Delay Units Digitally Programmable series: PDU-1016 (4-Bit) ECL Interfaced Features: @ Input & output ECL buffered g@ 4-BIT ECL programmable delay line m@ Output same polarity of input @ Completely interfaced @ Compact & low profile 0 = Logic 0 1 = Logic 1 @ = Dont care. T, = Reference or inherent delay of unit. T,T,, = Multiplier of incremental delay. DATA DELAY DEVICES Inc. @ 385 Lakeview Avenue, Specifications: B Input signal requirement: ECL logic @ Output fan-out: ECL loads @ Delay variation: Monotonic in one direction g Programmed delay tolerance: +5% or 1 NS whichever is greater @ Inherent delay: 11 NS + 1 NS for PDU-1016-1 thru -5, Greater for rest of part numbers. B@ Power dissipation: 615 MW typ. @ Supply voltage: 5 Vdc @ Operating Temperature: 0-70C m@ Temperature Coefficient: 100 PPM/C Part No. PDU-1016-.5 PDU-1016-1 PODU-1016-2 PDU-1016-3 PDU-1016-4 PDU-1016-5 PDU-1016-6 PDU-1016-8 PDU-1016-10 PDU-1016-12 PDU-1016-15 PDU-1016-20 PDU-1016-25 PDU-1016-30 POU-1016-35 PDU-1016-40 PDU-1016-45 PDU-1016-50 PDU-1016-60 PDU-1016-80 PDU-1016-100 17 Test Conditions @ Input pulse-width: 2=150% of Max. delay. @ Input pulse spacing: =3 times of Max. delay. @ Input pulse voltage: ECL logic. . @ Measurements taken @ T, = 25C, Vee = 5V. Clifton, New Jersey 07011 @ (201) 772-1106 = TWX 710-989-7008