V-Series Switch Product Highlights: Maximum sealing protection with dual seals around lamps and rocker stem certified to IP66 & IP68. Optional panel seals for additional protection. Silver plated butt contact mechanism provides 50 to 100 thousand electrical cycles and a variety of different electrical ratings. Roller pin mechanism does not require lubricants and allows the switch to withstand extreme temperatures. The switch base accommodates up to 10 terminals and a large variety of switch and lighting circuits. The multi-step mounting wings provide a secure fit for panel thicknesses of 0.032" thru 0.250" in an industry standard 0.830" x 1.450" mounting hole. The switch connector allows the user to preload FQC terminals for easy assembly to switch base. Numerous choices of removable rockers allow for style change without having to retest or re-qualify the switch base. Illumination options are endless with bar, oval, and square lenses available in choices of incandescent, neon and a wide variety of LEDs including superbrite, megabrite, flashing and bicolor lighting. Available with a variety of complimentary mounting panels, hole plugs, illuminated indicators and boots to accommodate most any design need. Carling Technologies, Inc. 60 Johnson Avenue * Plainville, CT 06062-1177 Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com CONTURA III CONTURA V CONTURA II CONTURA VII Carling Technologies' fully sealed V-Series Contura switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These switches are a staple in the marine and transportation industries and have passed a range of environmental, corrosion, temperature, vibration, shock and sealing tests including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC 60529 and BS 5490 among others, making them one of the most rugged and reliable switches ever manufactured. 2 | V-Series Contura Sealed Rocker Switches V-Series Switch DESIGN FEATURES MAXIMUM DESIGN OPTIONS WITH MINIMUM INVENTORIES Panel redesign is a snap, requiring no tooling change, with our removable interchangeable actuators. A unique balance between aesthetics and functionality. SEALS OUT WATER, DUST AND DEBRIS Dual seal protection locks out elements. Certified to IP66/IP68 for front panel components. CLEAN CONNECTIONS Offered in both eight and ten terminal base options. AMP & Packard compatible connectors available. SILVER PLATED BUTT Contact mechanism provides 50 to 100 thousand electrical cycles and a variety of different electrical ratings. OPTIONAL PANEL SEAL Prevents water/dust egress behind panel. MULTIPLE LIGHTING OPTIONS Incandescent lamps & LED lighting. Our LED illumination is offered in a wide array of light intensities, colors, as well as dual level, tri-color, and flashing options. WITHSTANDS EXTREME TEMPERATURES Roller pin mechanism eliminates the need for lubricants. Enables switch to withstand -40C to +85C temperatures. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura Sealed Rocker Switches & Illuminated Plug | 3 V-Series Contura Switches V-Series switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable actuators in a choice of actuator styles and colors, and are available in single or double pole configurations. The V-Series switches can be illuminated with either square, oval and/or bar shaped lenses. Contura II & III Contura X The Contura II & III actuators are constructed of thermoplastic polycarbonate and are offered with a hard nylon overlay or a "soft-touch" elastomer overlay. These models incorporate aesthetic designs on the top and bottom of the rocker featuring two rows of raised "bumps" on the Contura II and three "indented" lines on the Contura III. The raised bracket/bezel on the Contura X helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This curved rocker style is available with a variety of lenses and legends. Contura IV The Contura IV's "Shape to create a Shape" actuator works with the curves, contours & advanced styling of the latest panel designs, flowing with these advanced curves & radii. This actuator style fits on the Contura flush bracket/ bezel. Contura V The symmetrically curved Contura V actuator provides the perfect complement to the Contura IV's "Shape to create a Shape" design concept. With its flush style mounting bracket, Contura V can be mounted in between two Contura IV's, by itself, or in groups. Contura VI (WAVE) The Contura VI WAVE sealed rocker switches, when used in a row, create an uniquely appealing "wave" design on your panel. A variety of colors and finishes are available for both rocker and wave insert. Contura VI features bar and oval lenses. Contura XI The raised bracket/bezel on the Contura XI helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This convex style rocker is available with a wide variety of lenses and legends. Contura XII The Contura XII version features a paddle style actuator with the raised bracket/bezel of Contura X and XI. The contoured handle design provides intuitive recognition and ease of operation and is available with all Contura X and XI lens and legend offerings. Illuminated Indicator The Illuminated Indicator is offered with removable/ replaceable lamps and Contura II, III, V, or X styling. Illumination alerts the operator of essential system functions or malfunctions like: oil pressure, high temperature, fluid levels, parking brake, or general system malfunction. Contura VII Contura VII featuring gently curved corners and edges assuring compatibility with most any panel design. Intuitive feel is maximized by the use of 2 embossed circular pads located at opposite ends of the rocker. Any combination of Bar or Oval style lenses can be located in the pads providing a truly unique look, exclusive to Contura VII. V-Series Accessories/Options Carling Technologies also offers many V-Series accessories including connectors, mounting panels, hole plugs, panel seals, and actuator removal tools. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 4 | V-Series Contura Sealed Rocker Switches Electrical Contact Rating 4VA @ 28VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC 10A, 14VT 6A, 125VAC L Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 50,000- 100,000 cycles circuit dependent Contacts Silver alloy, silver tin-oxide, fine silver Terminals Brass or copper/silver plate 1/4" (6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead Agency Certifications Environmental Environmental Corrosion Mechanical Endurance 150,000 cycles minimum circuit dependent Physical Lighted Seals Base Contura II, III, IV, V, VI Actuator Operating Temperature Vibration 1 Incandescent - rated 10,000 hours Neon - rated 25,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Internal Optional external gasket panel seal Polyester blend rated to 125C with a UL flammability rating of 94V0. Hard Surface: Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate with an elastomer overlay. Contura X, XI, XII Actuator, VP Nylon 66 Reinforced rated to 105C Lens Polycarbonate rated at 100C Actuator Travel (Angular Displacement) 2 position 3 positions 18 9 from center Mounting Specifications Panel Thickness Range # of gaskets Acceptable Panel Thickness 0 .030 to .250 (.76mm to 6.35mm) 1 .030 to .109 & .147 to .157 (.76 to 2.77mm & 3.73 to 3.98mm) Recommended: No gasket with panel thickness of .032, .062, .093, .125,.187 or .250 Vibration 2 Shock Salt Spray Dust Thermal Shock Moisture Resistance .830[21.08] 1.450[36.83] TEST CUT HOLE IN ACTUAL MATERIAL SWITCH MOUNTING HOLE Ignition Protection Sealed version: IP68, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. The standard test for immersion under pressure requires submersion under one meter of water for 30 minutes. The V-Series switch has exceeded these parameters, having been actuated and illuminated during submersion. Flowing Mixed Gas (FMG) Class III 3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts -40C to + 85C Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G's 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Resonance search 24-50 Hz 0.40 DA 50-2000 10 G's peak Results Horizontal Axis 3-5 G's max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10 seconds chatter. Per Mil-Std 202F, Method 213B, Test Condition K @ 30G's. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Sealed version only. Per Mil-Std 810C, Method 510.2 Air Velocity 300 200 Feet/Min, Test Duration 16 Hrs. Per Mil-Std 202F, Method 107F, Test Cond. A, -55C to 85C. Test criteria pre and post test contact resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance All Contura switches with sealed construction meet the requirements of UL1500/ISO8846 for ignition protection, in addition to conformance with EC directive 94/25/EC for marine products. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura II, III, & IV | 5 Dimensional Specifications: in. [mm] 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 6 | V-Series Contura V, VI & VII Dimensional Specifications: in. [mm] CONTURA V CONTURA V SHOWN WITH BAR LENS SHOWN WITH LOW PROFILE LOCK 1.922[48.56] 1.922[48.56] 1.079 [27.40] 1.550 [39.37] .505 [12.83] .250 [6.35] X .031 [.78] .250 [6.35] X .031 [.78] .820 [20.83] .960 [24.38] 8 TERMINAL BASE W/O BARRIERS 7 8 1 2 5 2 5 3 6 3 6 1 SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE 10 .820 [20.83] 10 TERMINAL BASE W/O BARRIERS 4 8 10 TERMINAL BASE W/O BARRIERS 0.985 [25.02] .250 [6.35] .031 [.78] .960 [24.38] .960 [24.38] 8 TERMINAL BASE W/BARRIERS 2.029 [51.53] 1.000 [25.40] .250 [6.35] X .031 [.78] .390 [9.90] 1.922[48.82] 10 TERMINAL BASE W/BARRIER AND LAMP TERMINAL 1.020 [25.91] .505 [12.83] SHOWN WITH LARGE LENS AND BAR LENS 1.126 8 TERMINAL BASE W/O BARRIERS 1.020 [25.91] CONTURA VII SHOWN WITH OVAL LENS 1.950[49.53] .080[2.03] 1.479 [37.57] 8 TERMINAL BASE W/BARRIERS CONTURA VI .820 [20.83] .960 [24.38] 10 TERMINAL BASE W/O BARRIERS 7 4 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura X, XI & XII | 7 Dimensional Specifications: in. [mm] CONTURA X STYLE CONTURA XI STYLE SHOWN WITH RAISED BRACKET .350[8.89] .667 [16.94] 1.910[48.51] CONTURA XII STYLE SHOWN WITH RAISED BRACKET AND TWO SQUARE LENSES 1.910[48.51] .426[10.82] .350[8.89] 1.586[40.28] SHOWN WITH PADDLE ACTUATOR 1.305[33.15] 1.506[38.25] 1.370[34.79] 1.370[34.79] 8 TERMINAL BASE W/BARRIERS 1.370[34.79] 10 TERMINAL BASE W/O BARRIERS .960[24.38] 8 TERMINAL BASE W/O BARRIERS .960[24.38] .960[24.38] .780[19.81] .780[19.81] .780[19.81] .250[6.35] X .031[.78] .390[9.90] .390[9.90] .820[20.82] .820[20.82] 10 TERMINAL BASE W/BARRIERS 8 TERMINAL BASE W/BARRIERS SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL .390[9.90] .820[20.82] 10 TERMINAL BASE W/O BARRIERS 8 1 7 4 8 7 1 4 2 5 2 5 3 6 3 6 BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE 10 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 8 | V-Series Contura V & VI - Circuit Diagram CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM 3 1 3 A 2 3 3 3 3 1 3 4 2 1 6 3 4 6 3 1 4 6 5 3 6 2 5 6 SYMBOL LEGEND SYM. 2 5 3 4 DEFINITION DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION H 2 3 1 5 3 3 8 5 2 6 G 1 6 S 3 2 1 5 2 7 6 5 2 F 1 4 3 5 2 2 3 R 2 6 6 5 2 E 3 4 M 2 1 3 1 5 D 5 5 2 6 2 3 6 L 2 1 1 5 C 4 4 2 6 2 3 3 K 2 1 1 5 B 3 CIRCUIT DIAGRAM J 2 2 CIRCUIT 6 DESIGNATES MOMENTARY CIRCUITS DESIGNATES TWO POSITION CONNECTION 2 5 DESIGNATES EXTERNAL JUMPER PROVIDED BY CUSTOMER 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura X, XI & XII - Circuit Diagram | 9 LAMP CIRCUIT CIRCUIT DIAGRAM LAMP CIRCUIT +8 +8 A/1 F/6 1 G/7 2 SPECIAL #1 +3 M/R 2 2 SPECIAL #3 +1 +3 -4 J/8 +3 N/T 2 1 +6 1 -7 2 SPECIAL #4 +3 1 -7 -8 2 +6 1 +8 -6 -7 1 2 -7 2 +1 +3 +6 1 +8 -6 +3 H/Z -7 +1 +3 -4 P/V 2 -6 1 2 -7 +8 +1 +3 1 2 K/W U/Y 2 (-)7 CIRCUIT DIAGRAM CIRCUIT DIAGRAM 11 +6 1 -7 33 11 2 5 2 5 3 14 3 14 CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT 17 18 18 10(-) 17 10(-) J1 J1 13 11 +3 1 +8 C/3 11 13 L/9 CIRCUIT DIAGRAM -6 -7 +3 CIRCUIT +3 LAMP CIRCUIT -7 1 -7 CIRCUIT -6 2 +8 1 E/5 CIRCUIT DIAGRAM -7 +3 D/4 +3 1 -7 B/2 LAMP CIRCUIT CIRCUIT DIAGRAM 10(-) 1 10(-) 1 J5 J5 8 3 3 2 2 5 5 1 1 3 14 15 12 1311 3 14 15 12 6 16 6 16 JK JK 8 8 17 18 10(-) 1 J4 1 J4 2 11 13 3 14 17 18 10(-) 3 3 2 13 11 3 14 JJ 1 1 11 13 JJ 1 5 NOTE: J circuits are available for all non-locking V-Series styles. Consult factory for p / n details. 6 5 17 18 10(-) 5 6 8 J3 2 33 14 14 8 J3 2 CIRCUIT DIAGRAM 5 17 18 10(-) 3 3 1 -9 8 1 5 -7 8 1 5 2 JA 17 18 10(-) J2 1 JA 17 18 10(-) J2 +10 CIRCUIT DIAGRAM 11 13 13 11 17 18 17 18 2 2 8 CIRCUIT CIRCUIT +8 5 5 SYMBOL LEGEND SYM. SYMBOL LEGENDDEFINITION SYM. CIRCUIT DEFINITION DESIGNATES TERMINALS AND CONTACTS JA,JJ,JK J1,J3,J4,J5 DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION DESIGNATES LAMP LOCATION J2 CONNECTOR PART # JC1-01 JC2-01 JC3-01 DESIGNATES TWO POSITION CIRCUIT 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 2 10 | V-Series Contura II & III Sealed Rocker Switches V 1 D A B T 0 B -- A R B 00 -- 0 00 1 Series 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp 8 Bracket 11 Color 12 Legend 13 14 Legend Actuator Orientation Lens Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 3 RATING3 .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING 0 1 125VAC 4 3V No lamp Neon Incandescent LED* SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 B C D E F M N 10 Lens 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES V Position: 9 Actuator 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC 7 18V 8 24V superbright Red R S T V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal 9 ACTUATOR No Actuator Contura II Contura III White W Y 0 A B C D 3,6 Actuator orientation above terminals: 10 LENS 0 - No Actuator White Clear 6 1 7 2 8 3 Gray G H 1,4 Z - No Lens Amber Green B G C H D J Red M N P Blue T U V E F R S W Y Red R S White W Y Square lens options available only for Contura II: 9 A 4 5 K L Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR1 AND TEXTURE Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9Selections for Single Pole Switches Only: J 8 #1 Down 3+ 8&# 2 Independent 6+ 7K W #1 Independent 8+ 7&# 2 Independent 6+ 7Selections for Double Pole Switches Only: L 9 #1 Down 3+ 6M R #2 Up 3+ 6N T #1 Down 3+ 6&# 2 Down 1+ 4V #1 Up 1+ 4P &# 2 Up 3+ 6- 0 - No Actuator Soft Surface Hard Surface Black B C Gray G H 12 ACTUATOR LENS OR BODY LEGENDS2 11 ON OFF 12 OFF ON 13 | O 14 O | 15 O O FN F 16 O O FN F 17 O | 18 | O For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 1 2 3 4 ARCMC-100 MC No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 ORIENTATION 4 Orientation 4 ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 ORIENTATION 2 A9CE3-1E5 A9C45-200 E3 AC E5 SLEEPER LIGHTS 45 AZCAC-100 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Body legends not available on Soft surface actuators; White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Additional ratings available. See page 20. 4 Contura II available with two square lenses. Consult factory for details. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura II & III Locking Sealed Rocker Switches | 11 V 1 D A S W 0 B -- A Z E 00 -- 0 1 Series 2 Circuit 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 8 Bracket 11 Function 12 Legend 13 Legend Orientation Lamp above terminals 3 & 6 end of switch 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 3 RATING4 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC 7 18V 8 24V superbright Red R S T V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y Gray G H 9 HARD SURFACE ACTUATOR1 Contura II Black A Grey B Red G White H Contura III C D E F 3,6 Actuator orientation above terminals: 10 LENS Z - No Lens White Clear 8 3 Amber D Green J Red P Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 0 1 125VAC 4 3V No lamp Neon Incandescent LED* SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 B C D E F M N 10 Lens 7 LAMP 1 SERIES V Position: 9 Actuator 11 ACTUATOR LOCK FUNCTION AND COLOR1 Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE C 3 #2 Up 3+ 7H Z #2 Independent 8+ 7Selections for Double Pole Switches Only: R #2 Up 3+ 6M Lock Color Match Actuator Black White Red Safety Orange Lock above terminals 1 & 4 end of switch. W lock Down H J K L M Up & Down R S T V W Blue V Center3 1 2 3 4 5 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend 21 22 OFF ON 25 O F F 23 26 O N O 27 O 24 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 21-28 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION 1 ORIENTATION 4 AZC45-1 45 6 LOCK Up A B C D E 1,4 ORIENTATION 2 AZC45-2 45 ORIENTATION 3 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See page 20. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 12 | V-Series Contura IV Sealed Rocker Switches V 1 D A B T 0 B -- E R C 00 -- 0 00 1 Series 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp 8 Bracket 10 Lens 11 Color 12 Legend 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) 1 SERIES V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 Position: ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 4 3 RATING .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING 0 1 125VAC 4 3V No lamp Neon Incandescent LED* SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 B C D E F M N 9 Actuator 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC 7 18V 8 24V superbright Red R S T V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y Gray G H 9 ACTUATOR No Actuator Contura IV, left orientation Contura IV, left orientation, laser etched Contura IV, right orientation Contura IV, right orientation, laser etched Actuator orientation above terminals: 10 LENS 0 - No Actuator Clear White 1 6 2 7 3 8 4 9 5 A Z - No Lens Amber Green B G C H D J E K F L 1,4 0 E T F R 3,6 Red M N P R S Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR1,5,6 Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9Selections for Single Pole Switches Only: J 8 #1 Down 3+ 8&# 2 Independent 6+ 7K W #1 Independent 8+ 7&# 2 Independent 6+ 7Selections for Double Pole Switches Only: L 9 #1 Down 3+ 6M R #2 Up 3+ 6N T #1 Down 3+ 6&# 2 Down 1+ 4V #1 Up 1+ 4P &# 2 Up 3+ 6- No Actuator 0 Black C Gray H Red S White Y Blue T U V W Y E Nickel D F Pewter E 12 ACTUATOR LENS OR BODY LEGENDS2 11 ON OFF 12 OFF ON 13 | O 14 O | 15 O O FN F 16 O O FN F 17 O | 18 | O For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 E8C45-100 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 E3C70-200 F8C45-100 F3C70-200 ORIENTATION 1 ORIENTATION 2 ORIENTATION 4 E8C45-300 F8C45-300 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Gloss brow is on left side of E actuator and right side of F actuator. 4 Additional ratings available. See page 20. 5 Laser etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 6 Pewter and nickel colors only available with laser etched actuator. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura V Sealed Rocker Switches | 13 V 1 D A B T 0 B -- G R C 00 -- 0 00 1 Series 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp 8 Bracket 10 Lens 11 Color 12 Legend 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) 1 SERIES V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 Position: ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 4 3 RATING .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING 0 1 125VAC 4 3V No lamp Neon Incandescent LED* SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 B C D E F M N 9 Actuator 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y No Actuator Contura V Contura V, laser etched 0 G P 10 LENS Lens style & location: #1/ #2 Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator White Clear 6 1 7 2 8 3 9 4 A 5 No Actuator 0 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9Selections for Single Pole Switches Only: J 8 #1 Down 3+ 8&# 2 Independent 6+ 7K W #1 Independent 8+ 7&# 2 Independent 6+ 7Selections for Double Pole Switches Only: L 9 #1 Down 3+ 6M R #2 Up 3+ 6N T #1 Down 3+ 6&# 2 Down 1+ 4V #1 Up 1+ 4P &# 2 Up 3+ 6- Gray G H 9 ACTUATOR Z - No Lens Amber Green B G C H D J E K F L 11 ACTUATOR COLOR1,3,3 Jumper No No Yes T2 to 5 No No No No 7 18V 8 24V superbright Red R S T V Black C Gray H Red S Red M N P R S Blue T U V W Y White Y Nickel D bar bar/bar oval oval/bar oval/oval Pewter E 12 ACTUATOR LENS OR BODY LEGENDS2,6 11 ON OFF 12 OFF ON 13 | O 14 O | 15 O O FN F 16 O O FN F 17 O | 18 | O For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 4G13L 4G MC MA 4G MC MA MA3MC ORIENTATION 4 ORIENTATION 2 3L 4G200 MA1MC ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Laser Etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 4 Additional ratings available. See page 20. 5 Nickel and Pewter colors only available with laser etched actuator. 6 Consult factory for laser etched lens callout. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 14 | V-Series Contura IV & V Locking Sealed Rocker Switches V 1 D A S W 0 B -- J Z E 00 -- 0 2 Circuit 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 8 Bracket DP A D J K L N ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7& 8 for lamp circuit only. Terminals 9 & 10 are not used with locking style switches. 1 2 & 3, 5 & 6 ON ON ON ON (ON) OFF 2 Connected Terminals NONE NONE OFF OFF OFF NONE 3 1 & 2, 4 & 5 OFF ON ON (ON) (ON) ON .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE C 3 #2 Up 3+ 7H Z #2 Independent 8+ 7Selections for Double Pole Switches Only: R #2 Up 3+ 6M 6 LOCK Lock above terminals 1 & 4 end of switch. W low profile lock Y6 0 1 125VAC 4 3V No lamp Neon Incandescent LED* 3 RATING4 1 B C D E F M N 12 Legend 13 Legend Orientation high profile lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See page 20. 5 Located at T3-6 end of switch. 6 Contura V style only. 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC 7 18V 8 24V superbright Red R S T V 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y Gray G H 9 HARD SURFACE ACTUATOR CONTURA IV: Orientation Left Black J Grey K Red L Right N P R CONTURA V: Black U Grey V Red W 10 LENS5 Z - No Lens White Clear B A H G Amber C J White M S Actuator orientation above terminals: 3,6 1,4 Actuator orientation above terminals: 3,6 1,4 White Y Green D K Red E L Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR1 Lock Color Match Actuator Black White Red Safety Orange Gray Up A B C D E F Down H J K L M G Up & Down R S T V W N Blue bar lens F oval lens M Center3 1 2 3 4 5 6 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend 21 22 OFF ON 25 O F F 26 O N 23 O 27 O 24 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 1 2 3 4 ORIENTATION 1 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 JHAY3-100 JHAY3-200 JHAY3-300 ORIENTATION 2 Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 SP 1 4 6 7 8 9 11 Function Lamp above terminals 3 & 6 end of switch CIRCUIT3 Position: 10 Lens 7 LAMP 1 SERIES V 2 9 Actuator ORIENTATION 4 1 Series P P P P P P NHAY3-100 NHAY3-200 NHAY3-300 ORIENTATION 3 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura VI WAVE Sealed Rocker Switches | 15 V 1 D B G N T B - H A 7 C B AC - 1 00 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 11 Lens 12 Color 13 Insert Color 14 Actuator Lens 15 16 Legend Actuator Orientation Lens Legend Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 Position: ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 3 RATING3 .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 10 term 2 B K 4 D 6 F Termination .250 TAB (QC) no barriers .250 TAB (QC) with barriers .250 TAB (QC) no barriers Solder Lug no barriers Solder Lug Wire Leads no barriers Wire Leads 5 ILLUMINATION & SWITCH SEALING 0 1 125VAC 4 3V No lamp Neon Incandescent LED* SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 8 term 1 A J 3 C 5 E 10 Lens 6,7 LAMP (same coding for both selections) 1 SERIES V 1 B C D E F M N 9 Actuator 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J Red A B C D 2VDC 6VDC 12VDC 24VDC * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y 9 ACTUATOR 0 Gray G H H High Insert No Actuator Low Insert Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator White Clear 7 - - 3 - 4 A - C Z - No Lens Amber Green C H D J E K F L H Black S Gray Red 13 INSERT COLOR B C D Red N P R S Y Blue U V W Y Bar Lens Translucent Bar Lens Transparent Oval Lens Transparent Oval Lens Translucent White N Bright Nickel Plated S Satin Chrome Plated T Satin Nickel Plated W White Black Bright Chrome Plated Satin Chrome Painted 14 ACTUATOR LENS OR BODY LEGENDS2 00 - No Legend this location/No actuator 11 ON OFF 12 OFF ON 13 | O 14 O | 15 O O FN F 16 O O FN F 17 O | 18 | O For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog Orientation 1 15 LEGEND ORIENTATION 0 1 2 3 4 VTHAACN-MC1MC No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 VTHA7CN-3M100 VTHWZCB-45146 VTLSZSC-70100 VTLLFHC-A813H VTLDECC-001MG 16 ACTUATOR LENS LEGEND Orientation 2 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9Selections for Single Pole Switches Only: J 8 #1 Down 3+ 8&# 2 Independent 6+ 7K W #1 Independent 8+ 7&# 2 Independent 6+ 7Selections for Double Pole Switches Only: L 9 #1 Down 3+ 6M R #2 Up 3+ 6N T #1 Down 3+ 6&# 2 Down 1+ 4V #1 Up 1+ 4P &# 2 Up 3+ 6- L 10,11 LENS4 12 ACTUATOR COLOR Jumper No No Yes T2 to 5 No No No No 7 18V 8 24V superbright Red R S T V Orientation 4 1 Series Orientation 3 3 1 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be 2 4 specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, 3 red and gray actuators; Custom colors are available, consult factory. 3 Additional ratings available. See page 20. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 16 | V-Series Contura VII Sealed Rocker Switches V 1 D A B T 0 B -- Z R C 00 -- 0 00 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp 8 Bracket 11 Color 12 Legend 13 14 Legend Actuator Orientation Lens Legend 3 3 RATING4 .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING Jumper No No Yes T2 to 5 No No No No Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Lamp wired to Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9Selections for Single Pole Switches Only: J 8 #1 Down 3+ 8&# 2 Independent 6+ 7K W #1 Independent 8+ 7&# 2 Independent 6+ 7Selections for Double Pole Switches Only: L 9 #1 Down 3+ 6M R #2 Up 3+ 6N T #1 Down 3+ 6&# 2 Down 1+ 4V #1 Up 1+ 4P &# 2 Up 3+ 6- 8 FLUSH BRACKET COLOR1, PANEL SEAL Black B C No Seal One Seal White W Y Gray G H 9 ACTUATOR No Actuator Contura VII ACTUATOR ORENTATION ABOVE TERMINALS 0 Z 3,6 1,4 STANDARD 10 LENS Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator Z - No Lens White Amber Green Red Blue Lens style & location 6 B G M T 7 C H N U 8 D J P V 9 E K R W A F L S Y 1 2 3 4 5 11 ACTUATOR COLOR/THUMB PRINT COLOR1 O H Y C S N/A - No Actuator Grey/Black White/Black Black/Black Red/Black 12 ACTUATOR LENS LEGENDS2,4 11 ON OFF 12 OFF ON 13 | O 14 O | 15 O O FN F 16 O O FN F 17 O | 18 | O 3 2 2 1 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 1 2 3 4 1 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 4 Orientation 4 4 SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 ( ) - momentary 1 Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 0 No lamp Neon 1 125VAC 2 250VAC 4 3V 5 6V 6 12V 7 18V 8 24V Incandescent superbright superbright LED* Red Amber Green Red 2VDC A L F R 6VDC B M G S C N H T 12VDC 24VDC D P J V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 2 2 CIRCUIT 1 B C D E F M N 10 Lens 6,7 LAMP (same coding for both selections) 1 SERIES V Position: 9 Actuator 4 2 Circuit 3 1 Series 2 AA 46 46 3AA-146 AA 3AA-246 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Additional ratings available. See page 20. 4 Legends available for lighted ovel lens version only 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura X, XI & XII Sealed Rocker Switches | 17 V 1 D A B 6 0 1 -- 6 P Z 00 -- 0 00 2 Circuit 4 5 6 Termination Illumination Lamp 3 Rating 7 Lamp 8 Bracket Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 Position: No lamp Neon5 Incandescent LED* ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 2 B (ON) NONE OFF 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 M* (2 & 3, 5 & 6) 2&3 OFF R (2 & 3, 5 & 6) 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING4 .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING 8 W L M N 9 R T P V 12 Legend 13 14 Legend Actuator Orientation Lens Legend #1 &# 2 #1 &# 2 Down Independent Independent Independent 3+ 6+ 8+ 6+ 8777- #1 #2 #1 &# 2 #1 &# 2 Down Up Down Down Up Up 3+ 3+ 3+ 1+ 1+ 3+ 666446- 2VDC 6VDC 12VDC 24VDC 0 1 125VAC 4 3V Red A B C D 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J 7 18V 8 24V superbright Red R S T V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET) X & XI w/Flush Bracket 0 1 2 B C D W Y Z G H J # of gaskets Black White Gray 9 ACTUATOR No Actuator Contura X Contura XI Contura XII 0 Black 1 6 J Actuator orientation above terminals: Gray 2 7 K X, XI, XII w/Raised Bracket 0 1 1 4 2 5 3 6 White 3 8 N Red 4 9 M 3,6 1,4 10 LENS - ABOVE LAMP #1 TERMINALS1,4 11 LENS - ABOVE LAMP #2 TERMINALS3,6 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue 3 8 D J P V 4 9 E K R W 5 A F L S Y Lens Style Bar One piece Square Two piece Square* 2 7 C H N U Two piece Square* 1 6 B G M T (w/ clear top protective lens) (w/ smoke top protective lens) Two piece Square* (w/ white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F F F 21 22 23 24 OFF ON O I 25 O F F 26 O N 27 O 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION3 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation 4 6ZZ3G-100 6FFMA-4MC MA 3G ORIENTATION 1 ORIENTATION 2 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Sealed Unsealed Lamps when Illuminated Terminals S 0 NONE A 1 #1 Independent 8+ 7B 2 #1 Down 3+ 7C 3 #2 Up 3+ 7D 4 #1 Down 3+ 7&# 2 Down 1+ 7E 5 #1 Up 1+ 7&# 2 Up 3+ 7F 6 #1 Independent 8+ 7&# 2 Up 3+ 6G 7 #1 Independent 8+ 7&# 2 Up 3+ 7H Z #2 Independent 8+ 7U Y #1 Independent 8+ 7&# 2 Independent 10+ 9K 11 Lens Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 2 CIRCUIT J 10 Lens 6,7 LAMP (same coding for both selections) 1 SERIES V 1 B C D E F M N 9 Actuator ORIENTATION 4 1 Series 70 G3 A7 MC 6ZZ3G-1A7 MA 6FFMA-3MC MC 6FZ70-100 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators; Custom colors are available, consult factory. 3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2. 4 Additional ratings available. See page 20. 5 Not available with Contura XI rockers. 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 18 | V-Series Contura X Locking Sealed Rocker Switches V 1 D A S W 0 1 -- 1 P B 00 -- 0 1 Series 2 Circuit 4 5 6 Termination Illumination Lock 3 Rating 7 Lamp 8 Bracket 11 Function 12 Legend 13 Legend Orientation Lamp above terminals 3 & 6 end of switch 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 8 terminal 10 terminal 8- -7 8- -7 1- -4 1- -4 2- -5 2- -5 3- -6 3- -6 10 - - 9 No lamp Neon Incandescent LED* ( ) - momentary SP - single pole - uses terminals 1, 2 & 3. DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. Terminals 7, 8, 9 & 10 for lamp circuit only. 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 4 D ON NONE ON 6 J ON OFF ON 9 N OFF NONE ON SPECIAL CIRCUITS H* 2&3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2&3 OFF S 2 & 3, 5 & 6 2&3 1&2 E* 5&6 5&3 5&1 *Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING4 1 B C D E F M N 10 Lens 7 LAMP 1 SERIES V Position: 9 Actuator .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit 6 only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 term Termination 1 2 .250 TAB (QC) no barriers A B .250 TAB (QC) with barriers J K .250 TAB (QC) no barriers 3 4 Solder Lug no barriers C D Solder Lug 5 6 Wire Leads no barriers E F Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens position Sealed Unsealed Lamps when Illuminated S 0 NONE C 3 #2 Up H Z #2 Independent Selections for Double Pole Switches Only: R #2 Up M Lamp wired to Terminals 3+ 8+ 77- 3+ 6- 6 LOCK Lock above terminals 1 & 4 end of switch. W lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Located over T1-4 end of switch. 4 Additional ratings available. See page 20. 2VDC 6VDC 12VDC 24VDC 0 1 125VAC 4 3V Red A B C D 2 250VAC 5 6V 6 12V superbright Amber Green L F M G N H P J 7 18V 8 24V superbright Red R S T V * Consult factory for "daylight bright" LED options. Typical current draw for LED is 20ma. 8 RAISED BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET) Black 1 4 No Gasket One Gasket White 2 5 Gray 3 6 9 HARD SURFACE ACTUATOR Black 1 Contura X Grey 2 Red 3 White 4 Actuator orientation above terminals: 3,6 1,4 10 LENS - ABOVE LAMP #2 TERMINALS3,6 Z - No Lens Clear White Amber Green Red Blue 3 8 D J P V 4 9 E K R W 5 A F L S Y Lens Style Bar One piece Square Two piece Square* 2 7 C H N U Two piece Square* 1 6 B G M T (w/ clear top protective lens) (w/ smoke top protective lens) Two piece Square* (w/ white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR3 Lock Color Match Actuator Black White Red Gray Safety Orange Up A B C D E F Down H J K L M N Up & Down R S T V W Y 12 ACTUATOR LENS OR BODY LEGEND2 00 - No Legend 21 22 OFF ON 25 O F F 26 O N 23 24 O 27 O I 28 I For additional legend options & codes, visit us at www.carlingtech.com. Orientation 1 13 LEGEND ORIENTATION3 0 1 2 3 4 No legend (used with codes 11-18 in selection 12) Orientation 1 Orientation 2 Orientation 3 Orientation Orientation 4 Orientation 2 4 1PM4F-1 45 4F MC 13DMC-1 18K45-2 Orientation 3 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura Sealed Rocker Switch Actuators Separately | 19 Reduce inventory levels and cost by stocking actuators and base switches separately. Contura II, III, IV, V, X, XI, XII Base switches separately: specify V with code selections 2-8 in the ordering schemes. Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes. Panel Seal: VPS Contura II, III, IV, V Actuator only: VV with code A, C, E, G or P for selection 9 & with selections 10-14 in the ordering schemes. Contura X, XI, XII actuators with lenses separately: VV with code selections 9-14 in the ordering schemes. Contura X & XI actuators without lenses separately: VVR 6 1 00 1 1 Actuator Separately 4 Actuator Legend 2 3 Actuator Lens Style/Color Opening 5 Legend Orientation Black 1 6 Contura X Contura XI Gray 2 7 3 LENS OPENING FOR1 1 2 3 4 2 Style & Color 2 ACTUATOR STYLE & COLOR Red 4 9 J Black K Gray 15 O O F N F 16 O O N F F 17 O I Z No lens square lens on top/ bar lens on bottom (Contura X only) 1 Bar lens 00 - No Legend 14 O I ORIENTATION 4 1 TOP OF LENS SEPARATELY VVT I 28 I 1 Clear ORIENTATION OF ACTUATOR/LENS IN PANEL 2 Smoke top lens bottom lens } ORIENTATION 1 ORIENTATION 2 2 Lens Style 4 Legend 3 Lens Color 2 LENS STYLE3 1 Bar lens 3 White 2 One Piece Square lens 5 Legend Orientation 2 White 1 piece lens/bar lens are positioned the same as bottom lens for assembly, minus the top lens. Lenses snap in from bottom. Notes: 1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 must be chosen. 2 Center of actuator marking not available for Contura XII. 3 Legend is not available for bar style lens. 4 Not recommended with neon lamps. 5 Must also order top piece of 2 piece square lens separately. 3 Amber 4 Green4 4 LENS OR BODY LEGEND2 00 - No Legend two piece lens assembly 3 Bottom of Two-Piece Square lens5 3 TRANSLUCENT LENS COLOR 1 Clear 2 COLOR Contura X, XI & XII actuator lens assembly: actuator stem 27 O 24 1 CONTURA X, XI & XII LENS SEPARATELY VVL Contura X, XI & XII top piece of 2-piece lens separately: posts mount toward actuator stem 26 O N O VVL 2 1 00 0 ORIENTATION 2 ORIENTATION 3 2 Color 25 O F F 23 ON Contura X, XI & XII actuator lens assembly separately: ORIENTATION 1 1 Lens Separately 1 Lens Separately 22 6 LEGEND ORIENTATION3 0 No legend 1 Orientation 1 2 Orientation 2 ORIENTATION OF ACTUATOR/LENS IN PANEL 5 LEGEND ORIENTATION1 VVT 1 21 OFF For additional legend options & codes, visit us at www.carlingtech.com. 18 I O No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 M Red 2 Square lens 5, 7 LENS OR BODY LEGEND2 For additional legend options & codes, visit us at www.carlingtech.com. 0 1 2 3 4 6 7 Legend Legend Orientation 5 Legend N White 3,4 LENS OPENING FOR 4 ACTUATOR LENS OR BODY LEGEND 00 - No Legend this location 11 ON 12 OFF 13 I OFF ON O 4 Lens Opening 3 Lens Opening 1 CONTURA XII ACTUATOR SEPARATELY VVP White 3 8 5 One bar lens One bar lenses One square lens two square lens VVP J 1 Z 21 1 00 1 Actuator 1 CONTURA X & XI ACTUATOR SEPARATELY VVP 2 ACTUATOR STYLE & COLOR Contura XII actuators without lenses separately: 21 OFF 22 25 O F F 26 O N ON 23 5 Red O 27 O 24 6 Blue4 I 28 I For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 5 LEGEND ORIENTATION3 0 1 2 3 4 No legend Orientation 1 Orientation 2 Orientation 3 Orientation 4 ORIENTATION 1 ORIENTATION 4 ORIENTATION 2 ORIENTATION 3 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com 20 | V-Series Contura Sealed Rocker Switch Accessories Easily integrate Contura products into your system, with Contura Accessories Q.C. SELECTION GUIDE Contura ConnectorsPART NO COMPANY SERIES WIRE RANGE Q.C. SELECTION TIN GUIDE PLAIN COMPANY SERIES ORIENTATION MM 2 AWG WIRE RANGE PLATED BRASS BRASS PART NO (REF) 12 3.0 ORIENTIN PLAIN TATION 12010601 (2)16-14 02965471 AWG MM 2(2)1.0-2.0 PLATED Q.C. SELECTION Q.C. GUIDE SELECTION Q.C. SELECTION GUIDE GUIDE PACKARD BRASS BRASS 02965470 16-14 (REF) 1.0-2.0 02965580 B 58 SERIES WIRE WIRE WIRE PART NO PART NO RANGE NO RANGE 02965580 12PART 20-18 3.0 02965469 06288318 .5-.8 RANGE COMPANY COMPANY ORIENORIEN02965471 12010601 (2)16-14 (2)1.0-2.0 TIN TIN TIN 10 5.0 2 2 PLAIN SERIES SERIES PLAIN 12084590 PLAIN MMAWG TATIONMM TATION AWG AWG MM 2 PLATED PLATED Q.C.BRASS SELECTION GUIDE BRASS BRASS 02965470 PLATED 16-14 1.0-2.0 B 12052224 3.0 (REF) (REF) BRASS BRASS (REF)12 BRASS WIRE 02965469 06288318 20-18 .5-.8 02965580 02965580 12 029655803.0 16-14 12 3.0 12 3.0 PART NO 12015870 1.0-2.0 COMPANY SERIES PACKARD 58 SERIES RANGE PACKARD 12010601 12010601 12010601 02965471 (2)16-14 (2)16-14 (2)16-14 02965471 02965471 COMPANY ORIEN10(2)1.0-2.0 5.0 (2)1.0-2.0 12084590 Q.C. SELECTION GUIDE 12020035 (2)22-18 (2).5-.8 METRI-PACK TIN PACKARD PACKARD PLAINPACKARD 2 B 1.0-2.0 SERIES TATION 02965470 02965470 16-14 02965470 16-14 AWG MM3.0 PLATED 12 1.0-2.016-14 12052224 630 SERIES 58 SERIES 58 SERIESBRASS 58 SERIES WIRE 12015869 20-18 .5-.8 12015832 (REF) BRASS PART NO20-18 02965469 06288318 02965469 06288318 02965469.5-.8 RANGE 20-18 06288318 .5-.8 20-18 ORIENTATION (2)1.0-2.0 A B1.0-2.0 .5-.8 TANG TANG B 16-14 1.0-2.0 12015870 12 5.0 20-22 PACKARD COMPANY 02965580 ORIEN12052222 .35-.5 10 10 3.0 5.0 10 5.0 12084590 12084590 12084590 TIN TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT PLAIN SERIES 02965471 TATIONA 12020035 METRI-PACK (2)22-18 (2).5-.8 12010601 (2)16-14 (2)1.0-2.0 TANG TANG TANG AWG MM 2 3.0 12052224 12052224 1212052224 3.0 16-12 12 12 3.0 PLATED 1.3-3 BRASS 630 SERIES PACKARD (REF) SYMBOL B 16-14 1.0-2.0 BRASS 60253-2 60253-1 1201583202965470 20-18 .5-.8 12015869 58 SERIES 12015870 12015870 12015870 16-14 1.0-2.016-14 1.0-2.0 16-14 1.0-2.0 AMP PACKARD PACKARD02965469 PACKARD (2) 1.3 20-18 12 (2) 16 .5-.8 3.0 02965580 06288318 250 SERIES (2)22-18 (2)22-18 A(2).5-.8B A 12020035 12020035 METRI-PACK METRI-PACK 12020035 METRI-PACK 12052222(2)22-18 20-22(2).5-.8 .35-.5A (2).5-.8 TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 12010601 (2)1.0-2.0 02965471 10 (2)16-14 5.0 12084590 630 SERIES 630 SERIES 630 SERIES 42100-2 .8-2 FASTIN-FASTON 42100-1 12015869 12015869 12015869 20-18 .5-.818-14 20-18 .5-.8 20-18 .5-.8 TANG 12015832 12015832 12015832 PACKARD 16-12 1.3-3 12 16-14 3.0 1.0-2.0 B 02965470 12052224 SYMBOL 58 SERIES 60253-1 60253-2 20-22 20-22 .35-.5 20-22 12052222 12052222 .35-.522-18 12052222 60295-2 .3-.9 TANG .35-.5 60295-1 AMP SYMBOL = TANG SYMBOL = TANG SYMBOL = IN SLOT SHOWS ORIENTATION SHOWS OF TANG ORIENTATION SHOWS OFORIENTATION TANG IN SLOT OF TANG IN SLOT 12015870 16-14 1.0-2.0 02965469 06288318 20-18 .5-.8 (2) 16 (2) 1.3 PACKARD 250 SERIESMETRI-PACK 16-12 (2)22-18 1.3-3 16-12 16-12 B 1.3-3 (2).5-.85.0 1.3-3 A 12020035 SYMBOL SYMBOL SYMBOL 10 part60253-2 60253-2 60253-2 60253-1 60253-1 AMP Consult AMP Packard AMP 12084590 42100-2 FASTIN-FASTON 42100-1 18-14 .8-2 (2)and NOTE: Delphi and/or Amp on60253-1 actual numbers availability. 630 SERIES (2) 16 (2) 1.3 (2) 16 1.3 (2) 16 (2) 1.3 TANG 12015869 20-18 .5-.8 12015832 12052224 12 3.0 B 250 SERIES SERIES trademark 250 SERIESof B B AMP is 250 a 60295-1 registered AMP Inc. Harrisburg, PA 60295-2 22-18 .3-.9 18-14 .8-2 18-14 .8-218-14 .8-2 42100-2 42100-2 FASTIN-FASTON FASTIN-FASTON 42100-1 FASTIN-FASTON 42100-1 42100-1 20-22 .35-.5 12052222 12015870 1.0-2.0 Electrical Delphi PACKARD Packard is a42100-2 registered trademark of 16-14 Delphi-Packard Systems Warren, TANG SYMBOL = Ohio SHOWS ORIENTATION OF TANG IN SLOT 22-18 .3-.9 22-18 22-18A .3-.9 60295-2 60295-2 60295-2 60295-1 60295-1 12020035 60295-1 16-12 1.3-3(2).5-.8 .3-.9 (2)22-18 METRI-PACK SYMBOL 60253-2 60253-1 NOTE: Consult Delphi Amp on actual part numbers and availability. AMP 630Packard SERIES and/or 12015869 (2) 1620-18 (2) 1.3 .5-.8 12015832 .820[20.83] 250 SERIES NOTE: Consult NOTE: Packard Consult and/or Delphi NOTE: Amp Packard onConsult actualand/or part Delphi numbers Amp Packard on actual and and/or availability. partAmp numbers on actual and part availability. AMP is aDelphi registered trademark of AMP Inc. Harrisburg, PA B numbers and availability. 42100-2 FASTIN-FASTON .35-.5 AMP isPackard a registered trademark is a42100-1 registered of AMP AMP Inc. trademark Harrisburg, is 12052222 a registered AMP PA18-14 trademark Inc.20-22 Harrisburg, of .8-2 AMP PAInc. Harrisburg, Delphi is AMP a.820[20.83] registered trademark of ofDelphi-Packard Electrical SystemsPA Warren, TANG Ohio SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT Delphi Packard is a registered Delphi Packard trademark is Delphi a registered of Delphi-Packard Packard trademark is a22-18 registered Electrical of Delphi-Packard trademark Systems of Electrical Delphi-Packard Ohio SystemsElectrical Warren, Ohio Systems Warren, Ohio .3-.91.3-3Warren, 60295-2 60295-1 16-12 SYMBOL 60253-2 60253-1 AMP (2) 16 and availability. (2) 1.3 NOTE: Consult Delphi Packard and/or Amp on actual part numbers 250 SERIES .820[20.83] .820[20.83] .820[20.83] B .820[20.83] .820[20.83] .820[20.83] .820[20.83] AMP is a registered trademark Inc. Harrisburg, PA 18-14 .8-2 42100-2 FASTIN-FASTON 42100-1 of AMP Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio 22-18 .3-.9 60295-2 60295-1 .820[20.83] NOTE: Consult.820[20.83] Delphi Packard and/or Amp on actual part numbers and availability. AMP is a registered trademark of AMP Inc. Harrisburg, PA Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio .920[23.37] .920[23.37] PACKARD 630 PACKARD 630 VC1 B A B .920[23.37] .920[23.37] A A .820[20.83] A VC1 .920[23.37] PACKARD 630 A .920[23.37] VC1 B B A A PACKARD 630 PACKARD 630 PACKARD 630 VC1 PACKARD 630 B VC1 VC1 VC1 B A A A AMP,58PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD AMP, 58 PACKARD 58 PACKARD AMP, PACKARD 58 PACKARD 630 AMP, PACKARD 630 PACKARD 630 VC1 PACKARD 630 VC1 VC1 VC1 .920[23.37] B B B B .920[23.37] A VC2 PACKARD 630 B A VC1 .820[20.83] .770[19.56] .770[19.56] .920[23.37] .920[23.37] AMP VC2 VC2 AMP AMP, PACKARD 58 AMP, PACKARD 58 AMP VC2 AMP AMP AMP 1.170[29.72] A VC2 VC2 AMP 5 AMPB VC2 PACKARD 630 A VC2 1.170[29.72] A A 1.170[29.72] PACKARD 630 .770[19.56] .950[24.13] A AMP PACKARD 630 58 VC2 AMP, PACKARD 679 43 B A PACKARDB 630 AMP, PACKARD 58 B B .950[24.13] B 10 3 2 1 8 7 4 5 69 10 3 2 VC21 8 7 4 5 69 A A A .950[24.13] .950[24.13] PACKARD 630 A B B PACKARD 630 AMP, 58AMP, PACKARD 58 AMP, PACKARD AMP, PACKARD 58 PACKARD 58 .950[24.13] 1 87 4 4 3 5 23 6 1 2 8 AMP, PACKARD AMP AMP 1.466[37.24] AMP, 1.466[37.24] PACKARD 58 AMP, PACKARD 58 1.250[31.75] 1.250[31.75] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 10 3A 2 1.266[32.16] 1 8 7 458 1.466[37.24] 5 61.466[37.24] 9 10 3 2 1 81.266[32.16] 7 4 5 69 AMP, PACKARD A A4 3 A2 1 8 7 58 5 6 1.266[32.16] 1.266[32.16] 1.466[37.24] AMP, PACKARD 58 1.170[29.72] 1.170[29.72] 1.170[29.72] PACKARD 630 A PACKARD PACKARD 630 630 72 451 5 6 9 .950[24.13] 86 9 3 1.170[29.72] 2 1 8 7 B AMP .770[19.56] .770[19.56] A VC2 10 3 10 2 31 82 10 5 36 972 417845 56 96 10 9 37 4 2 15 8 6 9 10 10 3 .920[23.37] 35 62 9 1 VC28 7 4 1 38 2 71 48 10 32 1 2 87 1410 8 AMP, PACKARD 58 .770[19.56] .770[19.56] .920[23.37] .920[23.37] .920[23.37]VC2 B .820[20.83] 5 B PACKARD 630 B 6 B PACKARD 630 PACKARD 630 AMP, PACKARD 58 7 4 1.250[31.75]AMP, PACKARD 5 6 AMP, PACKARD 58 7 4 5 6 1.250[31.75] 58 630 3 2 1 PACKARD 8 7 4 5 6 PACKARD 630 PACKARD 630 VC1 VC1 VC2 1.250[31.75] 1.266[32.16] 1.466[37.24] 1.466[37.24] MARKING DETAIL1.266[32.16] MARKING MARKING DETAIL DETAIL MARKING BDETAIL MARKING MARKING DETAIL DETAIL MARKING DETAILMARKING MARKING DETAIL DETAIL MARKING DETAIL MARKING MARKING DETAILDETAIL MARKING DETAIL MARKING MARKING DETAIL DETAIL MARKING DETAIL MARKING DETAIL .950[24.13] B MARKING DETAIL FRONT VIEW FRONT VIEW REAR1.466[37.24] VIEW FRONT VIEW REAR VIEW FRONT REAR VIEW VIEW FRONT VIEW REAR FRONT VIEW VIEW REAR VIEW FRONTB REAR VIEW VIEW FRONT VIEW REAR FRONT VIEWVIEW REAR VIEW REAR VIEW B 1.250[31.75] 1.266[32.16] 1.266[32.16] 1.466[37.24] PACKARD 630 MARKING DETAIL MARKING MARKING DETAIL AMP MARKING DETAIL MARKING DETAIL AMP, PACKARD 58 AMP, PACKARD 58 DETAIL AMP AMP, PACKARD 58 AMP, PACKARD 58 MARKING MARKING MARKING MARKING DETAIL MARKING DETAIL 10 3DETAIL 2 1 8 7 REAR 4DETAIL 5 VIEW 69 10 3 DETAIL 2 1 FRONT 8 7 4 DETAIL 5 69 FRONT VIEW VIEW MARKING REAR3 VIEW FRONT VIEW 2 1 8 4 5 6 FRONT VIEWVC1 REAR REAR FRONT REAR7 VIEW VC1 VC1 VIEW VCHVIEW VCH VC2 FRONT VIEW VC2 VC2 VIEW VCH MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL CONNECTOR HOUSING CONNECTOR1.466[37.24] HOUSING 1.250[31.75] 1.266[32.16] 1.466[37.24]CONNECTOR HOUSING 1.266[32.16] CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING VCH VC2 FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW (For AMP terminals (For only) AMP terminals (For only) AMP terminals only) VC1VC1 VC2 VCH CONNECTOR HOUSING DETAIL CONNECTOR MARKING HOUSING FRONT VIEW VC1 CONNECTOR HOUSING VC1 CONNECTOR HOUSING MARKING DETAIL CONNECTOR (For AMP terminals only) FRONT VIEW MARKING DETAIL REAR VIEW MARKING DETAIL HOUSING REAR VIEW (For AMP terminals only) VC2 CONNECTOR HOUSING VC2 CONNECTOR HOUSING (For AMP terminals only) Contura X Boot (P/N VB1-01) CONNECTOR HOUSING FRONT VIEW MARKING DETAIL CONNECTOR HOUSING REAR VIEW VCH CONNECTOR HOUSING Additional V-Series Ratings VCH CONNECTOR HOUSING 1 .4VA @ 28VDC Resistive 4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings 1.050[26.67] 1.050[26.67] 1.050[26.67] 1.050[26.67] 5 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified 6* 15A 125VAC 1/2 HP, 12(2)A 125 VAC T85 VB1-01 VB1-01 VB1-01 7*VB1-01 125VAC 1/2 HP, 12(6)A 2.000[50.80] 2.000[50.80] 1.050[26.67] 2.000[50.80] X15A BOOTCONTURA X BOOT CONTURA X BOOT 125 VAC T85 1.050[26.67] CONTURA CONTURA X BOOT 2.000[50.80] 8* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC T85 1.050[26.67] 9* 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85 VB1-01 BCONTURA 15A 24V 2.000[50.80] X BOOT VB1-01 .757[19.23] .757[19.23] .757[19.23] .757[19.23] CONTURA X BOOT 2.000[50.80] C 20A 18V VB1-01 2.000[50.80] X BOOT D 20A CONTURA 12V E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only) .757[19.23] F 10A 14V, 6A, 14VT (circuit G only) G 20A 6V & V Actuator Removal.757[19.23] Tool H 20A 3V 3.99 [101.35] 3.99 [101.35] 3.99 [101.35] .757[19.23] 3.99 [101.35] L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L VRT M .4VA/20A 12V (combi-contact) VRT VRT ACTUATOR REMOVAL VRT TOOL ACTUATOR REMOVAL .900 [22.86] ACTUATOR REMOVAL ACTUATOR REMOVAL 3.99 [101.35] (combination gold/silver contacts for borderline dry circuit applications) (For flush bracket) .900 [22.86] .900 [22.86] TOOL .900 [22.86] TOOL TOOL (For flush bracket) (For flush bracket) N bracket) .4VA/15A 24V (combi-contact) VRT(For flush ACTUATOR REMOVAL (combination gold/silver contacts for borderline dry circuit applications) TOOL .900 [22.86] TOP TOP INSERT POINTS UNDER ACTUATOR TOP Contura II, III, IV (P/N VRT) (For AMP terminals only) CONNECTOR HOUSING MARKING DETAIL MARKING DETAIL REAR VIEW MARKING DETAIL REAR VIEW TOP INSERT POINTS UNDER INSERT POINTS UNDER INSERT POINTS UNDER HOLD FLUSH ON BRACKET AND PUSH ACTUATOR IN ACTUATOR ACTUATOR HOLD FLUSH ON BRACKET AND PUSH HOLD FLUSH ON BRACKET AND HOLD PUSH FLUSH ON BRACKET AND PUSH TOP IN IN IN TOP TOP TOP INSERT POINTS UNDER ACTUATOR HOLD FLUSH ON BRACKET AND PUSH IN TOP TOP (For flush bracket) 3.99 [101.35] 3.99 [101.35] NOTES Consult factory to determine availability for individual circuits and their HP rating. VRT VRTUL, CSA & VDE certified, require terminations A or B for double pole circuits, & are * Ratings 6 - 9 are ACTUATOR REMOVAL INSERT POINTS UNDER ACTUATOR INSERT POINTS ACTUATOR UNDER not available with REMOVAL illumination .900 [22.86] TOOLcircuits 4, 8, D, J, N, & T or with wire lead or solder lug terminations. .900 [22.86] ACTUATOR HOLD FLUSH ON BRACKET AND PUSH TOOL HOLD FLUSH ON INBRACKET AND PUSH (For bracket) Circuits 1, 4, flush A, D,bracket) H, Mflush & E are not available with rating 6 & 8. Rating 7 & 9 only available with circuits IN (For TOP TOP 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8. Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only. TOP TOP 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com V-Series Contura Sealed Rocker Switch Accessories | 21 Contura Mounting Panels Dimensional Specifications: in. [mm] Contura Hole Plug Dimensional Specifications: in. [mm] 1.450 [36.83] .830 [21.08] TEST CUT HOLE IN ACTUAL MATERIAL VHP CONTURA II,III HOLE PLUG 1.240 [31.50] 1.820 [46.23] .430 [10.92] VHP CONTURA II,III HOLE PLUG VH1 STANDARD HOLE PLUG (No wing serrations) (With VC1 connector attached) 2.000 [50.80] VH2 STANDARD HOLE PLUG (With wing serrations) 1.067 [27.10] (TYP. FOR VH3 & VH4) 1.928 [48.97] VH3 CONTURA IV HOLE PLUG (No wing serrations) VH4 CONTURA IV HOLE PLUG (With wing serrations) DETAIL VIEW VH1,VH3 & VH5 HOLE PLUGS (No wing serrations for ease of removal) 1.020 [25.91] (TYP. FOR VH5 & VH6) VH5 CONTURA V HOLE PLUG (No wing serrations) VH6 CONTURA V HOLE PLUG (With wing serrations) DETAIL VIEW VH2,VH4 & VH6 HOLE PLUGS (With wing serrations) REV_SW_V_0612 60 Johnson Avenue * Plainville, CT 06062-1177 * Phone: (860) 793-9281 * Fax: (860) 793-9231 Email: sales@carlingtech.com * www.carlingtech.com