaker, Part No. 9101203501 4200 Series M1+ M1+ 0.05 to 7.5 A 8 to 16 A * * * * Current Rating of 1.0 amps Internal Resistance per Pole of 1.67 ohms For TS 35 Without Trip Button 10,000 10,000 -30C +23C +55C -30C +23C +55C 1,000 100 100 Trip time in seconds 1,000 10 1 "00" - Standard Circuit Breaker "01" - Without Trip Button 1 0.1 0.01 0.01 "32" - TS 32 DIN-Rail Mountable "35" - TS 35 DIN-Rail Mountable Base Part No. (Determines 1 or 2 pole unit) 0.001 0.001 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 9 1 0 1 2 0 3 5 0 1 10 0.1 0.8 1 Part No.* TS 35 40.00 19.30 10.40 7.10 4.30 3.58 2.50 1.67 Thermal Magnetic Type Typical time/current characteristics at 23C Trip time in seconds Current Ratings (amps) 131.00 Circuit Break er - Trip Curv es 126 Type: Double Pole - CB4202-10 Part No.* TS 35 0.8 1 2 3 4 6 8 10 20 30 ... times rated current 50 70 100 T o manually trip breaker, a plastic or wooden dowel (0.12 inch diameter) will be needed. 9124373500 9124393500 CB4201-10 Single Pole Internal Wiring Diagram Dimensions in mm Internal Wiring Diagram CB4202-10 Double Pole Dimensions in mm Technical Data Rated voltage & current UL CSA VDE Creepage resistance Dielectric strength Insulation resistance Interrupting capacity AC 250 V, DC 80 V, 50/60 Hz AC 250 V, DC 65 V, 50/60 Hz PTI 600 to IEC 112 4,000 VAC; IEC 664 & 664 A 0.05...16 A 0.05...16 A 2.5...16 A Rated current 0.05...4.5 A Interrupting capacity; 4201-10 (UL 1077/EN 60934 PC1) 400 A Rated voltage AC 250 V 5...8 A AC 250 V 9...15 A AC 125 V 0.05...15 A DC 65 V 5,000 operations Nm (lb. in.) Temperature range Corrosion Humidity Weight Wire size (UL) maximum capacity 200 A 1000 A 1000 A 200 A 25 g (11 ms) to IEC 68-2-27, Test Ea 0.8 (7.1) 5 g (57 to 500 Hz / 0.38 mm, 10 to 57 Hz) to IEC 68-2-6, Test Fc -30C...+55C (-22F...+131F) Type Jumpers Daisy Chain 50* Straight CQB** Angled CQB** Adaptor foot Marking Tags Special print only Consecutive horizontal Note: Part numbers are shown for a single card of pre-printed tags numbered 1-50. Consecutive vertical Part No. BDC 50 CQB 2 CQB 3 CQB 4 CQB 10 CQB 2 CQB 3 9970290000 9970560000 9970570000 9970580000 9970590000 9970600000 9970610000 CQB 4 CQB 10 AF/TS 32 9970620000 9970630000 9102100000 WS 8/5 MC DEK 5/5 DEK 5/5 1640750000*** 0473460001 0473560001 Note: Resistive and inductive loads (0.05 - 16 A) *BDC will accommodate 20 A per pin, 20 A total **CQB will accommodate 18 A per pin, 18 A total; dedicated to 4201 Series ***Please specify horiz ontal or vertical print when ordering. Standard quantity = 144 tags per card. 127 RAIL MOUNTED TERMINAL BLOCKS: SAK-SERIES 96 hours at 5% salt spray, to IEC 68-2-11, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole # 20...8 AWG solid # 20...10 AWG standard Accessories 1 2 3 4 5 6 Current Ratings 0.05...16 A > 100 M1 (DC 500 V) 4201-10 maximum capacity 0.05...0.8 A self-limiting 1...2 A 200 A (VDE 0660, Part 101, P-2) Typical life at 2 x rated current Shock Torque Vibration Voltage Ratings AC 250 V, DC 80 V, 50/60 Hz