PCB Relay G6S Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-L terminal. High dielectric strength between coil and contacts (2,000 VAC), and between contacts of different polarity (1,500 VAC). High impulse withstand voltages between coil and contacts, and between contacts of different polarity (2,500 V, 2 10 s: Bellcore requirements). Low power consumption (140 mW). Bifurcated crossbar contact (Au-clad) and Fully sealed construction for high reliability. Applicable to IRS. High sealability after IRS. Ultra-miniature at 15 7.5 9.4 mm (L W H). Through-hole terminal is available EN60950/EN41003 Supplementary Insulationcertified type is available. Ordering Information Classification DPDT Fully sealed Single-side stable Single-winding latching Double-winding latching Single-side stable EN60950/EN41003 G6S-2-Y Through-hole terminal G6S-2 G6SU-2 G6SK-2 Surface mounting terminal Inside-L G6S-2G G6SU-2G G6SK-2G G6S-2G-Y Outside-L G6S-2F G6SU-2F G6SK-2F G6S-2F-Y Note: 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F 12 VDC Rated coil voltage 2. When ordering tape packing, add -TR" to the model number. Example: G6S-2F-TR 12 VDC Tape packing Be sure since -TR" is not part of the relay model number, it is not marked on the relay case. Model Number Legend G6S@-@@-@ 1 2 3 4 @ VDC 5 1. Relay Function 4. Approved Standards None: Single-side stable U: Single-winding latching K: Double-winding latching 2. Contact Form None: UL/CSA Y: EN60950/EN41003 5. Rated Coil Voltage 2: DPDT 3. Terminal Shape None: Through-hole terminal G: Inside-L surface mounting terminal F: Outside-L surface mounting terminal 58 4.5, 5, 12, 24 VDC G6S G6S Specifications Coil Ratings Single-side Stable Type (G6S-2, G6S-2F, G6S-2G) Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 31.0 mA 28.1 mA 11.7 mA 8.3 mA Coil resistance 145 W 178 W 1,028 W 2,880 W Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 200% of rated voltage at 23C 170% of rated voltage at 23C Power consumption Approx. 140 mW Approx. 200 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G) Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 22.2 mA 20 mA 8.3 mA 6.3 mA Coil resistance Coil inductance (H) (ref. value) 203 W 250 W 1,440 W 3,840 W Armature OFF 0.27 0.36 2.12 5.80 Armature ON 0.14 0.18 1.14 3.79 Must set voltage 75% max. of rated voltage Must reset voltage 75% max. of rated voltage Max. voltage 180% of rated voltage at 23C Power consumption Approx. 100 mW Note: Approx. 150 mW 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G) Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 44.4 mA 40 mA 16.7 mA 12.5 mA Coil resistance Coil inductance (H) (ref. value) 101 W 125 W 720 W 1,920 W Set Armature OFF 0.12 0.14 0.60 1.98 Armature ON 0.074 0.088 0.41 1.23 Reset Armature OFF 0.082 0.098 0.46 1.34 Armature ON 0.14 0.16 0.54 2.23 Must set voltage 75% max. of rated voltage Must reset voltage 75% max. of rated voltage Max. voltage 170% of rated voltage at 23C 140% of rated voltage at 23C Power consumption Approx. 200 mW Approx. 300 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y) Rated voltage 5 VDC 12 VDC 24 VDC Rated current 40 mA 16.7 mA 9.6 mA Coil resistance 125 W 720 W 2,504 W Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 170% of rated voltage at 23C 170% of rated voltage at 23C Power consumption Approx. 200 mW Approx. 230 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 59 G6S G6S Contact Ratings Load Resistive load (cosf = 1) Rated load 0.5 A at 125 VAC; 2 A at 30 VDC Contact material Ag (Au-clad) Rated carry current 2A Max. switching voltage 250 VAC, 220 VDC Max. switching current 2A Max. switching power 62.5 VA, 60 W Failure rate (reference value) Note 10 A at 10 mVDC P level: l60 = 0.1 x 10 /operation -6 Characteristics Contact resistance 75 mW max. Operate (set) time 4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms) Release (reset) time 4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms) Bounce time Operate: Approx. 0.5 ms Release: Approx. 0.5 ms Set/Reset: Approx. 0.5 ms Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MW min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching) 1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching) Impulse withstand voltage 2,500 V (2 x 10 s) between coil and contacts 1,500 V (10 x 160 s) between coil and contacts (double-winding latching) 2,500 V (2 x 10 s) between contacts of different polarity 1,500 V (10 x 160 s) between contacts of same polarity (conforms to FCC Part 68) Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 (approx. 100G) Malfunction: 750 m/s2 (approx. 75G) Endurance Mechanical: 100,000,000 operations min. (at 36,000 operations/hr) Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr) 100,000 operations min. (0.5 A at 125 VAC, resistive load) Ambient temperature Operating: -40C to 85C (with no icing), -40C to 70C (double-winding latching, 24 VDC) Ambient humidity Operating: 5% to 85% Weight Approx. 2 g Approved Standards UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR24825) Model G6S-2, G6S-2F, G6S-2G Contact form DPDT Coil ratings 1.5 to 48 VDC G6SU2, G6SK-2, G6SU-2F, G6SU2G, G6SK-2F, G6SK-2G 1.5 to 24 VDC Contact ratings 2 A, 30 VDC 0.3 A, 110 VDC 0.5 A, 125 VAC EN60950/EN41003 Model G6S-2-Y, G6S-2G-Y, G6S-2F-Y 60 Contact form DPDT Isolation category Supplementary Isolation Voltage 250 VAC G6S G6S Engineering Data Maximum Switching Power Ambient Temperature vs. Maximum Coil Voltage DC resistive load Single-winding Latching Double-winding Latching Maximum coil voltage (%) AC resistive load Maximum coil voltage (%) Switching current (A) Single-side Stable 12 VDC max. 24 VDC (G6S-Y, 12 VDC max.) 24 VDC (G6S-Y) Ambient temperature (C) Switching voltage (V) G6SU G6SK 12 VDC max. G6SK 24 VDC Ambient temperature (C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Reference Data Ambient Temperature vs. Switching Current Single-winding Latching Double-winding Latching 12 VDC max. 24 VDC (G6S-Y) 24 VDC (G6S-Y, 12 VDC max.) Operating current (A) Switching current (A) Single-side Stable G6SU 12 VDC max. G6SU 24 VDC G6SK 12 VDC max. G6SK 24 VDC Ambient temperature (C) Ambient temperature (C) Recommended Soldering Time vs. Surface PCB Temperature Temperature ( C) (The temperature profile indicates the temperature on the surface of the PCB.) IRS Soldering Preheating Time (s) 61 G6S G6S Dimensions Note All units are in millimeters unless otherwise indicated. Single-side Stable G6S-2, G6S-2-Y Tolerance: 0.3 Footprint (Bottom View) Tolerance: 0.1 Eight, 1-dia. holes G6S-2F, G6S-2F-Y Tolerance: 0.3 Footprint (Top View) Tolerance: 0.1 Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark G6S-2G, G6S-2G-Y Tolerance: 0.3 Footprint (Top View) Tolerance: 0.1 Terminal Arrangement/ Internal Connections (Top View) Orientation mark 62 G6S G6S Single-winding Latching G6SU-2 Tolerance: 0.3 Footprint (Bottom View) Tolerance: 0.1 Eight, 1-dia. holes G6SU-2F Tolerance: 0.3 Footprint (Top View) 7.3+0.2 G6SU-2G Tolerance: 0.3 7.3+0.2 Tolerance: 0.1 Footprint (Top View) Tolerance: 0.1 Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark 63 G6S G6S Double-winding Latching G6SK-2 Tolerance: 0.3 Footprint (Bottom View) Tolerance: 0.1 Ten, 1-dia. holes G6SK-2F Tolerance: 0.3 Footprint (Top View) Tolerance: 0.1 Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark G6SK-2G Tolerance: 0.3 7.3+0.2 Footprint (Top View) Tolerance: 0.1 Terminal Arrangement/ Internal Connections (Top View) Orientation mark 64 G6S G6S Tape Packing When ordering, add "-TR" before the rated coil voltage for tape packing. Tape type:TE2416R (Refer to EIAJ) Reel type:R24E (Refer to EIAJ) Relays per reel:400 29.51.0 25.50.5 20.3 210.5 G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y 330 80 R1.0 130.2 G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y Cover tape Carrier tape Emboss tape Orientation mark Feed direction Precautions Use a DC power supply with 5% or less ripple factor to operate the coil. Do not use the G6S where subject to strong external magnetic fields. Do not use the G6S where subject to magnetic particles or excessive amounts of dust. Do not reverse the polarity of the coil (+, -). Latching types are delivered in the reset position. We recommend that a reset voltage be applied in advance to start operation. Do not drop the G6S or otherwise subject it to excessive shock. Remove the relay from the packing immediately prior to usage. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K093-E1-2D 65