60
G6SG6S
■Contact Rating s
Note P level: l60 = 0.1 x 10-6/operation
■Characteristics
■Approved Standards
UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR24825)
EN60950/EN41003
Load Resistive load (cos
f
= 1)
Rated load 0.5 A at 125 VAC; 2 A at 30 VDC
Contact material Ag (Au -clad)
Rated carry current 2 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 2 A
Max. switching power 62.5 VA, 60 W
Failure rate (reference value) 10 µA at 10 m VDC
Contact resistance 75 m
W
max.
Operate (set) time 4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms)
Release (reset) time 4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms)
Bounce time Operate: Approx. 0.5 ms
Release: Approx. 0.5 ms
Set/Reset: Approx. 0.5 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 M
W
min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching)
Impulse withstand voltage 2,500 V (2 x 10 µs) between coil a nd contacts
1,500 V (10 x 160 µs) between coil and contacts (double-winding latching)
2,500 V (2 x 10 µs) between contacts of different polarity
1,500 V (10 x 160 µs) between contacts of same polarity (conforms to FCC Part 68)
Vibration resistance Destruct ion: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 750 m/s2 (approx. 75G)
Endurance Mec hanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr)
100,000 operations min. (0.5 A at 125 VAC, resistive load)
Ambient temperature Operating:
-
40°C to 85°C (with no ic ing),
-
40°C to 70°C (double-winding latching, 24 VDC)
Ambient humidity Operating: 5% to 85%
Weight Approx. 2 g
Model Contact form Coil ratings Contact ratings
G6S-2, G6S-2F, G6S-2G DPDT 1.5 to 48 VDC 2 A, 30 VDC
0.3 A, 110 VDC
0.5 A, 125 VAC
G6SU2, G6 SK-2, G6SU-2F,
G6SU2G, G6SK-2F, G6SK-2G 1.5 to 24 VDC
Model Contact form Isolation catego ry Voltage
G6S-2-Y, G6S-2G-Y, G6S-2F-Y DPDT Supplementary Isolation 250 VAC