D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter PRODUCT OVERVIEW The D1U54-D-650-12-HBxC products are very high efficiency DC input 650 watt front end supplies provided with a 12V main and a 12V Standby output. An active (analogue) current share characteristic is provided to allow units to be operated in parallel. The power supply may be hot plugged; recovers from overtemperature faults, and has status LEDs on the front panel in addition to hardware signal logic and PMBusTM status signals. The low profile 1U package and 21.4W/cubic inch power density make them ideal for delivering reliable, efficient power to networking equipment, workstations, storage systems and other 12V distributed power architectures. ORDERING GUIDE Part Number FEATURES 650W output power 93% efficiency at 50% load 12V main output 12V standby output 1U height: 2.15" x 9.00" x 1.57" 54.5mm x 228.6mm x 40mm 21.4 Watts per cubic inch density N+1 redundancy capable, including hot plugging Active (analogue) current sharing on 12V main Murata Internal Power Output Part Number -44 to -72Vdc D1U54-D-650-12-HB3C M1879 D1U54-D-650-12-HB4C M1878 INPUT CHARACTERISTICS Parameter Input Source Voltage Operating Range Turn-on Input Voltage Turn-off Input Voltage Input current at Vin = -53Vdc Inrush Current Main Output Standby Output 12Vdc 12Vdc Airflow Front to Back 650W Conditions Min. -44 -42.5 -37.5 Ramp up Ramp down 650W Cold start (25C) between 0 to 200ms Back to front Nom. -53 -43 -38 13.6 Max. -72 -43.5 -39.5 Vdc Adc 25 20% load Efficiency (-53Vdc) excluding fan load 50% load 100% load Units Vdc 90 93 92 Apk % output; ORING FET Overvoltage, Overcurrent, Overtemperature protection Internal cooling fan (variable speed) PMBusTM/I2C interface with status indicators RoHS compliant Two Year Warranty OUTPUT VOLTAGE CHARACTERISTICS Nominal Output Parameter Voltage Output Set Point Accuracy Line and Load Regulation 12V www.murataps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Available now at: www.murata-ps.com/en/3d/acdc.html Ripple Voltage & Noise1, 2 Output Current Range Load Capacitance Output Set Point Accuracy Line and Load Regulation 12VSB 1 2 Ripple Voltage & Noise1 Output Current Conditions 50% load; Tamb =25C Setpoint; temperature; line and load 20MHz Bandwidth 50% load; Tamb = 25C Setpoint; temperature; line and load 20MHz Bandwidth Min. Typ. Max. 11.96 -1.0% 12.00 12.04 +1.0 % 120 54.2 4000 12.04 12.3 0 500 11.96 11.7 0 12.00 120 2 Units Vdc % mV p-p A F Vdc mV p-p A Ripple and noise is measured with a parallel combination 0.1F of ceramic and 10F of tantalum capacitance on each measurement node. Measurements assume the use of the minimum load capacitance as specified for the main 12V output and a minimum load of 5%. Below 5% loading the overall voltage deviation shall be within 2.5%. CB For full details go to www.murata-ps.com/rohs Test Certificate and Test Report www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 1 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter OUTPUT CHARACTERISTICS Parameter Conditions Startup Time Min. Typ. DC ramp up Main 12V, 50% load step, 1A/s di/dt 12VSB, 50% load step, 1A/s di/dt Transient Response Current sharing accuracy >10% load; *of maximum output current capability Hot Swap Transients Holdup Time (Total Effective Hold Up - See Timing Waveforms) All outputs remain in regulation Full DC Input Source Range; 100% load ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (without derating at 40C) Shock 2 Conditions Min. -40 -5 5 5 Noncondensing; +45C Typ. Max. 3 Units s 5 500 % s 5* % 54 % ms Max. 70 50 90 95 3000 Units 30G non-operating Sine sweep; 5-200Hz, 2G; random vibration, 5-500Hz, 1.11G Per Telcordia SR-332 Issue 3 M1C3 @40C 619K CAN/CSA C22.2 No 60950-1-07, Am.1:2011 UL 60950-1-2011, 2nd Ed. IEC60950-1:2005 (2nd Ed.) w A1:2009 EN 60950-1:2006+A11+A1+A12+A2 CCC GB4943.1-2011; GB9254-1-2008; GB17625, 1-2012 Power Supply has an internal 25A/100Vdc fast blow fuse in the DC input negative line. 1.74 lbs (0.789 kg) Operational Vibration MTBF(Target) Safety Approvals Input Fuse Weight C % m hrs AIRFLOW; PRESSURE VS. FLOW (PQ) CURVES D1U54-D-650-12-HB3C & D1U54-D-650-12-HB4C D1U54-D-650-12-HBxC P & Q CURVE 250 Back Pressure (Pa) 200 150 Airflow Front to Back Airflow Back to Front 100 50 0 0 2 4 PSU airflow (CFM) 6 8 Notes: 1. The above curves represent performance based upon a the use of a 20mm thickness fan. 2. Curves recorded at room ambient (circa 25C). 3. Curves generated with intermal fan running at 100% duty cycle www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 2 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter PROTECTION CHARACTERISTICS Output 12V Parameter Conditions Overtemperature Overvoltage Autorestart with 4C hysteresis for recovery (warning issued at 70C) Latching 13 The output shall shutdown when an overcurrent condition is detected. It will auto restart after 1sec; however if the overcurrent condition is redetected the output will once again shutdown. The output will once again re-start, however if the overcurrent condition persists it will latch of after the fifth 60 unsuccessful attempt. To reset the latch it will be necessary to toggle the PS_ON_L signal (B4) or recycle the incoming DC source. Latching 13.0 Overcurrent (Target) Overvoltage 12VSB Overcurrent Min. The output shall shutdown when an overcurrent is detected. It will auto restart after 2sec; however if the overcurrent is re-detected the output will once again shutdown. This cycle will occur indefinitely while the overcurrent condition persists. ISOLATION CHARACTERISTICS Parameter Conditions Input to Output Input to Chassis Output to Chassis Insulation Safety Rating Isolation EMISSIONS AND IMMUNITY Conducted Emissions ESD Immunity Radiated Field Immunity Electrical Fast Transients/Burst Immunity FCC 47 CFR Part 15/CISPR 22/EN55022 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 Surge Immunity IEC/EN 61000-4-5 RF Conducted Immunity Magnetic Field Immunity Voltage Dips, Interruptions IEC/EN 61000-4-6 IEC/EN 61000-4-8 ---- Min. 1000 1000 500 Typ. Typ. Max. Units 75 C 14.5 C 70 A 14.5 V 2.2 2.8 A Max. Units Vdc Vdc Vdc Class A with 6dB margin Level 4 criteria A Level 3 criteria B Level 3 criteria B 1kV common mode and differential mode, unit passes criteria A (normal performance)* Level 3 criteria A 3 A/m criteria B -53Vin, 80% load, Dip 100% Duration 4ms,Criteria (A) * Impedance is 2 ohms for differential and common mode. STATUS INDICATORS LED NAME Input Input LED MODE OK OV/UV WARNING LED STATE/OPERATION Solid Green Blinking Green Input OFF OR FAULT Off Output POWER GOOD Solid Green Output Output Output STANDBY WARNING FAULT Blinking Green Blinking Amber Solid Amber DESCRIPTION Input voltage operating within normal specified range Input voltage operating in: 1) overvoltage warning, or 2) undervoltage warning range Input voltage operating: 1) above overvoltage range, or 2) below undervoltage range, or 3) not present Main output and standby output enabled with no power supply warning or fault detected Standby output enabled with no power supply warning or fault detected Power supply warning detected as per PMBus STATUS_X reporting bytes Power supply fault detected as per PMBus STATUS_X reporting bytes LED fault/warning operation follows PMBus fault/warning reporting status flags and will thus also be 'sticky' (i.e. even if actual fault/warning is cleared, LED will still be in FAULT or WARNING mode until PMBus status flags are cleared with the CLEAR_FAULTS command www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 3 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter STATUS AND CONTROL SIGNALS Signal Name I/O INPUT_OK (DC Source) Output PW_OK (Output OK) Output SMB_ALERT (FAULT/WARNING) Output Description Interface Details The signal output is driven high when the input source is available and within acceptable limits. The output is driven low to indicate loss of input power. There is a minimum of 5ms pre-warning time before signal changes to a high impedance state or is driven low to indicate loss of 12V. The power supply must ensure that this interface signal provides accurate status when DC power is lost. The signal is asserted, driven high, by the power supply to indicate that all outputs are valid. If any of the outputs fail then this output will be hi-Z or driven low. The output is driven low to indicate that the Main output is outside of lower limit of regulation. Pulled up internally via 10K to 3.3Vdc. A logic high >2.0Vdc; A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). The signal output is driven low to indicate that the power supply has detected a warning or fault and is intended to alert the system. This output must be driven high when the power is operating correctly (within specified limits). The signal will revert to a high level when the warning/fault stimulus (that caused the alert) is removed. PRESENT_L Output The signal is used to detect the presence (installed) of a PSU by the host system. The signal is (Power Supply Absent) connected to PSU logic SGND within the power module. PS_ON Input This signal is pulled up internally to the internal housekeeping supply (within the power supply). (Power Supply The power supply main 12Vdc output will be enabled when this signal is pulled low to Enable/Disable +VSB_Return. In the low state the signal input shall not source more than 1mA of current. The 12Vdc output will be disabled when the input is driven higher than 2.4V, or open circuited. Cycling this signal shall clear latched fault conditions. PS_KILL Input This signal is used during hot swap to disable the main output during hot swap extraction. The input is pulled up internally to the internal housekeeping supply (within the power supply). The signal is provided on a short (lagging pin) and should be connected to +VSB_Return. ADDR (Address Select) Input An analogue input that is used to set the address of the internal slave devices (EEPROM and microprocessor) used for digital communications. Connection of a suitable resistor to +VSB_Return, in conjunction with an internal resistor divider chain, will configure the required address (see ADDR Address Selection table). SCL (Serial Clock) Both A serial clock line compatible with PMBusTM Power Systems Management Protocol Part 1 - General Requirements Rev 1.1. No additional internal capacitance is added that would affect the speed of the bus. The signal is provided with a series isolator device to disconnect the internal power supply bus in the event that the power module is completely unpowered, SDA (Serial Data) Both A serial data line compatible with PMBusTM Power Systems Management Protocol Part 1 - General Requirements Rev 1.1. The signal is provided with a series isolator device to disconnect the internal power supply bus in the event that the power module is completely unpowered, V1_SENSE Input Remote sense connections intended to be connected at and sense the voltage at the point of load. V1SENSE_RTN The voltage sense will interact with the internal module regulation loop to compensate for voltage drops due to connection resistance between the output connector and the load. If remote sense compensation is not required then the voltage shall be configured for local sense by: 1. V1_SENSE directly connected to power blades 6 to 10 (inclusive) 2. V1_SENSE_RTN directly connected to power blades 1 to 5 (inclusive) ISHARE BiThe current sharing signal is connected between sharing units (forming an ISHARE bus). It is an Directional input and/or an output (bi-directional analogue bus) as the voltage on the line controls the Analogue current share between sharing units. A power supply will respond to a change in this voltage Bus but a power supply can also change the voltage depending on the load drawn from it. On a single unit the voltage on the pin (and the common ISHARE bus would read 8VDC at 100% load (module capability). For two identical units sharing the same 100% load this would read 4VDC for perfect current sharing (i.e. 50% module load capability per unit). Pulled up internally via 10K to 3.3Vdc. A logic high >2.0Vdc; A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). Pulled up internally via 10K to 3.3Vdc. A logic high >2.0Vdc;A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). Passive connection to +VSB_Return. A logic low <0.8Vdc Pulled up internally via 10K to 3.3Vdc. A logic high >2.0Vdc A logic low <0.8Vdc Input is via CMOS Schmitt trigger buffer. Pulled up internally via 10K to 3.3Vdc. A logic high >2.0Vdc; A logic low <0.8Vdc Input is via CMOS Schmitt trigger buffer. DC voltage between the limits of 0 and +3.3Vdc. VIL is 0.8V maximum VOL is 0.4V maximum when sinking 3mA VIH is 2.1V minimum VIL is 0.8V maximum VOL is 0.4V maximum when sinking 3mA VIH is 2.1V minimum Compensation for up to 0.12Vdc total connection drop (output and return connections). Analogue voltage: +8V maximum; 10K to +12V_RTN www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 4 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter TIMING SPECIFICATIONS Turn-On Delay & Output Rise Time: Power-on-delay, Risetime, and signaling V1 PS_ON delay DC input DC input Vsb Vsb Vsb Risetime V1 Vsb Power-on-delay V1 V1 Risetime V1 Power-on-delay V1 PS_ON delay PS_ON PS_ON Input_OK delay Input_OK Input_OK PWOK delay PWOK PWOK 1. The turn-on delay after application of AC input within the operating range shall as defined in the following tables. 2. The output rise times shall be measured from 10% of the nominal output to the lower limit of the regulation band as defined in the following tables. Time Vsb Rise time V1 Rise time Vsb Power-on-delay V1 Power-on-delay V1 PS_ON delay V1 PWOK delay DCOK (Input) detect Min 70ms 120ms 300ms 500ms 100ms 300ms 500ms Max 170ms 220ms 700ms 1500ms 300ms 450ms 1000ms TIMING SPECIFICATIONS Turn-Off (Shutdown by PS_ON) Turn-Off Timing V1 Fall time V1 PS_OFF delay PW_OK delay off Vsb V1 V1 PS_OFF delay Min 0ms 2.0ms Max 6ms Notes Must be monotonic V1 Falltime PS_ O N I n pu t_ O K PW_OK delayoff PWO K 1. Note this characteristic is applicable for the main 12Vdc output shutdown from PS_ON pulled high. www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 5 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter TIMING SPECIFICATIONS Power Removal Holdup Power Removal Timing Vsb holdup V1 holdup (Total Effective) DC (Input) fail detect PWOK delay off PWOK Hold Up Min 20ms 4ms 400s 2.0ms 2.0ms Max 50ms 1000s 4.0ms Notes +VSB Full Load 100% load 100% load OUTPUT CONNECTOR & SIGNAL INTERFACE; FCI PN 10122460-005LF NB: Reference to "3" in Column 5, refers to the shortest level signal pin; the "shortest" pins are the "last to make, first to break" in the mating sequence. www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 6 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter OUTPUT CONNECTOR PIN ASSIGNMENTS - D1U54P-W-650-12-HBxC (Power Supply) FCI PN 10122460-005LF Pin Signal Name Comments 6, 7, 8, 9, 10 V1 (+12VOUT) +12V Main Output 1, 2, 3, 4, 5 +12V RTN/PGND +12V Main Output Return A1 +VSB Standby Output B1 +VSB Standby Output C1 +VSB Standby Output D1 +VSB Standby Output E1 +VSB Standby Output A2 +VSB_Return Standby Output Return B2 +VSB_Return Standby Output Return C2 Unused No End User Connection D2 Unused No End User Connection E2 Unused No End User Connection A3 APS I2C Address Protocol Selection; (Select address by appropriate pull down resistor - See table below) B3 Unused No End User Connection C3 SDA I2C Serial Data Line D3 V1_SENSE_R -VE Remote Sense Return E3 V1_SENSE +VE Remote Sense A4 SCL I2C Serial Clock Line B4 PS_ON_L Remote On/Off (Enable/Disable) C4 SMB_ALERT Alert signal to host system D4 Unused No End User Connection E4 INPUT_OK DC Input Source Present & "OK" A5 PS_KILL Power Supply "kill"; short pin B5 ISHARE Active Current Share Bus C5 PW_OK Power "OK"; short pin D5 Unused No End User Connection E5 PRESENT_L Power Module Present; short pin WIRIN MATING CONNECTOR Part Number Description TE Connectivity 2-1926739-5 Right Angle FCI 10108888-R10253SLF Right Angle APS ADDRESS SELECTION APS pin (A3) resistor to GND (K-ohm)* 0.82 2.7 5.6 8.2 15 27 56 180 Power Supply Main Controller (Serial Communications Slave Address) 0xB0 0xB2 0xB4 0xB6 0xB8 0xBA 0xBC 0xBE Power Supply External EEPROM (Serial Communications Slave Address) 0xA0 0xA2 0xA4 0xA6 0xA8 0xAA 0xAC 0xAE * The resistor shall be +/-5% tolerance www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 7 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter WIRING DIAGRAM FOR OUTPUT WIRING DIAGRAM FOR OUTPUT CURRENT SHARE NOTES 1. Main Output: Current sharing is achieved using the active (analogue) current share method. 2. Current sharing can be achieved with or without the remote (V_SENSE and V_SENSE_R) connected to the common load. 3. +VSB Outputs can be tied together for redundancy but total combined output power must not exceed the rated standby power. The +VSB output has an internal ORING MOSFET for additional redundancy/internal short protection. 4. The current sharing pin B5 is connected between sharing units (forming an ISHARE bus). It is an input and/or an output (bi-directional analogue bus) as the voltage on the line controls the current share between sharing units. A power supply will respond to a change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit the voltage on the pin (and the common ISHARE bus would read 8VDC at 100% (power module load capability). For two units sharing the same 100% load this would read 4VDC for perfect current sharing (i.e. 50% power module load capability per unit). The load for both the main 12V and the VSB rails at initial startup shall not be allowed to exceed the capability of a single unit. The load can be increased after a delay of 3sec (minimum), to allow all sharing units to achieve steady state regulation. www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 8 of 9 D1U54-D-650-12-HBxC Series 54mm 1U Front End DC-DC Power Supply Converter MECHANICAL DIMENSIONS 1. 2. 3. 4. DC input connector: Dinkle Terminal Block, Dinkle Enterprise: Part No. DT-7C-B14W-02 Dimensions: 2.15" x 9.00" x 1.57" [54.5mm x 228.6mm x 40.0mm] This drawing is a graphical representation of the product and may not show all fine details. Reference File: D1U54-D-650-12-HBxC (M1878-M1879)_Drawing for Product Datasheet_20151216.pdf OPTIONAL ACCESSORIES Description Part Number 12V D1U54P Output Connector Card D1U54P-12-CONC APPLICATION NOTES Document Number Description Link ACAN-64 D1U54P Output Connector Card http://power.murata.com/datasheet?/data/apnotes/acan-64.pdf ACAN-60 D1U54-x Communication Protocol http://power.murata.com/datasheet?/data/apnotes/acan-60.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048 -1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2016 Murata Power Solutions, Inc. www.murata-ps.com/support D1U54-D-650-12-HBxC.A02 Page 9 of 9