P9000 Series Digitally Compensated Pressure Transducer The new P9000 Series is the latest addition to the SchaevitzTM family of advanced digitally compensated pressure transducers. The unique design of the P9000 pressure transducer utilizes the proven reliability of strain gauge technology and innovative digital compensation electronics. The synergy of these technologies result in an instrument grade pressure transducer with the highest level of performance offered by Lucas Control Systems, Schaevitz Sensors. Available in pressure ranges from 75 psi to 10,000 psi (5 bar to 700 bar), the P9000 series can be configured with a variety of pressure ports, electrical outputs, and termination options to meet most pressure sensing needs. The P9000 Series incorporates 12 bit digital compensation electronics to ensure precise calibration of all critical parameters. This unique circuit design also provides a significant advantage of maintaining a true analog "thrupath" resulting in an exceptionally fast response of 1000 Hz without a sacrifice in accuracy. Error contribution sources are digitally corrected to guarantee repeatable performance and eliminate the need for user calibration. Combined nonlinearity hysteresis and non-repeatability errors are guaranteed to be less than 0.08% F.R.O. with total thermal error limited to 0.004% F.R.O/C over an extended industrial temperature range of -4F to 185F (-20C to 85C). Features Guaranteed accuracy of less than 0.08% F.R.O. The P9000 series delivers the advantages of a 17-4 PH diaphragm offering a true stainless steel isolation barrier with high burst pressures, at 20x the rated pressure, and a proof pressure, up to 5x the rated pressure. Housed in a rugged 316 stainless steel, NEMA 4X, IP67 enclosure with guaranteed shock resistance of up to 1000g for 2msec, and vibration to 20g, the P9000 provides a robust solution for a wide variety of demanding pressure applications and environments. Intrinsically safe option to class EEx ia IIc T4 (Tamb=60C) BASEEFA CENELEC EN50-020 Rugged stainless steel construction Pressure ranges: 0-75 psi to 10,000 psi (0 - 5 bar to 0 - 700 bar) 5x overload capacity IP67, NEMA 4x rated Available in both cable and connector outlets, the P9000 is offered in various electronic outputs: four wire 0-10 V, four wire 0 to 5 V and a 2 wire 4-20 mA intrinsically safe certified version. The P9000 can be configured to give 3 wire 1 to 6V or 1 to 11V output. All P9000 units are constructed under an ISO 9001 environment. Each unit is serialized and shipped with a calibration certificate guaranteeing the highest quality and reliability found in an instrument grade pressure transducer. Long term stability 0.1% F.R.O. per annum Thermal performance: <0.002% F.R.O./F (<0.004% F.R.O./C) Select models are CE certified Applications Hydraulic and pneumatic controls Steel and aluminum rolling mills Pulp and paper mills Automotive test stands Power generation Off-shore oil exploration Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (01753) 537622 156 Select P9000 models, when correctly installed, are CE certified to comply with the EMC Directive 89/336/EEC Generic Standards for Residential, Commercial, Light Industrial and Industrial Environments. P9000 Series Foil Strain Gauge Pressure Ranges: 0-75 to 0-10,000 psi (0-5 to 0-700 bar) Nonlinearity: <0.08% F.R.O. Specifications by Model (All specifications are at 20C unless otherwise noted) Series P9060 P9070 P90801 Model Numbers P9061/4 P9071/4 P9081/4 Input Voltage 10 to 36 VDC 15 to 36 VDC 10 to 36 VDC Current (mA) max <6 <6 N/A Output (F.R.O.) 5 V 0.3% 10 V 0.3% 4-20 mA (16 mA 0.3%) Impedance (ohms) <1 <1 -- Load Resistance (Ohms Min.) 1000 2000 1300 max at 36 V Frequency Response 1 kHz 1 kHz 1 kHz Combined Nonlinearity, Hysteresis and Nonrepeatability High Range % F.R.O. (BSL) <0.05 typ <0.05 typ <0.05 typ <0.08% max Combined Thermal Zero & Sensitivity Error: (calculated from end points of temp. range) The output will not deviate from 20C by more then 0.5% F.R.O., over a temperature range of -20 to +80C. % F.R.O./F <0.002 <0.002 <0.002 % F.R.O./C <0.004 <0.004 <0.004 Residual Unbalance % F.R.O. <0.3 <0.3 <0.3 Weight oz (gm) max (0001 version) Connector Version 5.11 (145) 5.11 (145) 5.11 (145) Cable Version 6.35 (180) 6.35 (180) 5.64 (160) 1 Model P9080 is registered as an intrinsically safe transducer to Class ia IIc T4 BASEEFA, Cenelec EN50 - 020. Common Specifications (all specifications are at 20C unless otherwise noted) Pressure Ranges High psi .................. 0-75; 100; 150; 200; 250; 350; 500; 750; 1000; 1500; 2200; 2500; 3500; 5000; 7500; 10,000 bar ................. 0-5; 7; 10; 15; 20; 25; 35; 50; 70; 100; 150; 200; 250; 350; 500; 700 Pressure References High Pressure Range .... Vented gauge3: 0-75 to 0-350 psi Absolute and sealed gauge: 0-75 to 0-10,000 psi Pressure Limit ................... 5x full range scale pressure or 12,000 psi (830 bar), whichever is less Burst Pressure ................... 20 x rated pressure range or 22,000 psi (1500 bar), whichever is less Pressure Media ................. Liquids or gases compatible with 17-4 PH and 17-7 PH stainless steel Temperature Range Operable ........................ -40F to 212F (-40C to 100C) Compensated ................. -4F to 176F (-20C to 80C) Storage ........................... -40F to 257F (-40C to 125C) Humidity Connector Version ........ 95% Relative Humidity Cable Version ................ Immersible to IP67 (fluid must not enter ends of cables) Vibration ............................ Surpasses MIL STD 810C Method 514-2 Curve L Shock ................................. 1000g for 2 msec will not damage sensor Insulation Resistance ....... 500 Mohm at 50 VDC Long Term Drift ................ <0.1% F.R.O./year (<0.25% F.R.O. for first 6 months) EMC ................................... CE Approved The P9060, P9070 and P9080 Series when correctly installed comply with the EMC Directive 89/336/EEC Generic Standards for Residential Commercial, Light Industrial and Industrial environments. Note: The Industrial environment cannot be complied with when the P9080 series is used in Intrinsic Safety applications where only one earth connection is made. 3 Vented gauge units must only be used in dry, noncorrosive environments and will breathe through the cable vent tube or hole in the 6-way receptacle. 157 P9000 Series Advanced Digitally Compensated Pressure Transducer Dimensions in (mm) Thread G1/4B [BSP] x 0.55 (14.0) Deep 3.50 (89.0) 75-750 psi 3.562 (90.5) 751-10,000 psi 0.51 (13.0) O1.00 (25.4) 0.756 (19.2) A /F Connector Outlet (P90X3-XXXX) 39.37 (1M) Standard (P90X1-XXXX) Adapters B A Adaptor, Welded 0.67 (17.0) A /F B A Bonded Seal Code Thread Size Welded G1/4A (BSP) (M) 0002 M14 x 1.5 (M) 0003 7/16"-20UNF-2A (M) 0004 1/4"-18NPT (M) 0005 M10 x 1.0 (F) 0006 Dimensions in (mm) A B 0.46 (11.7) 0.67 (16.9) 0.40 (10.2) 0.61 (15.4) 0.56 (14.3) 0.77 (19.5) 0.55 (14.0) 0.76 (19.2) -- 0.60 (15.2) Thread Size Screwed G1/4A (BSP) (M) 0022 M14 x 1.5 (M) 0023 7/16"-20UNF-2A (M) 0024 1/4"-18NPT (M) 0025 M10 x 1.0 (M) 0026 A 0.46 (11.7) 0.40 (10.2) 0.56 (14.3) 0.55 (14.0) -- B 0.70 (17.8) 0.62 (15.8) 0.78 (19.8) 0.80 (20.4) 0.60 (15.2) Adaptor, Screwed Connections Cable Connector** Red* White Yellow Blue* Violet Grey Pin A* Pin D Pin B Pin C* Pin E Pin F Connector Orientation VG. Excitation (+) Excitation (-) Output (+) Output (-) No connection Factory use only A A F B F E C E D 158 B C D Connector Orientation Note: Screen is connected to the case for CE marked units. Screen is not connected to the case for optional IS units (P9080). IS certification revokes CE certification. * 2-wire connections (max cable length 50 meters when IS) **Vented gauge units must breathe through the receptacle (mating connector must have a vent hole) Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (01753) 537622 A & SG. Select P9000 models, when correctly installed, are CE certified to comply with the EMC Directive 89/336/EEC Generic Standards for Residential, Commercial, Light Industrial and Industrial Environments. P9000 Series Foil Strain Gauge Pressure Ranges: 0-75 to 0-10,000 psi (0-5 to 0-700 bar) Nonlinearity: <0.08% F.R.O. Wiring P9081/3 P9061/3 and 9071/3 Excitation +Ve A Red Output +Ve B Yellow Output +Ve A Red Output -Ve C Blue C Blue Output -Ve Excitation -Ve D White Pin E - No connection E Violet Pin F - Factory use only F Grey How to Order Specify by transducer excitation, electrical interface, pressure port, pressure range, units, and pressure reference. Example: P9061-0005-10 BA signifies a pressure transducer with 0 to 5 VDC output operating from 10-36V, cable outlet and 1/4 inch-18 NPT male pressure port, pressure range of 0 to 10 bar, with an absolute pressure reference. Model Number Code P90 Corrosion resistant pressure transducers are available with wetted parts manufactured from Inconel 625 - consult factory for specifications. 0 Input/Output 6 - 0 to 5 V output (10 to 32 V supply) 7- 0 to 10 V output (15 to 36 V supply) 8 - 4-20 mA output (10-36 V supply) Unit B: bar P: psi Pressure Reference A: absolute SG: sealed gauge VG: vented gauge Cable/Connector (Please reference to selected pressure range) 1 - High Range - cable outlet 3 - High Range - connector outlet Intrinsic Safety 0 - Non IS 9 - IS (P9080 only) Unit 0 - Welded Adapter 2 - Screw in Adapter Pressure Port 1 - 1/4 in BSP female 2 - 1/4 in BSP male 3 - M14 x 1.5 male 4 - 7/16 in 20 UNF 2A male 5 - 1/4 in 18 NPT male 6 - M10 x 1 female 159 Pressure Range (Enter full scale pressure range without units) High (psi) 0-75; 100; 150; 200; 250; 350; 500; 750; 1000; 1500; 2200; 2500; 3500; 5000; 7500; 10,000 (bar) 0-5; 7; 10; 15; 20; 25; 35; 50; 70; 100; 150; 200; 250; 350; 500; 700