S i5341-D -E V B S i5341- D E V A L U A T I O N B O A R D U S E R ' S G U I D E Description EVB Features The Si5341-D-EVB is used for evaluating the Si5341 Any-Frequency, Any-Output, Jitter-Attenuating Clock Multiplier revision D. The device revision is distinguished by a white 1 inch x 0.187 inch label with the text "SI5341-D-EB" installed in the lower left hand corner of the board. (For ordering purposes only, the terms "EB" and "EVB" refer to the board and the kit respectively. For the purpose of this document, the terms are synonymous in context.) Powered from USB port or external power supply. Onboard 48 MHz XTAL allows free-run mode of operation on the Si5341 or up to 3 input clocks for synchronous clocking. Feedback clock input for optional zero delay mode. CBPro GUI programmable VDD supply allows device to operate from 3.3, 2.5, or 1.8 V. CBPro GUI programmable VDDO supplies allow each of the 10 outputs to have its own power supply voltage selectable from 3.3, 2.5, or 1.8 V. CBPro GUI-controlled voltage, current, and power measurements of VDD and all VDDO supplies. Status LEDs for power supplies and control/status signals of Si5341. SMA connectors for input and output clocks. Figure 1. Si5341-D Evaluation Board Rev. 0.9 7/16 Copyright (c) 2016 by Silicon Labs Si5341-D-EVB Si5 341- D- E V B 1. Functional Block Diagram Below is a functional block diagram of the Si5341-D-EB. This evaluation board can be connected to a PC via the main USB connector for programming, control, and monitoring. See section "3. Quick Start" or section "8. Installing ClockBuilderPro (CBPro) Desktop Software" for more information. Figure 2. Si5341-D-EB Functional Block Diagram 2 Rev. 0.9 S i5 3 4 1 -D -E V B 2. Si5341-D-EVB Support Documentation and ClockBuilderPro Software All Si5341-D-EVB schematics, BOMs, User's Guides, and software can be found online at the following link: http://www.silabs.com/products/clocksoscillators/pages/si538x-4x-evb.aspx 3. Quick Start 1. 2. 3. 4. 5. Install ClockBuilderPro desktop software from http://www.silabs.com/CBPro. Connect a USB cable from Si5341-D-EB to the PC where the software was installed. Leave the jumpers as installed from the factory, and launch the ClockBuilderPro software. You can use ClockBuilderPro to create, download, and run a frequency plan on the Si5341-D-EB. For the Si5341 data sheet, go to http://www.silabs.com/timing. Rev. 0.9 3 Si5 341- D- E V B 4. Jumper Defaults Table 1. Si5341-D-EB Jumper Defaults Location Type I = Installed 0 = Open Location Type I = Installed 0 = Open JP1 2 pin O JP23 2 pin O JP2 2 pin I JP24 2 pin O JP3 2 pin O JP25 2 pin O JP4 2 pin I JP26 2 pin O JP5 2 pin I JP27 2 pin O JP6 2 pin I JP28 2 pin O JP7 2 pin I JP29 2 pin O JP8 2 pin I JP30 2 pin O JP9 2 pin O JP31 2 pin O JP10 2 pin I JP32 2 pin O JP13 2 pin O JP33 2 pin O JP14 2 pin I JP34 2 pin O JP15 3 pin 1 to 2 JP35 2 pin O JP16 3 pin 1 to 2 JP36 2 pin O JP17 2 pin O JP38 3 pin All Open JP18 2 pin O JP39 2 pin O JP19 2 pin O JP40 2 pin O JP20 2 pin O JP41 2 pin O JP21 2 pin O J36 5 x 2 Hdr All 5 installed JP22 2 pin O *Note: Refer to the Si5341-D-EB schematics for the functionality associated with each jumper. 4 Rev. 0.9 S i5 3 4 1 -D -E V B 5. Status LEDs Table 2. Si5341-D-EB Status LEDs Location Silkscreen Color Status Function Indication D27 5VUSBMAIN Blue Main USB +5 V present D22 3P3V Blue DUT +3.3 V is present D26 VDD DUT Blue DUT VDD voltage present D25 INTR Red MCU INTR (Interrupt) active D21 READY Green MCU Ready D24 BUSY Green MCU Busy D27, D22, and D26 are illuminated when USB +5 V, Si5341 +3.3 V, and Si5341 VDD supply voltages, respectively, are present. D25, D21, and D24 are status LEDs showing on-board MCU activity. Figure 3. Status LEDs Rev. 0.9 5 Si5 341- D- E V B 6. Clock Input Circuits (INx/INxB and FB_IN/FB_INB) The Si5341-D-EB has eight SMA connectors (IN0/IN0B-IN2/IN3B and FB_IN/FB_INB) for receiving external clock signals. All input clocks are terminated as shown in Figure 4 below. Note input clocks are ac-coupled and 50 terminated. This represents four differential input clock pairs. Single-ended clocks can be used by appropriately driving one side of the differential pair with a single-ended clock. For details on how to configure inputs as single-ended, please refer to the Si5341 data sheet. Figure 4. Input Clock Termination Circuit 7. Clock Output Circuits (OUTx/OUTxB) Each of the twenty output drivers (10 differential pairs) is ac-coupled to its respective SMA connector. The output clock termination circuit is shown in Figure 5 below. The output signal will have no dc bias. If dc coupling is required, the ac coupling capacitors can be replaced with a resistor of appropriate value. The Si5341-D-EVB provides pads for optional output termination resistors and/or low frequency capacitors. Note that components with schematic "NI" designation are not normally populated on the Si5341-D-EB and provide locations on the PCB for optional dc/ac terminations by the end user. Figure 5. Output Clock Termination Circuit 6 Rev. 0.9 S i5 3 4 1 -D -E V B 8. Installing ClockBuilderPro (CBPro) Desktop Software To install the CBOPro software on any Windows 7 (or above) PC: Go to http://www.silabs.com/CBPro and download ClockBuilderPro software. Installation instructions and User's Guide for ClockBuilderPro can be found at the download link shown above. Please follow the instructions as indicated. 9. Using the Si5341-D-EVB 9.1. Connecting the EVB to Your Host PC Once ClockBuilderPro software is installed, connect to the evaluation board with a USB cable as shown below. Figure 6. EVB Connection Diagram Rev. 0.9 7 Si5 341- D- E V B 9.2. Additional Power Supplies Although additional power (besides the power supplied by the host PC's USB port) is not needed for most configurations, two additional +5 VDC power supplies (MAIN and AUX) can be connected to J33 and J34 (located on the bottom of the board, near the USB connector). Refer to the Si5341-D-EB schematic for details. The Si5341-EB comes preconfigured with jumpers installed at JP15 and JP16 (pins 1-2 in both cases) in order to select "USB". These jumpers, together with the components installed, configure the evaluation board to obtain all +5 V power solely through the main USB connector at J37. This setup is the default configuration and should normally be sufficient. Figure 7 shows the correct installation of the jumper shunts at JP15 and JP16 for default or standard operation. Figure 7. JP15-JP16 Standard Jumper Shunt Installation Errata Note:Some early versions of the 64-pin Si534x-EBs may have the silkscreen text at JP15-JP16 reversed regarding EXT and USB, i.e., USB EXT instead of EXT USB. Regardless, the correct installation of the jumper shunts for default or standard operation is on the right hand side as read and viewed in Figure 7. The general guidelines for single USB power supply operation are listed below: Use either a USB 3.0 or USB 2.0 port. These ports are specified to supply 900 mA and 500 mA respectively at +5 V. If you are working with a USB 2.0 port and you are current limited, turn off enough DUT output voltage regulators to drop the total DUT current 470 mA. (Note: USB 2.0 ports may supply > 500 mA. Provided the nominal +5 V drops gracefully by less than 10%, the EVB will still work.) If you are working with a USB 2.0 and you are current limited and need all output clock drivers enabled, re-configure the EB to drive the DUT output voltage regulators from an external +5 V power supply as follows: Connect Move 8 external +5 V power supply to terminal block J33 on the back side of the PCB. the jumper at JP15 from pins 1-2 USB to pins 2-3 EXT. Rev. 0.9 S i5 3 4 1 -D -E V B 9.3. Overview of ClockBuilderPro Applications Note: The following instructions and screen captures may vary slightly depending on your version of ClockBuilder Pro. The ClockBuilderPro installer will install two main applications: Figure 8. Application #1: ClockbuilderPro Wizard Use the CBPro Wizard to: Create a new design Review or edit an existing design Export: create in-system programming Figure 9. Application #2: EVB GUI Use the EVB GUI to: Download configuration to EVB's DUT (Si5341) Control the EVB's regulators Monitor voltage, current, power on the EVB Rev. 0.9 9 Si5 341- D- E V B 9.4. Common ClockBuilderPro Work Flow Scenarios There are three common workflow scenarios when using CBPro and the Si5341-D-EVB. These workflow scenarios are: Workflow Scenario #1: Testing a Silicon Labs-Created Default Configuration Workflow Scenario #2: Modifying the Default Silicon Labs-Created Device Configuration Workflow Scenario #3: Testing a User-Created Device Configuration Each is described in more detail in the following sections. 9.5. Workflow Scenario #1: Testing a Silicon Labs-Created Default Configuration The flow for using the EVB GUI to initialize and control a device on the EVB is as follows. Once the PC and EVB are connected, launch ClockBuilder Pro by clicking on this icon on your PC's desktop. Figure 10. ClockBuilderPro Desktop Icon If an EVB is detected, click on the "Open Default Plan" button on the Wizard's main menu. CBPro automatically detects the EVB and device type. Figure 11. Open Default Plan Once you open the default plan (based on your EVB model number), a popup will appear. Figure 12. Write Design to EVB Dialog Select "Yes" to write the default plan to the Si5341 device mounted on your EVB. This ensures the device is completely reconfigured per the Silicon Labs default plan for the DUT type mounted on the EVB. 10 Rev. 0.9 S i5 3 4 1 -D -E V B Figure 13. Writing Design Status After CBPro writes the default plan to the EVB, click on "Open EVB GUI" as shown below. Figure 14. Open EVB GUI The EVB GUI will appear. Note all power supplies will be set to the values defined in the device's default CBPro project file created by Silicon Labs, as shown below. Figure 15. EVB GUI Window Rev. 0.9 11 Si5 341- D- E V B 9.5.1. Verify Free-Run Mode Operation Assuming no external clocks have been connected to the INPUT CLOCK differential SMA connectors (labeled "INx/INxB") located around the perimeter of the EVB, the DUT should now be operating in free-run mode, as the DUT will be locked to the crystal in this case. You can run a quick check to determine if the device is powered up and generating output clocks (and consuming power) by clicking on the Read All button highlighted above and then reviewing the voltage, current and power readings for each VDDx supply. Note: Shutting "Off" then "On" of the VDD and VDDA supplies will power-down and reset the DUT. Every time you do this, to reload the Silicon Labs-created default plan into the DUT's register space, you must go back to the Wizard's main menu and select "Write Design to EVB": Figure 16. Write Design to EVB Failure to do the step above will cause the device to read in a pre-programmed plan from its non-volatile memory (NVM). However, the plan loaded from the NVM may not be the latest plan recommended by Silicon Labs for evaluation. At this point, you should verify the presence and frequencies of the output clocks (running to free-run mode from the crystal) using appropriate external instrumentation connected to the output clock SMA connectors. To verify the output clocks are toggling at the correct frequency and signal format, click on View Design Report as highlighted below. Figure 17. View Design Report 12 Rev. 0.9 S i5 3 4 1 -D -E V B Your configuration's design report will appear in a new window, as shown below. Compare the observed output clocks to the frequencies and formats noted in your default project's Design Report. Figure 18. Design Report Window 9.5.2. Verify Locked Mode Operation Assuming you connect the correct input clocks to the EVB (as noted in the Design Report shown above), the DUT on your EVB will be running in "locked" mode. Rev. 0.9 13 Si5 341- D- E V B 9.6. Workflow Scenario #2: Modifying the Default Silicon Labs-Created Device Configuration To modify the "default" configuration using the CBPro Wizard, click on Edit Configuration with Wizard: Figure 19. Edit Configuration with Wizard You will now be taken to the Wizard's step-by-step menus to allow you to change any of the default plan's operating configurations. Figure 20. Design Wizard 14 Rev. 0.9 S i5 3 4 1 -D -E V B Note you can click on the icon on the lower left hand corner of the menu to confirm if your frequency plan is valid. After making your desired changes, you can click on Write to EVB to update the DUT to reconfigure your device real-time. The Design Write status window will appear each time you make a change. Figure 21. Writing Design Status 9.7. Workflow Scenario #3: Testing a User-Created Device Configuration To test a previously created user configuration, open the CBPro Wizard by clicking on the icon on your desktop and then selecting Open Design Project File. Figure 22. Open Design Project File Rev. 0.9 15 Si5 341- D- E V B Locate your CBPro design file (*.slabtimeproj or *.sitproj file).design file in the Windows file browser. Figure 23. Browse to Project File Select Yes when the WRITE DESIGN to EVB popup appears: Figure 24. Write Design to EVB Dialog The progress bar will be launched. Once the new design project file has been written to the device, verify the presence and frequencies of your output clocks and other operating configurations using external instrumentation. 16 Rev. 0.9 S i5 3 4 1 -D -E V B 9.8. Exporting the Register Map File for Device Programming by a Host Processor You can also export your configuration to a file format suitable for in-system programming by selecting Export as shown below: Figure 25. Export Register Map File You can now write your device's complete configuration to file formats suitable for in-system programming. Figure 26. Export Settings Rev. 0.9 17 Si5 341- D- E V B 10. Writing a New Frequency Plan or Device Configuration to Non-Volatile Memory (OTP) Note: Writing to the device non-volatile memory (OTP) is NOT the same as writing a configuration into the Si5341 using ClockBuilderPro on the Si5341-D-EB. Writing a configuration into the EVB from ClockBuilderPro is done using Si5341 RAM space and can be done virtually unlimited numbers of times. Writing to OTP is limited as described below. Refer to the Si534x/8x Family Reference Manuals and device data sheets for information on how to write a configuration to the EVB DUT's non-volatile memory (OTP). The OTP can be programmed a maximum of two times only. Care must be taken to ensure the configuration desired is valid when choosing to write to OTP. 11. Si5341-D-EVB Schematic and Bill of Materials (BOM) The Si5341-D-EVB Schematic and Bill of Materials (BOM) can be found online at http://www.silabs.com/products/clocksoscillators/pages/si538x-4x-evb.aspx Note: Please be aware that the Si5341-D-EB schematic is in OrCad Capture hierarchical format and not in a typical "flat" schematic format. 18 Rev. 0.9 ClockBuilder Pro One-click access to Timing tools, documentation, software, source code libraries & more. Available for Windows and iOS (CBGo only). www.silabs.com/CBPro Timing Portfolio www.silabs.com/timing SW/HW www.silabs.com/CBPro Quality www.silabs.com/quality Support and Community community.silabs.com Disclaimer Silicon Laboratories intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Laboratories reserves the right to make changes without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy or completeness of the included information. Silicon Laboratories shall have no liability for the consequences of use of the information supplied herein. This document does not imply or express copyright licenses granted hereunder to design or fabricate any integrated circuits. The products are not designed or authorized to be used within any Life Support System without the specific written consent of Silicon Laboratories. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected to result in significant personal injury or death. Silicon Laboratories products are not designed or authorized for military applications. Silicon Laboratories products shall under no circumstances be used in weapons of mass destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons. Trademark Information Silicon Laboratories Inc.(R) , Silicon Laboratories(R), Silicon Labs(R), SiLabs(R) and the Silicon Labs logo(R), Bluegiga(R), Bluegiga Logo(R), Clockbuilder(R), CMEMS(R), DSPLL(R), EFM(R), EFM32(R), EFR, Ember(R), Energy Micro, Energy Micro logo and combinations thereof, "the world's most energy friendly microcontrollers", Ember(R), EZLink(R), EZRadio(R), EZRadioPRO(R), Gecko(R), ISOmodem(R), Precision32(R), ProSLIC(R), Simplicity Studio(R), SiPHY(R), Telegesis, the Telegesis Logo(R), USBXpress(R) and others are trademarks or registered trademarks of Silicon Laboratories Inc. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand names mentioned herein are trademarks of their respective holders. Silicon Laboratories Inc. 400 West Cesar Chavez Austin, TX 78701 USA http://www.silabs.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Silicon Laboratories: Si5341-EVB SI5341-EVB