D Non-Reversing Contactors * YS1N AC Controlled . . . . . . . . . . . D-5 * YS3N DC Controlled . . . . . . . . . . . D-6 Reversing Contactors * YS1R AC Controlled . . . . . . . . . . . D-7 * YS3R DC Controlled . . . . . . . . . . . D-8 Thermal Overload Relay * YS1T-RHA. . . . . . . . . . . . . . . . . . . D-9 Starters............................................. D-11 Accessories ....................................... D-12 Specifications * Contactors and Starters . . . . . . . . D-16 * Overload Relays . . . . . . . . . . . . . . D-24 * Accessories. . . . . . . . . . . . . . . . . . D-28 IEC Contactors Section Selection Guide ..................................... D-3 Dimensions....................................... D-35 Mounting Diagrams ........................ D-43 Wiring Diagrams............................. D-47 Application Tables........................... D-51 www.idec.com/contactor Additional Web Resources * New and updated product information * Downloadable software demos & upgrades * Part configuration tool & cross reference * Online stock check & ordering * IDEC field sales & distributor search * Online literature request * Downloadable manuals & CAD drawings * Manufacturer's suggested retail price list * Product training schedule & locations * Advertising & trade show schedules * Press releases & FAQs www.idec.com/contactor for more information on this product family visit IEC Contactors Selection Guide IDEC YS Series Contactors / Starters IEC Contactors D YS Series: Superior performance and low maintenance Key features include: * Simple, compact, rugged electromechanical devices * Meets IEC, UL, c-UL and other international standards * All Contactors, Thermal Overload Relays, and Auxiliary Contact Blocks bear the CE mark * 35mm or 75mm DIN Rail or direct panel mounting * Bifurcated double bridge auxiliary contacts, the moving contact bridge has an "H" form; suitable for interface with electronic circuit * Advanced design and materials, special silver-alloy long life contacts * Cadmium-free contacts for environmental safety * Bimetallic thermal overload relays * Easy operation and maintenance; Direct and simple motor control * Dual frequency 50/60 Hz coils D-2 www.idec.com IDEC YS Series Contactors are used in switching motor loads. Like all IDEC products, each model is engineered for long life, minimum maintenance, dependable operation, and superior performance. Snap on accessories are available for the IDEC YS series, giving each model the flexibility to meet any application requirement. 1. Auxiliary contact blocks * Top mounting type (2 or 4 poles type) * Side mounting type (2 poles type) 2. Adjustable thermal overloads 3. Surge suppressor modules 4. Mechanical interlock blocks 5. PLC interface modules USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Selection Guide Selection Guide RELAY INTERFACE MODULE (With Surge Suppressor Module) YS9Z-TCU500UH SURGE SUPPRESSOR MODULES The interface module incorporates contacts which are actuated upon energization of the module from low power 24VDC sources such as outputs from sensors and programmable controllers. YS9Z-TU25 for YS1N-9F to -25F YS9Z-TU65 for YS1N-32F to -65F YS9Z-TU125 for YS1N-80F to -125F YS9Z-TU180 for YS1N-150F to -180F YS9Z-TU300 for YS1N-220F to -300F SECOND CONTACTOR For reversing applications YS1R, AC Controlled YS3R, DC Controlled (reversing type) D IEC Contactors CONTACTORS Non-reversing YS1N, AC Controlled YS3N, DC Controlled MECHANICAL INTERLOCK BLOCKS Used for reversing contactors YS9Z-TMI65 for YS1N-9F through 65F YS9Z-TMI125 for YS1N-80F through 300F AUX. CONTACT BLOCKS (2P, top mounting type) YS1A-TAH220F (2NO) YS1A-TAH211F (1NO-1NC) YS1A-TAH202F (2NC) for YS1N-9F to -65F AUX. CONTACT BLOCK (2P, side mounting type) YS1A-TAS211F for YS1N-9F to -65F AUX. CONTACT BLOCKS (4P, top mounting type) YS1A-TAH440F (4NO) YS1A-TAH431F (3NO-1NC) YS1A-TAH422F (2NO-2NC) YS1A-TAH413F (1NO-3NC) YS1A-TAH404F (4NC) for YS1N-9F to -65F www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-3 IEC Contactors YS Series YS Series Contactors Key features of the YS Series include: * Compact size * AC and DC coil, reversing and non-reversing * Weld-resistant silver alloy contacts * No cadium used in contacts * Highly reliable auxiliary contacts use bifurcated double bridge contact form * Direct panel mount with screws or 35mm DIN rail (9F to 65F) * Conforms to IEC standards: EN60947-1, EN60947-4-1, EN-60947-5-1 * Approval standards: UL508 (UL File No. E67770, E184169) IEC Contactors D CE Certified Ordering Information IEC CONTACTORS Specify the maximum AC3 current code for the contactor in place of Specify the coil voltage code for the contactor in place of * * * * . This part number is not indicated on the label of the contactor . . YS1N- F11 **** Completed Part Number of Contactors 1 Product Series YS1N: YS1R: YS3N: YS3R: Non- reversing contactor, AC controlled Reversing contactor, AC controlled Non-reversing contactor, DC controlled Reversing contactor, DC controlled 2 a) Approximate Maximum AC3 Current AC or DC Controlled Contactors 9:9A, 12:12A, 20:20A, 25:25A, 32:32A, 38:38A, 40:40A, 50:50A, 65:65A, 80:80A, 100:100A, 125:125A AC Contactors Only 150:150A, 180:180A, 220:220A, 300:300A 4 Coil Voltage (Rated Voltage and Frequency) A024 : AC24V 50/60Hz A048 : AC48V 50/60Hz A110 : AC110V 50/60Hz A120 : AC120V 50/60Hz A230 : AC230V 50/60Hz A240 : AC240V 50/60Hz A380 : AC380V 50/60Hz A415 : AC415V 50/60Hz A480 : AC480V 50/60Hz A600 : AC600V 50/60Hz D024 : DC 24V D048 : DC 48V D110 : DC 110V D220 : DC 220V M100 : DC 110V M200 : DC 220V AC Contactors (all sizes) DC Contactors (sizes 9-65) DC Contactors (sizes 80-125) (Other Voltages Available, Contact IDEC) b) Type of Contactor F: AC controlled all sizes FG2: DC Controlled, sizes 9-65 FG: DC Controlled, sizes 80-125 3 Auxiliary 01: with 10: with 11: with 22: with Contact Configuration (Built onto conctactor) 1NC, only for contactors sizes 9F-12F 1NO, only for contactors sizes 9F-12F 1NO-1NC, only for contactors sizes 20F-65F 2NO-2NC, only for contactors sizes 80F-300F Notes: 1. Use the above ordering information only when interpreting part numbers. Do not use for developing part numbers. 2. Please see tables on following pages for proper selection. 3. For specifications please see page D-16 through page D-34. D-4 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors YS Series YS1N Non-Reversing AC Contactors D IEC Contactors IEC Contactors, AC Controlled Ie (Amps) kW AC3 Rating EN 60974-4-1 HP Rating per UL508 3 Phase 1 Phase Auxiliary Contacts 3 Phase AC1 AC3 220230V 380400V 500V 660690V 120V 230V 200208V 220240V 440480V 550600V 20 8.5 2.2 4 5.5 5.5 1/3 1 2 2 5 5 Part Number N.O. N.C. 0 1 YS1N-9F01**** 1 0 YS1N-9F10**** 0 1 YS1N-12F01**** 20 11.5 3 5.5 7.5 7.5 3/4 2 3 3 7.5 5 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 30 22 5.5 11 15 15 2 3 7.5 7.5 15 15 1 1 YS1N-25F11**** 50 30 7.5 15 18.5 18.5 2 5 7.5 10 20 20 1 1 YS1N-32F11**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1N-38F11**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1N-40F11**** 80 44 15 22 30 33 3 7.5 10 15 40 40 1 1 YS1N-50F11**** 80 60 18.5 30 37 37 5 10 20 20 50 40 1 1 YS1N-65F11**** 1 0 YS1N-12F10**** 1 1 YS1N-20F11**** 135 85 22 45 55 45 7.5 15 25 25 60 60 2 2 YS1N-80F22**** 150 105 30 55 65 65 - - 30 35 60 75 2 2 YS1N-100F22**** 150 114 37 60 75 75 - - 40 50 100 100 2 2 YS1N-125F22**** 200 138 45 75 90 100 - - 40 50 100 125 2 2 YS1N-150F22**** 240 179 55 95 110 110 - - 50 60 125 125 2 2 YS1N-180F22**** 260 205 65 110 132 132 - - 60 75 150 150 2 2 YS1N-220F22**** 350 300 90 160 160 200 - - 75 100 200 200 2 2 YS1N-300F22**** Codes for Control Circuit AC Voltages 50/60 Hz Volts AC 50/60 Hz Code to replace **** 24 48 120 220 240 380 415 480 A024 A048 A120 A220 A240 A380 A415 A480 Consult an IDEC representative for other coil voltages. For accessories, see page D-12. For specifications, see page D-16 through D-34. For dimensions, see pages D-35. For other application tables, see page D-51. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-5 IEC Contactors YS Series YS3N Non-Reversing DC Contactors IEC Contactors D IEC Contactors, DC Controlled Ie (Amps) KW AC3 Rating EN 60974-4-1 HP Rating per UL508 3 Phase 380400V 1 Phase 500V 660690V 120V Auxiliary Contacts 3 Phase 230V 200208V 220240V 440480V 550600V Part Number AC1 AC3 220230V 20 8.5 2.2 4 5.5 5.5 1/3 1 2 2 5 5 20 11.5 3 5.5 7.5 7.5 3/4 2 3 3 7.5 5 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS3N-20FG211**** 30 22 5.5 11 15 15 2 3 7.5 7.5 15 15 1 1 YS3N-25FG211**** 50 30 7.5 15 18.5 18.5 2 5 7.5 10 20 20 1 1 YS3N-32FG211**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS3N-38FG211**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS3N-40FG211**** 80 44 15 22 30 33 3 7.5 10 15 40 40 1 1 YS3N-50FG211**** N.O. N.C. 0 1 YS3N-9FG201**** 1 0 YS3N-9FG210**** 0 1 YS3N-12FG201**** 1 0 YS3N-12FG210**** 80 60 18.5 30 37 37 5 10 20 20 50 40 1 1 YS3N-65FG211**** 135 85 22 45 55 45 7.5 15 25 25 60 60 2 2 YS3N-80FG22**** 150 105 30 55 65 65 - - 30 35 60 75 2 2 YS3N-100FG22**** 150 114 37 60 75 75 - - 40 50 100 100 2 2 YS3N-125FG22**** Codes for 80F/100F/125F Codes for Control Circuit DC Voltages, 9F through 65F Volts DC Code to replace **** 24 48 110 220 110 220 D024 D048 D110 D220 M100 M200 Consult an IDEC representative for other coil voltages. For accessories, see page D-12. For specifications, see pages D-16 through D-34. For dimensions, see page D-35. For other application tables, see page D-51. D-6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors YS Series YS1R Reversing AC Contactors D IEC Contactors, AC Controlled kW AC3 Rating EN 60974-4-1 HP Rating per UL508 3 Phase 1 Phase Auxiliary Contacts 3 Phase AC1 AC3 220230V 380400V 500V 660690V 120V 230V 200208V 220240V 440480V 550600V 20 8.5 2.2 4 5.5 5.5 1/3 1 2 2 5 5 IEC Contactors Ie (Amps) Part Number N.O. N.C. 0 1 YS1R-9F01**** 1 0 YS1R-9F10**** 0 1 YS1R-12F01**** 20 11.5 3 5.5 7.5 7.5 3/4 2 3 3 7.5 5 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 30 22 5.5 11 15 15 2 3 7.5 7.5 15 15 1 1 YS1R-25F11**** 50 30 7.5 15 18.5 18.5 2 5 7.5 10 20 20 1 1 YS1R-32F11**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1R-38F11**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1R-40F11**** 80 44 15 22 30 33 3 7.5 10 15 40 40 1 1 YS1R-50F11**** 80 60 18.5 30 37 37 5 10 20 20 50 40 1 1 YS1R-65F11**** 1 0 YS1R-12F10**** 1 1 YS1R-20F11**** 135 85 22 45 55 45 7.5 15 25 25 60 60 2 2 YS1R-80F22**** 150 105 30 55 65 65 - - 30 35 60 75 2 2 YS1R-100F22**** 150 114 37 60 75 75 - - 40 50 100 100 2 2 YS1R-125F22**** 200 138 45 75 90 100 - - 40 50 100 125 2 2 YS1R-150F22**** 240 179 55 95 110 110 - - 50 60 125 125 2 2 YS1R-180F22**** 260 205 65 110 132 132 - - 60 75 150 150 2 2 YS1R-220F22**** 350 300 90 160 160 200 - - 75 100 200 200 2 2 YS1R-300F22**** Codes for Control Circuit AC Voltages 50/60 Hz Volts AC 50/60 Hz Code to replace **** 24 48 120 220 240 380 415 480 A024 A048 A120 A220 A240 A380 A415 A480 Consult an IDEC representative for other coil voltages. For accessories, see page D-12. For specifications, see page D-16 through D-34. For dimensions, see pages D-35. For other application tables, see page D-51 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-7 IEC Contactors YS Series YS3R Reversing DC Contactors IEC Contactors D IEC Contactors, DC Controlled Ie (Amps) kW AC3 Rating EN 60974-4-1 HP Rating per UL508 3 Phase 1 Phase Auxiliary Contacts 3 Phase AC1 AC3 220230V 380400V 500V 660690V 120V 230V 200208V 220240V 440480V 550600V 20 8.5 2.2 4 5.5 5.5 1/3 1 2 2 5 5 Part Number N.O. N.C. 0 1 YS3R-9FG201**** 1 0 YS3R-9FG210**** 0 1 YS3R-12FG201**** 20 11.5 3 5.5 7.5 7.5 3/4 2 3 3 7.5 5 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 30 22 5.5 11 15 15 2 3 7.5 7.5 15 15 1 1 YS3R-25FG211**** 50 30 7.5 15 18.5 18.5 2 5 7.5 10 20 20 1 1 YS3R-32FG211**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS3R-38FG211**** 60 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS3R-40FG211**** 80 44 15 22 30 33 3 7.5 10 15 40 40 1 1 YS3R-50FG211**** 80 60 18.5 30 37 37 5 10 20 20 50 40 1 1 YS3R-65FG211**** 1 0 YS3R-12FG210**** 1 1 YS3R-20FG211**** 135 85 22 45 55 45 7.5 15 25 25 60 60 2 2 YS3R-80FG22**** 150 105 30 55 65 65 - - 30 35 60 75 2 2 YS3R-100FG22**** 150 114 37 60 75 75 - - 40 50 100 100 2 2 YS3R-125FG22**** Codes for Control Circuit DC Voltages, 9F through 65F Volts DC Code to replace **** Codes for 80F/100F/125F 24 48 110 220 110 220 D024 D048 D110 D220 M100 M200 Consult an IDEC representative for other coil voltages. For accessories, see page D-12. For specifications, see page D-16 through D-34. For dimensions, see pages D-35. For other application tables, see page D-51 D-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors YS Series Thermal Overload Relays YS1T-RHA thermal overload relays are designed to meet the heating characteristics of induction motors with insulation class type E. Various functions can be selected by using the reset button and adjustment button on top of the thermal overload relay. Key features of the YS1T Series include: * Single-phase protection * Bi-metallic * Compact and sturdy * Ambient temperature compensation mechanism * Manual/automatic reset operation * 3 element type with phase failure protection * Conforms to IEC Standards EN60947-1, EN60947-4-1, EN60947-5-1 * Approval standards UL508, UL File No. E158813 D IEC Contactors Ordering Information THERMAL OVERLOAD RELAYS *Part number is indicated on the label of the thermal overload relay. Y S 1 T- R H A Completed Part Number of Thermal Overload Relay 1 Product Series 2 Applicable Maximum Motor Current 25F: 25A, contactor sizes 9F,12F, 20F, 25F 38F: 40A, contactor sizes 32F, 38F 65F: 65A, contactor sizes 40F, 50F, 65F 125F: 125A, contactor sizes 80F, 100F, 125F 150F: 150A, contactor sizes 150F or 180F 180F: 180A, contactor sizes 150F or 180F *300F: 300A, contactor size 220F or 300F *400F: 400A, contactor size 220F or 300F Note: *With Current Transformer (CT) 4 Function D: 3-element Type with Phase Failure Protection D 3 Current setting range code P13 P20 P30 P50 P80 1P3 1P5 2P0 3P0 5P0 7P0 8P5 11P 15P 21P 27P 32P 35P : : : : : : : : : : : : : : : : : : Adjustable current range 0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.25 - 2 1.6 - 2.5 2.5 - 4 4-6 5.5 - 8 7 - 10 9 - 13 12 - 18 17 - 25 23 - 32 28 - 36 30 - 40 Current setting range code 43P 56P 68P 80P 105 120* 135 155 160* 180* 240* : : : : : : : : : : : Adjustable current range 37 - 50 48 - 65 55 - 80 65 - 95 85 - 125 96 - 155 110 - 160 125 - 185 128 - 200 150 - 240 192 - 300 Note :*With CT Verify appropriate current setting range code with the correct size overload using the complete part list on the following page. Notes: 1. Use the above ordering information only when interpreting part numbers. Do not use for developing part numbers. 2. For applicable combinations of contactors and thermal overload relays, please consult following page. 3. For specifications and settings please see pages D-16 through D-34. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-9 IEC Contactors YS Series Thermal Overload Relays Product Series YS1T-RHA25F YS1T-RHA38F IEC Contactors D YS1T-RHA65F YS1T-RHA125F YS1T-RHA150F YS1T-RHA180F *YS1T-RHA300F *YS1T-RHA400F *with current transformer D-10 www.idec.com Current Range Range Code 0.1-0.16A P13 YS1T-RHA25FP13D Part Number for Overload 0.16-0.25A P20 YS1T-RHA25FP20D 0.25-0.4A P30 YS1T-RHA25FP30D 0.40-0.63A P50 YS1T-RHA25FP50D 0.63-1.0A P80 YS1T-RHA25FP80D 1.0-1.6A 1P3 YS1T-RHA25F1P3D 1.25-2.0A 1P5 YS1T-RHA25F1P5D 1.6-2.5A 2P0 YS1T-RHA25F2P0D 2.5-4.0A 3P0 YS1T-RHA25F3P0D 4.0-6.0A 5P0 YS1T-RHA25F5P0D 5.5-8.0A 7P0 YS1T-RHA25F7P0D 7.0-10.0A 8P5 YS1T-RHA25F8P5D 9.0-13.0A 11P YS1T-RHA25F11PD 12.0-18.0A 15P YS1T-RHA25F15PD 17.0-25.0 21P YS1T-RHA25F21PD 9-13A 11P YS1T-RHA38F11PD 12-18A 15P YS1T-RHA38F15PD 17-25A 21P YS1T-RHA38F21PD 23-32A 27P YS1T-RHA38F27PD 28-36A 32P YS1T-RHA38F32PD 30-40A 35P YS1T-RHA38F35PD 12-18A 15P YS1T-RHA65F15PD 17-25A 21P YS1T-RHA65F21PD 23-32A 27P YS1T-RHA65F27PD 28-36A 32P YS1T-RHA65F32PD 30-40A 35P YS1T-RHA65F35PD 37-50A 43P YS1T-RHA65F43PD 48-65A 56P YS1T-RHA65F56PD 37-50A 43P YS1T-RHA125F43PD 48-65A 56P YS1T-RHA125F56PD 55-80A 68P YS1T-RHA125F68PD 65-95A 80P YS1T-RHA125F80PD 85-125A 105 YS1T-RHA125F105D 65-95A 80P YS1T-RHA150F80PD 85-125A 105 YS1T-RHA150F105D 105-160A 135 YS1T-RHA150F135D 85-125A 105 YS1T-RHA180F105D 105-160A 135 YS1T-RHA180F135D 125-185A 155 YS1T-RHA180F155D 96-150A 120 YS1T-RHA300F120D 150-240A 180 YS1T-RHA300F180D 128-200A 160 YS1T-RHA400F160D 200-300A 240 YS1T-RHA400F240D Applicable Contactor Size YS-9F YS-12F YS-20F YS-25F YS-32F YS-38F YS-40F YS-50F YS-65F YS-80F YS-100F YS-125F YS-150F YS-180F YS-150F YS-180F YS-220F YS-300F USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors YS Series YS Series Starters Ordering Instructions for an Assembled Starter STARTERS (Contactors with Thermal Overload Relay) * Select the appropriate contactor (AC or DC, reversing or non-reversing) from pages D-5 through D-8. * Select the correct size overload from page D-9 throught D-10. * The complete assembled part number is the same as the contactor with the following changes: (See examples below) YS2R - FD 11 **** T### D Completed Part Number of Reversing Starter YS1N YS1R YS3N YS3R contactor contactor contactor contactor ----> ----> ----> ----> YS2N YS2R YS4N YS4R IEC Contactors 1 Product Series AC non-reversing Starter AC reversing Starter DC non-reversing Starter DC reversing Starter 2 Maximum AC3 Current (replaced exactly from contactor P/N) F: FG2: FG: is replaced by size, 9-300 for AC controlled is replaced by size, 9-65 for DC controlled is replaced by size, 80-125 for DC controlled 3 Thermal Overload Relay D: 3-element Type with Phase Failure Protection 4 Auxiliary Contact Configuration (Replaced exactly from contactor P/N) 01: with 10: with 11: with 22: with 1NC, for contactor sizes 9F-12F 1NO, for contactor sizes 9F-12F 1NO-1NC, for contactor sizes 20F-65F 2NO-2NC, for contactor sizes 80F-300F 5 Coil Voltage (Replaced exactly from contactor P/N) 6 Thermal Overload Relay, Type YS1T-RHA T: Thermal Overload Relay + ###: Three character code designating of Current Setting Range Code (See page D-10.) EXAMPLE #1 : Contactor : Y S 1 R - 9 F 1 0 A 1 2 0 1 2 4 + Overload: Y S 1 T- R H A 2 5 F 5 P 0 D 6 5 STARTER: Y S 2 R - 9 F D 1 0 A 1 2 0 T 5 P 0 1 2 3 4 5 6 EXAMPLE #2 : Contactor : Y S 3 N - 6 5 F G 2 1 1 D 0 2 4 1 2 4 + Overload: Y S 1 T- R H A 6 5 F 4 3 P D 6 5 STARTER: Y S 4 N - 6 5 F G 2 D 1 1 D 0 2 4 T 4 3 P 1 www.idec.com 2 3 4 5 6 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-11 IEC Contactors Accessories Accessories Accessory Auxiliary Contact Blocks Description Number of Poles Mounting Style Side 2 Poles Top IEC Contactors D 4 Poles Replacement Auxiliary Contact Block Power Wire Kits Mechanical Interlock Marking Tags Overload DIN Rail Bracket 2 Poles Part Number Notes Contact Configuration Side NO NC 1 1 YS1A-TAS211F 0 2 YS1A-TAH202F 1 1 YS1A-TAH211F 2 0 YS1A-TAH220F 0 4 YS1A-TAH404F 1 3 YS1A-TAH413F 2 2 YS1A-TAH422F 3 1 YS1A-TAH431F 4 0 YS1A-TAH440F 1 1 YS1A-TAS211FL For use with YS-9F through YS-12F YS9Z-KIF411344-A For use with YS-20F through YS-25F YS9Z-KIF411345-A For use with YS-32F through YS-38F YS9Z-KIF411346-A For use with YS-40F through YS-65F YS9Z-KIF411347-A For use with YS-80F through YS-125F YS9Z-KIF411348-A For use with YS-150F YS9Z-KIF411588-A For use with YS-180F YS9Z-KIF411588-B For use with YS-220F through YS-300F YS9Z-KIF411590-A For use with YS-9F through YS-65F YS9Z-TMI65 For use with YS-80F through YS-300F YS9Z-TMI125 For use with YS-9F through YS-65F YS9Z-TIP66 For use with YS1T-RHA65F overload YS9Z-TIB65F Auxiliary contacts only available for contactors from 9F through 65F. Replacements for attached auxiliary contact blocks on contactors 80F through 300F Assembled Pushbutton for Overload Reset w/ Extension Rod Blank Cap / No engraving HW1B-M1RS-*T Cap engraved with "R" HW1B-M1RS-*T-ENG-R Cap engraved with "RESET" HW1B-M1RS-*T-ENG-RESET Sub Assembled Operator D-12 HW1B-M0 Blank Cap / No engraving HW1A-B1-* Rod (10 inch length; adjustable) HW9Z-RS-TK2141 www.idec.com * Choose cap color B= Black Y= Yellow N= Gray G= Green S= Blue R= Red W=White USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Accessories Accessories, continued Accessory Surge Suppressor Description Type Part Number RC Circuit Varistor 50-127V AC YS9Z-TU*C120 110-240V AC YS9Z-TU*C240 50-127V AC YS9Z-TU*V120 110-240V AC YS9Z-TU*V240 380-440V AC YS9Z-TU*V440 Relay Interface Module Isolates the coil of contactor from PLC output by providing an easy to mount module that takes 24V DC input and switches up to 380V AC for contactor coils. External source required for contactor coil. Input Voltage 100V AC to 240V AC 50/60 Hz YS9Z-TCU500UH* 25 = YS-9F to YS-25F 65 = YS-32F to YS-65F 125 = YS-80F to YS-125F 180 = YS-150F to YS-180F 300 = YS-220F to YS-300F 12 = YS-9F to YS-12F 25 = YS-20F- to YS-25F 38 = YS-32F to YS-38F 65 = YS-40F to YS-65F 125 = YS-80F to YS-125F 180 = YS-150F to YS-180F 300 = YS-220F to YS-300F D IEC Contactors Star (Wye) Delta Timer * Applicable Size Codes Rated Voltage Contact Style Star: Delayed SPST-NO Delta: Delayed SPST-NO 8-pin GT3S-1AF20 11-pin GT3S-1EAF20 Star: Delayed SPST-NO Delta: Delayed SPST-NO Instantaneous SPST-NO 8-pin GT3S-2AF20 11-pin GT3S-2EAF20 See Section G for further information AC Coils for AC Contactors Replacement Coils For use with YS-9F through YS-12F YS9Z-KIL70461-* For use with YS-20F through YS-25F YS9Z-KIL70462-* For use with YS-32F to YS-38F YS9Z-KIL70463-* For use with YS-40F to YS-65F YS9Z-KIL70464-* For use with YS-80F to YS-125F YS9Z-KIL70518-* For use with YS-150F to YS-180F YS9Z-KIL70466-* For use with YS-220F to YS-300F YS9Z-KIL70467-* A024 = 24V AC 50/60 Hz A048 = 48V AC 50/60 Hz A120 = 120V AC 50/60 Hz A240 = 240V AC 50/60 Hz A380 = 380V AC 50/60 Hz A480 = 480V AC 50/60 Hz A600 = 600V AC 50/60 Hz DC Coils for DC Contactors 9F through 65F For use with YS-9F through YS-25F YS9Z-KIL70562-* For use with YS-32F through YS-38F YS9Z-KIL70564-* For use with YS-40F through YS-65F YS9Z-KI411880-* DC Coils for DC Contactors 80F through 125F For use with YS-80F through YS-125F # YS9Z-KIL70519-* AC/DC Module for 80F through 125F DC coils only 100V AC/DC Module for YS-80F through YS-125F YS9Z-KIFCA840546A 200V AC/DC Module for YS-80F through YS-125F YS9Z-KIFCA840546B D024 = 24V DC D048 = 48V DC D110 = 110V DC D220 = 220V DC D110 = 110V DC D220 = 220V DC Used in conjunction with YS9Z-KIL-70519-* for DC coils 80F through 125F only. # -- YS9Z-KIL70519* is available ONLY in 110V (D110) or 220V (D220) models. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-13 IEC Contactors Accessories Accessories, continued Accessory Description Part Number each part number is for ONE (1) main contact Stationary Main Contacts IEC Contactors D 6 pieces required per contactor For use with YS-20F YS9Z-KIF409056-A For use with YS-25F YS9Z-KIF409057-A For use with YS-32F YS9Z-KIF410179-A For use with YS-38F YS9Z-KIF410180-A For use with YS-40F YS9Z-KIF409083-A For use with YS-50F YS9Z-KIF409083-B For use with YS-65F YS9Z-KIF409083-C For use with YS-80F YS9Z-KIF410697-A For use with YS-100F YS9Z-KIF410697-B For use with YS-125F YS9Z-KIF410697-C For use with YS-150F YS9Z-KIF410853-A For use with YS-180F YS9Z-KIF410854-A For use with YS-220F YS9Z-KIF411841-A For use with YS-300F YS9Z-KIF411842-A Moving Main Contacts 3 pieces required per contactor For use with YS-20F YS9Z-KIF409059-A For use with YS-25F YS9Z-KIF409060-A For use with YS-32F YS9Z-KIF410167-A For use with YS-38F YS9Z-KIF410168-A For use with YS-40F YS9Z-KIF409155-A For use with YS-50F YS9Z-KIF409155-B For use with YS-65F YS9Z-KIF409155-C For use with YS-80F YS9Z-KIF410698-A For use with YS-100F YS9Z-KIF410698-B For use with YS-125F YS9Z-KIF410698-C For use with YS-150F YS9Z-KIF410856-A For use with YS-180F YS9Z-KIF410857-A For use with YS-220F YS9Z-KIF411843-A For use with YS-300F YS9Z-KIF411844-A All part numbers refer to one piece quantity (not sets). D-14 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Accessories Accessories, continued Part Number Description For Use With 35mm Aluminum DIN Rail 7.5 mm deep 1 meter long YS1N-9F through YS1N-38F Contactors 35mm Aluminum DIN Rail 10.5 mm deep. 1 meter long YS1N-9F through YS1N-38F Contactors Plastic replacement markers sold in 100 piece packs YS-9F through YS-65F series contactors, overloads relays and top mount auxiliary contact blocks. DIN Rail End Stop used to prevent contactors from sliding on DIN rails YS1N-32F/YS1N-38F & YS1R reversing contactors DIN Rail End Stop used to prevent contactors from sliding on DIN rails YS1N-9F YS1N-12F YS1N-20F YS1N-25F Contactors 8-pin DIN mount Finger-safe (IP20) screw terminal socket GT3S-1AF20 timer (8 pin) GT3S-2AF20 timer (8 pin) 8-pin DIN mount screw terminal socket open terminal construction GT3S-1AF20 timer (8 pin) GT3S-2AF20 timer (8 pin) 11-pin DIN mount finger-safe (IP20) screw terminal socket GT3S-1EAF20 timer (11pin) GT3S-2EAF20 timer (11pin) 11-pin DIN mount screw terminal socket open terminal construction GT3S-1EAF20 (11 pin) GT3S-2EAF20 (11 pin) BAA1000 BNDN1000 D IEC Contactors YS9Z-TIP66 Markers BNL8 BNL5 SR2P-05C SR2P-06 SR3P-05C SR3P-06 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-15 IEC Contactors Specifications Specifications Contactor Circuit Supply: AC Characteristics Part Number YS1N- Rated Insulation Voltage V 9F 12F 20F 25F 32F 38F 40F 50F 65F 80F 690 690 690 1000 1000 1000 1000 1000 1000 1000 Conformity to Standards 1000 1000 1000 1000 1000 80F 100F 125F 150F 180F 220F 300F UL, c-UL Degree of Protection IEC Contactors 1000 180F 220F 300F NFC 63-110; VDE 0660; BS 5424; JEM 1038; EN60947-1, 60947-4-1; UL508 Approvals D 100F 125F 150F Finger-safe (according to VDE 0106) Dry Ambient Air Temp. for Storage 1/4C -40 to +80 Dry Ambient Air Temp. for Operation 1/4C -10 to +55 (0.85 to 1.1 Un) m 2000 Operating Altitude Operating Position (without derating 301/4 compared with the normal vertical mounting plane (see table on D-22) Main Power Pole Utilization Characteristics: Number of Poles: 3 Part No. 9F 12F 20F 25F 32F 38F 40F 50F 65F in AC3 A 9 12 18 25 30 40 40 50 65 80 105 125 150 180 220 300 in AC1 A 20 20 30 30 50 60 60 80 80 135 150 150 200 240 260 350 Rated Operational Voltage V 660 660 690 690 690 690 690 690 690 690 690 690 690 690 690 690 Maximum Thermal Ith Current (55C) A 20 20 35 35 50 60 60 80 80 135 150 150 200 240 260 350 Making Capacity A 150 150 280 300 480 480 800 800 800 1500 1500 1500 1800 2100 2500 3500 Breaking Capacity 220-380415-440V A 120 150 250 300 380 480 500 600 700 800 1100 1300 1500 1800 2100 3000 I rms 500V A 100 120 200 250 300 400 400 500 550 800 1000 1100 1200 1600 1900 2200 According to EN 60158-1 660-690V A 90 100 120 180 250 350 350 400 430 500 750 820 1100 1200 1400 1800 Rated Operational Current I rms Wiring, minimum-maximum wire size: Stranded Wire (without ferrule) mm2 1-4 1-4 1.5-10 1.5-10 4-16 4-16 5-25 5-25 5-25 8-60 8-60 8-60 8-100 8-100 16-8 16-8 12-6 12-6 10-3 10-3 10-3 8-0 8-0 8-0 8-4/0 8-4/0 1.5-6 1.5-6 4-8 4-8 5-16 5-16 5-16 8-35 8-35 8-35 8-50 8-50 14-80 14-80 18-10 18-10 16-10 16-10 12-8 12-8 10-5 10-5 10-5 8-2 8-2 8-2 8-1 8-1 4-3/0 4-3/0 1.5-6 1.5-6 4-10 4-10 5-25 5-25 5-25 _ _ _ _ _ _ _ 18-10 18-10 16-10 16-10 12-8 12-8 10-3 10-3 10-3 1.5-6 1.5-6 4-10 4-10 5-16 5-16 5-16 _ _ _ _ _ _ _ 18-10 18-10 16-10 16-10 12-8 12-8 10-5 10-5 10-5 1 Conductor AWG mm2 18-10 18-10 1-4 1-4 14-150 14-150 44300mcm 300mcm 2 Conductors AWG Solid Wire (without ferrule) mm2 1-4 1-4 1 Conductor AWG mm2 1-4 1-4 2 Conductors AWG D-16 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Control Circuit Characteristics: Part Number YS1N- Rated AC Control Voltage (50 or 60 Hz) : Un 9F 12F 20F 25F 32F 38F 40F 50F 65F 80F V Un: 24 to 600 Operating Limits Un 85% to 110% x Un Drop-Out Voltage Un 30% to 70% x Un 100F 125F 150F 180F 220F 300F Coil Limits ( 55C) Coil Power Consumption (20C) in Un Inrush VA Cos O (power factor) 55 85 85 150 150 170 170 170 276 276 276 819 819 805 805 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.2 0.2 8 8 8 8 15 15 16 16 16 40 40 40 53 53 100 100 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 50 50 80 80 130 130 150 150 150 231 231 231 714 714 700 700 0.7 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.21 0.21 AC 50 Hz Sealed VA Cos O (power factor) Inrush VA Cos O (power factor) AC 60 Hz Sealed VA 6 6 6 6 12 12 13 13 13 29 29 29 38 38 88 88 Cos O (power factor) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 Coil Power Consumption 50 Hz W 1.5 to 2.5 1.5 to 2.5 1.5 to 2.5 1.5 to 2.5 3.5 to 5.0 3.5 to 5.0 3.7 to 5.2 3.7 to 5.2 3.7 to 5.2 7.5 to 11 7.5 to 11 12 to 16 12 to 16 19 to 27 19 to 27 60 Hz W 1.0 to 2.0 1.0 to 2.0 1.0 to 2.0 1.0 to 2.0 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 6.0 to 8.5 6.0 to 8.5 6.0 to 8.5 9.0 to 13 9.0 to 13 16 to 23 16 to 23 Mechanical Life at Rated Control Voltage (Un) (x 106 operating cycles) Switching Frequency 10 10 10 10 9000 9000 9000 9000 9000 9000 9000 9000 9000 7200 7200 7200 7200 7200 5000 5000 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 mm2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 Mechanical 5 5 5 5 5 5 5 7.5 to 11 5 5 5 5 5 ops/h Electrical AC3 Minimum-Maximum Wire Size 1 Conductor Stranded Wire (without ferrule) mm 2 Conductors 1 Conductor Solid Wire (without ferrule) mm 2 Conductors www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-17 D IEC Contactors 55 IEC Contactors Specifications Coil Resistance: Resistance () YS1N-150F/180F YS1N-220F/300F 0.39 0.298 0.107 6.3 1.85 1.182 0.378 36.6 39.1 8.67 6.46 2.630 122 44.2 45.2 11.6 7.1 3.186 619.5 385 134 137.4 33.3 23.2 8.310 220V 50/60Hz 748.0 397 153 139.0 35.6 24.8 8.840 230V 50/60Hz 776.0 486 153 162.0 37.2 30 9.340 D 240V 50/60Hz 841.8 513 164 177.8 45.6 31.4 9.810 380V 50/60Hz 2577.0 1310 458 426.0 112 82 22.38 IEC Contactors Coil Voltage YS1N-9F/12F YS1N-20F/25F YS1N-32F/38F YS1N-40F/50F/65F YS1N-80F/100F/125F 24V 50/60Hz 7.90 4.8 1.68 1.7 48V 50/60Hz 33.9 19.1 7.1 110V 50/60Hz 174.4 101 120V 50/60Hz 196.3 208V 50/60Hz 415V 50/60Hz 2821.1 1480 501 562.5 133 96.6 28.70 480V 50/60Hz 3166.4 2050 675 757.1 182 129.2 62.71 500V 50/60Hz 3272.7 2170 790 794.0 191 135.2 66.52 600V 50/60Hz 5136.3 3100 1162 1046.7 275 206 100.3 Operating Time: Contactor Frame Size Basic Part Number 50Hz Closing (msec) 60Hz Opening (msec) Closing (msec) Opening (msec) Main Aux. (NO) Aux. (NC) Main Aux. (NO) Aux. (NC) Main Aux. (NO) Aux. (NC) Main Aux. (NO) Aux. (NC) 12 YS1N-9F YS1N-12F 11 to 17 11 to 17 8 to 12 5 to 13 5 to 13 7 to 14 10 to 15 10 to 15 7 to 12 5 to 13 6 to 14 7 to 15 25 YS1N-20F YS1N-25F 14 to 22 15 to 22 9 to 16 3 to 13 6 to 13 9 to 17 13 to 20 13 to 20 9 to 13 2 to 12 7 to 13 9 to 17 38 YS1N-32F YS1N-38F 15 to 23 15 to 23 8 to 16 6 to 15 7 to 15 12 to 23 16 to 24 16 to 24 9 to 16 5 to 14 7 to 15 11 to 21 65 YS1N-40F YS1N-50F YS1N-65F 14 to 22 16 to 24 10 to 16 6 to 17 5 to 17 11 to 23 15 to 22 15 to 22 9 to 16 7 to 16 7 to 16 11 to 20 125 YS1N-80F YS1N-100F YS1N-125F 10 to 27 10 to 26 6 to 19 6 to 20 6 to 20 10 to 26 13 to 31 12 to 30 8 to 22 6 to 18 6 to 18 10 to 24 180 YS1N-150F YS1N-180F 17 to 34 16 to 31 13 to 31 8 to 25 8 to 28 12 to 29 21 to 39 20 to 36 13 to 29 5 to 22 7 to 22 11 to 29 300 YS1N-220F YS1N-300F 17 to 36 16 to 36 13 to 33 8 to 27 8 to 30 12 to 31 22 to 41 21 to 38 13 to 31 5 to 24 7 to 24 11 to 31 Notes: 1. The operating time depends on the type of contactor electromagnet and its control mode. 2. The closing time is measured from the time the coil power supply is switched on to the time the main contacts first make contact. 3. The opening time is measured from the time the coil power supply is switched off to the time the main contacts separate. 4. The duration of the arcing time depends on the type of circuit switched by the poles. 5. For normal three-phase applications the duration of the arcing time is normally less than 10 ms. 6. The load is isolated from the coil power supply after a time equal to: the sum of the opening time and the arcing time. D-18 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Contactor Circuit Supply: DC Operating Coil Characteristics Part Number YS3N-9FG2 YS3N-12FG2 YS3N-20FG2 YS3N-25FG2 YS3N-32FG2 YS3N-38FG2 YS3N-80FG2 YS3N-100FG2 YS3N-125FG2 Exciting Current (mA) Pick-Up Voltage (V) Drop-Out Voltage (V) Coil Resistance (1/2) Power Consumption (W) 24V DC 214 to 262 10 to 15 5 to 10 102 5.1 to 6.4 48V DC 108 to 132 21 to 30 10 to 20 404 5.1 to 6.4 100V DC 51 to 64 45 to 63 21 to 40 1750 5.0 to 6.5 200V DC 26 to 33 90 to 125 43 to 80 6870 5.1 to 6.8 24V DC 214 to 262 10 to 15 5 to 10 102 5.1 to 6.4 48V DC 108 to 132 21 to 30 10 to 20 404 5.1 to 6.4 100V DC 51 to 64 45 to 63 21 to 40 1750 5.0 to 6.5 200V DC 26 to 33 90 to 125 43 to 80 6870 5.1 to 6.8 24V DC 335 to 410 11 to 16 4 to 8 65.1 8.0 to 9.9 48V DC 165 to 202 23 to 32 8 to 16 264 7.8 to 9.8 100V DC 76 to 94 48 to 66 18 to 32 1190 7.5 to 9.5 200V DC 36 to 45 96 to 132 36 to 64 4970 7.0 to 9.1 24V DC 516 to 630 13 to 17 4 to 7 42.3 12.3 to 15.2 48V DC 215 to 263 27 to 33 8 to 13 203 10.3 to 12.7 100V DC 103 to 127 58 to 69 17 to 27 880 10.2 to 12.8 200V DC 53 to 66 116 to 137 35 to 53 3390 10.4 to 13.3 100V DC 19 to 24 76 to 84 43 to 54 -- -- 200V DC 11 to 15 133 to 144 86 to 98 -- -- D IEC Contactors YS3N-40FG2 YS3N-50FG2 YS3N-65FG2 Coil Voltage (V) Standard Operating Time Coil Applied Voltage 100%Uc Part Number Closing Time (ms) Opening Time (ms) Main Aux. (NO) Aux. (NC) Main Aux. (NO) Aux. (NC) YS3N-9F 1NO 38 to 45 38 to 45 -- 5 to 10 5 to 10 -- YS3N-12F 1NC 38 to 45 -- 38 to 45 6 to 12 -- 8 to 13 YS3N-20FG2, -25FG2 45 to 53 45 to 53 36 to 46 6 to 12 6 to 12 10 to 16 YS3N-32FG2, -38FG2 59 to 68 57 to 66 46 to 56 7 to 19 7 to 19 14 to 23 YS3N-40FG2, -50FG2, -65FG2 46 to 56 46 to 56 34 to 47 23 to 32 23 to 32 27 to 36 YS3N-80FG2, -100FG2, -125FG2 32 to 42 32 to 42 24 to 36 36 to 56 36 to 56 42 to 62 Operating Limited Distances Rated Operational Voltage 100VDC Rated Operational Voltage 200VDC Coil Applied Voltage 100VDC Coil Applied Voltage 200VDC Part Number Wire Sectional Area Wire Sectional Area 1.25mm2 2mm2 3.5mm2 1.25mm2 2mm2 3.5mm2 YS3N-9FG2, -12FG2 3.2 km 5.0 km 9.2 km 12.6 km 19.7 km 36.4 km YS3N-20FG2, -25FG2 3.2 km 5.0 km 9.2 km 12.6 km 19.7 km 36.4 km YS3N-32FG2, -38FG2 2.1 km 3.4 km 6.3 km 9.1 km 14.3 km 26.3 km YS3N-40FG2, -50FG2, -65FG2 YS3N-80FG2, -100FG2, -125FG2 www.idec.com 1.6 km 2.5 km 4.6 km 6.2 km 9.7 km 18.0 km 0.136 km 0.213 km 0.392 km 0.507 km 0.794 km 1.46 km USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-19 IEC Contactors Specifications Electrical Life Curves Electrical Life Curves YS1N-300F YS1N-220F YS1N-180F YS1N-150F YS1N-125F YS1N-100F YS1N-80F YS1N-65F YS1N-38F,-40F YS1N-50F 10 YS1N-20F YS1N-9F Millions of Operating Cycles YS1N-12F Fig.1 Utilization Category AC3 AC3 Ue < 440V 5 4 3 2 D IEC Contactors 0.5 0.4 0.3 0.2 1 2 3 4 5 10 9 YS1N-32F YS1N-25F 1 20 12 30 18 40 50 25 65 100 150 200 105 125 180 209 300 400 500 Breaking current Ic (A) 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 65 90 140 1000 250 220 280 220V 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 55 75 110 160 200 250 450 380V 0.55 0.75 1.5 440V Power rating in kW - 50 Hz category AC3 2.2 4 5.5 7.5 11 15 18.522 30 37 55 75 90 132 200 280 425 Control of three-phase squirrel cage motors switching off during running The breaking current in AC3, Ic, is equal to Ie. (le= rated operational current of the motor) YS1N-300F YS1N-220F YS1N-180F YS1N-150F YS1N-100F YS1N-125F YS1N-80F YS1N-65F YS1N-50F YS1N-38F,-40F 1 YS1N-20F YS1N-9F Millions of Operating Cycles YS1N-12F Fig. 2 Utilization Category AC4 AC4 380V < Ue 440V 0.5 0.4 0.3 0.2 YS1N-25F 0.05 0.04 0.03 0.02 0.01 10 20 30 40 Breaking current Ic (A) 50 51 69 100 102 111 YS1N-32F 0.1 132 200 300 400 500 180 234 360 510 272 588 1000 702 882 2000 1454 1020 3000 2850 4000 5000 1998 Control of three-phase squirrel cage motors switching off with locked rotor The breaking current in AC4, Ic, is equal to 6 x Ie. (Ie = rated operational current of the motor) D-20 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications YS1N-300F YS1N-180F YS1N-220F YS1N-80F YS1N-100F YS1N-125F YS1N-150F YS1N-65F YS1N-50F YS1N-38F,-40F 10 YS1N-20F YS1N-9F Millions of Operating Cycles YS1N-12F Fig. 3 Utilization Category AC1 AC1 Ue < 440V YS 5 4 3 1N -2 5F 2 1 D 0.2 0.1 1 2 3 4 5 10 20 30 40 50 100 150 200 240 300 260 IEC Contactors YS1N-32F 0.5 0.4 0.3 400 500 350 Breaking current Ic (A) Switching a resistive circuit (cos o 0.95) The breaking current in AC1, Ic, is equal to Ie. (le = rated operational current of the load) Electrical Life in Mixed AC3/AC4 Duty Applications By calculation: In a mixed AC3/AC4 application, electrical life can be calculated using the following formula: L A3 = 1+ P 100 ( A3 -1 ) A4 L: Electrical life in mixed AC3/AC4 application A3: Electrical life for breaking current equal to the rated current of the motor. (AC3 from Fig. 1) A4: Electrical life for a breaking current during starting or plug braking equal to Ic = Kle, where: K6 Ie = rated motor current (AC4 from fig. 2) P/100: ratio of switching off during starting or plug braking www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-21 IEC Contactors Specifications Operating and Mounting Specifications for Contactors and Starters 1. Operating Specifications IEC Contactors D Ambient Temperature -5 to +40C Temperature inside the control panel -5to +55C Relative humidity 45% to 85% RH Altitude No more than 2,000m Vibration resistance 10 to 50Hz 19.6m/s2 (2G) Shock resistance 49.0m/s2 (5G) Storage temperature -40C to +70C 2. Mounting 30 30 Direct Mounting 1. Install the product in a dry area with minimal dust and vibration. 2. Standard mounting is done on a vertical surface in the directions shown in Figure 1. However, a mounting angle up to 30 degrees is allowed in each direction as shown in Figure 2. Operational characteristics of the product, when mounted with these angles are listed on the next page. 30 30 Figure 1 Figure 2 DIN Rail Mounting YS Series electromagnetic contactors/starters YS1N/YS2N-9F through -38F models can be mounted on 35mm wide DIN rail, and YS1N/ YS2N -40F through -65F models can be mounted on 75 mm wide DIN rails, as specified in the table below. When mounting the product on DIN rails, keep in mind the following points: 1. Spacing between the products: contributes to a temperature rise and affects the product life. Maintain the minimum spacing as specified in the table below 2. DIN rail mounting holes: To ensure sufficient mechanical strength, the mounting holes should be placed no further apart than those specified in the table below. Product Category Contactor Starter DIN rail width (mm) Minimum spacing between contactors (mm) Distance between mounting screws (mm) (G) (L) YS1N-9F YS2N-9F 35 5 300 YS1N-12F YS2N-12F 35 5 300 YS1N-20F YS2N-20F 35 5 300 YS1N-25F YS2N-25F 35 5 300 YS1N-32F YS2N-32F 35 5 300 YS1N-38F YS2N-38F 35 5 300 YS1N-40F YS2N-40F 75 5 300 YS1N-50F YS2N-50F 75 5 300 YS1N-65F YS2N-65F 75 5 300 D-22 www.idec.com Minimum Space Between Contactors (mm) G Distance Between Mounting Screws L L L Mounting Screw USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Mounting Angle and Operational Characteristics of the YS1N, YS2N, YS1R, YS2R Maximum turn-on voltage (V) Contactor /Starter Minimum turn-off voltage (V) NonReversing reversing Coil Frequency (Hz) Standard/ normal mounting 30 left 30 right 30 tilted forward 30 tilted Standard/ backwards normal mounting 30 left 30 right 30 tilted forward 30 tilted backwards YS1R/ YS2R -9F -9F 50 60 114 126 111 123 110 121 118 129 104 120 84 102 82 98 80 95 82 96 78 90 -12F -12F 50 60 114 126 111 123 110 121 118 129 104 120 84 102 82 98 80 95 82 96 78 90 -20F -20F 50 60 122 138 120 136 121 138 124 140 115 132 105 119 102 111 99 112 103 118 101 117 -25F -25F 50 60 122 138 120 136 121 138 124 140 115 132 105 119 102 111 99 112 103 118 101 117 -32F -32F 50 60 114 132 114 133 112 130 124 145 99 114 78 95 77 93 83 96 81 96 78 91 -38F -38F 50 60 114 132 114 133 112 130 124 145 99 114 78 95 77 93 83 96 81 96 78 91 -40F -40F 50 60 114 132 114 133 112 130 124 145 99 114 78 95 77 93 83 96 81 96 78 91 -50F -50F 50 60 116 138 117 135 116 137 131 149 107 128 91 110 88 108 87 106 86 106 84 105 -65F -65F 50 60 116 138 117 135 116 137 131 149 107 128 91 110 88 108 87 106 86 106 84 105 -80F -80F 50 60 132 134 132 134 132 134 137 137 132 134 83 82 83 82 83 82 83 82 83 82 -100F -100F 50 60 132 134 132 134 132 134 137 137 132 134 83 82 83 82 83 82 83 82 83 82 -125F -125F 50 60 132 134 132 134 132 134 137 137 132 134 83 82 83 82 83 82 83 82 83 82 Coils with the following rated voltage were used to obtain the above values: YS1N-9F to-65F: 200V 50Hz, 200-200V 60Hz YS1N-80F to-125F: 200-220V 50Hz, 200-220V 60Hz www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-23 D IEC Contactors YS1N/ YS2N IEC Contactors Specifications Operating and Mounting Specifications for Thermal Overload Relays Ratings and Characteristics: Part Number:YS1T-RHA 25F-D 38F-D 65F-D 125F-D 150F-D 180F-D Contact Configuration 300F-D 1NO+1NC Number of Elements 3 Trip Free Reset Operation Convertible from manual to automatic Ambient Temperature Compensation -25 to +55C Dial Designation Rated current Setting Scale Indication Ampere (A) Operation Position 30 with respect to the normal position (See chart on page 65) Tripping Class Conforming to UL 508, EN 60947-4 Main Circuit IEC Contactors D 400F-D Rated Insulation Voltage (V) Range of Setting Current (A) Stranded Wire without Ferrule Solid Wire without Ferrule 10 750 0.1-25 7-40 9-65 37-125 65-160 85-185 96-240 128-320 1 Conductor mm2 0.1-25 5-25 5-25 8-60 8-100 8-100 14-150 14-150 2 Conductors mm2 1.5-10 5-16 5-16 8-22 8-50 8-50 14-80 14-80 1 Conductor mm2 1.5-6 5-25 5-25 - - - - - 2 Conductors mm2 1.5-6 5-16 5-16 - - - - - Characteristics of Auxiliary Contacts: Rated Thermal Current 4A AC (AC-15) Rated Operational Current per EN 60947-5-1 DC (DC-13) Rated Voltage 24V AC 48V AC 110V AC 220V AC 380V AC 600V AC Rated Current 4A 4A 3A 2A 1.5A 0.3A Rated Voltage 24V DC 48V DC 110V DC 220V DC Rated Current 1A 0.5A 0.25A 0.1A Stranded Wire without Ferrule 4mm2 (10AWG) Solid Wire without Ferrule 4mm2 (10AWG) Stranded Wire without Ferrule 1mm2 (18AWG) Solid Wire without Ferrule 1mm2 (18AWG) Maximum Cross Section Minimum Cross Section UL / c-UL Ratings of Auxiliary Contacts: Rated Thermal Current AC (C600) Rated Voltage 120V AC 240V AC 480V AC 600V AC Rated Current 1.5A 0.75A 0.4A 0.3A DC (R300) Rated Voltage 125V DC 250V DC Rated Current 0.2A 0.1A Rated Operational Current per UL 508 D-24 4A www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Fig. 4 Tripping Curves Tripping Time (sec.) 10000 5000 Average operating times, depending on the multiples of the current 2000 1000 500 200 100 50 D 20 2 Balanced operation, 2-phase, from cold state. 5 1 2 2 3 Balanced operation, 3-phase, after a long period of set current flow (hot state). 1 3 0.5 1 2 5 10 IEC Contactors 1 Balanced operation, 3-phase, from cold state. 10 20 Multiple of Current Setting Reset Mode Selection and Setting H HAND AUTO A Function Position AUTO R NO Tripping Check R HAND H Reset A Hand-Reset YES YES NO Hand-Reset Auto-Reset Auto-Reset 97 95 97 95 98 96 98 96 Contact Condition Insert screwdriver into the select button, turn it clockwise to the "H" position. Dotted line indicates the condition when the reset button is depressed. The select button is set in "HAND" position, when shipped from factory. Depress the reset button to below 1 , insert screwdriver into the select button, turn counter-clockwise to the "AUTO" position 2 97 95 98 96 Insert screwdriver into the select button, turn counter-clockwise to the "A" position. 2 Select Button (Red) Setting Method Reset Button (Gray) 1 Remarks www.idec.com Can't check manual trip when in Hand-reset condition Normal position for Hand-reset Normal position for Auto-reset Can't check manual trip when in Auto-reset condition USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-25 IEC Contactors Specifications Operating Time Characteristics of Thermal Overload Relays 1000 1000 500 500 100 100 10 5 1 0.5 0.1 100 200 300 400 500 600 700 50 10 5 1 0.5 0.1 100 800 Current (% of Steady State) 300 400 500 600 700 800 500 100 100 10 5 1 0.5 0.1 100 200 300 400 500 600 700 Current (% of Steady State) www.idec.com 800 50 10 5 Load Characteristics 50 Operating Time (In Seconds) 500 Starting Characteristic 1000 Starting Characteristic YS1T-RHA150F 1000 Load Characteristics Operating Time (In Seconds) 200 Current (% of Steady State) YS1T-RHA125F D-26 Load Characteristics Starting Characteristic 50 Operating Time (In Seconds) IEC Contactors D YS1T-RHA25F Load Characteristics Starting Characteristic Operating Time (In Seconds) YS1T-RHA38F, YS1T-RHA65F 1 0.5 0.1 100 200 300 400 500 600 700 800 Current (% of Steady State) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Operating Time Characteristics of Thermal Overload Relays, continued 500 100 100 10 5 0.5 0.1 100 200 300 400 500 600 700 Current (% of Steady State) www.idec.com 800 10 5 1 0.5 0.1 100 D 200 300 400 500 600 700 IEC Contactors 1 50 Load Characteristics 50 Operating Time (In Seconds) 500 Starting Characteristics 1000 Load Characteristics Operating Time (In Seconds) 1000 Starting Characteristics YS1T-RHA300F, YS1T-RHA400F YS1T-RHA180F 800 Current (% of Steady State) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-27 IEC Contactors Specifications Specifications for Accessories AC Ratings of Auxiliary Contacts YS1N-9F to -300F Rated Insulation Voltage (V) Rated Thermal Current (A) AC Ratings per EN AC Ratings (EN-60947-5-1) IEC Contactors D 660 10 Rated Operational Current AC-15 (A) UL / c-UL AC Ratings (UL 508) AC 200-2240V 3 AC 380-480V 1.5 AC 500-600V 1.2 Rated Insulation Voltage (V) 600 Rated Thermal Current (A) 10 Rated Operational Current (NEMA A600) AC 120V 6 AC 240V 3 AC 480V 1.5 AC 600V 1.2 Wire Sizes for Auxiliary Contacts Minimum-Maximum Wire Size YS1N-9F to -300F mm2 1 Conductor (AWG) 1-4 (18-10) 2 Conductors mm2 (AWG) 1-4 (18-10) 1 Conductor mm2 (AWG) 1-4 (18-10) 2 Conductors mm2 (AWG) 1-4 (18-10) Stranded Wire (without ferrule) Solid Wire (ferrule) Instructions for Assembling Auxiliary Contact Blocks: For each magnetic contactor/starter, up to four contacts of the auxiliary contact blocks can be mounted. Two contacts of the top-mount style and two contacts of the side mount style can be combined. YS1A-TAH2 YS1A-TAH4 YS1A-TAH2 YS1A-TAS2 YS1A-TAS2 YS1A-TAS2 YS1A-TAH2 YS1A-TAS2 YS1A-TAS2 YS1A-TAH4 YS1A-TAS2 YS1A-TAS2 Terminal Numbers and Mounting Examples of Auxiliary Contact Blocks, Side-Mount Style YS1N-9F to -65F B @ A C D-28 R S T F D E G U V W YS1R-9F to -65F B @ A C R S T R S U V F D E G U V W www.idec.com T B F D @ E A G W C Note: If you would like to mount two side-mount auxiliary contact blocks (TAS style) to a YS1N non-reversing contactor, mount YS1A-TAS211F. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Mounting and Removing Auxiliary Contact Block on the Contactor Top Mount Style 1. Position the contactor and the auxiliary contact block in the same direction. 2. Insert the auxiliary contact block into the area of the top of the contactor. Slide the auxiliary contact until it bottoms (Do not force.) Make sure that the locking hook is locked into position as shown Removal Procedure While lightly lifting the locking hook with your finger, slide the auxiliary contact unit out. D IEC Contactors Side-Mount Style 1. Contactor plunger 2. Inside this area, there are locking hooks (upper and lower areas) DIN rail Mounting 1. Make sure that the auxiliary contact block (right or left side) and the terminal numbers on the contactor are in the same direction. 2. Push the plunger of the contactor downwards approximately 2mm. While holding the plunger in this manner, insert the white protruding portion of the auxiliary contact block into the square groove of the side of the contactor. Make sure that the locking hook is locked into position. Removal Procedure Hold the auxiliary contact block and pull it off. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-29 IEC Contactors Specifications Surge Suppressor Module Connection Terminal (M3,5) 6.2 4.7 Internal Circuit RC Type 34 Operational Indicator (LED) 22 Varistor Type 26 Connection Terminal (M3,5) 6.2 Internal Circuit 47 D RC Type 44 Operational Indicator (LED) Varistor Type 32 37 21 3 D B B C 1 YS9Z-TU25 78.5 100 12 76 64 E YS1N-12F 1 YS9Z-TU25 78.5 100 12 76 64 YS1N-20F 2 YS9Z-TU25 85 103 12 91 75 YS1N-32F 2 YS9Z-TU65 92 128 12 111 75 YS1N-38F 2 YS9Z-TU65 92 128 12 111 88 YS1N-50F 2 YS9Z-TU65 114 162 12 121 88 YS1N-65F 2 YS9Z-TU65 114 162 12 121 106 YS1N-80F 2 YS9Z-TU65 191 240 12.4 143.5 106 Figure 1 D B E D C A YS1N-9F E Surge Suppressor Module A Figure Number A Contactor Size Dimensions C IEC Contactors 22 Figure 2 Mounting Procedure 1. Line up the surge suppressor module and the contactor as shown in the figure on the right. (Make sure the orientation of the surge suppressor module is such that the LED is visible.) 2. Insert the U-shaped indentations of the surge suppressor module into the connection flange of the contactor as shown in the figure on the right. 3. Loosen the contactor screws, insert the fork lugs of the surge suppressor module, and re-tighten the screw terminals. Connection indentation, U-shaped(on both sides of the surge suppressor module) Removal Procedure 1. Loosen coil screw terminals and remove the fork lugs of the surge suppressor module. 2. Insert a screwdriver between the U-shaped indentation of the surge suppressor module and the connection flange of the contactor, and pry the module off the contactor. D-30 www.idec.com Connection flange USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Specifications of Relay Interface Module YS9Z-TCU500UH Rated Voltage 24V DC Maximum Allowable Voltage Input (coil) 130% of rated voltage Power Consumption 0.2W Pick-up Voltage (at 20C) 70% of rated voltage Drop-out Voltage (at 20C) 10% of rated voltage Maximum Operational Voltage 380V AC Rated Operational Current (at 250V AC) Output (contact) 2A (coso=0.4) Thermal Current 5A Closing Delay 3 ms Opening Delay 1 ms Temperature Range Maximum Operational Voltage 250V AC Function IEC Contactors Surge Suppressor Device D -20 to +55C Resistor capacitor circuit (RC) Applicable Control Coil Voltage Range Up to 240V AC (50/60 Hz) Relay Interface Completed Part Numbers Relay Interface Module YS9Z-TCU Applicable Contactor Completed Part Number Dimensions W H D YS1N-9F YS1N-12F YS9Z-TCU500UH12 49 125 76 YS1N-20F YS1N-25F YS9Z-TCU500UH25 49 135 91 YS1N-32F YS1N-38F YS9Z-TCU500UH38 58 140 111 YS1N-40F YS1N-50F YS1N-65F YS9Z-TCU500UH65 75 160 121 YS1N-80F YS1N-100F YS1N-125F YS9Z-TCU500UH125 100 187 133 YS1N-150F YS1N-180F YS9Z-TCU500UH180 130 225 158 YS1N-220F YS1N-300F YS9Z-TCU500UH300 146 260 184 H Product Series W D NOTES: Each model is identical in electrical characteristics, mounting plate sizes representing the only difference. CONNECTION DIAGRAM AND INTERNAL CIRCUIT OF THE RELAY INTERFACE MODULE b A2 (+) e RY E MC d (-) f PLC www.idec.com c R C (RELAY INTERFACE MODULE) a A1 CONTACTOR USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-31 IEC Contactors Specifications Mechanical Interlock Blocks Reversing Contactors Dimensions Mechanical Interlock Block A B C D YS1R-9F YS9Z-TMI65 78.5 100 12 76 YS1R-12F YS9Z-TMI65 78.5 100 12 76 YS1R-20F YS9Z-TMI65 85 103 12 91 YS1R-25F YS9Z-TMI65 85 103 12 91 YS1R-32F YS9Z-TMI65 92 128 12 111 YS1R-38F YS9Z-TMI65 92 128 12 111 YS1R-40F YS9Z-TMI65 92 128 12 111 YS1R-50F YS9Z-TMI65 114 162 12 121 D YS1R-65F YS9Z-TMI65 114 162 12 121 YS1R-80F YS9Z-TMI125 191 240 12.4 143.5 IEC Contactors Contactor Size YS1R-100F YS9Z-TMI125 191 240 12.4 143.5 YS1R-125F YS9Z-TMI125 191 240 12.4 143.5 YS1R-150F YS9Z-TMI125 239 300 12.4 169.5 YS1R-180F YS9Z-TMI125 239 300 12.4 169.5 YS1R-220F YS9Z-TMI125 269 305 12.4 195 YS1R-300F YS9Z-TMI125 269 305 12.4 195 D A B C Note: 1. The mounting holes are the same as theYS1 Series. 2. The above figures are not drawn to scale. Refer to the chart for actual dimensions. 3. YS1N-80F~-300F size contactors require an additional mounting base. Refer to the YS1R-80F through -300F in the dimension chart. Reversing Starters Dimensions Mechanical Interlock Block A B C D YS2R-9F YS9Z-TMI65 78.5 100 12 76 YS2R-12F YS9Z-TMI65 78.5 100 12 76 YS2R-20F YS9Z-TMI65 85 103 12 91 YS2R-25F YS9Z-TMI65 85 103 12 91 YS2R-32F YS9Z-TMI65 92 128 12 111 YS2R-38F YS9Z-TMI65 92 128 12 111 YS2R-40F YS9Z-TMI65 92 128 12 111 YS2R-50F YS9Z-TMI65 114 162 12 121 YS2R-65F YS9Z-TMI65 114 162 12 121 YS2R-80F YS9Z-TMI125 191 240 12.4 143.5 YS2R-100F YS9Z-TMI125 191 240 12.4 143.5 YS2R-125F YS9Z-TMI125 191 240 12.4 143.5 YS2R-150F YS9Z-TMI125 239 300 12.4 169.5 YS2R-180F YS9Z-TMI125 239 300 12.4 169.5 YS2R-220F YS9Z-TMI125 269 305 12.4 195 YS2R-300F YS9Z-TMI125 269 305 12.4 195 B C D A Contactor Size Note: 1. The mounting holes are the same as the YS1 Series. 2. The above figures are not drawn to scale. Refer to the chart for actual dimensions. 3. YS1N-80F through 300F contactors require an additional mounting base. Refer to the YS2R-80F~-300F in the dimension chart. D-32 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Specifications Mounting and Removing of Mechanical Interlock Block Mounting Procedure (YS9Z-TMI65) 1. Position the mechanical interlock block and the contactor in the same direction. (The name plate of the mechanical interlock block should be in the same direction as the name plate of the contactor. 2. Insert the connection pins of the mechanical interlock block (located on the left and right sides of the mechanical interlock block) into the pin holes of the forward and reverse contactors (the forward contactor in the right and the reverse contactor in the left in the picture). Carefully push the contactors towards the mechanical interlock block to lock the entire assembly together. Mounting base The arrow-shaped protrusion of the mechanical interlock goes into this hole 3. Insert the mounting base into the bottom of the mechanical interlock block until it bottoms. (Make sure that the arrow -shaped protrusion of the mechanical interlock as far as it will go. Removal Procedure 1. To remove the mechanical interlock block, insert a screwdriver into the space between the mechanical interlock block and the mounting base. Mechanical interlock block IEC Contactors 2. Remove the mounting base from the assembly. 3. Gently pull the forward and reverse contactors apart. Mounting Procedure (YS9Z-TMI125) 1. Position the mechanical interlock and the contactor in the same direction. (The name plate of the mechanical interlock should be in the same direction as the name plate of the contactor.) 2. Insert the connection pin of the mechanical interlock into the connection pin hole located on the right side of the forward contactor. The 7 - shaped hook of the mechanical interlock reaches the contactor. Position the 7 - shaped hook of the mechanical interlock to match the ribbed area of the contactor and press the mechanical interlock block towards the forward contactor. 3. For the reverse contactor, follow the same procedure above, but insert the connection pin of the mechanical interlock block into the pin hole located on the left side of the reverse contactor. (Note: The mounting order of the forward or the reverse contactor does not make a difference in the assembly procedure.) 4. After the mechanical interlock block is installed to both contactors, mount the contactors to the mounting base with the screws (4 screws for each contactor, total of 8 screws.) Make sure that the mechanical interlock block is completely locked to the contactors. Please note that there can be operational problems if the mechanical interlock and the contactors are not properly locked into position. Removal Procedure 1. Insert a screwdriver into the 7-shaped hook area between either contactor and the mechanical interlock and pry out the mechanical interlock. Mounting Base (Forward) Contactor (Reverse) Contactor Mechanical Interlock Block 7-shaped hook Connection pin hole Connection pin www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D D-33 IEC Contactors Specifications Connector Kits for Reversing Contactors and Starters Used as connectors on reversing contactors (YS1R series) and reversing starters (YS2R series). A1 A2 IEC Contactors D 1 3 5 1 3 5 2 4 6 2 4 6 A1 A1 A2 A2 1 3 5 1 3 5 2 4 6 2 4 6 A1 A2 Power Wiring Kits for Reversing Contactors Applicable Reversing Contactors Part Number Connections Description YS9Z-KIF411344-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 UL1015 Solid Wire AWG 14 YS1R-9F YS1R-12F YS9Z-KIF411345-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 UL1015 Stranded Wire AWG 10 YS1R-20F YS1R-25F YS9Z-KIF411346-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 UL1283 Stranded Wire AWG 8 YS1R-32F YS1R-38F YS9Z-KIF411347-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 Copper Bar Solid Bar AWG 6 YS1R-40F YS1R-50F YS1R-65F YS9Z-KIF411348-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 Copper Bar Solid Bar 1.6 X11 YS1R-80F YS1R-100F YS1R-125F YS9Z-KIF411388-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 Copper Bar Solid Bar 3 X16 YS1R-150F YS9Z-KIF411388-B F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 Copper Bar Solid Bar 3 X20 YS1R-180F YS9Z-KIF411590-A F:L1-R:L1 F:L2-R:L2 F:L3-R:L3 F:T1-R:T3 F:T2-R:T2 F:T3-R:T1 Copper Bar Solid Bar 3.5X25 YS1R-220F YS1R-300F D-34 www.idec.com Size USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Dimensions Non-Reversing AC Contactors All Dimensions in mm. Non-Reversing Contactors YS1N-40F, YS1N-50F, YS1N-65F 12 114 110 (YS1A-TAS) (YS1A-TAS) (YS1A-TAH) 12 (YS1A-TAS) YS1N-20F, YS1N-25F 12 100 YS1N-32F, YS1N-38F 58 www.idec.com 12 (YS1A-TAS) 30 YS1N-150F 133 158 101.5 (YS9Z-TU65) 111 92 9 12 141 97 (YS9Z-TU25) 124 (YS1A-TAH) (YS1A-TAS) (YS1A-TAS) (YS1A-TAS) 154 (YS1A-TAH) 91 85 45.5 12 (YS1A-TAS) YS1N-80F, YS1N-100F, YS1N-125F 8 12 75 180 44 D IEC Contactors 12 121 89 (YS9Z-TU25) 78.5 9 (YS9Z-TU65) 76 8 119.5 YS1N-9F, YS1N-12F 143.5 (YS1A-TAH) 130 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 188 D-35 IEC Contactors Dimensions Non-Reversing Contactors YS1N-180F YS1N-220F, YS1N-300F 184 D 210 180 158 188 130 234 IEC Contactors 146 Non-Reversing DC Contactors Non-Reversing Contactors DC Operated YS3N -80FG, YS3N -100FG, YS3N -125FG YS3N -9FG2, YS3N -12FG2 141 107.5 81.4 8 44 100 133 YS3N -32FG2, YS3N -38FG2 YS3N -20FG2, YS3N -25FG2 9 118.5 138 92 86.5 8 30 45.5 58 YS3N -40FG2, YS3N -50FG2, YS3N-65FG2 160 114 9 75 D-36 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Dimensions Non-Reversing AC Starters Non-Reversing Starters YS2N-40F, YS2N-50F, YS2N-65F YS2N-9F, YS2N-12F 75 76 121 168 128 44 D IEC Contactors 45 90.5 56 105 YS2N-80F, YS2N-100F, YS2N-125F YS2N-20F, YS2N-25F 100 91 45 92.5 133 224 133.5 45.5 100 YS2N-32F, YS2N-38F 117 YS2N-150F 56 106 130 158 259.5 111 150 58 www.idec.com 100 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 122 D-37 IEC Contactors Dimensions Non-Reversing Starters YS2N-180F YS2N-220F, YS2N-300F 158 191.5 315 294.5 130 IEC Contactors D 100 D-38 122 www.idec.com 250 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Dimensions Reversing AC Contactors Reversing Contactors 100 12 110 12 (YS1A-TAH) (YS1A-TAS) 85 78.5 12 (YS1A-TAS) 91 8 103 12 (YS1A-TAS) (YS1A-TAS) 97 (YS9Z-TU25) YS1R-20F, HCA-25F 76 8 89 (YS9Z-TU25) YS1R-9F, YS1R-12F D 124 (YS1A-TAH) IEC Contactors YS1R-32F, YS1R-38F 92 12 143.5 (YS1A-TAS) 9 121 114 YS1R-40F, YS1R-50F, YS1R-65F (YS1A-TAH) 12 162 12 (YS1A-TAS) (YS1A-TAS) 119.5 128 (YS1A-TAS) (YS9Z-TU65) 12 101.5 (YS9Z-TU65) 111 9 154 (YS1A-TAH) 191 YS1R-80F, YS1R-100F, YS1R-125F 240 www.idec.com 30 143.5 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-39 IEC Contactors Dimensions Reversing Contactors YS1R-150F YS1R-180F 169.5 300 D 239 239 169.5 200 IEC Contactors 300 200 YS1R-220F, YS1R-300F 269 195 305 D-40 www.idec.com 225 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Dimensions Reversing AC Starters Reversing Starters YS2R-32F, YS2R-38F YS2R-9F, YS2R-12F 128 76 111 150 128 100.5 D 45 56 106 YS2R-40F, YS2R-50F, YS2R-65F YS2R-20F, YS2R-25F 91 162 121 45 168 133.5 103 IEC Contactors 90.5 92.5 105 56 YS2R-80F, YS2R-100F, YS2R-125F 143.5 250 240 100 www.idec.com 127.5 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-41 IEC Contactors Dimensions Reversing Starters YS2R-150F YS2R-180F 169.5 D 332.5 297.5 169.5 133.5 100 100 300 IEC Contactors 300 133.5 YS2R-220F, YS2R-300F 373 195 347 D-42 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Mounting/Wiring Non-Reversing AC Contactors Mounting, Screw Mounting, and Rail Mounting Non-Reversing Contactors YS1N-40F, YS1N-50F, YS1N-65F 2-4.8 DIA. MTG HOLES(M4) 15.5 2-4.8 DIA. MTG HOLES(M4) DIN RAIL 35mm B 95 100 50 DIN RAIL 75mm 52 A 48 2-4.8 DIA. MTG HOLES(M4) 2-4.8 DIA. MTG HOLES(M4) 6 YS1N, YS1N-12F 5 D 4.5 B 5 YS1N-20F, YS1N-25F IEC Contactors 34 35 A 65 7 YS1N-80F, YS1N-100F, YS1N-125F 4-6 DIA. MTG HOLES(M5) 2-4.8 DIA. MTG HOLES(M4) 19 110 75 70 5 DIN RAIL 35mm 5.2 35 4.5 80 7 YS1N-32F, YS1N-38F YS1N-150F 2-4.8 DIA. MTG HOLES(M4) 15 100 4-M6 MTG HOLES DIN RAIL 35mm 4 www.idec.com 50 25 130 125 75 70 10.5 2-4.8 DIA. MTG HOLES(M4) 86 4.5 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-43 IEC Contactors Mounting/Wiring Mounting, Screw Mounting, and Rail Mounting, continued Non-Reversing Contactors YS1N-180F 4-M6 MTG HOLES 100 50.5 45 4-M6 MTG HOLES 190 130 125 25 10 15 YS1N-220F, YS1N-300F D Non-Reversing DC Contactors IEC Contactors Non-Reversing Contactors, DC Operated YS3N-80FG, YS3N-100FG, YS3N-125FG YS3N-9FG2, -12FG2 4-6 DIA. MTG HOLES(M5) 2-4.8 DIA. MTG HOLES(M4) 19 2-4.8 DIA. MTG HOLES(M4) 48 50 52 110 DIN Rail 35mm 34 35 4.5 80 86 7 YS3N-20FG2, YS3N-25FG2 YS3N-32FG2, YS3N-38FG2 2-4.8 DIA. MTG HOLES(M4) DIN Rail 35mm 2-4.8 DIA. MTG HOLES(M4) DIN Rail 35mm 35 75 70 75 70 2-4.8 DIA. MTG HOLES(M4) 4.5 50 4.5 YS3N-40FG2, YS3N-50FG2, YS3N-65FG2 B B A 95 A 65 D-44 www.idec.com DIN Rail 75mm 100 2-4.8 DIA. MTG HOLES(M4) 2-4.8 DIA. MTG HOLES(M4) 7 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Mounting/Wiring Reversing AC Contactors Mounting, Screw Mounting, and Rail Mounting Reversing Contactors YS1R-32F, YS1R-38F YS1R-9F, YS1R-12F 34 22 34 10.5 DIN RAIL 35mm 75 DIN RAIL 35mm 70 50 48 15.5 35 4-4.8 DIA. MTG HOLES(M4) 52 4-4.8 DIA. MTG HOLES(M4) 21 35 5 4-4.8 DIA. MTG HOLES(M4) 4-4.8 DIA. MTG HOLES(M4) D 4.5 50 20 50 4.5 IEC Contactors 4 YS1R-20F, YS1R-25F 4-4.8 DIA. MTG HOLES(M4) 5.2 35 22.5 75 70 5 DIN RAIL 35mm 35 4.5 YS1R-40F, YS1R-50F, YS1R-65F 4-4.8 DIA. 4-4.8 DIA. MTG HOLES(M4) MTG HOLES(M4) 6 DIN RAIL 75mm B A B B A B A 95 100 A 5 65 22 65 7 YS1R-80F, YS1R-100F, YS1R-125F 10.5 8 4-7 DIA. MTG HOLES(M6) 7 175 10 10 www.idec.com 220 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-45 IEC Contactors Mounting/Wiring Mounting, Screw Mounting, and Rail Mounting, continued Reversing Contactors YS1R-150F 10 20 4-M8 MTG HOLES 15 4-M8 MTG HOLES 15 10 YS1R-180F 15 270 221 8 8 221 20 15 270 IEC Contactors D YS1R-220F, YS1R-300F 4-M8 MTG HOLES 15 10 15 D-46 275 8 251 30 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Mounting/Wiring Non-Reversing and Reversing Contactors Wiring Diagrams n Non-Reversing Contactors l YS1N-9F, YS1N-12F (1NO) A1 A2 L1 1 L2 3 L3 5 NO 13 2 T1 4 T2 6 T3 14 NO l YS1N-9F, YS1N-12F (1NC) A1 A2 YS1N-40F, YS1N-50F, YS1N-65F A1 A2 L3 5 NO 13 NC 21 2 T1 4 T2 6 T3 14 NO 22 NC L3 5 NC 21 2 T1 4 T2 6 T3 22 NC YS1N-220F, YS1N-300F A1 A2 L1 1 L2 3 L3 5 NO 13 NC 21 NC 31 NO 43 2 T1 4 T2 6 T3 14 NO 22 NC 32 NC 44 NO D IEC Contactors L2 3 L2 3 l YS1N-80F, YS1N-100F, YS1N-125F, YS1N-150F, YS1N-180F l YS1N-20F, YS1N-25F, YS1N-32F, YS1N-38F L1 1 L1 1 n Reversing Contactors l YS1R-9F, YS1R-12F (1NCX2) l YS1R-9F, YS1R-12F (1NOX2) A1 L1 L2 L3 1 3 5 NO 13 1 3 5 NO A1 14 A1 2 4 6 14 NO 2 4 6 13 NO A2 A2 A2 T2 T1 T3 L1 L2 L3 1 3 5 NC 21 1 3 5 NC A1 21 2 4 6 22 NC 2 4 6 22 NC A2 T1 T2 T3 l YS1R-20F, YS1R-25F, YS1R-32F, YS1R-38F, YS1R-40F, YS1R-50F, YS1R-65F L1 L2 L3 1 3 5 NO NC 13 21 1 3 5 NO NC A1 13 21 2 4 6 14 22 NO NC 2 4 6 14 22 NO NC A2 T1 T2 T3 A1 A2 l YS1R-80F, YS1R-100F, YS1R-125F, YS1R-150F, YS1R-180F, YS1R-220F, YS1R-300F A1 L1 L2 L3 1 3 5 NO NC NC NO 13 21 31 43 1 3 5 NO NC NC NO A1 13 21 31 43 2 4 6 14 22 32 44 NO NC NC NO 2 4 6 14 22 32 44 NO NC NC NO A2 T1 T2 T3 A2 n Non-Reversing Contactors DC Operated l YS3N-9FG2, YS3N-12FG2 (1NO) A1 A2 l L1 1 L2 3 L3 5 NO 13 2 T1 4 T2 6 T3 14 NO l YS3N-9FG2, YS3N-12FG2 (1NC) A1 A2 L1 1 L2 3 L3 5 NC 21 2 T1 4 T2 6 T3 22 NC l YS3N-80FG, YS3N-100FG, YS3N-125FG YS3N-20FG2, YS3N-25FG2, YS3N-32G2F l YS3N-38FG2, YS3N-40FG2, YS3N-50FG2, YS3N-65FG2 A1 A2 www.idec.com L1 1 L2 3 L3 5 NO 13 NC 21 2 T1 4 T2 6 T3 14 NO 22 NC A1 A2 L1 1 L2 3 L3 5 NO 13 NC 21 NC 31 NO 43 2 T1 4 T2 6 T3 14 NO 22 NC 32 NC 44 NO USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-47 IEC Contactors Mounting/Wiring Non-Reversing and Reversing Starters Wiring Diagrams Non-Reversing Starters Reversing Starters YS2N-9FD, YS2N-12FD YS2R-9FD, YS2R-12FD (1NO) (1NC) 1 L1 3 L2 5 L3 13 A1 (1NO) 1 L1 3 L2 5 L3 21 A1 A1 4 2 A2 1 6 3 14 97 95 5 4 2 A2 1 3 6 5 22 97 95 D YS2N-38FD, YS2N-40FD, YS2N-50FD, YS2N-65FD IEC Contactors L3 1 3 5 2 4 6 1 L1 3 L2 5 L3 13 4 2 1 3 6 5 A1 13 1 3 5 14 14 2 4 6 13 A2 3 A1 5 L2 L3 1 3 5 2 4 6 A1 21 1 3 5 21 22 2 4 6 22 A2 97 95 2 T1 4 T2 6 T3 A2 1 98 96 3 97 95 5 2 T1 4 T2 6 T3 98 96 YS2R-20FD, YS2R-25FD, YS2R-32FD, YS2R-38FD, YS2R-40FD, YS2R-50FD, YS2R-65FD 21 L1 L2 L3 1 3 5 NO NC 13 21 1 3 5 NO NC A1 13 21 2 4 6 14 22 NO NC 2 4 6 14 22 NO NC A2 A1 A2 (1NC) L1 2 T1 4 T2 6 T3 98 96 YS2N-20FD, YS2N-25FD, YS2N-32FD, A1 L2 A2 1 2 T1 4 T2 6 T3 98 96 L1 14 22 97 95 A2 2 T1 4 T2 6 T3 98 96 1 3 97 95 5 YS2N-80FD, YS2N-100FD, YS2N-125FD, YS2N-150FD, YS2N-180FD 4 2 A2 1 3 6 5 2 T1 4 T2 6 T3 21 31 43 14 22 97 95 32 44 1 L1 3 L2 5 L3 13 A1 YS2R-80FD, YS2R-100FD, YS2R-125FD, YS2R-150FD, YS2R-180FD A1 2 T1 4 T2 6 T3 98 96 L1 L2 L3 1 3 5 NO NC NC NO 13 21 31 43 1 3 5 NO NC NC NO A1 13 21 31 43 2 4 6 14 22 32 44 NO NC NC NO 2 4 6 14 22 32 44 NO NC NC NO A2 A2 YS2N-220FD, YS2N-300FD A1 1 L1 3 L2 5 L3 13 1 21 31 43 22 32 44 3 97 95 5 2 T1 4 T2 6 T3 A2 2 4 6 14 1 3 5 2 4 6 97 95 Thermal Overload Relays 1 L1 3 L2 5 L3 2 T1 4 T2 6 T3 D-48 L1 L2 L3 1 3 5 NO NC NC NO 13 21 31 43 1 3 5 NO NC NC NO A1 13 21 31 43 2 4 6 14 22 32 44 NO NC NC NO 2 4 6 14 22 32 44 NO NC NC NO A2 98 96 A2 F 98 96 YS2R-220FD, YS2R-300FD A1 YS1T-RHA 98 96 1 3 5 97 95 2 4 6 98 96 D 97 95 98 96 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Mounting/Wiring Auxiliary Contact Blocks Wiring Diagrams Auxiliary Contact Blocks YS1A-TAH404F 4NC YS1A-TAH413F 1NO+3NC YS1A-TAH422F 2NO+2NC YS1A-TAH431F 3NO+1NC YS1A-TAH440F 4NO NO NC NC NC 51 61 71 81 NO NC NC NC 53 61 71 81 NO NC NC NO 53 61 71 83 NO NC NO NO 53 61 73 83 NO NO NO NO 53 63 73 83 52 62 72 82 NO NC NC NC 54 62 72 82 NO NC NC NC 54 62 72 84 NO NC NC NO 54 62 74 84 NO NC NO NO 54 64 74 84 NO NO NO NO D 2NC YS1A-TAH211F 1NO+1NC IEC Contactors YS1A-TAH202F YS1A-TAH220F 2NO NC NC 51 61 NO NC 53 61 NO NO 53 63 52 62 NC NC 54 62 NO NC 54 64 NO NO YS1A-TAS211F 1NO+1NC NO NC 53 61 54 62 NO NC www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-49 IEC Contactors Mounting/Wiring Appendix STANDARDIZED UTILIZATION CATEGORIES [Excerpt from EN60947] Class of AC Magnetic Contactors Contactors Typical applications for AC switching Category IEC Contactors D Conditions of making and breaking corresponding to normal operation (dura- Conditions of making and breaking corresponding to occasional operation Making I U cos Breaking I U cos Making I U cos Breaking I U cos Resistive, non-inductive or slightly inductive AC1 Ie Ue 0.95 Ie Ue 0.95 1.5Ie 1.05Ue 0.8 1.5Ie 1.05Ue 0.8 Slip-ring motors Starting, switching AC2 2.5Ie Ue 0.65 2.5Ie Ue 0.65 4Ie 1.05Ue 0.65 4Ie 1.05Ue 0.65 Squirrel cage motors Starting, switching off AC3 6Ie Ue (1) Ie 0.17Ue (1) 10Ie 1.05Ue (2) 8Ie 1.05Ue (2) Squirrel cage motors Starting, plugging inching (jogging) AC4 6Ie Ue (1) 6Ie Ue 12Ie 1.05Ue (2) 10Ie 1.05Ue (2) (1) Notes : (1) cos = 0.65 for Ie 17A cos = 0.35 for Ie > 17A (2) cos = 0.45 for Ie 100A cos = 0.35 for Ie > 100A Class of Auxiliary Contacts Auxiliary Contacts Typical applications for AC switching Category Control of electromagnets < 72 VA sealed > 72 VA sealed D-50 Conditions of making and breaking corresponding to normal operation (dura- Conditions of making and breaking corresponding to occasional operation Making I U AC14 6Ie AC15 10Ie www.idec.com Ue Ue cos Breaking I U cos Making I U 0.3 0.3 Ie Ie 0.3 0.3 6Ie 10Ie Ue Ue cos 1.1Ue 0.7 1.1Ue 0.3 Breaking I U 6Ie 10Ie cos 1.1Ue 0.7 1.1Ue 0.3 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Application Tables Application Tables AC 1 Ratings: (International Applications) Non-inductive or slightly inductive loads, resistance furnaces: Maximum Operational Current AC1 Power Ratings of Three-Phase Motors (50/60Hz) Category AC1 (Star Connection) 380V 400V 415V 440V 500V 660V 690V <55C kW kW kW kW kW kW A 7.5 13 14 15 17 23 7.5 13 14 15 17 7.5 13 14 15 7.5 13 14 11 20 11 Completed Part Number NO NC 20 0 1 YS1N-9F01 * * * * 23 20 1 0 YS1N-9F10 * * * * 17 23 20 0 1 YS1N-12F01 * * * * 15 17 23 20 1 0 YS1N-12F10 * * * * 21 23 26 34 30 1 1 YS1N-20F11 * * * * 20 21 23 26 34 30 1 1 YS1N-25F11 * * * * 19 32 35 38 43 57 50 1 1 YS1N-32F11 * * * * 23 40 43 45 52 68 60 1 1 YS1N-38F11 * * * * 23 40 43 45 52 68 60 1 1 YS1N-40F11 * * * * 30 52 57 61 69 91 80 1 1 YS1N-50F11 * * * * 30 52 57 61 69 91 80 1 1 YS1N-65F11 * * * * 51 88 97 102 116 154 135 2 2 YS1N-80F22 * * * * 57 98 107 114 129 171 150 2 2 YS1N-100F22 * * * * 57 98 107 114 129 171 150 2 2 YS1N-125F22 * * * * 76 132 144 152 173 229 200 2 2 YS1N-150F22 * * * * 91 158 173 183 208 274 240 2 2 YS1N-180F22 * * * * 99 171 187 198 225 297 260 2 2 YS1N-220F22 * * * * 133 230 252 267 303 400 350 2 2 YS1N-300F22 * * * * www.idec.com D USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors 220V 230V Instantaneous Auxiliary Contacts D-51 IEC Contactors Application Tables AC2 Ratings: Slip-ring motors; starting, switching off running motors (International Applications) AC4 Ratings: Squirrel-cage motors; starting, plugging, inching Power Ratings of Three-Phase Motors (50/60Hz) Instantaneous Auxiliary Contacts Category AC2 or AC4 IEC Contactors D 220V 230V 380V 400V 415V 440V 500V 660V 690V kW kW kW kW kW kW 2.2 4 4 4 5.5 2.2 4 4 4 3 5.5 5.5 3 5.5 4 Completed Part Number NO NC 5.5 0 1 YS1N-9F01 * * * * 5.5 5.5 1 0 YS1N-9F10 * * * * 5.5 5.5 7.5 0 1 YS1N-12F01 * * * * 5.5 5.5 5.5 7.5 1 0 YS1N-12F10 * * * * 7.5 9 9 9 9 1 1 YS1N-20F11 * * * * 5.5 9 9 9 10 10 1 1 YS1N-25F11 * * * * 7.5 11 11 11 15 15 1 1 YS1N-32F11 * * * * 11 15 15 15 15 18.5 1 1 YS1N-38F11 * * * * 11 15 15 15 15 18.5 1 1 YS1N-40F11 * * * * 15 18.5 18.5 22 22 22 1 1 YS1N-50F11 * * * * 18.5 22 22 30 25 25 1 1 YS1N-65F11 * * * * 22 30 33 33 37 33 2 2 YS1N-80F22 * * * * 30 45 45 45 45 45 2 2 YS1N-100F22 * * * * 37 51 51 51 51 51 2 2 YS1N-125F22 * * * * 45 63 63 63 63 63 2 2 YS1N-150F22 * * * * 55 80 80 80 80 75 2 2 YS1N-180F22 * * * * 65 90 90 90 90 90 2 2 YS1N-220F22 * * * * 90 129 129 129 110 140 2 2 YS1N-300F22 * * * * D-52 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Application Tables AC3 Ratings: (International Applications) Squirrel-cage motors--starting & switching off running motors: Power Ratings for Three - Phase Motors 50/60Hz Category AC3 --for ambient air temperature around contactor 55 C Maximum Operational Current 380V 400V 415V 440V 500V 660V 690V AC3 Duty 380-440V kW/HP kW/HP kW/HP kW/HP kW/HP kW/HP A 2.2/3 4/5.5 4/5.5 4/5.5 5.5/7.5 5.5/7.5 2.2/3 4/5.5 4/5.5 4/5.5 5.5/7.5 3/4 5.5/7.5 5.5/7.5 5.5/7.5 3/4 5.5/7.5 5.5/7.5 4/5.5 7.5/10 5.5/7.5 Completed Part Number NO NC 8.5 0 1 YS1N-9F01 * * * * 5.5/7.5 8.5 1 0 YS1N-9F10 * * * * 7.5/10 7.5/10 11.5 0 1 YS1N-12F01 * * * * 5.5/7.5 7.5/10 7.5/10 11.5 1 0 YS1N-12F10 * * * * 9/12 9/12 10/13.5 10/13.5 15.5 1 1 YS1N-20F11 * * * * 11/15 11/15 11/15 15/20 15/20 22 1 1 YS1N-25F11 * * * * 7.5/10 15/20 15/20 15/20 18.5/25 18.5/25 30 1 1 YS1N-32F11 * * * * 11/15 18.5/25 22/30 22/30 22/30 30/40 37 1 1 YS1N-38F11 * * * * 11/15 18.5/25 22/30 22/30 22/30 30/40 37 1 1 YS1N-40F11 * * * * 15/20 22/30 25/35 30/40 30/40 33/44 44 1 1 YS1N-50F11 * * * * 18.5/25 30/40 37/50 37/50 37/50 37/50 60 1 1 YS1N-65F11 * * * * 22/30 45/54 45/60 45/60 55/75 45/60 85 2 2 YS1N-80F22 * * * * 30/40 55/75 55/75 60/80 65/87 65/87 105 2 2 YS1N-100F22 * * * * 37/50 60/80 63/85 63/85 75/100 75/100 114 2 2 YS1N-125F22 * * * * 45/60 75/100 80/110 80/110 90/125 100/136 138 2 2 YS1N-150F22 * * * * 55/75 95/130 100/136 110/150 110/150 110/150 179 2 2 YS1N-180F22 * * * * 65/87 110/150 110/150 110/150 132/180 132/180 205 2 2 YS1N-220F22 * * * * 90/125 160/220 160/220 160/220 160/220 200/270 300 2 2 YS1N-300F22 * * * * www.idec.com D USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors 220V 230V Instantaneous Auxiliary Contacts D-53 IEC Contactors Application Tables DC Loads: DC2, DC4 L/R=15ms DC Motor Load (A) 48V 110V 220V DC11 L/R=100ms Inductive Load (A) 48V 110V 220V 12 12 12 13 13 13 13 13 13 15 20 20 26 26 26 30 30 35 30 30 35 30 50 50 50 65 65 65 80 80 80 93 93 80 100 125 125 125 150 125 150 180 3 6 40 3 6 13 3 6 13 8 15 20 10 20 25 10 30 35 10 30 35 15 35 40 20 40 50 30 65 65 30 80 80 30 85 100 50 125 150 50 125 180 1 5 8 1 5 8 1 5 8 3 12 15 3 20 20 5 20 25 5 20 25 5 20 25 5 20 25 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1.5 4 8 1.5 4 8 2 4 8 2 8 15 3 10 20 3 15 20 3 15 20 3 15 20 4 25 30 4 40 65 4 50 65 4 50 65 5 80 100 5 80 100 1 Series Connection +V DC L1 T1 -V DC 0.25 1.2 4 0.25 1.2 4 0.25 1.2 4 0.4 2 8 0.4 3 10 0.4 3 10 0.4 3 10 0.4 3 10 0.4 3 20 0.5 4 30 0.5 4 40 0.5 4 50 0.5 5 65 0.5 5 80 2 Series Connection T1 0.8 0.6 1.5 0.2 0.6 1.5 0.25 0.6 1.5 0.3 1.2 2 0.4 1.5 2 0.4 1.5 2 0.4 1.5 2 0.4 1.5 2 0.4 1.5 2 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Part No. YS1N-9F##**** YS1N-12F##**** YS1N-20F11**** YS1N-25F11**** YS1N-32F11**** YS1N-38F11**** YS1N-40F11**** YS1N-50F11**** YS1N-65F11**** YS1N-80F11**** YS1N-100F11**** YS1N-125F11**** YS1N-150F11**** YS1N-180F11**** 3 Series Connection +V DC +V DC L1 0.7 3 4 0.7 3 4 0.7 3 4 1.2 5 10 1.2 5 15 1.5 5 15 1.5 5 15 1.5 5 15 1.5 5 15 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- No. of Series Connection -V DC T3 L1 L2 L3 T1 T2 LOAD 1 6 12 1 6 13 1 6 13 1.5 10 15 2 15 26 2 20 30 2 20 30 2 20 35 2 20 50 3 30 65 3 40 80 3 50 100 4 65 125 4 80 150 LOAD 10 10 12 10 10 13 10 10 13 12 15 20 15 26 26 15 30 35 15 30 35 15 35 50 30 50 65 35 65 80 35 80 93 35 100 125 35 100 150 35 125 180 LOAD IEC Contactors D DC1, DC14 L/R=1ms Resistance Load (A) 48V 110V 220V T3 L3 -V DC D-54 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Application Tables Application to Star (Wye)-Delta Motor Starters 3-Phase Motor Power Rating Voltage (V) Frequency (Hz) 200-240V 50/60 Hz 50/60 Hz Current Type of Magnetic Contactors Type of Overload Relay (kW) (HP) (A) Main Star Delta 3.7 5 17.5 YS-9F YS-9F YS-9F Part Number 5.5 7.5 26 YS-9F YS-9F YS-9F RHA-25F/21DP 7.5 10 34 YS-9F YS-9F YS-20F RHA-65F/25D + TIB-65F 11 15 48 YS-20F YS-9F YS-25F RHA-65F/43D + TIB-65F 15 20 65 YS-32F YS-20F YS-32F RHA-65F/56D + TIB-65F 18.5 25 79 YS-32F YS-20F YS-38F RHA-125F/68DP 22 30 93 YS-32F YS-32F YS-50F RHA-125F/80DP 30 40 125 YS-50F YS-32F YS-65F RHA-125F/105DP 37 50 148 YS-50F YS-32F YS-80F RHA-150F/135DP 45 60 180 YS-80F YS-50F YS-100F RHA-180F/155DP 55 75 220 YS-125F YS-50 YS-100F RHA-300F/180D (with CT) 75 100 300 YS-180F YS-80F YS-150F RHA-400F/240D (with CT) 90 125 360 YS-220F YS-80F YS-180F RHA-500F/300D (with CT) 110 150 440 YS-300F YS-80F YS-220F RHA-500F/300D (with CT) 132 175 528 YS-300F YS-80F YS-300F RHA-750F/450D (with CT) 160 215 640 YS-400F YS-150F YS-300F RHA-750F/450D (with CT) 3.7 5 8.7 YS-9F YS-9F YS-9F RHA-25F/8.5DP 5.5 7.5 13 YS-9F YS-9F YS-9F RHA-25F/11DP 7.5 10 17 YS-9F YS-9F YS-9F RHA-25F/15DP 11 15 24 YS-9F YS-9F YS-12F RHA-25F/21DP 15 20 32.5 YS-20F YS-9F YS-20F RHA-65F/32D + TIB-65F 18.5 25 39.5 YS-20F YS-9F YS-25F RHA-65F/35D + TIB-65F 22 30 46.5 YS-20F YS-20F YS-25F RHA-65F/43D + TIB-65F 30 40 62.5 YS-32F YS-20F YS-38F RHA-65F/56D + TIB-65F 37 50 74 YS-32F YS-20F YS-38F RHA-125F/68DP 45 60 90 YS-32F YS-32F YS-50F RHA-125F/80DP 55 75 110 YS-50F YS-32F YS-50F RHA-125F/105DP 75 100 150 YS-80F YS-32F YS-80F RHA-150F/135DP 90 125 180 YS-80F YS-50F YS-100F RHA-180F/155DP 110 150 220 YS-80F YS-50F YS-125F RHA-300F/180D (with CT) 132 175 264 YS-80F YS-50F YS-150F RHA-400F/240D (with CT) 160 215 320 YS-150F YS-80F YS-180F RHA-400F/240D (with CT) 200 267 400 YS-150F YS-80F YS-220F RHA-500F/300D (with CT) 250 333 500 YS-220F YS-80F YS-300F RHA-500F/450D (with CT) 300 -- 600 YS-220F YS-150F YS-400F RHA-500F/450D (with CT) RHA-25F/15DP D IEC Contactors 380-440V Capacity 1. Regarding Star operation time is as follows: In case of small inertia (e.g. Non-load, MG set, fan, compressor) is less than 30 seconds. The limit for number of continuity starting is 3 times, more than need off time. 2. The term of electrical endurance is more than 0.5 million operations. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-55 IEC Contactors Application Tables Application to Transformers Single Phase (2-Poles series connection) Three Phase Contactor Type IEC Contactors D (kVA) (A) (kVA) (A) (kVA) (A) (kVA) (A) YS1N-9F 1.5 7.5 2 5 3 7.5 4 5 YS1N-12F 2 9 3 7 3.5 9 5 7 YS1N-20F 2.5 10 4 9.5 5 13 7.5 9.5 YS1N-25F 4 17 7.5 16 6.5 17 12 16 YS1N-32F 5 25 10 24 10 25 18 24 YS1N-38F 7 32 10 24 12 32 25 62 YS1N-40F 7 32 10 24 12 32 25 32 YS1N-50F 9 40 18 40 15 40 30 40 YS1N-65F 10 46 20 45 18 46 35 45 YS1N-80F 15 62 35 55 35 62 42 55 YS1N-100F 17 75 33 75 30 75 42 55 YS1N-125F 20 90 33 75 35 90 60 75 YS1N-150F 25 110 40 90 42 110 70 90 YS1N-180F 25 110 50 110 42 110 85 110 YS1N-220F 25 110 57 130 42 110 100 130 YS1N-300F 33 150 57 130 57 150 100 130 1. At the moment when transformer connected with the supply source, large transient inrush current will flow, and its value is much larger than the normal current (about 20 times greater). The duration may be a few cycles. Application to Lamp Loads Tungsten Lamp 100V 200V Contactor 100W 1A YS1N-9F 11 7 5 4 3 2 1 -- 22 14 11 8 YS1N-12F 13 8 6 5 4 2 1 -- 28 18 14 YS1N-20F 13 8 6 5 4 3 1 1 30 20 15 YS1N-25F 19 12 9 7 6 3 1 1 40 26 YS1N-32F 26 17 13 10 8 5 2 1 50 YS1N-38F 35 23 17 14 11 7 3 2 YS1N-40F 35 23 17 14 11 7 3 2 YS1N-50F 50 33 25 20 16 10 5 YS1N-65F 65 42 32 26 21 13 6 150W 200W 250W 300W 1.5A 2A 2.5A 3A 500W 1000W 1500W 100W 150W 200W 250W 300W 500W 1000W 1500W 5A 10A 15A 0.5A 0.75A 1A 1.25A 1.5A 2.5A 5A 7.5A 6 4 2 1 10 8 5 2 1 12 10 6 2 2 20 16 13 8 4 2 33 26 20 16 10 5 3 70 46 35 28 23 14 7 4 70 46 35 28 23 14 7 4 3 100 66 50 40 33 20 10 6 4 130 86 65 52 43 26 13 8 1. When tungsten lamp is lit, its inrush current is about 30 times the normal current and the duration is about 10 milliseconds. In general application to tungsten lamp load, magnetic contactors should be selected so that the rated operational current of the contactor will be no less than two times the normal current of tungsten lamp load, considered its making current capacity. 2. The value of above table shows available quantities as connected in parallel. D-56 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Application Tables Fluorescent Lamp (rapid start time) 100V 200V 40W Contactor 60W 80W 100W 220W 40W 1 2 1 0.59A 0.96A 0.92A (1.2A) (1.1A) 1 1.17A 1 1.55A 2 2.5A 1 2.7A 1 0.29A (0.6A) 60W 80W 100W 2 1 1 1 0.48A 0.46A 0.58A 0.78A (0.55A) 220W 2 1.3A 1 1.35A 2 2.5A 18 (9) 11 (10) 11 9 5 4 4 37 (18) 22 (20) 23 18 14 8 8 4 YS1N-12F 23 (11) 14 (12) 15 11 9 5 5 48 (23) 29 (25) 30 24 17 10 10 5 YS1N-20F 25 (12) 15 (13) 16 12 9 6 5 51 (25) 31 (27) 32 25 19 11 11 6 YS1N-25F 33 (16) 20 (18) 21 17 12 8 7 68 (33) 41 (36) 43 34 25 15 14 8 YS1N-32F 42 (20) 26 (22) 27 21 16 1 9 86 (41) 52 (45) 54 43 32 20 18 10 YS1N-38F 59 (29) 36 (31) 38 29 22 14 12 120 (58) 72 (63) 76 60 44 26 25 14 YS1N-40F 59 (29) 36 (31) 38 29 22 14 12 120 (58) 72 (63) 76 60 44 26 25 14 YS1N-50F 84 (41) 52 (45) 54 42 32 20 18 172 (83) 104 (90) 108 86 64 38 37 20 YS1N-65F 100 (54) 67 (59) 70 55 41 26 24 224 (108) 135 (118) 141 112 83 50 48 26 D 1. When fluorescent lamp lights, generally the starting current is a few times the normal current and its duration may be within a few seconds. Magnetic contactors should be selected so the rated operation current will be the same as the total load current of the fluorescent lamp loads. 2. The values of above table show available quantities as connected in parallel. 3. ( ) values in above table show in the case of the light for Low power factor type. Mercury Lamp 100V (low power factor type/high power factor type) Contactor 40W 1.25A/ 0.55A 200V (low power factor type/high power factor type) 100W 200W 250W 300W 400W 700W 1000W 2.6A/ 1.4A 8.0A/ 4.9A 14.5A/ 8.5A 21A/ 12A 4.6A/ 2.6A 5.1A/ 3.0A 6.0A/ 3.7A 40W 100W 200W 250W 300W 400W 0.53A/ 1.0A/ 1.9A/ -- 0.65A 1.2A 2.1A/ 1.5A 2.5A/ 1.8A 3.3A/ 2.3A 700W 1000W 5.9A/ 4.1A 8.3A/ 5.8A YS1N-9F 8/20 4/7 2/4 2/3 1/2 1/2 -/1 -/- 20/- 11/16 5/9 5/7 4/6 3/4 1/2 1/1 YS1N-12F 11/25 5/10 3/5 2/4 2/3 1/2 -/1 -/1 26/- 14/21 7/11 6/9 5/7 4/6 2/3 1/2 YS1N-20F 12/27 5/10 3/5 2/3 2/4 1/3 1/1 -/1 28/- 15/23 7/12 7/10 6/8 4/6 2/3 1/2 YS1N-25F 16/36 7/14 4/7 3/6 3/5 2/4 1/2 -/1 37/- 20/30 10/16 9/13 8/11 6/8 3/4 2/3 YS1N-32F 20/45 9/17 5/9 4/8 4/6 3/5 1/2 1/2 47/- 25/38 13/20 11/16 10/13 7/10 4/6 3/4 YS1N-38F 28/63 13/25 7/13 6/11 5/9 4/7 2/4 1/2 66/- 35/53 18/29 16/23 14/19 10/15 5/8 4/6 YS1N-40F 28/63 13/25 7/13 6/11 5/9 4/7 2/4 1/2 66/- 35/53 18/29 16/23 14/19 10/15 5/8 4/6 YS1N-50F 40/90 19/35 10/19 9/16 8/13 6/10 3/5 2/4 94/- 50/76 26/41 23/33 20/27 15/21 8/12 6/8 YS1N-65F 52/118 25/46 14/25 12/21 10/17 8/13 4/7 3/5 122/- 65/100 34/54 30/43 26/36 19/28 11/15 7/11 1. When mercury lamp lights, the starting current is about 1.5-1.8 times the normal current and its duration may be a few minutes (within 8 times). Magnetic contactors should be selected so the rated operational current will be the same as the total load current of the mercury lamp loads. 2. The values of above table show available quantities as connected in parallel. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-57 IEC Contactors YS1N-9F IEC Contactors Application Tables Application to Capacitor-Switching Single Phase (2 pole series connection) Contactor Type IEC Contactors D 200-240V Three Phase 380-440V 200-240V 380-440V (kVA) (A) (kVA) (A) (kVA) (A) (kVA) (A) YS1N-9F 1.2 6 1.7 4.3 2 6 3 4.3 YS1N-12F 1.8 9 2.4 6 3 9 5 8 YS1N-20F 1.8 9 3.2 8 3 9 6 9 YS1N-25F 3 15 4.8 12 5 15 10 15 YS1N-32F 4 20 6 15 7 20 15 23 YS1N-38F 5 25 8 20 8 23 20 30 YS1N-40F 5 25 8 20 8 23 20 30 YS1N-50F 7.5 38 12 30 13 38 26 40 YS1N-65F 9 45 16 40 15 45 30 46 YS1N-80F 10 50 20 50 20 58 35 53 YS1N-100F 13 65 20 50 26 75 50 76 YS1N-125F 15 75 26 65 26 75 50 76 YS1N-150F 18 90 30 75 35 105 70 105 YS1N-180F 20 100 36 90 40 115 75 114 YS1N-220F 26 130 40 100 45 130 80 120 YS1N-300F 30 150 60 150 50 150 100 150 1. The making and breaking capacity of the contactor are more than 15 times the rated operational current for capacitor loads in this table. 2. For applications without series reactor: The contactor should be selected to have the making current capacity which is more than 1.5 times the inrush current of the capacitor according to percentage impedance of transformer and impedance of the electric circuit. 3. Large transient inrush current may occur at the moment of switching the capacitors. So when inrush current of capacitor exceeds 15 times the rated operational current of the magnetic contactor, series reactor which has 6% of capacitor reactance shall be connected in the circuit. 4. At single phase application, two poles are used for switching of the capacitor. D-58 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC IEC Contactors Application Tables TYPICAL FULL LOAD CURRENT OF INDUCTION MOTORS Single-Phase Motors Three-Phase, 4-Pole Motors 50/60 Hz hp 220V A 240V A kW hp 220-230V 380-400V 415V A A A 440V A 500V A 660-690V A 0.37 0.55 0.75 1.1 1.5 0.5 0.75 1 1.5 2 3.9 5.2 6.6 9.6 12.7 3.6 4.8 6.1 8.8 11.7 0.37 0.55 0.75 1.1 1.5 0.5 0.75 1 1.5 2 1.8 2.75 3.5 4.4 6.1 1.03 1.6 2 2.6 3.5 2 2.5 3.5 0.99 1.36 1.68 2.37 3.06 1 1.21 1.5 2 2.6 0.6 0.9 1.1 1.5 2 1.8 2.2 3 4 4.4 2.5 3 4 5.5 6 15.7 18.6 24.3 29.6 34.7 3.6 4.8 6.1 8.8 11.7 2.2 3 3.7 4 5.5 3 4 5 5.5 7.5 8.7 11.5 13.5 14.5 20 5 6.6 7.7 8.5 11.5 5 6.5 7.5 8.4 11 4.42 5.77 7.1 7.9 10.4 3.8 5 5.9 6.5 9 2.8 3.8 4.4 4.9 6.6 5.2 5.5 6 7 7.5 7 7.5 8 9 10 39.8 42.2 44.5 49.5 54.4 36.5 38.7 40.8 45.4 50 7.5 9 10 11 15 10 12 13.5 15 20 27 32 35 39 52 15.5 18.5 20 22 30 14 17 21 28 13.7 16.9 20.1 26.5 12 13.9 15 18.4 23 8.9 10.6 11.5 14 17.3 18.5 22 25 30 33 25 30 35 40 45 64 75 85 103 113 37 44 52 60 68 35 40 47 55 60 32.8 39 45.3 51.5 58 28.5 33 39.4 45 50 21.3 25.4 30.3 34.6 39 37 40 45 51 55 50 54 60 70 75 126 134 150 170 182 72 79 85 98 105 66 71 80 90 100 64 67 76 83 90 55 60 65 75 80 42 44 49 57 61 59 63 75 80 90 80 85 100 110 125 195 203 240 260 295 112 117 138 147 170 105 115 135 138 165 97 109 125 131 146 85 89 105 112 129 66 69 82 86 98 100 110 129 132 140 136 150 175 180 190 325 356 420 425 450 188 205 242 245 260 182 200 230 240 250 162 178 209 215 227 143 156 184 187 200 107 118 135 140 145 147 150 160 180 185 200 205 220 245 250 472 483 520 578 595 273 280 300 333 342 260 270 280 320 325 236 246 256 289 295 207 210 220 254 263 152 159 170 190 200 200 220 250 257 280 270 300 340 350 380 626 700 800 826 900 370 408 460 475 510 340 385 425 450 475 321 353 401 412 450 281 310 360 365 400 215 235 274 280 305 295 300 315 335 355 400 410 430 450 480 948 980 990 1100 1150 546 565 584 620 636 500 510 535 550 580 473 481 505 518 549 416 420 445 472 500 320 325 337 355 370 375 400 425 445 450 500 545 580 600 610 1180 1250 1330 1400 1410 670 710 760 790 800 610 650 690 730 740 575 611 650 680 690 527 540 574 595 608 395 410 445 455 460 475 500 645 680 1490 1570 850 900 780 820 730 780 645 680 485 515 D IEC Contactors kW Notes : 1. The full load current of the motor varies with the supply voltage, frequency, number of poles, and number of phases (single- or three-phase). 2. For selection of contactors and thermal overload relays, confirm the actual full load current of the motor. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC D-59 IEC Contactors Application Tables IEC Contactors D D-60 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC